TECHNICAL INFORMATION Bulletin



Similar documents
CENTRIFUGAL PUMP OVERVIEW Presented by Matt Prosoli Of Pumps Plus Inc.

FAIRBANKS NIJHUIS FIRE PUMPS.

Fire Pump Plan Review March 2010

Centrifugal Fans and Pumps are sized to meet the maximum

Pumps: Convert mechanical energy (often developed from electrical source) into hydraulic energy (position, pressure and kinetic energy).

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

300 Series PA Pump and Cooler Assemblies

Model 362A AURORA. 340A/360A Series SINGLE STAGE END SUCTION PUMPS.

BSM MOTOR DRIVEN CENTRIFUGAL PUMPS

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators

MEMBRANE VACUUM MINI PUMPS

Fig 1 Power Transmission system of Tractor

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

TECHNICAL ADVISORY BULLETIN

TECHNICAL INFORMATION Bulletin

Pumps SELECTION OF A PUMP

SJT / SJM / SJP Large Vertical Pumps

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Horizontal Jet Pumps 1/3-1-1/2 HP

FREQUENCY CONTROLLED AC MOTOR DRIVE

Axial and Mixed Flow Pumps for Large Volume Pumping

TECHNICAL INFORMATION Bulletin

Unit 24: Applications of Pneumatics and Hydraulics

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

ENERGY TRANSFER SYSTEMS AND THEIR DYNAMIC ANALYSIS

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

VERTICAL TURBINE AND PROPELLER PUMPS

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Equipment: Power Supply, DAI, Wound rotor induction motor (8231), Electrodynamometer (8960), timing belt.

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Example. Fluid Power. Circuits

ENGINE COOLING SYSTEM

Unit 24: Applications of Pneumatics and Hydraulics

The Secret of Hydraulic Schematics. BTPHydraulics

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Basic Nameplate Information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Rexroth Hydraulic Pump A10VO Series User Manual

Pump Maintenance - Repair

Vertical Pumps for the Oil & Gas Industry

Automatic Transmission Basics

Understanding the Alternator

KINETIC ENERGY RECOVERY SYSTEM BY MEANS OF FLYWHEEL ENERGY STORAGE

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Direct Current Motors

BUT PRECAUTIONS MUST BE TAKEN OR SERIOUS BURNS CAN RESULT.

An SPX Process Equipment Operation. Universal II Industrial Series Rotary Positive Displacement ECP Pumps

Rules for Classification and Construction Additional Rules and Guidelines

Why and How we Use Capacity Control

AC Electric Motors best practice

MINEX -S. Magnetic coupling. You will find continuously updated data in our online catalogue at

Principles of Adjustable Frequency Drives

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

Table of Contents. Transmission Fundamentals

APPENDIX F VIBRATION TESTING PROCEDURE

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

Pump Selection and Sizing (ENGINEERING DESIGN GUIDELINE)

DIRECT CURRENT GENERATORS

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Tiguan Haldex All-Wheel Drive

NFPA31FuelOilPiping 1 Revised

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Unit 24: Applications of Pneumatics and Hydraulics

SPP Pumps Inc. Atlanta

Pressure Limiting Driver (PLD)

HCS Teknik Bobinaj Soğutma Kompresörleri Bakım, Onarım, Revizyon - How Cooling System Operates?

OUR PRODUCTS TRH-TRS-TRM-TRV. LIQUID RING VACUUM PUMPS AND COMPRESSORS Capacity up to 2100 ACFM Vacuum to 29 Hg. Our Other Products.

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

ABB drives. Technical guide No. 4 Guide to variable speed drives

How To Clean Up A Reactor Water Cleanup

Controlled Start transmission

FUNDAMENTALS OF GAS TURBINE METERS John Gorham Sensus Metering Systems 805 Liberty Blvd. DuBois, PA 15801

HORIZONTAL PUMPING SYSTEM

A BRIEF INTRODUCTION TO CENTRIFUGAL PUMPS

Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

Pressure Relief and Regulating Valves

AC Induction Motor Slip What It Is And How To Minimize It

TOPIC: KNOWLEDGE: K1.01 [3.3/3.5] Which one of the following contains indications of cavitation in an operating centrifugal pump?

