Latest Low-NOx Combustion Technology for Pulverized-coal-fired Boilers



Similar documents
Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler

2nd IEA Oxyfuel Combustion Conference

THE OPTIMISATION OF BIOMASS COMBUSTION IN SMALL BOILERS

Completion of SCR System for Ninghai Power Plant Unit 4 in China

Introduction to Computational Fluid Dynamics (CFD) for Combustion. (801)

Boiler Tune-up Guide

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

Development and Operating Results of Low SO2 to SO3 Conversion Rate Catalyst for DeNOx Application

NITROGEN OXIDES FORMATION in combustion processes COMBUSTION AND FUELS

1.3 Properties of Coal

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Advantage of Using Water-Emulsified Fuel on Combustion and Emission Characteristics

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal

DeNOx, DeSOx, and CO2 Removal Technology for Power Plant

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers

Development of Coal Gasification System for Producing Chemical Synthesis Source Gas

Continuous flow direct water heating for potable hot water

Carbon Dioxide Membrane Separation for Carbon Capture using Direct FuelCell Systems

Natural Gas Conversions of Existing Coal-Fired Boilers

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

An Experimental Study on Industrial Boiler Burners Applied Low NOx Combustion Technologies

SULFUR RECOVERY UNIT. Thermal Oxidizer

Calculate Available Heat for Natural Gas Fuel For Industrial Heating Equipment and Boilers

Innovation with CFD. Solutions and Equipment

Making Coal Use Compatible with Measures to Counter Global Warming

Efficiency on a large scale CFB Steam Boilers

Optimising Glass Melting Processes with Energy & Mass Balance Calculations

Module 5: Combustion Technology. Lecture 33: Combustion air calculation

Performance Improvement of Pump-turbine for Large Capacity Pumped Storage Power Plant in USA

CFD Simulation of Biofuel and Coal Co-Combustion in a Pulverized Coal Fired Furnace

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Originators of the Flexible Water Tube design

OROT RABIN POWER STATION UNITS x 350 MW

This article provides a basic primer on an

A GUIDANCE NOTE ON THE BEST PRACTICABLE MEANS FOR ELECTRICITY WORKS BPM 7/1 (2014)

COMBUSTION STUDIES OF NATURAL GAS AND SYN-GAS WITH HUMID AIR

Committed to make a better world

MHI s Energy Efficient Flue Gas CO 2 Capture Technology and Large Scale CCS Demonstration Test at Coal-fired Power Plants in USA

BOILER TUNE-UP GUIDE FOR NATURAL GAS AND LIGHT FUEL OIL OPERATION GREG HARRELL, PH.D., P.E.

Energy Efficient Operations and Maintenance Strategies for Boilers

The soot and scale problems

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

PART 11: START-UP PROCEDURES FOR THE INSTALLER

Completion of Hitachinaka Thermal Power Station Unit No. 1

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

GAS HEATING IN COMMERCIAL PREMISES

BOILER OPERATORS HANDBOOK

Process burners (1) operate in heaters and furnaces in

CFD SIMULATION OF NATURAL GAS COMBUSTION AND IST APPLICATION TO TUNNEL KILN FIRING

Babcock & Wilcox's IR-CFB Boiler Technology. S. P. Ganeshan. Papertech -2010, Hyderabad. Divisional Manager, Thermax Limited, Boilers & Heaters Group

WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS

Technical Solutions for Emissions Reduction

State of the Art (SOTA) Manual for Boilers and Process Heaters

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

The prediction of flue gas emissions from the combustion in the industrial tubular heaters

Burner Performance Monitoring Using Advanced Analysis of Optical Signals

THE FLAMELESS OXIDATION MODE : AN EFFICIENT COMBUSTION DEVICE LEADING ALSO TO VERY LOW NOX EMISSION LEVELS

Monitoring Air Emissions on Ships. Restricted Siemens AG 2014 All rights reserved.

