TIG INVERTER INSTRUCTION MANUAL

Similar documents
UNI FLAME AUTOLIFT MIG/MMA/TIG. 165/190/220/250 Inverter Manual. 240 Volt. Standard MIG / MAG

SVENSKA DANSK NORSK

How To Use A Power Supply Unit (Upu)

User s Manual AURORA 1.2K/2.2K

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

User s Manual Before using the inverter, you need to read and save the safety instructions.

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

3000W Power Inverter

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

INFRARED QUARTZ WALL HEATER

Uninterruptible Power Supply ERA LED 1.5 ERA LED 2.0 ERA LED 2.6. User s manual

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

12 Volt 30 Amp Digital Solar Charge Controller

Use and Care Manual. Model CPA12KH AIR CONDITIONER

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Drayton Digistat +2RF/+3RF

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Achat 115MA full-range speaker. user manual

REB 1 REB 3 REB 5 REB 6 REB 8 REB 10 REB 12 REB 16

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

120Volt 60-70A ARC WELDER Rev

Bench Autoclave. Standard Operating Procedure. For Installation, Use and Maintenance

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Antenna Splitter ASA 1. Instruction manual

15GAL STEEL OIL DRAIN WITH 110V PUMP

User Manual DONGGUAN SHENGYANG INDUSTRIAL CO., LTD. SY WMVC Smart Grid Tie Microinverter. Dongguan Shengyang Industrial Co., Ltd.

Manual. Solar Fountain Mobile Phone Charger

Tone Hammer 500. Owners Manual. Manual Version 1.0

Installation and safety instructions for AC/DC built-in devices

YSmart Technology Co.,Ltd

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

Meaco 30L and Meaco 40L dehumidifier instruction manual

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

BITMAIN. APW PSU Series User Guide

Portable Air Conditioner

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Congratulations! Thank you!

Failure code manual. content

400 Amp Rechargeable Jump Start System RAC-HP082

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Fire Protection Notice No. 9 ELECTRICAL SAFETY

Single-Phase AC Synchronous Generator

VIESMANN. Installation and service instructions VITOTROL 100. for contractors

MODEL 2202IQ (1991-MSRP $549.00)

Dehumidifier Users manual. For Models: DH45S DH65S

Installation Instructions for Alarm Module Kit A043F059

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

TruPower-Portable-500W. Solar Starter kit

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

10000HXL31/15000HXL31/20000HXL31

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

USER S MANUAL HSC-24A

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

MICA HEATER INSTRUCTION MANUAL Model No: UHM V 50Hz 2200W

12-Volt 10-Amp Regulated Power Supply

MULTI XS 4003 Battery charger

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

victron energie USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG Victron Atlas 12/850

Active Monitor Box McCrypt S.T.E.V.E. 15. Order No

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Ultrasonic support removal tank

wilkinsonstar.com TIG 200P DC Pulse TIG / MMA Welding - Dual voltage Order code JT-200PDV OPERATOR MANUAL

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

ADM1TE 5/30A DIN rail single phase two wire energy meter

AutoRanging Digital MultiMeter

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

12. Inspection and Maintenance

Electrical Safety Tips. Help us keep you safe

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Model UT33A: OPERATING MANUAL Table of Contents (1)

Contact Details. Please note that some of the contact details on this PDF document may not be current.

Instructions for Safe Use

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

For installation guide see reverse of book

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

POWER TO GET THE JOB DONE

Doorbell Intercom Security System

i410/i1010 AC/DC Current Clamp

LOXONE 12 Channel Amplifier

Charge Regulator SCR 12 Marine

Installation and Operation Back-UPS 1250, 1300, 1500

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

VLT Series 300 Watt True Sine Wave Inverter

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

Operating instructions

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Transcription:

TIG INVERTER INSTRUCTION MANUAL

Contents Warning General Description Block Diagram Main Parameters Circuit Diagram Installation and Operation Caution Maintenance Spare Parts List Troubleshooting 3 4 4 5 6 6 8 9 10 11 EC DECLARATION OF CONFORMITY We hereby declare that the following machines: TIG180P Dual Voltage / TIG200P AC/DC correspond to the following edicts and standards: EMC Directives: 73/23/EEC and 89/336/EEC European Standard: EN/IEC60974 2