Product Brochure. Controlled start transmission

Electric Coolant Pumps. Always at the Correct Temperature

INTERNATIONAL FIRE TRAINING CENTRE FIREFIGHTER INITIAL PUMPS AND PRIMERS. Throughout this note he means he/she and his means his/hers.

Hydraulic Pump/Motor Division Hydraulic Pump/Motor Division

The Auto-tensioner Market and Technical Trends

Motors and Inverters for Environmentally Friendly Industrial Equipment

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

Hydraulic Trouble Shooting

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

Michelin North America

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

Pump Skid Fabrication for Magnetic Coupling. Rick Soltis Chief Mechanic City of Bedford

Rotary Phase Converters

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Chapter 3.5: Fans and Blowers

Transcription:

Peerless Pump Company 2005 Dr. M.L. King Jr. Street, P.O. Box 7026, Indianapolis, IN 46207-7026, USA Telephone: (317) 925-9661 Fax: (317) 924-7338 www.peerlesspump.com www.epumpdoctor.com TECHNICAL INFORMATION Bulletin PEERLESS PUMP HYDROCONSTANT VARIABLE SPEED FLUID DRIVES NUMBER 102 INTRODUCTION Hydroconstant fluid drive system is the name given by Peerless Pump to a pumping system which consists of an electric motor, stepless variable speed drive, centrifugal pump, and appropriate control apparatus. The system provides constant pressure through smooth speed variation, to a variable capacity demand application. The Hydroconstant fluid drive system is tankless since, unlike a hydro-pneumatic tank. There are several manufacturers of tankless systems; almost as many as there are types of stepless variable speed drives and pressure reducing mechanisms. However, there are only two general types of tankless systems; variable speed type, and pressure reducing valve type. Stepless variable speed drives can be bought from many manufacturers in every conceivable engineering principle. For example, mechanical variable speed devices can take the form of friction cones, variable pitch pulleys and planetary gears. Mechanical power transmission devices have an efficiency of about 90% and have generally increasing torques as the output speed decreases. Electric motors are widely used as infinitely variable speed machines. Direct current (DC) motors are excellent variable speed drives; many makes of Alternating current (AC) motors use various ingenious means of speed variation. In general, AC variable speed control follows these broad categories: wound rotor motor, SCR (Silicon-controlled rectifier), and variable frequency control. Another common form of electrical variable speed drive is the magnetic field or eddy current coupling. Variable speed drives in the hydraulic field are made up of fluid couplings which operate through the medium of oil, water, or silicone compounds. Hydro-kinetic fluid couplings operate on the kinetic energy transfer principle while the silicone fluid coupling operates on the principle of shear. Hydro-kinetic couplings are applied to drives with ratings up to thousands of horsepower and generally use oil as the energy transfer fluid. The silicone fluid coupling is predominantly a lower power (5 HP at present) coupling primarily used in the automotive field as a fan drive for radiator cooling. The data that follows provides general characteristics of the most commonly used variable speed single pump and multiple pump combinations presently used in constant pressure pump applications using the Peerless Pump Hydroconstant fluid drive. 1 Revised 07/06

