WATERBUG@ INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007



Similar documents
Advantium 2 Plus Alarm

Model SRMD Setra Remote Monitoring Display

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

el-720 Carbon Dioxide Gas Leak Detector User s Guide

InHome Water Leak Detection Package

Wireless Indoor/ Outdoor Thermometer

ATS Overhead Table Shelf System INSTRUCTION MANUAL

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Owner s Manual & Safety Instructions

Single Station Remote Alarm

, User s Manual

CHAPTER 1. GETTING STARTED... 1

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

Owner s Manual & Safety Instructions

LCD5500Z / PKP-LCD v3.x Installation Instructions

Mold Alert... Operation Manual P0270

SURROUND MASTER. User Manual 1.0. English. Copyright 2012 Involve Audio

Model 5101, 5102, 5103SL, 5110, 5111, 5115 STEEL SECURITY SAFE. Read this manual carefully and never store it inside the safe!

2-Way Wireless Indoor Siren Installation Guide

Digital Fingerprint safe

IR Repeater. Operation Manual P8620

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

About Your NetBotz 4-20mA Sensor Pod

Part I - Installation

AGS. Owner's Manual. Xantrex Automatic Generator Start Control System

VK-250 WARRANTY REGISTRATION FORM


Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Nest Learning Thermostat Installation Guide. Installation step-by-step

TTL to RS232 Adapter User Guide

BroadBand PowerShield. User Manual

PK5500 v1.1 Installation Instructions

16/32 Channel 1U Rack Mount CCTV Power Supply

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Water Leak Detector BA/LDT Accessories Termination and Troubleshooting

Leak Detection System

PagePac PAGEPAL V

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

Destiny Shower Enclosure Installation Instructions

OAK WORKBENCH WITH 2 DRAWERS

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Global Water Instrumentation, Inc.

SOLAR ELECTRIC MODULE ES-124 & ES-62T Owners Manual and Installation Guide

Comfort Control Relay Panel (CCRP)

Telephone Controller INSTRUCTION MANUAL MODEL CT240-01

HotLok Pass Through Blanking Panel

Seven function digital multimeter

SingleNet Single Cable Control System

Humidity Sensor. Model HU-224/225

Single Port T1/E1 Tap

Automatic Phone-Out Home Monitoring Systems

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

Alarm Clock USER GUIDE

Load Cell Amplifier Module. Instruction Manual LCA

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Ultrasonic Distance Meter. Operation Manual

Mini-HDMI Series MINIATURE MULTIMODE FIBER OPTIC HDMI TRANSMISSION SYSTEM

POWER GEAR SLIDE OUT MANUAL

DCX300 - DCX400 - DCX600

Usage, Installation, Warranty and Service Information

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Indoor/Outdoor Color Camera with Built-in 2.4 GHz Wireless Transmitter, plus X10 controlled power supply, and Video Receiver.

Installation and Operation Guide for PD4100 Series Power Control Centers

Retractable Screen. Replacement Screen Instructions

LF-IRX. Limited Warranty LF-IRX. Remote Control Extender OWNER S MANUAL

RGC-IR Remote Gas Calibrator for IR400

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Copyrights 2010 Victron Energy B.V. All Rights Reserved

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

WIRELESS STATUS MONITOR

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

PixController, Inc. Wireless Digital PIR Sensor

Wireless Base Station Single and Multiple Headsets

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

BACnet Automation Interface Module (Network Version)

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

3 WATT LED SPOTLIGHT Model No. SLM

ANT1750F Multi-Directional Slim Digital Antenna / Antena multidireccional plana para interiores / Antenne numérique mince multidirectionnelle

Weather Radio Alarm Clock

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Kramer Electronics, Ltd. USER MANUAL. Rack Adapter Models: RK-1T2PT RK-2T1PT RK-3T RK-6T RK-9T RK-3TR RK-4PT RK-T2B RK-T2SB

