GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2



Similar documents
GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

Radiochromic Film. David F. Lewis, Ph.D. Senior Science Fellow Advanced Materials Group International Specialty Products

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

Performance of the Vidar Red LED Dosimetry Pro Advantage : A scanner optimized for use with GAFCHROMIC EBT Dosimetry Film.

Multi-Channel Radiochromic Film Dosimetry. Adapted from A.Micke Spain, April 2014

Measuring Patient Exposure in Interventional Radiology

Azam Niroomand-Rad, PhD Georgetown University Medical Center Washington D.C. AAPM 41st Annual Meeting Continuing Education Courses

Comparison of Epson scanner quality for radiochromic film evaluation

Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification

Using the Spectrophotometer

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

2 Spectrophotometry and the Analysis of Riboflavin

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Manual for simulation of EB processing. Software ModeRTL

... complement Information for Processing

DNA Detection. Chapter 13

A Guide to. Understanding Graphic Arts Densitometry

What s in the Mix? Liquid Color Spectroscopy Lab (Randy Landsberg & Bill Fisher)

FUJICOLOR CRYSTAL ARCHIVE DIGITAL PAPER TYPE DPII

Color Management Terms

KODAK EKTACHROME 100 Professional Film

Submitted to Radiation Measurements INVESTIGATION OF OSL SIGNAL OF RESISTORS FROM MOBILE PHONES FOR ACCIDENTAL DOSIMETRY

How To Understand Light And Color

Standard Test Method for Classification of Film Systems for Industrial Radiography 1

Chemistry 111 Lab: Intro to Spectrophotometry Page E-1

Digitization of Old Maps Using Deskan Express 5.0

Experiment #5: Qualitative Absorption Spectroscopy

Computer Vision: Machine Vision Filters. Computer Vision. Optical Filters. 25 August 2014

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

ICC Recommendations for Color Measurement

KODAK PLUS-X AEROGRAPHIC Film 2402

Use of 3D Printers in Proton Therapy

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Improved predictive modeling of white LEDs with accurate luminescence simulation and practical inputs

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Dimensional Change Characteristics for Printed Circuit Board Films

Electromagnetic Radiation (EMR) and Remote Sensing

Scanners and How to Use Them

Measurement of the effect of biomass burning aerosol on inhibition of cloud formation over the Amazon

2C: One in a Million. Part 1: Making solutions. Name: Section: Date: Materials

Principle of Thermal Imaging

GRID AND PRISM SPECTROMETERS

Green = 0,255,0 (Target Color for E.L. Gray Construction) CIELAB RGB Simulation Result for E.L. Gray Match (43,215,35) Equal Luminance Gray for Green

Overview. What is EMR? Electromagnetic Radiation (EMR) LA502 Special Studies Remote Sensing

EPSON SCANNING TIPS AND TROUBLESHOOTING GUIDE Epson Perfection 3170 Scanner

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

The accurate calibration of all detectors is crucial for the subsequent data

Radiation Curable Components and Their use in Hard, Scratch Resistant Coating Applications

2 Absorbing Solar Energy

Basic Specifications. Electrical. EPSON Perfection Color EPSON MatrixCCD TM line sensor. device Effective pixels

Radiation-Resistant Single-Mode Optical Fibers

KODAK PANATOMIC-X AEROGRAPHIC II Film 2412 KODAK PANATOMIC-X AERECON II Film 3412

Light Waves and Matter

Solar Cell Parameters and Equivalent Circuit

Introduction to Color Process Monitoring For Minilabs

DOSIMETRIC CHARACTERIZATION OF DYED PMMA SOLID DOSIMETERS FOR GAMMA RADIATION

Spectrophotometry Practical Lesson on Medical Chemistry and Biochemistry

THE NATURE OF LIGHT AND COLOR

Reprint (R22) Avoiding Errors in UV Radiation Measurements. By Thomas C. Larason July Reprinted from Photonics Spectra, Laurin Publishing

Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES

DSM155 Digital LED Light Meter User s Manual DSM155

Importing Rayfiles of LEDs from OSRAM Opto Semiconductors Application Note

Review Vocabulary spectrum: a range of values or properties

Agfa Materials Printed Circuit Boards. High Resolution Film. HRR & HRO Technical Information

Effect of ph on the Size of Gold Nanoparticles

Absorbance Spectrophotometry: Analysis of FD&C Red Food Dye #40

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

ING LA PALMA TECHNICAL NOTE No Investigation of Low Fringing Detectors on the ISIS Spectrograph.

