My Weigh Ultraship Series User Manual



Similar documents
Phoenix Body Fat Scale Manual

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Operating instructions Platform/floor scales

OPERATION MANUAL MARSDEN-200 PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

Model 349KLX Remote Display Digital Scale User Instructions

AutoRanging Digital MultiMeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

BW-500 BED WEIGHER USER MANUAL

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Manual Ranging MultiMeter

Body Fat Scale Instructions for use

Radio BMR100 INSTRUCTION MANUAL. ENGLISH (Original instructions)

BODY FAT & HYDRATION % MONITOR SCALE

PREPARATION. INTERNAL CALIBRATION (No external weight needed.) SPAN CALIBRATION

Deluxe Electronic Body Fat Analyzer Body Weight Scale

CASTON. Crane Scale. OWNER S MANUAL (BT Ver.) 9007-CT3-BT

Microwave Meter. Instruction Manual

NOTE: Additional user information for your printer may be available in the "Manuals" section at support.dell.com.

OCSM Series. High Resolution Digital Crane Scale. User Guide

Digital Air Pressure Gauge Users Manual

XP Series Balances Operation Manual

LITHIUM BALANCE CHARGER

User's Guide. Pinless Moisture Meter. Model MO257

Instruction Manual HI Refractometer for Refractive Index and Brix Measurements

Operating Manual Electronic Wheelchair Scale with cable display M50610

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Care and Handling of Your VAIO Computer

ELECTRIC BICYCLE OWNER S MANUAL

ELECTRIC BICYCLE OWNER S MANUAL

High precision counting scale. Operation Manual. l RCZ-A Series

HIGH PRECISION BALANCE MWP OWNER S MANUAL. MWP ver.1.0

Instruction Manual FL

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

CONTIENTS. 1. SPECIFICATIONS (mm) CAUTIONS INSTALLATION INSTRUCTION

User Guide. HDMI Active Cable Extender. DVI-7370c

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

3000W Power Inverter

BASIC BODY COMPOSITION SCALE

SATEX SA Manual. Weegtechniek holland b.v. PRECISION BALANCE. Patroonsweg DA Zeewolde HOLLAND

Mini Power Bank and Charger

Instruction Manual Crane Scales PCE-HS Series

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Thermistor Thermometer MODEL NO

Replacing the Gateway M320 Keyboard

PART 1 - INTRODUCTION...

Video Cassette Player

Wall-Mounting your HP computer. User Guide

PLEASE READ ALL INSTRUCTIONS BEFORE USE AND SAVE A COPY FOR FUTURE REFERENCE!

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer. May 2006

Achat 110 M passive full-range speaker. user manual

2-SLICE COOL TOUCH TOASTER

Digital Photo Picture Frame. Operation Manual

Instruction Manual Temp 4/5/6 Temperature Meter Series

Memory Modules User Guide

Instant Ear Thermometer

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Dehumidifier Users manual. For Models: DH45S DH65S

AM/FM PLL Clock/Table Radio

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Bluelab Soil ph Meter Instruction Manual

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

Mini Digital Altimeter & Climb rate & Barometer & Thermometer & Compass & Weather forecast & Time

INSTRUCTION MANUAL DTH Fax: (503)

OCS-S High Resolution Digital Crane Scale

WSD130 SOLDERING STATION

e I N S T RUC TION M ANU A L

AM/FM ALARM CLOCK RADIO

ER102. Emergency Crank Weather Radio Owner s Manual.

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Table Of Contents

NFC Communication Tray Model: HHX-IT3-Z

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Installation and Operation Back-UPS 1250, 1300, 1500

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

TS1200 Intelligent Lead Free Soldering Station. Operation Manual

How To Keep An Eye On Electric Safety

TIG INVERTER INSTRUCTION MANUAL

ADVANCED INTERNET DOWNLOADABLE POSTAL & SHIPPING SCALE

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Model 5511 Filler Controller User s Manual Version 1.1 October 2011

INSTRUCTIONS FOR ANALOGUE QUARTZ AND MECHANICAL WATCHES

Auto-ranging Digital Multimeter INSTRUCTION MANUAL

HEAT SIPHON ANSWERBOOK

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

TECHANGLE November 30, 2005 TECHNICAL PAGE

DSM155 Digital LED Light Meter User s Manual DSM155

User s Manual Before using the inverter, you need to read and save the safety instructions.

3.5 Dual Bay USB 3.0 RAID HDD Enclosure

VersaCare Bed. Quick Reference Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

12 Volt 30 Amp Digital Solar Charge Controller

Memory Modules. Document Part Number: This guide explains how to replace and upgrade memory in the computer.

