Benchtop Test Chambers Temperature and Humidity



Similar documents
Environmental Chambers For Solar Panel Testing

Advanced Test Equipment Rentals ATEC (2832)

Climate Test Chamber. System Weiss. Type WK3-2000/40

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

USER S MANUAL HSC-24A

VTS³ and VCS³ Stress Screening Systems. More Power for Maximum Quality Assurance

Freezers - Ultrafreezers. Platilab & Irilab Series

Incubator with mechanical convection

Network Solutions CAT.NO.E12181-Z1210

Facility Requirements for the elan2 Office Liquid Nitrogen Generator

Material test chamber with mechanical convection

Heating oven with mechanical control

CE6500 Energy Recovery Ventilator


08 FRIDGES & FREEZERS

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Heating oven with mechanical convection

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Electronic Control Devices The European Product Catalogue 2007

STERILIZERS, LABORATORY DRYING OVENS

CelCulture. CelCulture CO2 Incubator Model CCL-170_-_. CO2 Incubator with Integrated Cooling System Solution for Highly Specialized Applications

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Rittal White Paper 305: Selecting Air Conditioners for Industrial Enclosures By: Judith Koetzsch Mark Corcoran, Editor

MUELLER FALLING FILM CHILLERS

Commercial Gas Water Heaters

Wine Cooler with Thermo-Electric Cooling & Heating Technology

REGULATORS 175/153 Series

Climate chamber with illumination

Incubators, cooled incubators, drying ovens, sterilizers, climatic chambers

Refrigerators - Freezers. Ekofrigolab & Ekobasic Series

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Sanitary Type Electronic Flow Switches

PORTABLE AIR CONDITIONER

LABOKLAV. Autoclaves Made in Germany.

Electronic Flow Switches

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Thermo Scientific Heratherm Microbiological Incubators. Safe, easy and efficient

Element D Services Heating, Ventilating, and Air Conditioning

T7079A,B Solid State Remote Temperature Controllers

Clinic Washer-Disinfectors. Washer-Disinfector Line

Doc Ref: baselayer.com 2015 BASELAYER TECHNOLOGY, LLC

Innovent LASER Packaged Fresh Air Conditioning Units

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

IFC 070 Technical Datasheet

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

The formula for finding CFM is: CFM = BTUH OUTPUT_ Temp Rise (ACF)* *Altitude correction factor below 1000ft = 1.08

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Air Conditioner Water Heater - A Product of HotSpot Energy LLC

Commercial Semi-Instantaneous Water Heaters

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Laboratory & Scientific Line. Horizontal Steam Sterilizers

PORTABLE AIR CONDITIONER

Cooling Capacity CFM in. w.c. (125 Pa)

RPV - RP - RA air handling units

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

Silicone oil is as the medium and the drying effect is uniform. The Temperature error is less than or equal 1.

In-Line Electronic Flow Switches

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Operating Instructions Split System Air Conditioner

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

Cooling Capacity CFM in. w.c. (125 Pa)

Choosing Close-Coupled IT Cooling Solutions

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

BD150 INDUSTRIAL DEHUMIDIFIER USER MANUAL

Air conditioning unit Saphir vario. 2. Product information for the new Truma air conditioning unit. Comfort on the move

Power consumption (kw)

STD - STANDARD VERSION extended possibilities reasonable price wide range of optional equipment

F9MXE. Product Specifications

Brownie s. Tankfill. and. NitroxMakers

Commercial Gas Furnace Upflow

Cooling Capacity CFM in. w.c. (125 Pa)

Standard Features: Options:

Chilled Water Precision Air Conditioner For Critical Application

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

Agilent 87421A/87422A Power Supply

SIOUX HYBRID WATER HEATER

GenStore Archive Cabinet

Dehumidification Frequently Asked Questions

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

air conditioners how to choose a cooling system

Research RF Sputtering Packages

Low Cost. Lower Energy Costs. Higher Efficiency.