Warning TIG Inverter Instruction Manual Welding and cutting is dangerous to the operator, people in or near the working area, and the surrounding environment. Therefore, the performance of welding and cutting must only be done under the strict and comprehensive observance of all relevant safety regulations. Please read and understand this instruction manual carefully before installation and operation. Switching function modes during welding could potentially damage the equipment. Disconnect the electrode-holder cable from the equipment before welding. A safety switch is necessary to prevent the equipment from electric-leakage. Use only high quality welding tools and equipment with this Inverter. Operators should be suitably trained to use this equipment. Electric Shock Connect the earth cable according to standard regulation. Avoid any contact with live components of the welding circuit, electrodes and wires with bare hands. The operator should wear suitable welding gloves while using this machine. The operator should keep the work piece insulated from himself/ herself. Smoke and Gas generated while welding or cutting Avoid breathing in smoke and gas from welding or cutting. Make sure you are working in a well ventilated area. Arc light-emission Always wear a welding helmet and appropriate work clothes while welding. Measures should also be taken to protect people in or near the area you are working. Fire hazard Sparks from welding may cause fire. Remove any flammable items from the immediate area before welding. Have a fire extinguisher nearby. Noise Surface noise is generated while welding and cutting. Use suitable hearing protection. Machine Fault Consult this instruction manual in the case of a fault. Contact your local dealer or supplier for further advice. 3

General Description This welding machine is manufactured with advanced inverter technology. With power component MOSFET and PWM technology, the inverter converts DC voltage, which is rectified from input AC voltage, to high 100KHz frequency AC voltage; as a consequence, the voltage is transformed and rectified. Therefore, it results in a smaller transformer and lighter inverter machine, which increases welding performance by 30%. The high frequency oscillation, which enables the output of high frequency DC, is employed in the arc-starting system. The features of this product are as follows: stable current, reliable, fully portable, efficient and quiet in operation. When MMA welding, this welding machine features stable output and the option of arc force. In case of normal arc input voltage, the stability of welding current output is not compromised with variation of arc length, therefore it results in a stable performance of welding operation. In the case of low input voltage, welding output current increases while arc voltage decreases, as a consequence, the length of arc, which is not sufficient, will automatically compensate and the modulation of arc force is accessible. In case of the input arc voltage being too low to maintain arc, the output of this welding equipment descends steeply, which avoids the splash generated due to over current input. When TIG welding, this welding equipment features stable output current and that the welding current output does not change with the variation of the length of arc. In case of short circuit of electrode, the voltage automatically decreases to 0V, which limits the impairment of electrode and pollution to environment. Warranty of maintenance for main components is one years. During the warranty maintenance period, all maintenance is free of charge, not including any deliberate damage or alteration to this welding equipment. In the case of a fault with the inverter machine, only qualified electricians are authorized to carry out repairs. Block Diagram INPUT PWM CONTROL 4

Main Parameters TIG Inverter Instruction Manual TIG180P TIG200P Fuse Rating 16 amp 20 amp Generator Friendly + / 15% + / 15% Input Power Voltage 110 / 220 volt (single phase) AC 230 volt (single Phase) Rate Input Power Capacity Input Voltage Frequency 3.9 KVA 4.5 KVA 50 / 60 Hz Output Current Range Duty Cycle (25 C) MMA 10 180 amps TIG 5 180 amps 110 volt 140 amps @ 60% 240 volt 180 amps @ 60% AC TIG 17 200 amps DC TIG 10 200 amps AC TIG 200 amps @ 60% DC TIG 185 amps @ 60% ARC Starting HF HF Weight 8.8 kg 25 kg Overall Dimensions 371 x 155 x 295 mm 493 x 330 x 320 mm Protection Class Pulse Frequency Ip23 MH 50 200 Hz LH 0.5 2 Hz Ip23 MH 0.5 300 Hz LH 0.5 2 Hz Welding Thickness DC 0.3 6 mm AC 0.5 8 mm Slope In 2 10 seconds variable 0 1 seconds varible Slope Out 0 5 seconds variable 0 10 seconds variable Clean Width 20 80% 5

Circuit Diagram (single phase input) INPUT PWM CONTROL Installation and Operation Please note: Any extension of mains cables or torch cables may affect the performance of this welding equipment. Input voltage is decided by the length of the cable, therefore longer than standard cables will reduce the amount of resistance. It is recommended to maintain the standard length of main cables and torch cables. 12 10 9 8 7 13 6 11 1 2 3 4 5 TIG180P 1 : Mains Lead 2 : Arc / Torch Lead Connection (35/50 Dinze) 3 : Torch Gas Connection 4 : HF Torch Connection Socket 5 : Earth Socket Connection 6 : Pulse Frequency Switch 6

7 : Slope Out Timer Control 8 : MMA / TIG Mode Switch 9 : Mains On/Off Switch 10 : Current Output Control 11 : Slope In Control Timer 12 : O.C. Warning Light 13 : 2 Pole / 4 Pole Switch (Continuous weld / Non continuous weld) TIG Inverter Instruction Manual 14 13 12 11 7 8 9 10 1 2 3 4 5 6 TIG 200P AC/DC 1 : Mains Lead 2 : Arc / Torch Lead Connection (35/50 Dinze) 3 : Torch Gas Connection 4 : HF Torch Connection 5 : Footswitch Connection 6 : Earth Socket COnnection 7 : AC / DC Switch 8 : 2 Pole / 4 Pole Switch (Continuous weld / Non continuous weld) 9 : MMA / TIG Mode Switch 10 : Pulse Frequency Switch 11 : Mains On/Off Switch 12 : Digital Indicator Display (Welding Current) 13 : Supply Failure Warning Light 14 : O.C. Warning Light 7