COMBUSTION. By: Michael Biarnes. In collaboration with: Bill Freed and Jason Esteves. E Instruments International LLC -

DIRECT-FIRED HEATERS: OPERATOR TRAINING. Intensive 2-Day Training Course for Facility Operators

Chemical Reactions Practice Test

From solid fuels to substitute natural gas (SNG) using TREMP

ATMOSPHERIC EMISSIONS FROM GAS FIRED HOME HEATING APPLIANCES

COKE PRODUCTION FOR BLAST FURNACE IRONMAKING

Biomass Boiler House Best Practices. Irene Coyle & Fernando Preto CanmetENERGY

Assessing the Changes Required by the Industrial Boiler MACT Regulations

Assignment 8: Comparison of gasification, pyrolysis and combustion

High Flux Steam Reforming

(This report is endorsed) Industrivej 20, 9900 Frederikshavn, Danmark

Texas Commission on Environmental Quality Page 1 Chapter Control of Air Pollution from Nitrogen Compounds

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS

Well Positioned for the Future

A Review of Biomass Boiler Technologies. Fernando Preto CanmetENERGY, Natural Resources Canada

Gas emission measurements with a FTIR gas analyzer - verification of the analysis method Kari Pieniniemi 1 * and Ulla Lassi 1, 2

NAWTEC CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

POROUS BURNER - A New Approach to Infrared

Condensing Boiler Efficiency

Session 2: Hot Water Supply

Burners for Glass Melting Furnaces

Long-Term Demonstration of CO2 Recovery from the Flue Gas of a Coal-Fired Power Station

Practical Examples of Heat Regenerative System at Steelmaking Works

Copyright 1984 by ASME. NOx ABATEMENT VIA WATER INJECTION IN AIRCRAFT-DERIVATIVE TURBINE ENGINES. D. W. Bahr. and T. F. Lyon

Control Device Requirements Charts For Oil and Gas Handling and Production Facilities

Description of Thermal Oxidizers

1 DESCRIPTION OF THE APPLIANCE

IAPWS Certified Research Need - ICRN

4 th EU Sout Africa Clean Coal Working Group Meeting

Effect of Self-Heat Circulation on VOCs Decomposition in Regenerative Thermal Oxidizer

Fluidized Bed Based CO 2 Capture by Carbonate Looping

Oil Injection Rotary Screw Compressors Contributing to Environmental Protection and Energy Conservation

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

Development of Grid-stabilization Power-storage Systems Using Lithium-ion Rechargeable Batteries

Development of Air-to-Water Heat Pump for Home Air conditioning/hot Water Supply Combination System with Chilled/Hot Water in European Markets

Thermal efficiency of pulverized fuel boiler

Transcription:

Hitachi Review Vol. 58 (29), No.5 187 Latest Low- Combustion Technology for Pulverized-coal-fired Boilers Kenichi Ochi Kenji Kiyama Hidehisa Yoshizako, Dr. Eng. Hirofumi Okazaki Masayuki Taniguchi, Dr. Eng. OVERVIEW: Hitachi has long been working on the development of low combustion technologies to satisfy the worldwide need for environmental conservation and has devised the world-first concept of inflame reduction which has been applied in the field of pulverized coal combustion technology in the HT-NR burner series. Hitachi has developed new technology to lower levels even further by improving the structural design and operation of a two-stage air port system which is used in combination with in-flame reduction. This work has been progressed using a large-scale combustion test facility that simulates actual furnace conditions and through the use of a numerical analysis technique developed in-house. The new technology can lower boiler outlet by 4% for the same level of. INTRODUCTION AL-fired power plants are still a major energy source worldwide because they provide a stable supply of energy. The environmental burden from coal-fired power plants such as (nitrogen oxide), SOx (sulfur oxide), and 2 (carbon dioxide) is higher relative to the calorific output than in oil-fired (a) or gas-fired plants and therefore the industry needs to reduce emissions and prevent their harmful effects. Hitachi has been working on improving technologies for reducing this environmental burden. is a major environmental burden but can be minimized by better combustion methods (low combustion technologies). In practice, this (b) Fig. 1 Burner Flame (a) and Upgraded Large-scale Combustion Test Facility (b). Babcock-Hitachi K.K. (BHK) has developed a test furnace in which actual boiler furnace conditions can be simulated by operating the burner flame under the same conditions as an actual boiler. This upgraded large-scale combustion test facility played a large role in refining the company s low (nitrogen oxide) combustion techniques. A new two-stage after-air-port system that handles the trade-off between and (carbon monoxide) has been developed and its performance verified at a 6-MWe-class power station in Europe.

