ALS TRIBOLOGY Engine Coolant Reference Guide



Similar documents
Fluids Analysis Program

How to read your Oil Analysis Report

Abrasive Solids Corrosion inhibitors and hard water components that have come out of the coolant solutions and may lead to premature water pump

NORKOOL Industrial Coolants

2014 Service Technician Training Program Closed Loop Systems

Cat S O SSM. Services. Understanding Your Results. Understanding Your: S O S Oil Reports S O S Oil Results S O S Coolant Reports S O S Coolant Results

FS Lubricants. Oil Analysis Program

Guidelines for Selecting and Maintaining Glycol Based Heat Transfer Fluids

3/5/2015. Oil Analysis Tests. Lubricating Oils. Six Functions of Lubricating Oil

Dispelling the Myths of Heat Transfer Fluids. Kevin Connor The Dow Chemical Company

COOLANT REQUIREMENTS FOR ENGINE COOLING SYSTEMS 2 GLOSSARY

petroleum technologies

CONVERTING A CLOSED-LOOP WATER SYSTEM TO A GLYCOL SYSTEM

Delo XLI Corrosion Inhibitor

Cooling System Maintenance Products COOLANT

WATER CHEMISTRY AND POOL WATER BALANCE

Periodic Table, Valency and Formula

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

Technical Training Guide Turbine Oil Condition Monitoring

Decomposition. Composition

LEAP SM Oil Analysis Program Saves Money with Consistent, Accurate Monitoring

COURSE 1020 OIL ANALYSIS WHY ATTEND

Corrosion Inhibitors in Antifreeze Coolants

It's in the details. JOST MINERAL GUIDE

Calculation of Molar Masses. Molar Mass. Solutions. Solutions

Pure Water. Isn t Hard to Find

What Can the OIL ANALYZERS Fluid Analysis Program Do For You?

OIL CONDITION MONITORING: AUTOMOTIVE ANALYSIS

APPENDIX B: EXERCISES

Oil Condition Monitoring

Oil Analysis Program ISO 9001: 2008 Certified.

EXTRACTION OF METALS

THE USE OF OZONE IN COOLING TOWERS

NALCO WT-1000 Closed System Corrosion Inhibitor

Balancing Chemical Equations Worksheet

LAB 5 - PLANT NUTRITION. Chemical Ionic forms Approximate dry Element symbol Atomic weight Absorbed by plants tissue concentration

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION C

WHAT IS IN FERTILIZER OTHER THAN NUTRIENTS?

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

Innovative Removal of Agricultural Related Water Pollutants in the Chesapeake Bay Watershed

Complexometric Titrations

How to Read an Oil Analysis Report by Jim Fitch

Periodic Table Questions

Total Suspended Solids Total Dissolved Solids Hardness

Texas Commission on Environmental Quality

B) atomic number C) both the solid and the liquid phase D) Au C) Sn, Si, C A) metal C) O, S, Se C) In D) tin D) methane D) bismuth B) Group 2 metal

Ion Selective Electrodes

Irrigation Water for Greenhouses and Nurseries

HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions

Coimisiún na Scrúduithe Stáit State Examinations Commission

FerroVer Method 1 Method to 3.0, 1.0 to 30.0 and 10.0 to mg/l Fe Powder Pillows

WRITING CHEMICAL FORMULA

Chapter 16: Tests for ions and gases

Series 53, 71, 92 and 149 Engines

Appendix D lists the Field Services Standard Operating Procedures. Appendix E lists the Biological Monitoring Standard Operating Procedures.

3. What would you predict for the intensity and binding energy for the 3p orbital for that of sulfur?

Metal Rescue Rust Remover Technical Data

Naming Compounds Handout Key

Experiment 5. Chemical Reactions A + X AX AX A + X A + BX AX + B AZ + BX AX + BZ

47374_04_p25-32.qxd 2/9/07 7:50 AM Page Atoms and Elements

Formulae, stoichiometry and the mole concept

The acknowledged leader in oil analysis since 1960 BASICS OF OIL ANALYSIS

Signum Oil Analysis Condition-Monitoring Fundamentals

Standard methods in water analysis

CHEMICAL REACTIONS OF COPPER AND PERCENT YIELD KEY

Pink X X X X X X X CAT Diesel Engine Antifreeze Coolant. Pink X X X X X X X Detroit Diesel PowerCool

Chem 1100 Chapter Three Study Guide Answers Outline I. Molar Mass and Moles A. Calculations of Molar Masses

Experiment 12- Classification of Matter Experiment

Wipe Analysis to Determine Metal Contamination on Critical Surfaces

General Chemistry Lab Experiment 6 Types of Chemical Reaction

Naming and Writing Formulas for Ionic Compounds Using IUPAC Rules

Environmental Technology March/April 1998

Basic Pool & Spa Care

ENGINE COOLING SYSTEM

SAND CAST CHILL CAST LM4 - TF

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Produced water from oil and gas production

USEPA 1 FerroVer Method 2 Method to 3.00 mg/l Fe Powder Pillows or AccuVac Ampuls

Hot Coolant To Cold Cash

Nomenclature and Formulas of Ionic Compounds. Section I: Writing the Name from the Formula

H 2 + O 2 H 2 O. - Note there is not enough hydrogen to react with oxygen - It is necessary to balance equation.