Reaction Stoichiometry and the Formation of a Metal Ion Complex

Passive Remote Sensing of Clouds from Airborne Platforms

Back to Basics Fundamentals of Polymer Analysis

Rodenstock Photo Optics

Lab #11: Determination of a Chemical Equilibrium Constant

Integrating the Solar Spectrum

Upon completion of this lab, the student will be able to:

A Beer s Law Experiment

UNITED STATES DEPARTMENT OF COMMERCE National Institute of Standards and Technology Gaithersburg, MD Ionizing Radiation Division

CONSERVATION AND LIGHTING

Using Spectrophotometers to Examine Photosynthetic Rates Under Various Qualities of Light

Outline. Quantizing Intensities. Achromatic Light. Optical Illusion. Quantizing Intensities. CS 430/585 Computer Graphics I

Common Defects in Digital Printing. Paul Geldenhuys & Amir Shapira January, 2009

6) How wide must a narrow slit be if the first diffraction minimum occurs at ±12 with laser light of 633 nm?

Film Scanner The term Film Scanner can refer to a dedicated slide and negative film scanner or to a capture type scanner.

Neuro imaging: looking with lasers in the brain

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Enhancement of Breakdown Strength and Energy Density in

Spectroscopy Using the Tracker Video Analysis Program

Name Class Date. spectrum. White is not a color, but is a combination of all colors. Black is not a color; it is the absence of all light.

Photography of Cultural Heritage items

Lumogen F. Technical Information. Collector dyes. Colorants and Graphic Systems. TI/P 3201 e (9125) November 1997

FUJICHROME 64T TYPE II Professional [RTPII]

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

The Determination of an Equilibrium Constant

One example: Michelson interferometer

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

FTIR Instrumentation

Transcription:

GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2 WARNING: Store below 25ºC Store away from radiation sources Do not expose film to sunlight Handle film carefully, creasing may cause damage Do not expose to temperatures above 50ºC CONTENTS: 5 sheets, 8 x 10

GAFCHROMIC HD-V2 Dosimetry Film GAFChromic HD-V2 is a radiochromic dosimetry film designed for the quantitative measurement of absorbed dose of high-energy photons. As a self-developing film, HD-V2 is a perfect fit for the processorless environment. Since radiochromic film requires no post-exposure processing, there are no chemicals to dispose of and the film can be handled and used without need of a darkroom. Key technical features of GAFCHROMIC H-VD2 include: Dynamic dose range: 10 Gy to 1000 Gy Develops in real time without post-exposure treatment; Energy-dependence: minimal response difference from 100keV into the MV range; Near tissue equivalent; High spatial resolution can resolve features to 5μm, or less; Active coating exposed for detection of low energy photon and electron Proprietary new technology incorporating a marker dye in the active layer: Enables non-uniformity correction by using triple-channel dosimetry Decreases UV/light sensitivity; Stable at temperatures up to 60 C; The most important feature of GAFChromicC HD-V2 compared to the previous generation HD810 dosimetry film is the incorporation of a yellow marker dye. Used in conjunction with an rgb film scanner and FilmQAPro software 1, the marker dye in HD-V2 film enables all the benefits of triple-channel dosimetry 2. Using the marker dye feature is not mandatory asdosimetry can still be done using a single color channel (preferably the red channel), but you give up all the advantages of the triple-channel method that compensates for thickness differences of the film s active layer. To learn more about FilmQAPro software and triple-channel film dosimetry, visit www.filmqapro.com. As shown in Figure 1, the structure of GAFChromic HD-V2 film is asymmetric. The film is comprised of an active layer, nominally 12μm thick, containing the active component, marker dye, stabilizers and other components giving the film its energy-independent response. The thickness of the active layer may vary slightly from batch-to-batch. The active layer is coated on a clear, 97 μm polyester substrate. Active Layer - 12 microns m Polyester Substrate - 97 microns Figure 1: Configuration of GAFChromic HD-V2 Dosimetry Film