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

Lava. Precision Solutions. Site Planning and Installation Guide

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

Benefits of Cold Aisle Containment During Cooling Failure

Intelligent Vibration Monitoring

Cost Estimation for Materials and Installation of Hot Water Piping Insulation

Transcription:

Benchtop Test Chambers Temperature and Humidity

Compact chambers with extended testing ranges ESPEC's Criterion benchtop chambers offer two sizes and a variety of testing ranges. With many options, they can be configured to accommodate your specific requirements. Their narrow footprint saves valuable lab space. 2

Benchtop Features Models save valuable lab space ESPEC introduces our expanded Criterion Series. With a narrower footprint and increased performance, these test chambers provide an economical and space-saving solution for cramped labs needing to do a variety of temperature (and humidity) testing. Size Comparison 1.5 cu. ft. 4 cu. ft. 24 All of the Criterion models have a 19.5 inch wide interior, which is 3.5 inches more than traditional benchtops, yet the exterior is 20% narrower. The four cubic foot models have the largest workspace found in a benchtop unit, while maintaining the smallest exterior footprint. For additional space savings, the refrigeration system ventilates out the top, and utility connections are on the sides, thus allowing installation directly against a wall. With the electrical system behind the hinged control panel, minimal space allowance is required on the sides, as well. Big chamber performance The extended temperature ranges of the Criterion series make testing at extreme conditions possible without buying a larger, stand-alone chamber. Units are available that go as cold as -70 C. The four cubic foot models also offer a choice of humidity control. With a range from 10 to 95%, you can maximize your testing options. A low humidity system can extend this range even farther. (See humidity chart on page 7 for details.) 12 The Criterion series has two chamber sizes: 1.5 and 4 cubic feet. The interior width for both sizes is 19.5 inches. The exterior footprint for both sizes is the same, just 30.25" x 33.5". Temperature Comparison Temperature Range Comparison Extreme temperatures possible ( C) BTZ & BTX all models BTU & BTL all models 11 19.5 19.5-50 0 50 100 150 200-70 180-20 180 The BTZ & BTX models have extended cold temperature ranges without requiring liquid nitrogen. The BTU & BTL still offer sub-freezing testing capability. 15 Faster temperature changes The Criterion series can cycle temperatures at rates up to 5 C/minute without requiring liquid nitrogen. Significant test time can be saved, as well as creating added thermal stress on your samples. Performance Comparison 180 150 100 50 BTZ-175: 5 C/m BTZ-133: 3 C/m To demonstrate performance, ESPEC uses the international standard IEC 60068 3-5 measured at the supply air. Temperature cycles are run from hot to cold extremes, and the middle 80% of the transition is timed to determine performance. Your actual cycling results will vary depending on methodology, including the start and end temperatures, and the amount of samples loaded. 0-50 -70-100 0 30 60 90 120 150 180 min. The Criterion chambers respond quickly to setpoint changes. The BTZ-175 can save 30 minutes or more per cycle. 3

Benchtop Features Space-saving design An innovative new layout of system components helps make Criterion chambers have the smallest footprint. Keeping the refrigeration compressors and blower fan to the back of the chamber also reduces noise to the room. Useful safety features To protect from the risk of overheating, there are three levels of protection: 1. Settable within the programmer 2. An independent settable monitor 3. A thermal fuse In addition, a specimen power terminal allows the user to safely operate powered equipment inside or with the chamber. If the chamber is shut down, the interlocked device will also be shut down. Highly reliable operation The Criterion platform has been reengineered from the ground-up to be consistent, reliable, and easy to maintain. ESPEC stands behind the chambers with a comprehensive one-year parts and on-site labor warranty. Quality cabinet construction ESPEC is meticulous about making a chamber that is more than just functional. Stainless steel exterior and interior Rounded corners for easy cleaning Full thermal break around doorframe and door Rotating door latch is easy and secure Dual-layer insulation of fiberglass and expanded foam for thermal integrity One 2" (50mm) diameter cable port on the left, with an impervious, flexible silicone plug Easy lift-off service panels Floor drain and drip-tray under the doorframe The chamber's fan continuously circulates conditioned air from the test area to the plenum (to the right of the test area), where the heaters, cooling coil, and humidity inlet are located. (BTX-475 model shown). A nonmetallic thermal break around the door and doorframe stops transfer of heat/ cold to the exterior (BTZ-133 model shown). 4

