FIRE EXTINGUISHER TRAINING



Similar documents
Class A - Wood, paper, cloth, trash, plastics Solid combustible materials that are not metals. (Class A fires generally leave an Ash.

On-Line Fire Extinguisher Training

EACH CLASS of fire A, B, C, or D has a different source. Some

FIRE SAFETY FOR OFFICE WORKERS

Portable Fire Extinguisher Presentation

GUIDELINE 5. CLASSES OF FIRE, TYPES OF PORTABLE FIRE EXTINGUISHERS, INSPECTION & MAINTENANCE OF FIRE EXTINGUISHERS IN UNIVERSITY BUILDINGS

and Extinguisher Training

Fire Extinguishers. A Health and Safety Guideline for Your Workplace. Fire Extinguishing Methods. Introduction. Types of Extinguishers

HISTOLOGY LABORATORY EMERGENCY PROCEDURES

All You Ever Wanted to Know About Fire Extinguishers...

Fire Safety and Extinguishers

Fire Safety in Laboratories. University of Tennessee Environmental Health and Safety

"USING FIRE EXTINGUISHERS SAFELY"

exit routes and fire protection

FIRE PREVENTION PLAN

FIRE SAFETY HANDBOOK

FDNY C14 Certificate of Fitness Quiz

Natural Gas Emergencies

Model Safety Program

Workplace Fire Safety

Fire & Safety. Fire Safety Training For FHSc Staff and Students in Health Care Facilities

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

Presented by: Rich Perry Marsh Risk Consulting

Oxidizer(s) Management and Use Guidelines

EXTINGUISHER. The purpose of this module is to sensitize firefighters on the subject of extinguishers.

Awareness Properties of Fire Safe Practices Human Behavior and Fire Fire Safety Systems

Fire Protection and Prevention

Healthcare Help Supporting Health Providers. Module 2 Resources for Fire Warden Refresher Training HH.NET LTD

Compressed Gas Cylinder Safety

Fire Extinguishers Water Extinguishers

FIRE SAFETY ONLINE TRAINING

FIRE,FIREFIGHTING & FIREFIGHTING EQUIPMENT

FedEx s Fire Suppression System

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

General Confined Space Awareness

Dry Ice Color Show Dry Ice Demonstrations

FIRE AND LIFE SAFETY TRAINING

Notes. Material 1. Appropriate Flammable Liquids

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

Company Name Chemical Spill Prevention & Clean-up Procedures Program. Last Revised On 00/00/0000

PROCEDURES PREVENTION OF ACCIDENTAL IGNITION

Mechanical Systems Competency 1.20

December Newsletter by Vincent Dunn Backdraft and flashover, what is the difference?

Reaction of Potassium Permanganate and Glycerin.

Annual Fire Safety Training Module

Recovery of Elemental Copper from Copper (II) Nitrate

Sample Written Program. For. Flammable Liquids

Installation Instructions for Alarm Module Kit A043F059

Vehicle Fire Protection. An Ownerʼs Manual for ANSUL Fire Suppression/Detection Systems

Fire Safety. Workbook Second Edition, 2004

Fire Safety PROCEDURES January 2011

LESSON PLAN 1. Fire Science. Key Terms and Concepts. ash chemical reaction combustion Consumer Product Safety Commission endothermic exothermic

ADMINISTRATIVE SERVICES MANUAL

Texas Department of Insurance. Fire Safety. Provided by. Workers Health & Safety. Pub. No. HS01-028D (7-08)

Question: How effective is Tundra Fire Extinguishing Spray vs. a Traditional Fire Extinguisher?

General Chemistry I (FC, 09-10) Lab #3: The Empirical Formula of a Compound. Introduction

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

Hazmat Materials Training Fact Sheet Module 2 Classification. The classification of hazardous materials is based on three key factors:

Compressed Gas Cylinder Program

Standard Operating Procedure (SOP) Car/Truck Battery Safety

Flammable and Combustible Liquids. Slide 1 (of 23)

Handling and Storage of Flammable Materials at the Work Site

Occupational Health and Safety Orientation Manual

Oxidation States of Copper Two forms of copper oxide are found in nature, copper(i) oxide and copper(ii) oxide.