PEERLESS PUMP HYDROCONSTANT VARIABLE SPEED FLUID DRIVE The Hydroconstant fluid drive (Figure 1) has been used extensively in variable speed pump service applications. The fluid drive-coupling belongs to the general class of hydraulic power transmitting machinery known as hydrokinetic drives. The machines in this class depend for their operation on the utilization of the kinetic energy contained in a moving mass of liquid. Basically a fluid drive-coupling consists of two hollow rotating members: an impeller (pump) which transforms the rotational energy supplied by a driver into kinetic energy contained in a moving mass of liquid, and a runner (turbine) which converts the kinetic energy back to rotational energy (Figure 2). Output torque, and speed range from zero to maximum RPM can be achieved by controlling the amount of oil in the rotating members of the fluid drive-coupling. The oil volume inside the rotating members is controlled by a movable splitter which, depending on system pressure demand, directs an amount of oil into the rotating members. An oil jet, (150 SSU at 100 F. oil) is fed to the movable splitter by a constant oil feed pump located inside the Hydroconstant fluid coupling housing. The oil feed pump is chain driven at a constant speed by the Hydroconstant drive input shaft. The housing forms a sump for the feed-oil. HI-NEMA Close- Coupled Electric Motor Pressure Gauge Pressure/Output Speed Control Pressure/Output Speed Control Adjusting Knob Temperature Control Valve Water/Oil Heat Exchanger Peerless Pump Series C Close Coupled Centrifugal Pump FIGURE 1 Type MP Size 6B or 8B Hydroconstant Variable Speed Fluid Drive 2 Revised 07/06

Pressure Control Fluid Coupling Oil Flow Splitter Input Shaft Output Shaft Oil Pump Oil Sump Heat Exchanger FIGURE 2. Oil Circuit The splitter is connected to an arm located inside the Hydroconstant fluid Drive housing. By moving this arm, the splitter is move into or out of the path of the oil jet. If all of the oil jet flow is directed into the rotating members, the output shaft rotates continuously at full speed. Oil from the rotating members is constantly being discharged to the sump at an equilibrium capacity through orifices located on the periphery of a rotating member. Therefore, constant pressure equilibrium in a hydraulic system is maintained by oil supply to the rotating members being equal to the oil discharge through the orifices. The volume of oil inside the rotating members seeks a value which maintains an equilibrium of input-todischarge oil related to the requirements of the hydraulic system pressure and, thus indirectly related to output shaft RPM. (Pump head changes as the square of RPM) Hydroconstant fluid drive output torque is always equal to input torque. Operating output speed is always lower than the input speed. The intelligence that controls the equilibrium of Hydroconstant fluid drive oil flow and hydraulic system pressure is performed by a change of oil mass pressure. Pressure from the hydraulic system to be controlled is piped to a spring loaded piston in the hydraulic pressure control. When the pressure in the hydraulic system increases, the piston moves forward, re-establishing the equilibrium between the spring force and the piston force. The piston is connected to the arm of the splitter. From this description it is apparent how the pressure control functions. Used with the Hydroconstant fluid drive and a pump the assembly becomes part of Peerless Pump Hydroconstant pumping system. RPM = HP x C TORQUE 3 Revised 07/06

For example, if the pump is at zero RPM and the system pressure change requires full pump RPM to satisfy the pressure setting, the time required for this speed change is about 15 seconds. The deceleration time from full RPM to zero RPM is about 20 seconds. However, for small increment speed changes the time lapse is negligible (Figures 4 and 5). The acceleration and deceleration rate of the Hydroconstant drive limits the maximum demand flow change that the Hydroconstant fluid drive system is capable of satisfying while maintaining a constant system pressure. Figure 4 Figure 5 4 Revised 07/06

The two graphs (Figures 6 and 7) show the approximate "maximum demand change" of which a Hydroconstant drive pumping system is capable, while maintaining constant pressure during acceleration and deceleration. Note: It requires about one-third of a minute to satisfy the maximum design capacity starting from zero RPM, or to reduce from maximum RPM to zero RPM (while keeping system pressure constant). The flow is changing directly as the RPM of the pump. Figure 6 Figure 7 5 Revised 07/06