Instrumentation Watlow F4T controller The F4T is the newest programmer/controller from Watlow, now with an easy to use touch-screen. It stores up to 40 different test profiles. Programming steptypes available are: ramp, soak, jump/repeat, auto-start, and end. The F4T includes an Ethernet interface with familiar Modbus protocol. Optional software will be available for full remote management and datalogging capability. One event relay with external output terminal is included for activating other equipment during operation. Options Cabinet Options Humidity Options Roll-around cart with storage cabinet (suitable for chart recorder placement) Cable ports: 2", 4", or 6" diameter (50, 100, or 150mm). One 2" port is standard on the left wall. Adjustable stainless-steel shelving Heated viewing window with interior light, 6"x6" (6"x12" for 4 cubic foot models) Solid-state humidity sensor in place of wet-bulb External water supply tank with recirculating capability Water supply tank system as a roll-around cart for the unit Water filter (de-ionizing type) Extended low humidity range to 5 C/15% (see chart, page 7) Instrumentation Options Cart Cable port Window Operational Options Web Controller for network access via web browser Paperless recorder Liquid nitrogen (LN 2 ) injection boost for faster cooling RS-485 or RS-232 serial interface Emergency stop 'mushroom' button Chino paperless recorders with Ethernet and email alarms Safety features for testing lithium ion battteries or other potentially volitaile products. Honeywell circular-chart recorders Control sensor outputs for customer use ESPEC humidity system expertise Controlling humidity in a small environmental chamber can be especially challenging. ESPEC's expertise in humidity control brings intelligent design that is carefully integrated into the BTL-433 & BTX-475. The humidity subsystems are designed for reliability, convenience, and performance: An external steam generator allows expanded range and is easy to maintain. A separate de-humidification coil improves low humidity control and range. The wet-bulb humidity sensor is an accurate primary measurement method. It is economical, easy to maintain, and reliable because it has no risk of failure due to over-saturation. Direct water supply connection is standard, with options for water filtering and external tank. Steam generator removes for easy cleaning 5

SPECIFICATIONS - 1.5 cu. ft. MODELS Model BTZ-133 BTZ-175 BTZ-175E BTU-133 Temperature Range -70 to 180 C (-100 to 354 F) -20 to 180 C (-4 to 354 F) Change Rate (per IEC 60068 3-5) 3.5 C/m heat-up 3 C/m cool-down 5 C/m heat-up 5 C/m cool-down 2 C/m heat-up 1.6 C/m cool-down Temperature Fluctuation ± 0.5 C per IEC 60068 3-5 Temperature Gradient ± 1.5 C (up to 100 C) per IEC 60068 3-6 Live Load Capacity 160 W to -40 C 300 W to -40 C 200 W to 0 C Interior Volume 1.5 cu. ft (42 L) Interior (W x D x H) Exterior (W x D x H) 19.6" x 11" x 12" (500 x 280 x 300 mm) 30.25" x 33.5" x 34" (770 x 850 x 865 mm) Heaters 500 W 1000 W 500 W Refrigeration 1/3-hp x2 (cascade) 3/4-hp x2 (cascade) 1/3-hp x1 (single-stage) Air Circulation 100 cu. ft./min. (2.8 m 3 /min.) Site Requirements Electrical Supply 115V 1ph 60Hz 20A 208/230V 1ph 60Hz 20A 230V 1ph 50Hz 20A 115V 1ph 60Hz 20A Weight 300 lbs. (136 kg) 400 lbs. (181 kg) 275 lbs. (125 kg) Sound Level 65 dba (1 meter away from door) Heat to Room 5,100 BTU/Hr 9,000 BTU/Hr 3,600 BTU/Hr Gravity Drain Room Temperature 3/8" NPT Performance assured when room temp. is steady, 18 to 27 C (65 to 80 F) Chart shows example of heating and cooling ramps during IEC 60068 3-5 qualification (see page 3). 180 150 100 BTZ-133: 3 C/m BTZ-175(E): 5 C/m BTU-133: 1.6 C/m 50 0-35 -50-70 -100 0 60 120 180 240 300 350 min. 1.5 cu. ft. (this page) 4 cu. ft. (next page) Accessories included with each chamber: Cable port plug Power cable with plug (115V is NEMA 5-20, 208/230V is NEMA 6-20) Box of wet-bulb wicks (BTL/BTX) Operations & programmer manual, parts list & schematics on CD. 6