Latest Low- Combustion Technology for Pulverized-coal-fired Boilers 188 improvement has been achieved by developing better burner combustion methods for use in furnaces. This paper summarizes the latest low- combustion technologies. DEVELOPMENT OF LOW- MBUSTION TECHNOLOGIES Fig. 2 shows the sequence of steps in the development of low- combustion technologies. The two basic principles used to reduce are in-flame reduction (1) and TSC (two-stage combustion). Significant developments have been achieved through fundamental research, screening of performance, burner structure and TSC port studies, verification in large-scale combustion test facilities, and demonstrations in actual boilers. The fundamental research consisted of an Step 1: Fundamental research Basic properties Elementary combustion test Numerical analysis model Establishment of basic concepts Step 2: Screening of performance and structure Pilot scale combustion test Actual-size flow pattern test Actual-scale burner combustion test Numerical simulation Concrete structure of burner and TSC port Step 3: Verification in large-scale combustion test Large-scale combustion test (Evaluation of fluid dynamics and combustion using multiple burners and TSC ports) Numerical simulation Verification of combustion performance and reliability investigation into the basic reduction reaction and fluid dynamics utilizing measurement devices and numerical analysis. The purpose of our research in this field was to achieve greater accuracy in numerical analysis, clarify ignition mechanisms (2), and firmly establish the reaction models (3) for chemical species such as of and (carbon monoxide). For burner development, the optimum burner structure was determined through screening combustion tests in a 5-kg/h test rig. After that, the fluid dynamics were verified using actual-size burner models. Burner performance was verified in combustion tests using a large single burner (3 t/h coal flow). After determining the combustion methods to use in the burner and TSC port, the combustion performance was verified in a large-scale test furnace equipped with multiple burners and multiple TSC ports. The test furnace simulates conditions in a real boiler. The combustion performance and fluid dynamics of the furnace and the interaction between jets from burners and TSC ports were studied under conditions similar to those of an actual boiler furnace. The reliability of scaling up the design to an actual boiler based on the results from the large test furnace was verified by a numerical analysis that considered the differences in size and heat input. OUTLINE OF LARGE-SCALE MBUSTION TEST FACILITY The large-scale combustion test facility burns approximately 3 t/h of coal. This is one of the largest combustion test facilities in the world. An outline of the test facility is shown in Table 1 and Fig. 3. The test facility was extensively modified with close attention paid to the following items to ensure that conditions in actual boilers could be simulated accurately. (1) Accurate pulverized coal flow measurement Coal for the combustion test was supplied to the furnace through the burner after grinding to the TABLE 1. Outline of Large-scale Combustion Rig Verification in an actual boiler (modification) TSC: two-stage combustion Fig. 2 Development of Low- Combustion Technologies. A comprehensive development process from fundamental research through to verification on actual boilers ensures high reliability. Item Heat input Coal flow Main equipment AQCS: air quality control system Details About 2 MW About 3. t/h Pulverizer, furnace, pulverized coal burners, TSC ports, heat exchangers, AQCS (flue gas treatment system)