1 2 3 4 1 : Gas Pre Flow Timer 2 : Output Current Control (Main) 3 : Base CUrrent Setting 4 : Slope Out Timer 5 : Arc Force Adjustment 6 : Pulse Frequency Control 7 : Pulse Duty Control 8 : Clean Area / Width Adjustment 9 : Post Flow Adjustment 5 6 7 8 9 Caution 1. Working Environment 1.1 The location in which this welding equipment is installed should be free from dust, corrosive chemical gas, flammable gas or materials, and a maximum of 80% humidity. 1.2 Avoid the operation of welding in the open air unless the working area sheltered is from the elements. The ambient temperature of the working environment should be maintained within 10 C to +40 C. 1.3 Allow a distance of at least 300mm (12 ) between this machine and any walls. 1.4 Make sure the area you are working in is well ventilated. 2. Safety Tips 2.1 Ventilation: Good ventilation is of critical importance for the performance and service life of this inverter welding machine. Maintain a minimum distance of 30cm (12 ) between the inverter machine and any other objects in or near the working area. 2.2 Do not operate this machine when the O.C. Light is lit. A sudden halt may occur while the welding operation is carried out while this welding machine is in over-load status. Under this circumstance, it is unnecessary to restart this welding equipment. Keep the built-in fan working to bring down the temperature inside this welding equipment. 2.3 This welding equipment uses automatic voltage compensation, which enables the maintaining of the voltage range within the given range. In case the voltage of input power 8

TIG Inverter Instruction Manual supply current exceeds the stipulated value, it is possibly damaging to the components of this welding equipment. 2.4 An earth terminal is available for this welding equipment. Connect with the earth cable to avoid static and electric shock. 2.5 DO NOT contact the output terminal when the welding operation is performed. An electric shock will occur. Maintenance Exposure to extremely dusty, damp, or corrosive air is damaging to this machine. In order to prevent any possible failure or fault of the inverter, clean any dust at regular intervals with compressed air. Please note: Proper maintenance should be carried out by a skilled and qualified electrician on a regular basis. Any attempts by an unauthorised or unskilled individual to remove the outer casing, or conduct repairs or modifications to the machine will void the warranty. 9

Spare Parts List Description A Front Panel B Cover C Carrying Strap / Handle D Dial E Dinze Socket F On / Off Switch G Power Cable H Internal Fan I Bottom PCB J Heat Sink K Center PCB L Rubber Feet M Top PCB TIG180P Part Number TIG200P TIG180p 10

TIG200p TIG Inverter Instruction Manual 11

Troubleshooting Please note: In the event of a fault with this inverter welding machine, only qualified electricians are authorised to undertake repairs. Fault Symptoms No output from machine, O.C. Light not lit, internal fan not working No output from machine, O.C. Light not lit, internal fan not working, machine suddenly halts operation No output from machine, O.C. Light not lit, internal fan is working No output from machine, O.C. Light is lit Reason 1. Possible failure of voltage input. Consult an authorised technician. 2. Possible failure of power supply. Check plug and power cable for damage. 1. Possible failure of power supply. Check plug and power cable for damage. 2. The machine is in temporary shut down mode due to over heating. Wait a few minutes for machine to cool down and it will automatically re-start. 3. Power supply input is faulty. Check plug and power cable for damage. 4. The machine is in temporary shut down mode due to constantly being switched on and off. Unplug the machine and wait 5 minutes before re-starting. 5. 24 volt relay board may be defective. Consult an authorised technician for a replacement. 6. The top PCB is not receiving power. Consult an authorised technician. 1. Possible loose connection in machine. Consult an authorised technician. 2. Possible failure of Control Module / Drive Circuit / Drive Module. Consult an authorised technician for a replacement if necessary. 3. Possible failure of MOSFET / Transformers / Rectifier Diode / Internal connections. Consult an authorised technician for a replacement if necessary. 1. The machine is in temporary shut down mode due to over heating. Wait a few minutes for machine to cool down and it will automatically re-start. 2. The machine is in temporary shut down mode due to excess current. 3. Possible function failure of inverter machine. Unplug the machine and perform the following checks: a) If the fault indicator is on MOSFET the top PCB is possibly faulty. b) If the fault indicator is off there could be damage to center PCB / possible damage to secondary rectifier of transformer. c) Possible damage to feedback circuit. Consult an authorised technician. 12