1130 K Street Building - Sacramento Emergency Procedures

Standard Operating Procedure

Process Safety Management of Highly Hazardous & Explosive Chemicals. Safe Work Practices

Chemical Reactions Practice Test

DIN 2403 Identification of pipelines according to the fluid conveyed. Marking of pipes according to fluid transported

MOTOR FUEL DISPENSING SAFETY

The Empirical Formula of a Compound

Emergency Response Guide

Remember the best arguments are based on the strongest evidence and can explain why opposing arguments are incorrect.

Whoosh Bottle Safe Laboratory Practices

PORTABLE FIRE FIRE SOLUTIONS 1. Portable Fire Equipment Solutions COPY ONLY

Global Warming and Greenhouse Gases Reading Assignment

Combustible Dust - Things that go Boom. W. Jon Wallace, CSP, MBA Workplace Group, LLC O: E: jwallace@workplacegroup.

How To Use A Boat Fire Extinguisher

IN CASE OF EMERGENCY. Emergency Telephone Number 112

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Chapter 16: Tests for ions and gases

527 CMR: BOARD OF FIRE PREVENTION REGULATIONS 527 CMR 14.00: FLAMMABLE AND COMBUSTIBLE LIQUIDS, FLAMMABLE SOLIDS OR FLAMMABLE GASES

St. John s University Fire Safety Plan

Fire Risk Assessment For Simple Premises

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

ENVIRONMENT, SAFETY, HEALTH, AND QUALITY DIVISION

Hotel Fire Safety for staff

Fire Response Plan - Code Red

Ionization alarms are best suited for rooms, which contain highly combustible material. These types of material include:

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Laboratory Safety Manual

PLAN SUBMITTAL REQUIREMENTS FOR SPRAY BOOTHS AND SPRAYING ROOMS EXTINGUISHING SYSTEMS

A Study of Matter. Video Notes

COMBUSTIBLE DUST in the WOOD PRODUCTS INDUSTRY

Guidance for Those Who Use and Store Gas Cylinders

FIRE RISK ASSESSMENT

Automatic fire-extinguishing systems for commercial cooking

NATURAL GAS EMERGENCY PROCEDURES AND ACCIDENT PREVENTION

VERIFY HARD COPY AGAINST WEB SITE IMMEDIATELY PRIOR TO USE

Transcription:

FIRE EXTINGUISHER TRAINING Fire safety, at its most basic, is based upon the principle of keeping fuel sources and ignition sources separate. Three things must be present at the same time to produce fire: 1. Enough Oxygen to sustain combustion 2. Enough Heat to reach ignition temperature 3. Some Fuel or combustible material Together, they produce the chemical reaction that is fire. Take away any of these things and the fire will be extinguished. FUEL CLASSIFICATIONS Fires are classified according to the type of fuel that is burning. If you use the wrong type of extinguisher on the wrong class of fire, you might make matters worse. It is very important to understand the four different fire (fuel) classifications: Class A: Wood, paper, cloth, trash, plastics solids that are not metals. Class B: Flammable liquids gasoline, oil, grease, acetone. Includes flammable gases. Class C: Electrical energized electrical equipment. As long as it is plugged in. Class D: Metals potassium, sodium, aluminum, magnesium. Requires Metal-X, foam, and other special extinguishing agents.

