Use of 3D Printers in Proton Therapy



Similar documents
Overview. Creation of 3D printed phantoms for clinical radiation therapy 7/7/2015. Eric Ehler, PhD Assistant Professor University of Minnesota

Feasibility Study of Neutron Dose for Real Time Image Guided. Proton Therapy: A Monte Carlo Study

Rapid prototyping. CAD / lecture. October 5, TO&I Vermelding onderdeel organisatie

World-first Proton Pencil Beam Scanning System with FDA Clearance

Therapy with protons and ion beams

How To Build A 3D Model From Scratch

BENEFITS OF 3D PRINTING VACUUM FORM MOLDS

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

Joint Application of Perl Scripts and MCNPX in Solving the Dynamic-Geometry Related Problems in Proton Beam Radiotherapy

GLOBAL MANUFACTURING. ARAUJO, Anna Carla AUG, 2015 Mechanical Engineering Department POLI/COPPE/UFRJ

Proton tracking for medical imaging and dosimetry

GAFCHROMIC DOSIMETRY MEDIA TYPE MD-V3

RAPID PROTOTYPING. Learning Objectives: By the end of the lecture the student should be able to: Explain the fundamentals of Rapid Prototyping

HITACHI Proton Beam Therapy System

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Monte Carlo Simulations in Proton Dosimetry with Geant4

Manufacturing Process and Cost Estimation through Process Detection by Applying Image Processing Technique

Tutorial: Rapid Prototyping Technologies

Scripps Proton Therapy Center: Configuration and Implementation

GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2

Dose Measurement in Mammography; What are we measuring? David E. Hintenlang, Ph.D. DABR University of Florida

Additive Manufacturing: Processes and Standard Terminology

How To Improve Your Ct Image Quality

Secondary Neutrons in Proton and Ion Therapy

Quality Assurance for Treatment Planning Systems

Facility Start Up, Training, and Operational Issues AT PTC H or Protons A Positive Marathon Inelastic Collision Experience

Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University

Correcting the Lateral Response Artifact in Radiochromic Film Images from Flatbed Scanners

How the uprint Rapidprotyping Machine Works

Testing the Suitability of Spatial Printing Technology for Engineering Applications (for Presentation of Topographic Surface)***

Status and perspective of emission imaging techniques for ion beam therapy in Lyon

Manual for simulation of EB processing. Software ModeRTL

Laue lens for Nuclear Medicine

Multi-Channel Radiochromic Film Dosimetry. Adapted from A.Micke Spain, April 2014

Rapid Prototyping. Training Objective

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

CONQUERING CANCER SAVING LIVES. Mayo Clinic Proton Beam Therapy Program

Marcus Fager Master of Science Thesis University of Pennsylvania, 11 June Supervisors:

New Advances in Rapid Prototyping using Inkjet-based 3D Printing

Evolution of Head and Neck Treatment Using Protons. Mayank Amin, M.Sc,CMD

DECISION SUPPORT SYSTEM IN RAPID PROTOTYPING TECHNOLOGY Arkadiusz Rzucidło, Grzegorz Budzik, Łukasz Przeszłowski

Overview of Proton Beam Cancer Therapy with Basic Economic Considerations

Fused Deposition Modeling: A Technology Evaluation

PCB Component Placement Inspection

The Prototyping Challenges with Micro Molding: A Comparative Study of Prototyping Methods for Micro Molding Applications

Current Status of Proton Clinical Activities at PTC H

PRECISION PROTOTYPING THE ROLE OF 3D PRINTED MOLDS IN THE INJECTION MOLDING INDUSTRY

Advanced Manufacturing Choices

DESIGN OF MANUFACTURING SYSTEMS BY RAPID PROTOTYPING TECHNOLOGY APPLICATION

An introduction to 3D draughting & solid modelling using AutoCAD

Cyclotron Centre in Poland and 2D thermoluminescence dosimetry

prepared by Gabe Landes for T. Purdy 2009

Brief Report on machines available in the 3D Printers market and their characteristics

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Chapter 5 POWDER-BASED RAPID PROTOTYPING SYSTEMS

Evaluation of a metal artifact reduction algorithm in CT studies used for proton radiotherapy treatment planning

Construction of human knee bone joint model using FDM based 3D Printer from CT scan images.

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

Radiotherapy in Hungary: present status and future needs. Tibor Major, PhD National Institute of Oncology Radiotherapy Department Budapest, Hungary

RapidArc QA Program in Prince of Wales Hospital. Michael L. M. Cheung, Physicist Prince of Wales Hospital Hong Kong

Production of Wind Tunnel Testing Models with use of Rapid Prototyping Methods

05, The third building which will be occupying 6,000 sq meters will be finished built soon, totaling to more than 16,000 sq meters..