Hitachi Review Vol. 58 (29), No.5 189 Convection zone TSC ports Gas temperature High Pulverized coal burners Low Fig. 3 Outline of Large-scale Combustion Test Rig. The test furnace simulates conditions in actual boilers. required fineness by a pulverizer. The distribution of pulverized coal to the burners in the actual boiler setup is determined by accurately measuring the pulverized coal flow to each burner. (2) Higher furnace gas temperature The combustion test furnace is smaller than an actual furnace and this causes a problem with lower temperature due to the relatively higher heat release through the furnace walls. For this reason, the test furnace was modified to optimize the location of refractory material based on an evaluation of the furnace gas temperature profile using a numerical simulation (see Fig. 4). This resulted in a peak furnace gas temperature of 1,85 similar to that in an actual boiler. Achieving a similar temperature profile to an actual boiler allows formation and the combustion speed of pulverized coal to be simulated under the same conditions as in an actual boiler. (3) Rearrangement of burners and TSC ports to match actual boilers The following physical relationships were made adjustable so that the arrangement of burners and TSC ports could be set up in the same way as in the actual boiler. - The distance between burners and TSC ports located above the burners - The distance between furnace side walls and wing burners/tsc ports This allows the residence time for the combustion reaction to be tailored to match actual boiler Fig. 4 Distribution of Furnace Gas Temperature (Numerical Analysis). Testing confirmed that the furnace gas temperature of an actual boiler can be simulated. requirements and allows the distribution of reaction products to be evaluated accurately. METHODS FOR LOWERING AND LEVELS Reduction Reaction in Burner The HT-NR (Hitachi reduction) burner series has a unique combustion mechanism called in-flame reduction whereby is subject to a reduction reaction in the flame of the burner. The in-flame reduction technology causes the to undergo a reduction reaction under the hightemperature and fuel-rich conditions immediately after the ignition of the pulverized coal. Fig. 5 shows an outline of the in-flame reduction concept. Fig. 6 shows the structure of the HT-NR3 burner. The following sections describe the features that allow the burner to achieve extremely low emissions. (1) Expansion of recirculation zone after flame stabilizing ring A rapid ignition of pulverized coal just after the fuel nozzle exit is important for maintaining the stable flame that enhances the operation of inflame reduction. Establishing a flame at the early stages of combustion promotes consumption of oxygen and enlarges the reduction zone where the oxygen concentration is low. In the HT-NR3 burner, the recirculation zone

Latest Low- Combustion Technology for Pulverized-coal-fired Boilers 19 Pulverized coal and primary air Secondary and tertiary air A B C Rapid ignition (production of reducing species) In-flame reduction (high temp. reducing flame) N +O 2 NO NO +HC NH NH +NO N 2 Conventional In-flame reduction Axial distance Fig. 5 Concept of In-flame Reduction. is reduced under high temperatures and fuel-rich conditions just after the ignition point. Guide sleeve Oxidation stability through better flame propagation. The PC (pulverized coal) concentrator has the shape of an artillery shell and is installed in the fuel nozzle of the HT-NR3 burner. The pulverized coal and primary air both tend to move closer to the inner wall of the fuel nozzle in the parallel part of the PC concentrator but the difference in momentum between the pulverized coal and air at the exit of the fuel nozzle means that only the air returns to the central zone. As a result, pulverized coal is concentrated around the flame stabilizing ring located at the exit of the fuel nozzle. (3) Optimum flow pattern of outer air Tertiary air expands to the outside at the burner exit and this forms a reducing zone with fuel-rich conditions in the flame. The tertiary air then returns to the center of the flame after the reduction reaction has completed and mixes with the flame to promote further combustion. In the HT-NR3 burner, a simple guide sleeve effectively separates this reaction from the outer air. The development of HT-NR burner series succeeded in lowering emissions as shown in Fig. 7. Tertiary air Pulverlized coal and primary air Secondary air Circular burner Coal properties Fuel ratio: 2.2 Nitrogen: 1.8wt% Pulverized coal concentrator Flame stablizing ring and baffle plate Fig. 6 The Structure of HT-NR3 Burner. The new burner design takes maximum advantage of in-flame reactions that reduce. (% relative) 5 HT-NR HT-NR2 HT-NR3 formed at the exit of fuel nozzle is enlarged by attaching a baffle plate to the flame stabilizing ring fitted at the exit of the fuel nozzle to redirect the secondary air jets that blow air from around the circumference of the fuel so that they blow in a more outward direction. The rapid heating of the pulverized coal in the region of hot gas that is retained in the recirculation zone enhances ignition. (2) Concentration of pulverized coal The concentration of the pulverized coal is a critical factor in enhancing ignition. The denser the pulverized coal, the shorter the distance between coal particles. This promotes rapid ignition and flame Without With Two-stage combustion Fig. 7 Performance of HT-NR Series. Development of low burners has drastically lowered levels. Lower Through Improved TSC Ports Use of TSC in the burners further reduces. In this method, a combustion reaction under airpoor conditions is promoted between the burners and the TSC ports with the reaction being completed between the TSC ports and the furnace exit.