CHAPTER Naming Ions. Chemical Names and Formulas. Naming Transition Metals. Ions of Transition Metals. Ions of Transition Metals

Multiple Choice Identify the letter of the choice that best completes the statement or answers the question.

VHG Labs, Inc. Standards and Supplies for Spectrochemical Oil Analysis

Shell Fleet Management working with you to keep your fleet moving.

DEIONIZATION IN A "NUT SHELL"

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

COOLING WATER TREATMENT

Typical water pump claims and causes

CHAPTER 5: MOLECULES AND COMPOUNDS

MOLES AND MOLE CALCULATIONS

Anhydrous Fire Resistant Hydraulic Fluids using Polyalkylene Glycols

MAINTAINING YOUR SPA WATER

19.2 Chemical Formulas

Duramax Maintenance Info

Stoichiometry Review

IMPORTANT: Spa Owner, save this manual. Installer, leave this manual with the spa owner.

AGENDA: Understanding what makes Wind Different Wind Power Applications Application Requirements Windpower Oil Windpower Greases Summary

Transcription:

ALS TRIBOLOGY Engine Coolant Reference Guide Engine coolants are a mixture of, inhibitors, and water. Each formula is designed for specific protection and engine requirements. Mixing different coolants is not recommended and can compromise the coolant s general overall protective capability, resulting in decreased coolant life and damage to the cooling system and/or engine. The following is a reference guide to assist in understanding engine coolant data. Appearance Assessment The visual appearance of a coolant sample can say a lot about the condition of the coolant. In-service coolants should appear clear and bright, with no solid residues or sediment. Four visual assessments are conducted and reported. Appearance Assessment Possible Result Clarity Clear Appears hazy or opaque Degraded or contaminated engine coolants or a mixture of incompatible coolant types Check shelf life of the coolant; check coolant handling practices Color Clear, bright, and representative of the original engine coolant color Brown could indicate improper mixing of different coolants Decreased coolant protection Verify original coolant color of product in use; if brown was reported, check coolant handling practices Visible Sediment None Presence of sediment is typically indicative of additive fallout, corrosion, rust, scale buildup, or other contaminants Water pump and seal deterioration, liner pitting, copper and aluminum corrosion, plugged oil cooler and radiator; poor sampling technique. Add a non-sca filter for ELC coolants; add an SCA filter to conventional coolant systems Visible Petroleum Layer None Indication of fuel or oil contamination will be observed usually in the form of a separated layer Combustion gas blowby into the coolant, leaking oil cooler; poor sampling technique Check for any seal failures and system integrity Page 1

ph Indicates the level of acidity (low ph) or alkalinity (high ph). Typical baseline ph values of a coolant can vary but remain relatively consistent unless the coolant and/or cooling system has been compromised. Allowing the coolant to become acidic will lead to metal corrosion in the cooling system, so it is critical to monitor. One key item that can affect coolant is age; review storage practices and make sure coolant stock is properly rotated. ph Low ph High ph ELC Low ph (< 7.5 ) Conventional Low ph (< 8.5 ) ELC High ph ( > 9.5); Conventional High ph (>11.0) Check coolant volume ELC Engine Coolant and Conventional Engine Coolant Extended Life 7.5 9.5pH Conventional 8.5 11.0pH Low ph can lead to metal corrosion Air leaks will lower ph Improper coolant volume Shelf life of coolant, age will lower the ph Under additized SCA concentration (conventional coolant) Mixed coolant types Over additized SCA concentration Check for air leaks Pressure check radiator cap Check SCA filter and replace if needed (conventional coolant only) Electrical grounding issues (if coolant has a burnt smell) Combustion gas leak if ph is below 7.0 Remove SCA filter when ELC coolants are in use, this will add ph buffer and raise the ph Drain, flush, refill then resample Freeze Point / Percent Glycol Concentration Freeze point is a critical element in coolant analysis. If improper concentration is maintained, it can lead to decreased protection or over concentration of the inhibitor, both of which can lead to cooling system problems and engine damage. Coolants are typically available as a concentrate or as pre-diluted with several different ratios of concentrations. However, freeze points in North America should be maintained between -15 F and -60 F (equivalent to 40% 60% concentration). Glycol concentration (ethylene or propylene) is used to suppress the freeze point and elevate the boiling point of the coolant. The ratio required depends on the environment in which the equipment is operating. Always ensure that equipment and environmental requirements are met. Page 2