There have been indications that the response measurements made with a scanner or densitometer may be dependent on which side of the film is facing the light source. W h i l e t h e d i f f e r e n c e m a y b e v e r y s m a l l it is advised t o b e c o n s i s t e n t w i t h w h i c h s i d e o f t h e f i l m f a c e s t h e l i g h t s o u r c e. To help distinguish between the sides, sheets of GAFChromic HD-V2 film are marked with a small slit near one corner. When film is viewed in landscape orientation with the slit in the top right corner as shown in Figure 2, the active layer is on the side facing the viewer. Figure 2: GAFChromic HD-V2 film in landscape view showing slit in top right corner. SPECIFICATIONS Property Configuration Size Dynamic dose range Energy dependency Dose fractionation response GAFChromic HD-V2 Film Active layer on 3.8 mil (97 µ) clear polyester substrate 8 x 10, other sizes available upon request 10 to 1000 Gray <5% difference in net density when exposed at 1 MeV and 18 Mev <5% difference in net density2 for a single 100 Gy dose and five cumulative 20 Gy doses at 30 min. intervals Dose rate response <5% difference in net density2 for 10 Gy exposures at rates of 3.4 Gy/min. and 0.034 Gy/min. Stability in light Stability in dark (preexposure stability) Uniformity <5x10-3 change in optical density per 1000 lux-day <5x10-4 optical density change/day at 23 C and <2x10-4 density change/day refrigerated Better than 3% in sensitometric response from mean; dose uniformity better than ±2% with FilmQAPro and triple-channel dosimetry

Absorption PERFORMANCE DATA AND PRATICAL USER GUIDELINES When the active component in GAFChromic HD-V2 film is exposed to radiation, it reacts to form a blue colored polymer with absorption maxima at approximately 670 nm as shown in Figure 3. Note: The active component in HD-V2 is chemically the same as that in EBT3, EBT-XD and MD-V3, but the 3 crystalline form is different. Hence the absorbance maximum is about 670 nm rather than 635 nm.. 2.5 0Gy 50Gy 2 100Gy 1.5 250Gy 500Gy 1 0.5 0 400 450 500 550 Wavelength, nm 600 650 700 Figure 3: Spectra of GAFChromic HD-V2 as a function of adsorbed dose GAFChromic HD-V2 radiochromic dosimetry film may be measured with a transmission densitometer, a film scanners or a spectrophotometer. As can be inferred from the spectra in Figure 3, the response of the film is enhanced when measured with red light. For spectrophotometer measurements, the greatest response is obtained at peak absorbance wavelengths. Most densitometers measure over a band of wavelengths. Black/white densitometers measure over the entire visual band while color densitometers measure over various narrower red, green and blue bands within the visible spectrum. For two-dimensional measurement over a large film area the most efficient process is to use a 48-bit (16-bit per channel) flatbed color scanner. The EPSON Expression 11000XL Photo scanner, and the now discontinued model 10000XL Photo scanner are the recommended models. These are color scanners and measure the red, green and blue color components of light transmitted by the film at a color depth of 16 bit per channel. These EPSON scanners are particularly recommended due to their large scanning area. The typical dose response of HD-V2 film on an Epson color scanner is shown in Figure 4. We recommend to fit the calibration data to a function having the form d x (D) = a + b/(d-c), where d x (D) is the optical density of film in scanner channel x at dose D, and a, b, c are the equation parameters to be fitted. The advantages of this type of function are:

They are simple to invert and determine density as a function of dose, or dose as a function of density; They have rational behavior with respect to the physical reality that the density of the film increases with increasing exposure yet a p p r o a c h e s a near constant value at high exposures. Polynomial functions characteristically have no correspondence to physical reality outside the data range over which they are fitted; Since these functions have the described rational behavior, fewer calibration points are required saving time and film: A typical case would use 6-8 points (including unexposed film) with the doses in geometric progression. Figure 4: Response of GAFChromic HD-V2 in all Color Channels Detailed instructions defining the optimum procedure for scanning radiochromic film, establishing a calibration curve using FilmQAPro software and obtaining dose measurements from an application film are contained in the document Efficient Protocols for Calibration and Dosimetry Films on this web site. The procedures described have been thoroughly validated and are in widespread use in the medical physics community providing dose measurement uncertainty well below 2%. References 1. FilmQA Pro 3.0 software can be downloaded at www.filmqapro.com Micke, A., Lewis, D.F., Yu, X. Multichannel film dosimetry with non- uniformity correction, Med Phys, 38(5), 2523-2534 (2011).