Magnetic Stripe Reader-Writer. Magnetic Stripe Reader-Writer. RS232 & USB-RS232 Interface Quickstart Manual

Triple Threat 3-in-1 Game Table 3 IN 1 GAME TABLE

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

LiteAide OWNER'S MANUAL PREASSEMBLED AUTOMATIC SECURITY FLOODLIGHTS MOTION SENSOR SECURITY LIGHTING SYSTEMS

In-Line Filters and Coalescers with Automatic Drains

HIH-4000 Series Humidity Sensors

Installation and Operation Guide for PD4000 Series Power Control Center

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Signal Manager Installation and Operation Manual

4-in-1 SWIVEL TABLE. 54in (1.37m) CONTACT INFO Hours. Technical Support Monday to Friday (9:00am to 5pm EST) WARNING:

Acrylic Walls Installation Instructions

*PATENT PENDING. NS1100 / NS2200 Installation Manual & Owner s Guide

Installation Instructions

Atomic Alarm Clock model 13131W2

Transcription:

WATERBUG@ INSTALLATION / OWNERS MANUAL MODEL WB-200 PN # D-01 l-0007 REV B

INTRODUCTION Thank you for your purchase of the Winland WaterBug@ mode I WB-200. The WaterBug@ is completely electronic and is designed to detect only nonflammable conductive liquids (distilled water cannot be detected). The unit is not a self I I. I. P.- aa I I conrarnea warning aevrce. t-or proper operation it must be used in conjunction with a wireless transmitter, alarm system, etc. It is designed so that the control console mounts on the wall and the re.mote. sensors are placed in the locations where water seepage is most probable. Up to six remote sensors may be connected to one control console. A film of moisture forming a bridge between the 2 metallic contacts on any remote sensor is all that is needed for the unit to signal an alarm condition. The output on the WB-200 is non-latching, but will remain closed until the moisture bridge is broken. As sensitive as the WaterBug@ is, it will not alarm due to high humidity or condensation. The WaterBug is ideal for use in homes, offices, computer rooms, boats, etc. Several consoles may be wired in parallel to monitor an entire complex. INSTALLATION Locate the area where the WaterBug@ console is to be placed. Mark the position of the screw hole on the wall. Drive the mounting screw into the wall allowing approximately 3/l 6 between the screw head and the wall. Engage key slot on the back of the WaterBug@ case with the screw head and press down. Multiple sensors must be%ooked up in parallel to terminals 3 & 4. The remote surface sensors may be mounted

securely to the floor or a wall. NOTE: SEE THE WHITE INSTRUCTION SHEET FOR SENSOR MOUNTING IN- STRUCTIONS. Mounting the sensor(s) on a vertical surface enables you to monitor an area for rising water levels. This is, useful around basement sump pumps and other types storage and drainage systems. MONITORING FOR THE ABSENCE OF WATER of water The VV&erBug@ (Model WB-200) can be used to monitor for the absence of water. This is done by (a) mounting the probe at the desired minimum waterline and (b) using the set of contacts that are the opposite of what you would use if you were detecting the presence of water. / GND! SENSOR. 3 L PROBE SENSOR PROBE : 7. Cop TACTS The relay connections shown are for when power is applied to the unit. The power-on supervision so that if power is lost, the relay will provide an alarm unit provides output

TERMINAL BLOCK CONNECTIONS Relay contacts are accessible on the terminal block. The unit is in normal condition when power is applied and no moisture is being detected The unit is in alarm condition when water is detected by any one of the remote sensing probes. Note: When connecting DC power to the WB-200 be sure to observe polarity and test to see if the unit is operating properly. This may be done by forming a moisture bridge between two of the metallic contacts located on the sensor probe (see diagram) with a moistened finger or cloth. If the unit is not operating properly, check the polarity of the power supply connections. AC - Power input wires are interchangeable DC - Positive to position #I and negative to position #2 TEST PROCEDURE To test form a moisture bridge between the two metallic contact points (see diagram) with a moistened finger or cloth. If working properly, the WaterBug@ will activate the warning device +o which it is connected within approximately three seconds. Unit will reset automatically when the probe dries. Ordering Information: k Part No. 1043 art No. 1040 =art No. 1041 WaterBug@, Control console (includes 1 standard surface sensor) Additional standard sensors with 15 cable Addt l under carpet sensors with 15 cable