Most fire extinguishers will have a pictograph label telling you which types of fire the extinguisher is designed to fight. For example, a simple water extinguisher might have a label like this, which means it should only be used on Class A fires. TYPES OF FIRE EXTINGUISHERS Different types of fire extinguishers are designed to fight different classes of fire. The three most common types of fire extinguishers are: 1. Water (APW) Large, silver fire extinguishers that stand about 2 feet tall and weigh about 25 pounds when full. APW stands for Air-Pressurized Water. Filled with ordinary tap water and pressurized air, they are essentially large squirt guns. APW s extinguish fire by taking away the Heat element of the Fire Triangle. APW s are designed for Class A fires only: Wood, paper, cloth. Here are a couple of reasons you need to be careful about which extinguisher you use: Using water on a flammable liquid fire could cause the fire to spread. Using water on an electrical fire increases the risk of electrocution. If you have no choice but to use an APW on an electrical fire, make sure the electrical equipment is unplugged or de-energized. APW s will be found in older buildings, particularly in public hallways, as well as in residence halls on campus. They will also be found in computer laboratories. It is important to remember, however, that computer equipment must be disconnected from its electrical source before using a water extinguisher on it. The Ohio State University/OARDC/ATI Page 2

2. Carbon Dioxide (CO 2 ) The pressure in a CO 2 extinguisher is so great, bits of dry ice might shoot out of the horn! CO 2 cylinders are red. They range in size from 5 pounds to 100 pounds or larger. On larger sizes, the horn will be at the end of a long, flexible hose. CO 2 s are designed for Class B and C (flammable liquids and electrical sources) fires only! CO 2 s will frequently be found in laboratories, mechanical rooms, kitchens, and flammable liquid storage areas. In accordance with NFPA regulations (and manufacturers recommendations) all CO 2 extinguishers at OSU undergo hydrostatic testing and recharge every five years. Carbon dioxide is a non-flammable gas that takes away the oxygen element of the Fire Triangle. CO 2 is very cold as it comes out of the extinguisher, so it cools the fuel as well. A CO 2 may not be very effective in extinguishing a Class A fire because it may not be able to displace enough oxygen to successfully put the fire out. Class A materials may also smolder and re-ignite. The Ohio State University/OARDC/ATI Page 3

3. Dry Chemical (ABC, BC, DC) ABC extinguishers are red. On campus, they range in size from five pounds to 20 pounds. On the OSU campus, ABC extinguishers are filled with a fine, yellow powder. This powder is mostly composed of monoammonium phosphate. The extinguishers are pressurized with nitrogen. Dry chemical extinguishers put out fire by coating the fuel with a thin layer of dust. This separates the fuel from the oxygen in the air. The powder also works to interrupt the chemical reaction of fire. These extinguishers are very effective at putting out fire. Dry chemical extinguishers come in a variety of types. You may see them labeled: DC (for dry chemical) ABC (can be used on Class A, B, or C fires) BC (designed for use on Class B and C fires) It is extremely important to identify which types of dry chemical fire extinguishers are located in your area! An ABC extinguisher will have a label like this, indicating it may be used on Class A, B, and C fires. You don t want to mistakenly use a BC extinguisher on a Class A fire thinking that it was an ABC extinguisher. Dry chemical extinguishers with powder designed for Class B and C fires ( BC extinguishers) may be located in places such as commercial kitchens and areas with flammable liquids. On campus you will find ABC s in public hallways of new buildings, in laboratories, break rooms, offices, chemical storage areas, mechanical rooms, University vehicles, etc. The Ohio State University/OARDC/ATI Page 4

HOW TO USE A FIRE EXTINGUISHER It is easy to remember how to use a fire extinguisher if you remember the acronym, PASS. Pull Aim Squeeze Sweep Pull the pin This will allow you to discharge the extinguisher. Aim at the base of the fire Hit the fuel if you aim at the flames, the extinguishing agent will pass right through and do no good. Squeeze the top handle This depresses a button that releases the pressurized extinguishing agent. Sweep from side-to-side until the fire is completely out. Start using the extinguisher from a safe distance away and then slowly move forward. Once the fire is out, keep an eye on the area in case it re-ignites. The Ohio State University/OARDC/ATI Page 5