Tim Smith - Sales Manager.

How To Treat Cancer With Proton Therapy

Variance reduction techniques used in BEAMnrc

The Science behind Proton Beam Therapy

5.3 Cell Phone Camera

Comparison of Epson scanner quality for radiochromic film evaluation

As published in PIM International

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

3D Printing & Medical Technology: New Risks & Potential for Liability Joe Coray, Vice President Corey LaFlamme, Assistant Vice President The Hartford

Additive manufacturing (aka 3D printing) of metallic materials Industrial applications and efficiency of technology

MLC Characteristics. Treatment Delivery Systems 2 Field Shaping; Design Characteristics and Dosimetry Issues. Presentation Outline

COURSE: ADVANCED MANUFACTURING PROCESSES. Module No. 5: OTHER PROCESSES

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Performance evaluation and quality assurance of Varian enhanced dynamic wedges

RHINO TO STL BEST PRACTICES

3D Printing Design Guidelines Sierra College CACT

In room Magnetic Resonance Imaging guided Radiotherapy (MRIgRT( MRIgRT) Jan Lagendijk and Bas Raaymakers

The feasibility of a QA program for ISIORT Trials

EXPERIMENTAL AND NUMERICAL ANALYSIS OF THE COLLAR PRODUCTION ON THE PIERCED FLAT SHEET METAL USING LASER FORMING PROCESS

Simulation of Proton Therapy Treatment Verification via PET imaging of Induced Positron-Emitters

Prototyping Process Choosing the best process for your project

Glossary. 3D Animation Using computer software to create and animate a three-dimensional representation of image data.

Key words: treatment planning, quality assurance, 3D treatment planning

HDR Brachytherapy 1: Overview of QA. Disclosures: Learning Objectives 7/23/2014

Ningbo Yinzhou Keao Prototyping & Mould Factory Services include : CNC machining prototypes,

4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.

Worldwide Quality Assurance networks for radiotherapy dosimetry

Film Scanner The term Film Scanner can refer to a dedicated slide and negative film scanner or to a capture type scanner.

Prospects of Laser Polishing for Small and Complexly Shaped Parts

TUTOR NOTES. How to use this pack. Rapid prototyping in schools. Definition

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

Zero Width Glass Cutting with CO 2 Laser

Holes & Selective Laser Sintering

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Use of lead shielding for adult chest CT. patient & radiographer experiences

Transcription:

Use of 3D Printers in Proton Therapy Nicholas Remmes, PhD Mayo Clinic, Rochester, MN Department of Radiation Oncology Remmes.Nicholas@mayo.edu 2015 MFMER slide-1 Disclosures/Confessions My 3D Printing Process Stephen Corner Mayo Engineer 3D printing guru =? 2015 MFMER slide-2 1

Disclosures Limited Printer Experience Printer 3D Build Process Dimension Elite* Fused Deposition Modeling (Plastic Extrusion) Fortus 400 mc* Fused Deposition Modeling (Plastic Extrusion) Objet Connex 350* PolyJet (Liquid Printing, UV Curing) Material ABS Polycarbonate Liquid acrylic photopolymer Layer 0.178 mm 0.178 mm 0.016 mm Thickness Nozzle Size 0.254 mm 0.178 mm NA 2015 MFMER slide-3 3D Printer Use in Proton Therapy Beam Filters Not generally patient specific Nozzle-based Used almost exclusively in scanning beam systems Compensators Patient and beam specific Nozzle-based Used almost exclusively in double scatter systems Design is created in the treatment planning system 2015 MFMER slide-4 2

Scanning Beam Problem Narrow Low Energy Bragg Peaks Narrow Bragg peak equires more energy layers to construct a spread-out Bragg peak and longer treatment times Due to reduced volume covered by spot, treatment plans can suffer from minimum MU delivery limitations (low MU spots are eliminated). * L. Courneyea, C. Beltran, H.S. Wan Chan Tseung, J. Yu, M.G. Herman. Optimizing mini-ridge filter thickness to reduce proton treatment times in a spot-scanning synchrotron system. Med Phys. 41, 061713 (2014) 2015 MFMER slide-5 Pyramid Filter Design Prototype 0.6 mm 25 mm 5 mm 2.5 mm Low Z to minimize scatter (and resulting increase in spot size) Step height fixed by 3D printer layer thickness Step width tuned to give Gaussian depth profile critical for robust planning Seemingly perfect application of 3D printing 2015 MFMER slide-6 3