B-AIR BLOWER CUB POWER MODEL # CP-1

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

User Guide. Model Insulation Tester / Megohmmeter

2013 VTech Printed in China US

da Vinci 1.0 User Manual

Operating Manual Color Changing Fountains

Transcription:

My Weigh Ultraship Series User Manual

Low Batteries, bad battery connections & Faulty AC Adaptors are the #1 cause of Ultraship malfunction and inaccuracy! We test all of our scale returns from consumers. Fully 60% of consumer returns are battery related problems. This sounds silly but it's true! A scale will perform slowly, or read inaccurately when it has low batteries. Please replace the batteries often (and only use good quality batteries). We include good quality batteries with all of our scales but batteries can run low in storage. If your scale simply won't turn on while on Battery power, this is often caused by loose battery connections. Battery prongs (terminals) are made of metal. They must be making good contact with your batteries in order for the scale to power on. You can use a paperclip to slightly bend the battery prongs to make them have a better connection. Also some poorly designed batteries have recessed or partially obstructed battery terminals. This may cause your prongs to be touching the plastic housing of the battery instead of the metal battery terminal. A Faulty AC adaptor can cause your scale to act unstable with numbers "jumping" all around. Please test your scale with a good set of batteries (instead of the AC adaptor) to determine if perhaps the AC adaptor is faulty. Some Ultra-75 scales will need a different or improved AC adaptor then the Ultra-50 and Ultra-30. You will know if you have this problem because the scale will power on but the numbers will fluctuate ("bounce" all around). Most Ultraship 75's do not have this problem, it's only happened a few times and it was caused by a slightly underpowered AC Adaptor (the output was slightly less then normal). The Ultra 75 requires just a bit more power then the Ultra 30, 35, 50 or 55 and thus is the only model affected by an AC adaptor that is giving a slightly less then normal output. IMPORTANT MANUAL CORRECTION: 2005/2006 Model Notes: During production we sometimes modify the Ultraship slightly to make it easier to use and perform more stable. This can cause some typos in the manual. Note that on the newest Ultraships there is NO STABLE INDICATOR, we removed it on some models as it was causing a software conflict. The BEEP function was also removed due to customer complaints. TROUBLESHOOTING & OPERATION NOTES 1) If the scale does not perform accurately, please recalibrate as outlined in the manual. 2) If the Display ever becomes locked on EEEEE, this indicates that the scale was shocked, dropped or otherwise damaged and the delicate weighing sensors have been damaged. You can try recalibrating the scale (If the sensor has not been hurt too badly it may work again after recalibration). Otherwise you will have to follow the warranty instructions that came with your scale. 3) If the display becomes locked on 8888, this often indicates low power. However sometimes it also may indicate a serious zero mark error. This means when you turn the scale on, it can't determine what zero is (a slight zero mark error will cause situation #1 above) Thus, if new batteries do not fix this error please follow the warranty instructions. 4) If the display shows UNST, this means the scale is not stable. Try operating the scale on a more stable surface & be sure nothing is on the tray or stuck under the tray when you turn it on. If the problem persists, it may be an indication of fatal sensor damage. 5) If the scale is on AC power and it will not properly stabilize (fluctuating weights are shown on the display), this may be caused by a malfunctioning AC adaptor. Please try operating the scale on Battery power to see if the problem persists. If the problem does not occur on Battery power then it is a sign of a bad or improper AC adaptor. Please replace the AC adaptor. If the problem occurs on Battery power also, it may be a sign of environmental issues, please the special warning in this manual. Although the ULTRASHIP is designed to be extremely durable, Itʼs important that you never overload or drop/shock the scale. If you ship the scale be certain to pack it extremely well to prevent shipping damage. Scales are delicate instruments and unlike Cellular phones, scales have delicate sensors that determine how much an item weighs. If you drop or shock your scale, these sensors "feel" the shock and are sometimes destroyed. This happens with all digital scales. We design our scales to be as resistant to shock or drops as possible, however there is no way for us to protect 100% against load cell or sensor damage. A well-treated scale will provide years of reliable and accurate weighing. However an abused scale will only work until itʼs sensors are damaged.

damaged. Click here for a printable PDF Version of the Ultra-30/35/50/55 Manual Click here for a printable PDF Version of the Ultra-75 Manual SAFETY PRECAUTIONS All safety messages are identified by the words "WARNING" and "CAUTION". These words mean the following:!warning Important information to alert you to a situation that might cause serious injury and damage to your property if instructions are not followed.!caution Important information that tells how to prevent damage to the equipment. When using the scale, the following safety precautions should always be followed.! WARNING Use only the correct AC adaptor with the scale. Other adaptors may cause permanent electrical damage.! CAUTION Avoid placing the scale in direct sunlight, this may cause discoloration or malfunction. Replace all batteries at the same time Do not replace only a portion of the 4 batteries as this may cause a malfunction. If the scale is not to be used for a long period of time, remove all batteries from the battery compartment to avoid leakage, which may cause damage to this scale. Avoid overloading the scale, as this may cause permanent damage and void your warranty do not EVER exceed the maximum capacity of the scale Keep the scale away from water this scale is not water resistant. Shock, injury and electrical damage can occur if used in a wet location! Matter charged with static electricity could affect accuracy. Discharge all static electricity. For example, one method is to use Static-Guard spray, and spray it on both sides of the weighing platform. SPECIFICATIONS Model UL-35 Capacity 35lb/16kg