ONE YEAR LIMITED WARRANTY Winland Electronics, Inc. warrants that each product of its manufacture is free from defects in material and factory workmanship, when properly installed and operated under normal conditions according to the manufacturer s instruction. Manufacturer s obligation under this warranty is limited to correcting, without charge, at its factory any part or parts thereof which shall be returned to the factory, by the original retail purchaser, transportation charges prepaid, within one year after purchase and which upon examination shall disclose to the manufacturer s satisfaction to have been originally defective. Correction of such defects by repair to, or supplying of replacements for defective parts shall constitute fulfillment of all obligations to purchaser. Repair service performed bay the manufacturer after one year from date of purchase will be for a reasonable service charge. This warranty shall not apply to any of the manufacturer s products which have been subject to misuse, negligence or accident or which shall have been repaired or altered outside of the manufacturer s factory. Warranty is void if housing or cover is removed. Manufacturer shall not be liable for loss, damage, or expense directly or indirectly from the use of its product or from any other cause. THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE EXCLUDED, AS ARE ALL OTHER REPRESENTATIONS TO THE USER - PURCHASER, I4ND ALL OTHER OBLIGATIONS OR~LIABILITIES, INCLUDING LIABILITY FOR INCIDENTAL AND CONSEQUENTIAL DAMAGES, ON THE PART OF THE MANUFACTURER OR THE SELLER.. No person, agent or dealer is authorized to give any warranties on behalf of the manufacturer nor to assume for the manufacturer any other liability in connection with any of its products.

SPECIFICATIONS FOR WATERBUG@ WB-200 CONSOLE SIZE: 5 X 2.44 X 1.25 PROBE SIZE: (standard) 2 X 3 X 718 (under carpet probe) 2 X 3 X.18 POWER REQUIREMENTS: 12 VDC, 24 VDC (8-28 VDC) @ 35 ma 12 VAC, 24 VAC (8-28 VAC) @ 100 ma RMS MAXIMUM NUMBER OF SENSORS & MAXIMUM SENSOR CABLE RUN RECOMMENDED SENSOR CABLE COLOR/MOUNTING 1-2 SENSORS 200 MAX 3-6 SENSORS 100 MAX 18to24GA. Off-white / KEY SLOT OPERATING TEMPERATURE: Control: 32 to 1 30 F (0 to 54 C) Probes: 32O to 130 F (0 to 54 C) SENSITIVITY: Will not alarm due to high humidity or condensation RELAY RATING: 1 Amp at 24 VAC, resistive / 1 Amp at 30 VDC, resistive Form C contacts SPDT Mfg. in the U.S.A. byzb \(v 1 N LAN 13 1950 Excel Drive, Mankato, MN., 56001 ELECTRoNCSg lnc= Outside MN Phone: l-800-635-4269 Phone: (507) 6257231 FAX: (507) 387-2488 0 Winland Electronics, Inc. 1997

Standard Surface Sensor Part No. 1040 If the unit is to be bolted down as in a permanent installation, do not drill any hole outside of the innermost center recessed area. Damage to the internal wiring may result causing the unit to fail. Four Sens You must mount the sensor so these four steel contacts are against the surface to be monitored Drill in this innermost center circle only ALARM - WINLAND IkECTRONICS. INC. 1950 Excel Drive Mankato, MN., 56001 (507) 6257231 Instate (800) 6354269 Outstate u NO ALARM 0 WINLAND ELECTRONICS, INC. 1995 P N: D-0-00oQ Rev.