It is important that in the application of a Hydroconstant fluid drive consideration be given to the expected flow rate changes in the system and the capabilities of the drive as indicated by these curves (Figures 4 through 7). The head capacity characteristics of the pump should be chosen to complement the system demand requirements and the response speed of the Hydroconstant fluid drive. Refer to section on pump selection. COMPONENTS OF HYDROCONSTANT FLUID DRIVE 1. Cast Iron Housing. 2. Aluminum fluid drive rotating element. 3. Oil lubricated bearings. 4. Internal oil circulating pump. 5. Non-corrosive control parts. 6. Oil level sight glass. 7. Integrated pressure control assembly which includes: a. Automatic spring-loaded piston and diaphragm for sensing pneumatic or hydraulic (water) signals. b. Manually adjustable pressure control. c. Discharge pressure gauge. 8. When required: a. Heat exchanger 125 psi maximum working pressure. b. Automatic cooling water temperature control valve with Monel seals and stainless steel spring set. c. Brass cooling water strainer. Type MP Closed Coupled Motor and Series C Close Coupled Pump Type M Closed Coupled Motor and Output Shaft for FlexibleCoupled Pump Type MX Flexible Coupled Motor and Close Coupled Series C Pump Type MO Flexible Coupled Motor and Output Shaft for FlexibleCoupled Pump 6 Revised 07/06

NOMINAL RPM HYDROCONSTANT FLUID DRIVE OPERATING DATA 60 HERTZ TYPE FLUID COUPLING SIZE BHP IN % SLIP CIRCULATION % EFFICIENCY BHP OUT RPM OUT FULL 115% FULL 115% LOSS HP FULL 115% FULL 115% FULL 115% LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD 1750 M,MP,MO,MX 8C 3.00 3.45 5.00 5.50 0.45 80.0 81.2 2.4 2.8 1640 1615 1750 M,MP,MO,MX 8C 5.00 5.75 6.70 7.60 0.45 84.0 85.2 4.2 4.9 1610 1580 1750 M,MP,MO,MX 8C 7.50 8.62 9.30 11.00 0.45 85.3 84.7 6.4 7.3 1565 1520 1750 M,MP,MO,MX 9B 7.50 8.62 4.20 4.65 0.50 89.1 89.5 6.7 7.7 1675 1665 1750 M,MP,MO,MX 9B 10.00 11.50 5.10 5.60 0.50 89.9 90.1 9.0 10.4 1650 1640 3500 M,MP,MO,MX 6A 3.00 3.45 3.00 4.10 0.55 76.7 81.2 2.3 2.8 3320 3285 3500 M,MP,MO,MX 6A 5.00 5.75 5.00 5.50 0.55 84.0 85.2 4.2 4.9 3275 3235 3500 M,MP,MO,MX 8C 7.50 8.62 2.20 2.50 0.70 88.0 89.3 6.6 7.7 3375 3340 3500 M,MP,MO,MX 8C 10.00 11.50 2.80 3.10 0.70 90.0 91.3 9.0 10.5 3355 3320 3500 M,MP,MO,MX 8C 15.00 17.25 3.80 4.20 0.75 91.3 91.6 13.7 15.8 3320 3280 3500 MO,MX 8C 20.00-4.60-0.90 91.0-18.2-3340 - 3500 MO,MX 8C - 23.00-5.10 1.10-90.4-20.8-3300 3500 MO,MX 8C 25.00-5.20-1.35 89.6-22.4-3320 - 3500 MO,MX 8C - 28.75-5.80 2.25-83.5-24.0-3275 1750 M,MP,MO,MX 9B 7.50 8.62 4.20 4.65 0.50 89.1 89.5 6.7 7.7 1675 1665 1750 M,MP,MO,MX 9B 10.00 11.50 5.10 5.60 0.50 89.9 90.1 9.0 10.4 1650 1640 1750 M,MP,MO,MX 11B 10.00 11.50 1.86 2.10 0.75 90.8 91.5 9.1 10.5 1708 1700 1750 M,MP,MO,MX 9B 15.00 17.25 6.65 7.30 0.50 90.0 89.8 13.5 15.5 1630 1620 1750 M,MP,MO,MX 11B 15.00 17.25 2.45 2.65 0.75 92.6 93.0 13.0 16.0 1705 1700 1750 M,MP,MO,MX 11B 20.00 23.00 2.90 3.10 0.75 93.2 93.6 18.6 21.5 1700 1695 1750 M,MP,MO,MX 11B 25.00 28.75 3.20 3.50 0.75 93.8 93.9 23.5 27.0 1690 1685 1750 M,MP,MO,MX 11B 30.00 34.50 3.60 3.95 0.75 93.4 93.9 28.0 32.4 1685 1680 1750 M,MP,MO,MX 11B 40.00 46.00 4.40 5.00 0.75 93.7 93.4 37.5 43.0 1670 1660 1750 M,MP,MO,MX 11B 50.00 57.50 5.45 6.40 0.75 93.1 92.3 46.8 53.1 1655 1635 3500 M,MP,MO,MX 9B 15.00 17.25 1.90 2.05 1.60 87.4 88.7 13.1 15.3 3430 3425 3500 M,MP,MO,MX 9B 20.00 23.00 2.25 2.40 1.60 89.8 90.6 18.0 20.8 3420 3415 3500 M,MP,MO,MX 9B 25.00 28.75 2.55 2.75 1.60 91.1 91.7 22.8 26.4 3410 3400 3500 M,MP,MO,MX 9B 30.00 34.50 2.80 3.00 1.60 91.9 92.4 27.6 31.9 3400 3395 3500 M,MP,MO,MX 9B 40.00 46.00 3.30 3.55 1.60 92.7 93.0 37.1 42.8 3385 3375 3500 M,MP,MO,MX 9B 50.00 57.50 3.60 4.00 1.60 93.2 93.2 46.6 53.6 3375 3360 3500 MO 9B 60.00 69.00 4.10 4.45 1.60 93.2 93.2 55.9 64.3 3355 3345 3500 MO 9B 75.00 86.25 4.70 5.15 1.60 93.2 93.0 69.9 80.2 3335 3320 3500 MO 9B 100.00 115.00 5.70 6.40 1.60 92.7 92.2 92.7 106.0 3300 3275 7 Revised 07/06