Division 2g/0.1oz Division 5g/0.2oz Model UL-55 Capacity 55lb/25kg Division 2g/0.1oz Division 10g/0.5oz Model UL-75 Capacity 75.9lb/34kg Division 5g/0.1oz Division 10g/0.5oz Platter / Tray 160 203mm Net/gross weight 750/950g Package Standard carton: 28 26 10.5(cm3) Operating Temperature Optimum: 15-30c (62-90f) Power source 4 R14C Size Batteries or AC/DC Adapter 9V/100mA (optional) or 10V **SPECIAL WARNING** Cell-Phones, Cordless-Phones, and any radio-frequency device can cause temporary interference and cause the scale to temporarily not work properly. Please do not use any electronic device near the scale. Just like in an Airplane, do not use your cell-phone near the scale when it is in use. While there is NO risk of permanent damage to the scale, interference can cause an incorrect calibration or incorrect weight readings. CALIBRATION When to calibrate - calibration is almost never required. If the scale is inaccurate, calibration may be desired when the scale is first set up for use, or if the scale is moved to a different altitude or gravitation. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations can occur. How to calibrate **The UL-30/35 requires a 10kg calibration weight to calibrate. The UL-50/55 and UL-75 require a 20kg calibration weight. (you can use a combination of weights such as 5 2kg weights)**

1. The scale must be powered OFF. Press and hold [ZERO] first, then Press [ON/OFF] while keeping the [ZERO] button depressed, then release both keys. The display will show the A/D value (a series of random numbers). 2.Wait for the stable A/D value to be displayed, Press [UNIT] the display will show "0SAVE", then the display will return to the random A/D value. 3.Place the 10kg (UL-30) or 20kg (UL-50 & UL-75) weight(s) on platform. Wait for the stable A/D value to display, then press [UNIT], the display will show "0SAVE". Calibration is complete, remove the weight(s). 4.Turn the scale OFF (Press the ON/OFF key), then turn it back ON and check some weight readings. If calibration is still incorrect, repeat calibration but try it more slowly. If calibration is repeatedly incorrect then: 1) Replace the batteries, 2) Try a more stable surface or vibration and interference free location, 3) Be sure there is no static electricity on the scale (use an anti-static spray to remove static electricity) FEATURES l Auto shut off (adjustable) Auto calibration l Auto zero tracking AC Power (optional) l Removable display w/3ft cord kg /lb /lb:oz /g conversion l Large LCD (6digits 15 mm high) hold function l Large square weighing tray with multiple attachments PARTS DESCRIPTION Right SIDE: AC adaptor Socket ON/OFF key: Turns the scale power on/off. HOLD KEY: Holds the display for 120 seconds. ZERO key (for TARE)

Sets display to zero or Subtracts weight of a container. UNIT key Changes weighing units, eg. kg or lb,. Batteries Use R14C 4 pieces dry batteries HOLD FUNCTION Once the hold key is pressed, the weight will remain on the display for 120 seconds after the item has been removed from the scale so the weight can easily be read. 1) Place the item on the scale's platform. 2) Wait for the stable weight to be displayed. 3) Press the hold key. The. hold indicator will turn-on. 4) Remove the item from the scale platform. The itemʼs weight reading will remain on the display for 120 seconds. 5) Quit the hold function: Once an item is weighed and the hold function is enabled; you may want to end the hold function, Press the hold key again to cancel the. hold indicator and return the scale to normal weighing mode. AUTO OFF FUNCTION SETTINGS To enable or disable the auto-off feature follow these directions: 1. Start with the power off (the power must be OFF). Press and hold the [Hold] key first, then press [ON/OFF], then release both keys. The display will show A_ON or A_OFF. 2.Selection of auto shut off mode. Press the [Hold] key, the display will show A_ON or A_OFF. A_ON means the auto shut off function is active. Press [Hold] again, the display will show A_OFF, this means the auto shut off function is inactive. 3.Return to weighing mode. Press [ON/OFF] to turn the power off, press [ON/OFF] again to turn on the power and the scale will return to weighing mode. WEIGHING

WEIGHING Before weighing Whenever possible, please allow the scale to warm up for several seconds after first turning the power on so that the scale will function properly and accurately. Error messages EEEE: Overload : Low battery Weighing procedures 1.Press [ON/OFF] to turn on the scale. When the power is turned on, all display segments appear for a few seconds and "0" will appear on the display. 2.Select the weighing unit with [UNIT]. Press [UNIT] to select a weighing unit "kg", "lb", lb/oz, or g Once the unit has been selected, the selected unit will be displayed next to the weight value. 3.Start weighing If you do not use a container for weighing, Verify the reading is "0". If not, press [TARE] to display "0". Place the items to be weighed on the platform. The weight will be displayed on the LCD If you use a container for weighing, Place an empty container on the platform. Wait for the stability indicator to be displayed and press [TARE]. Place the objects to be weighed in the container. The weights will be displayed on the LCD