Glycol Concentration Low Glycol Concentration High Glycol Concentration Check proper coolant volumes Percent Glycol 40% to 60% Low Glycol ( < 40 % ) Freeze Point ( > -15 F ) Confirm adequate protection requirements for application Improper adjustment with water High Glycol ( > 60 %) Freeze Point (< - 60 F) Too high indicates over use of concentrate or water is boiling off This can reduce heat transfer properties resulting in cavitations and liner pitting Pressure check radiator cap Confirm bulk source of coolant for inadequate concentration If the coolant has been over diluted or under diluted, by manufacturer s guidelines, take corrective action by adjusting the or water level following the manufacturer s recommendations. The use of deionized or distilled water is recommended when needing to utilize water to adjust concentration. Conductivity / Total Dissolved Solids (TDS) This is a concern in heavy duty, conventional coolants because of the practice of adding Supplemental Coolant Additives (SCAs), which can lead to overloading of these, resulting in water pump failures and cooling system corrosion. It measures the coolant s ability to resist carrying an electrical charge. Low TDS High TDS TDS 20000 max Normal Improper source water, over concentration of SCAs Confirm water source; distilled or deionized is recommended Check for improper SCA filter drain, flush and refill Nitrites For many years, heavy duty coolants contained nitrites to protect against cavitation and corrosion. However, with the advancements in technology, there are now many coolants that are nitrite-free because the organic acid based technology provides protection without the need for nitrites. Conversely, engine manufacturers require either nitrites or nitrite-free coolants, so it is important to ensure the proper coolant formula is in use to meet the equipment manufacturer s requirements. For proper diagnostic review, always provide the coolant in use in order to properly diagnose the nitrite level of the coolant. Page 3

Nitrites Low Nitrites High Nitrites Check the coolant mixture, if under or over concentrated, this will impact the nitrite level when present If low, look at nitrate level; if ph has dropped, check for head gasket leaks, low coolant volumes, and pressure check radiator cap Nitrite Initial coolant concentration typically: > 1200 PPM Nitrite only formulas > 300 PPM for nitrite/ molybdate formulas < 25 for nitrite free Under concentrated with Under concentration of SCAs for conventional coolants Over concentration of Over concentration of SCAs for conventional coolants Rapid depletion could indicate overheating of the cooling system and localized hot spots, check; this will occur along with an increase in ates Rapid depletion could also indicate electrical shorts; check grounding, coolant will have a burnt smell If using ELC, check for a pre-charged SCA filter and replace with a non-precharged filter If nitrites are low, but carboxylate acid inhibitor passed, resample at next service interval Drain 50% of system and add 50/50 coolant, resample Carboxylate Acid Technology In extended life coolants, the previous mineral based additives have been replaced with carboxylic and fatty acids, allowing the coolant life to be greatly extended and enhancing coolant system protection. However, not all formulas are the same! There are a variety of signature formula s available on the market today, each formulated for equipment requirements and/ or longevity differences. Because there are a variety of formulas available on the market, it is wise to confirm that the right coolant for your equipment was chosen. Most, if not all, coolants allow for some acceptable dilution without compromising the inhibitor s capability to protect. If the coolant inhibitor has been compromised by diluting, mixing, etc., beyond the manufacturer s recommended allowable dilution, follow the manufacturer s corrective action and adjust the inhibitor concentration. Maintaining proper inhibitor levels is key to maintaining proper cooling system protection. Page 4

Carboxylate Acid Low OAI High OAI Adjust coolant concentration; if over concentrated, add proper source water; if under concentrated, add concentrate; check freeze point and resample at next service interval OAI Passing level depends on the initial extended life coolant s inhibitor level formula Under concentrated with Coolant is brown possible improper conversion from conventional to extended life Over concentrated with If the inhibitor level has been underdiluted, by manufacturer s guidelines, take corrective action by adjusting the inhibitor level following the manufacturer s recommendations. If the coolant was improperly mixed with conventional and extended life coolant, significantly affecting the inhibitor level s protection capability, either drain and flush or contact your OEM for corrective action. Other Ion Chromatography Data If the coolant has been over-diluted, by manufacturer s guidelines, take corrective action by adjusting the inhibitor level following the manufacturer s recommendations. Ion Chromatography Results Source Chlorides Glycolates Outside contaminants and can come from improper source water or air leaks. It has the potential to form acids and cause corrosion. It can also come from coolant degradation due to aging. Is among a group of acids that form as coolant degrades. This will also increase when overheating or hot spots are occurring. As this acid increases, iron corrosion is at risk. Molybdate Provides protection of cast iron corrosion and cavitations. Nitrates Phosphates Sulfates Provides protection of light alloys also provides aluminum and solder protection. If nitrites are being exposed to air, they will chemically transform to nitrate when this occurs look for air leaks. ph buffer utilized in some coolant brands and provides iron corrosion protection. Over treating the cooling system can lead to sediment detection resulting in possible plugged oil cooler or radiator. Some engines that are aluminum must be phosphate free, check OEM requirements before using a phosphate coolant. This contaminant can combine with calcium to create scale. This can also indicate coolant degradation due to aging or improper source water is being used. Page 5

Coolant Spectrochemical Data A series of specific elements are measure for additive, wear, and improper source water contamination. Coolant Spectrochemical Data Aluminum (Al) Boron (B) Calcium (Ca) Copper (Cu) Iron (Fe) Lead (Pb) Magnesium (Mg) Molybdenum (Mo) Phosphorus (P) Potassium (K) Silicon (Si) Sodium (Na) Silver (Ag) Tin (Sn) Zinc (Zn) Additive Elements Wear Elements Water Elements Page 6