SPECIFICATIONS - 4 cu. ft. MODELS Model BTL-433 BTX-475 BTZ-475 BTU-433 Temperature Range -20 to 180 C (-4 to 354 F) -70 to 180 C (-100 to 354 F) -20 to 180 C (-4 to 354 F) Change Rate (per IEC 60068 3-5) 1.5 C/m heat-up 1.2 C/m cool-down 2.75 C/m heat-up 2.5 C/m cool-down 1.5 C/m heat-up 1.2 C/m cool-down Temperature Fluctuation ± 0.5 C, per IEC 60068 3-5 Temperature Gradient ± 1.5 C (up to 100 C), per IEC 60068 3-6 Live Load Capacity 160 W to 0 C 300 W to -40 C 160 W to 0 C Humidity Range 10 to 95% RH, per chart below - Humidity Fluctuation ±5% RH per IEC 60068 3-5 except measured in supply air - Interior Volume 4 cu. ft (110 L) Interior (W x D x H) Exterior (W x D x H) 19.6" x 15" x 23.6" (500 x 380 x 600 mm) 30.25" x 33.5" x 46" (770 x 850 x 1170 mm) Heaters 500 W 1000 W 500 W Refrigeration 1/3-hp x1 (single-stage) 3/4-hp x2 (cascade) 1/3-hp x1 (single-stage) Air Circulation 200 cu. ft./min. (5.6 m 3 /min.) Site Requirements Power Supply 115V 1ph 60Hz, 20A 208/230V 1ph 60Hz 20A 115V 1ph 60Hz, 20A Weight 325 lbs. (147 kg) 550 lbs. (250 kg) 325 lbs. (147 kg) Sound Level 65 dba (1 meter away from door) Heat to Room 3,600 BTU/Hr 9,000 BTU/Hr 3,600 BTU/Hr Gravity Drain 3/8" NPT Humidity Water Supply Supply: 3/8" NPT, 30-50 psig Typical usage: 0.5 gallon/day Purity required: 0.2 μs/cm to 10 μs/cm - Room Temperature Performance assured when room temp. is steady, 18 to 27 C (65 to 80 F) Chart shows example of heating and cooling ramps during IEC 60068 3-5 qualification (see page 3). Controlled humidity range for BTL-433 & BTX-475 models (without live load). Optional low humidity range shown in red. 180 150 BTL / BTU-433: 1.2 C/m BTX / BTZ-475: 2.5 C/m 95 80 100 50 0-20 -50-70 -100 0 60 120 180 240 300 350 %RH 60 40 20 5 / 15% 20 40 Temp. in C 60 80 85 7

www.espec.com sales@espec.com 4141 Central Parkway, Hudsonville, MI 49426, U.S.A. Tel: 1-616-896-6100 ESPEC EUROPE GmbH Germany www.espec.de info@espec.de Tel: 49-89-1893-9630 ESPEC ENVIRONMENTAL EQUIPMENT (SHANGHAI) CO., LTD. China www.espec.cn Tel :86-21-51036677 ESPEC SOUTH EAST ASIA SDN. BHD. Malaysia www.espec.com.my Tel: 60-3-8945-1377 ESPEC ENGINEERING (THAILAND) CO. LTD. Thailand Tel: 66-3-810-9533 www.espec.co.jp/english 3-5-6, Tenjinbashi, Kita-ku, Osaka 530-8550, Japan Tel: 81-6-6358-4741 DANGER Not for use with specimens which are explosive or flammable, or which contain such substances. To do so could be hazardous, as this may lead to fire or an explosion. BTL-BTZ CRITERION (A) December 2015