Visual Inspection A Note: Filter A used an earlier sandwich design. C B 2015 MFMER slide-7 Inspection with CT Imaging B C 2015 MFMER slide-8 4

Inspection with Micro CT Imaging B C 2015 MFMER slide-9 Reality Check: QA for Full Size Filter MicroCT is clearly not a practical go-to tool for QA QA should focus on functionality of device for intended purpose To the extent possible, QA should utilize tools already available. 2015 MFMER slide-10 5

Depth Dose Curve Monte Carlo simulation vs Measurement is appropriate for a beam filtering device that will be incorporated into beam data Depth Dose 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 Measured (71.3 MeV) 0.1 Simulated (71.3 MeV) Unfiltered (71.3 MeV) 0 25 30 35 40 45 50 Depth (mm) Depth Dose 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 Measured (71.3 MeV) Simulated (71.3 MeV) Unfiltered (71.3 MeV) 0 0 10 20 30 40 50 Depth (mm) Perl J, Shin J, Schumann J, Faddegon B, Paganetti H, TOPAS: an innovative proton Monte Carlo platform for research and clinical applications. Med Phys. 39(11) Nov 2012 2015 MFMER slide-11 Proton Radiograph Image with radiochromic film at distal edge of proton range Filter is in direct contact with film Markus chamber for tuning acrylic thickness prior to imaging. Uniform proton beam field Acrylic with thickness tuned to the distal R50 at the film Filter with film immediately behind it. Quick and easy to setup (<1hr) using equipment readily available in most proton centers 2015 MFMER slide-12 6

37 mm of acrylic 2015 MFMER slide-13 34 mm of acrylic: note variation that causes Moiré Pattern Pattern changes when acrylic is rotated. 1mm sheets of acrylic have thickness variation of about 10%. A very precise method of testing our acrylic slabs! 2015 MFMER slide-14 7

35 mm of acrylic (no 1mm slices of acrylic) 2015 MFMER slide-15 3D Compensators IJROBP, 88:2, pp 453-458, 2014 2015 MFMER slide-16 8

Comments on work by Sang Gyu Ju et al. Milled compensators vs 3D printed compensators (ultraviolet curable acrylic plastic) Measured surface dimensions with 3D scanning technique Imaged with CT scanner Measured central axis PDD Measured selected dose planes Results indicate very good agreement between both compensators and TPS doses. Sang Gyu Ju et al., IJROBP, 88:2, pp 453-458, 2014 2015 MFMER slide-17 Comments on work by Zou et al. Fused Deposition Modeling (FDM) vs Selective Laser Sintering (SLS) Checked dimensions with calipers Imaged with CT scanner Measured depth dose curves with a Bragg peak chamber Measured dose distributions in an anthropomorphic phantom Zou et al, JACMP, 16:3, p 90-98, 2015 2015 MFMER slide-18 9

Warnings about FDM printing: From Zou et al: due to the random slight inhomogeneity in the FDM printing, the properties of the printed object should be understood before being applied to proton therapy. Note how proton therapy is singled out! Zou et al, JACMP, 16:3, p 90-98, 2015 2015 MFMER slide-19 A quick experiment Two solid 5cm x 5cm x 1cm blocks printed on two different FDM printers with two different materials (ABS and polycarbonate) Measure central depth dose, CT, and radiograph Both blocks pass visual inspection and dimension measurements. 2015 MFMER slide-20 10

Depth Dose 1 0.9 0.8 0.7 1 0.9 0.8 0.7 open (shifted) Printer B 1cm Acrylic (shifted) Depth Dose 0.6 0.5 0.4 Depth Dose 0.6 0.5 0.4 0.3 open (shifted) 0.3 0.2 Printer A 0.1 1cm Acrylic (shifted) 0 25 27 29 31 33 35 Depth (mm) 0.2 0.1 0 20 22 24 26 28 30 Depth (mm) Open field depth dose is shifted for purpose of comparison Some discrete jumps due to MLIC electronics 2015 MFMER slide-21 Printer A Printer B 2015 MFMER slide-22 11

Proton Radiographs Printer A Printer B with acrylic rotated 45 degrees between images 2015 MFMER slide-23 Conclusions 3D printing has been shown to be a useful tool in proton therapy. Quality assurance is key: expect imperfections unless demonstrated otherwise Surface measurements are not very useful for quality assurance Dose measurements in the middle of the SOBP are probably not sufficient QA either. CT scans of each device should be considered at a minimum. Proton radiographs and depth dose measurements are also recommended. 2015 MFMER slide-24 12

Acknowledgements Stephen Corner Lorraine Courneyea Bradley Kemp Chris Beltran Jon Kruse Josh Stoker Michael Herman 2015 MFMER slide-25 13