Hitachi Review Vol. 58 (29), No.5 191 It is well known that increasing the distance (HR) between the burners and TSC ports helps lower levels. However, assuming the same furnace height, making HR longer shortens the distance between the TSC ports and the furnace exit, resulting in lower combustion efficiency due to higher and UBC (unburned carbon). This trade-off relationship between and /UBC is a problem to be resolved. To overcome this trade-off, Hitachi has developed new multi-stage TSC ports and succeeded in promoting a combining of the TSC air and unburned gas. This new technology allows the same level of reduction to be achieved within a shorter distance. This can even prevent an increase in when the reducing zone is enlarged to lower levels. That is, the development of this new combustion method simultaneously lowers levels of both and. Fig. 8 shows the difference between the concepts used in the conventional and new combustion methods. The new multi-stage TSC port system requires at least two TSC port stages. Each TSC port tier corresponds to a particular region of the furnace and supplies air based on the distribution of unburned gas so as to promote mixing of unburned gas and air. Enlarging the distance between the burners and Conventional New method TSC ports also helps lower the level of thermal produced in the high-temperature combustion region and this complements the lower levels of fuel achieved by enlarging the reducing zone. Thermal is the generic term for nitrogen oxides produced from nitrogen in the air at high temperature. The temperature of the furnace gas gradually decreases with the height of the furnace due to cooling through radiation to the furnace walls. By optimizing the distance between burners and TSC ports, the furnace gas temperature at the TSC port locations can be controlled so that thermal does not increase. MBUSTION TEST RESULTS IN LARGE- SCALE TEST RIG Fig. 9 shows the results of combustion testing in a large-scale test rig. The test rig was fitted with HT- NR3 burners and the new TSC ports. Standard PRB (powder river basin) sub-bituminous coal was used as the test fuel. The level of was lowered by 4% compared to the conventional TSC method while maintaining the same level. Detailed measurements of chemical species and temperature in the furnace proved that the results matched the performance of the new TSC system predicted by numerical analysis. The new TSC system was installed in an existing 6-MWe-class utility boiler with the aim of lowering levels. A numerical analysis was carried out prior to the installation to predict the effects of Oxidizing zone 12 TSC ports (3) Enlarged reducing zone (2) TSC ports (Two-stage) (1) Burners (HT-NR3) level (% relative) 8 6 4 4 % 2 Conventional method (NR3+conventional TSC) New method (NR3+new TSC) Fig. 8 Concept of New TSC System. The new TSC system can simultaneously lower and levels. Fig. 9 Results of Combustion Testing on Large Test Rig. The new combustion method lowers levels without increasing.