DESCRIPTION OF PUMPING SYSTEMS SINGLE PUMP SYSTEM A single pump system consists of one variable speed pump sized to satisfy 100% of the system demand. The pressure control will vary the pump speed to satisfy system demand. A standard motor starter is the only electrical control a single pump Hydroconstant system needs. There are applications where it is desirable that the Hydroconstant system have other auxiliary controls. For example, a city ordinance may not allow a pump on stream if the water main pressure is less than a specified value. This is taken care of by the addition of the optional automatic low suction pressure cut-off control. There are any number of such optional controls that Peerless Pump will design to meet specific customer needs. All optional controls are actuated through 115 volt control circuits. Single pump Hydroconstant systems are often applied in pairs; only one unit operates at a time while the other unit is used as a standby. Transfer of the units from standby duty to operational duty is done either manually or automatically. The pumps are sized so that each satisfies 100% of the system demand. Pumps used on single pump Hydroconstant systems are sized for maximum GPM demand of a given application. Therefore, where the demand is very small for prolonged periods of time, it' may be desirable that a single pump system use a small constant speed pump as an auxiliary supply pump. This small pump is usually called a pressure maintenance pump and is sized to satisfy about 10-20 GPM demand without the variable speed pump on stream. Of course, when the required system demand exceeds the pressure maintaining capabilities of the jockey pump the Hydroconstant drive pumping unit will automatically come on stream. At this point it is optional whether the pressure maintenance pump is kept on stream or taken off. MULTIPLE PUMP SYSTEMS: Two-Pump, Variable Speed, Additive A two pump additive system consists of two single pump variable speed units on stream so one unit complements the capacity of the other as the system demand exceeds the capabilities of lead pump. Each pump is sized to satisfy about 55% of the maximum system demand. Therefore, when the system demand is 55% or less of maximum the lead pump is on stream. When the system demand increases above 55% of maximum the second or additive pump is automatically put on stream and the lead pump is "locked-in" at full speed. Two-Pump; One Constant Speed; One Variable Speed Additive A two-pump additive system consists of one constant speed pump and one variable speed pump, each sized to satisfy about 55% of the system demand. The two units operate as an additive system with the variable speed pump always in the lead. The constant speed pump is automatically added on stream when the system demand exceeds 55% of maximum demand; the variable speed pump will speed-up or slow down in order to keep the system pressure constant. When the system demand decreases below 55 of maximum demand the constant speed pump is taken off stream and the variable speed pump will keep the system pressure constant. Pressure Maintenance Pump Either the variable speed or constant speed/variable speed two-pump additive systems can be used with a pressure maintenance pump. This pump is sized to satisfy about 10-20 GPM demand can be coordinated with the other two pumps to meet the system requirements. 8 Revised 07/06