RULES FOR FIGHTING FIRES Fires can be very dangerous and you should always be certain that you will not endanger yourself or others when attempting to put out a fire. For this reason, when a fire is discovered, 1. Assist any person in immediate danger to safety, if it can be accomplished without risk to you. 2. Call 9-911 or activate the building fire alarm. The fire alarm will notify the fire department as well as other building occupants and shut off the air handling system to prevent the spread of smoke. If the fire is small (and only after having done these two things), you may attempt to use an extinguisher to put it out. However, before deciding to fight the fire, keep these things in mind: Know what is burning. If you don t know what is burning, you won t know what kind of extinguisher to use. Even if you have an ABC fire extinguisher, there might be something in the fire that is going to explode or produce toxic fumes. Chances are you will know what is burning, or at least have a pretty good idea, but if you don t, let the fire department handle it. Is the fire spreading rapidly beyond the point where it started? The time to use an extinguisher is at the beginning stages of the fire. If the fire is already spreading quickly, it is best to simply evacuate the building. As you evacuate a building, close doors and windows behind you as you leave. This will help to slow the spread of smoke and fire. The Ohio State University/OARDC/ATI Page 6

Do not fight the fire if: You don t have adequate or appropriate equipment. If you don t have the correct type or large enough extinguisher, it is best not to try fighting the fire. You might inhale toxic smoke. When synthetic materials such as the nylon in carpeting or foam padding in a sofa burn, they can produce hydrogen cyanide, acrolein, and ammonia in addition to carbon monoxide. These gases can be fatal in very small amounts. Your instincts tell you not to. If you are uncomfortable with the situation for any reason, just let the fire department do their job. The final rule is to always position yourself with an exit or means of escape at your back before you attempt to use an extinguisher to put out a fire. In case the extinguisher malfunctions, or something unexpected happens, you need to be able to get out quickly. You don t want to become trapped. Tamela L. Brown, M.S. Greg Ferrell, Director Public Safety Environmental Health and Safety Officer University Police The Ohio State University/OARDC/ATI The Ohio State University/OARDC/ATI 1680 Madison Avenue 1328 Dover Road Wooster, Ohio 44961 Wooster, Ohio 44691 Ph: 330-263-3663 Ph: 330-287-0111 Fax: 330-263-3914 Fax: 330-202-3579 E-mail: brown.3047@osu.edu E-mail: ferrell.3@osu.edu http://www.oardc.ohio-state.edu/ehs/ http://www.oardc.ohio-state.edu/police/ The Ohio State University/OARDC/ATI Page 7

FIRE EXTINGUISHER TRAINING QUIZ NAME DATE OF COMPLETION 1. An example of two Class B fuels would be: a. Cardboard, newspapers b. Lamp, hot plate c. Grease, paint thinner 2. An APW (water extinguisher) is safe to use on an electrical fire. 3. Carbon Dioxide extinguishers are designed for which types of fuels? a. Class B and C b. Class A, B and C c. Class A and C d. Class A and B 4. Which type of extinguisher has a hard horn on the end of a flexible hose or metal arm? a. APW (air-pressurized water) b. CO 2 (carbon dioxide) c. ABC (dry chemical) 5. As a general rule, you should not attempt to fight a fire if it is spreading rapidly. 6. ABC fire extinguishers extinguish fire by cooling it down. 7. Water will not extinguish most flammable liquid fires. 8. You should always keep an exit or means of escape at your back when trying to fight a fire. 9. The three elements of the fire triangle are: a. Water, a heat source, and fuel b. Oxygen, water, and fuel c. Oxygen, fuel, and a heat source d. Fuel, oxygen, and earth 10. Do you know where the nearest fire extinguisher is in your work area? a. Yes b. No The Ohio State University/OARDC/ATI Page 8

ANSWERS: 1. C 2. B 3. A 4. B 5. A 6. B 7. A 8. A 9. C 10. A Please place a copy of your completed quiz in the employee safety training book kept by your supervisor. The Ohio State University/OARDC/ATI Page 9