Latest Low- Combustion Technology for Pulverized-coal-fired Boilers 192 Conventional configuration (NR3+conventional TSC) New configuration (NR3+new TSC) TSC ports Burners Concentration High Low Oxygen Oxygen Fig. 1 Example Numerical Analysis Results. The results show that the new multi-stage TSC ports drastically lower levels without changing the level of. changing from a conventional two-stage TSC system to the new TSC system. Fig. 1 shows the results of the analysis as represented by the distributions of gas compositions (oxygen, and ) along a vertical cross section of the furnace, and Fig. 11 shows the overall results in terms of the reduction in level. The locations of the existing two-stage TSC ports on the boiler were left unchanged and therefore the size of the reducing zone between the burners and the TSC ports remained as it was. The numerical analysis predicted that the level would be 12 lowered by more than 5% without any change in the level. This result depends on lowering the concentration of around the front and rear walls in the upper part of the furnace (red colored region in the figure). In the new TSC system, each tier of TSC ports corresponds to a particular region of the furnace and supplies air based on the distribution of unburned gas to promote the mixing of unburned gas and air. In this way, the new TSC system drastically lowers the level of. After the numerical analysis was completed, the new TSC system was installed on the actual boiler. Fig. 12 shows the results of demonstration testing., level (% relative) 8 6 4 2 Conventional method (NR3+conventional TSC) 6 % Developed method (NR3+new TSC) Fig. 11 Results of Numerical Analysis. The analysis indicates that the new combustion method can lower by more than 5% without changing levels. level (% relative) 2 Conventional method New method -2-1 Base (ppm) +1 +2 Fig. 12 Results of Testing on 6-MWe-class Boiler. Tests on an actual boiler demonstrated that the reduction in predicted by numerical analysis is also obtained in practical operation.

Hitachi Review Vol. 58 (29), No.5 193 These show that the reduction in levels is even greater than predicted by the numerical analysis. NCLUSIONS The requirement to protect the environment while still supplying cost-effective equipment is placing even greater demands on the development of low- combustion technology. At the same time, the types of coal used for power generation are becoming more diverse in order to ensure a reliable supply of energy. Our testing and numerical analysis work has established reliable evaluation parameters capable of dealing with the current standard of coal used in the power generation industry. Our combustion technologies have also been tested in practical applications where they have delivered excellent results. REFERENCES (1) F. Koda et al., Development of Pulverized Coal Low- Burner Using In-flame Reduction, Environmental Research 87 (Sep. 1992) in Japanese. (2) M. Taniguchi et al., Pyrolysis and Ignition Characteristics of Pulverized Coal Particle, J. of Energy Resources Technology 123, pp. 32-38 (21). (3) M. Taniguchi et al., A Reduced Reaction Model for Pulverized Coal Combustion under Fuel-Rich Conditions, Fuel 81, pp. 363-371 (22). ABOUT THE AUTHORS Kenichi Ochi Joined Babcock-Hitachi K.K. in 1995, and now works at the Boiler Engineering Department, Thermal Power Division. He is currently engaged in the design and development of combustion systems of boilers. Kenji Kiyama Joined Babcock-Hitachi K.K. in 198, and now works at the Boiler Engineering Department, Thermal Power Division. He is currently engaged in the design and development of combustion systems of boilers. Mr. Kiyama is a member of the Japan Society of Mechanical Engineers (JSME). Hidehisa Yoshizako, Dr. Eng. Joined Babcock-Hitachi K.K. in 1981, and now works at the Kure Research Laboratory. He is currently engaged in the development of combustion and heat transfer for thermal power boilers. Dr. Yoshizako is a member of the JSME. Hirofumi Okazaki Joined Hitachi, Ltd. in 1992, and now works at the Energy and Environmental Systems Laboratory, Power Systems Company. He is currently engaged in research on coal combustion systems. Mr. Okazaki is a member of the JSME. Masayuki Taniguchi, Dr. Eng. Joined Hitachi, Ltd. in 1987, and now works at the Energy and Environmental Systems Laboratory, Power Systems Company. He is currently engaged in research on coal combustion boilers and boiler analysis programs. Dr. Taniguchi is a member of the JSME.