PUMP SELECTION Selection of the correct pump to be used in a Hydroconstant fluid drive unit is one of the most important factors in obtaining proper operation of the system. It is not enough to merely select a pump which will produce the specified head at the rated capacity. Careful consideration must be given to the overall head-capacity performance characteristics of the pump for each individual application. At the time of pump selection give consideration to the expected maximum demand changes and the speed of response by the Hydroconstant fluid drive coupling as described previously. The Hydroconstant fluid drive coupling is capable of meeting a total demand change of design GPM per second: 5 x (Maximum RPM) (%) (Max. RPM) - (Min. RPM) There are three general head-capacity characteristics to be considered when applying horizontal centrifugal pumps to variable speed, constant pressure systems. (The characteristics describe the fixed speed performance graph as the capacity is decreasing): Constantly rising Flat Drooping Constantly Rising Head-Capacity Characteristics A typical performance curve for a pump with a constantly rising head-capacity characteristic is shown in Figure 9. When applied to a variable speed drive to produce a constant discharge pressure, the speed-capacity curve is essentially a mirror image of the head-capacity curve, (assuming constant suction pressure). When a pump is expected to operate from shut-off to design capacity, and when the splitter arm position is used as the triggering mechanism for other control equipment, a pump with a constantly rising characteristic is advantageous. FIGURE 9. Constantly Rising Head-Capacity 9 Revised 07/06

Flat Head-Capacity Characteristics A typical performance curve for a pump with a flat head-capacity characteristic is shown in Figure 10. This performance does not need much alteration by speed variation, unless the suction pressure changes widely. Again, the speedcapacity curve is a mirror image of the headcapacity curve, (assuming constant suction pressure). This pump characteristic offers practically no change in speed from shut-off to design capacity, and it becomes impractical to use splitter arm position as a triggering device for other controls. A pump with this characteristic curve can be very successfully applied to a system where large and frequent changes in capacity and suction pressure are expected. FIGURE 11. Drooping Head Capacity This undesirable feature can be overcome, however, by the addition of a small pressure maintenance pump, which itself can have variable speed, such as utilizing a Hydroconstant fluid drive size 6 or 8. This pump will increase the pressure near shut-off if properly selected and will force the main variable speed pump to slow down so that the minimum speed does occur at the shut-off. See Figure 12 which shows the effect of adding a jockey pump. FIGURE 10. Flat Head-Capacity Drooping Head-Capacity Characteristics A typical performance curve for a pump with a drooping head-capacity characteristic is shown in Figure 11. An appreciable speed change may occur from design capacity to minimum speed; however, the minimum speed does not occur at shut-off. From the minimum speed point to shutoff, the pump must actually increase speed to maintain constant pressure. Where control functions must be performed with splitter arm position as the triggering mechanism, a pump with this characteristic is not desirable. FIGURE 12. Effect of Adding a Pressure Maintenance Pump 10 Revised 07/06