NI-ZN BATTERY SPECIFICATION



Similar documents
EVERGREEN (C.P.) USA INC. TEL: (650) FAX: (650) SPECIFICATIONS Lithium Battery CR123A- 1700mAh

Specification. Li-ion Rechargeable Battery

Approval Sheet for. Li-ion Battery (Lithium Iron Phosphate) Model: LiR14505F-600mAh

LI-POLYMER BATTERY PACKS. Specification. Type: mAh. Prepared/Date Auditing/Date Approved/Date WANG MAR 16, 2006 LI MAR 16, 2006

Li-Polymer Battery Technology Specification

Lithium Ion Battery Specifications

Product Specification

LITHIUM BATTERY CR123A SPECIFICATION

PRODUCT SPECIFICATION

Li-ion Rechargeable Battery. Specification

Spec. No. ICR C Version No. 0.0

Title Li-ion Battery Specifications (Steel) Page 1/11

1. Scope This specification is applied to ICR Product Specification Table 1 No. Item Rated Performance Remark

Product Specification

li-ion Polymer Battery Specification

Specification Approval Sheet

Product Specification

Lithium-ion Battery Specification

Superior Lithium Polymer Battery

Product Specification

Li-ion Polymer Battery Specification

Lithium-Polymer Battery

Lithium-Ion Battery SPECIFICATION

S P E C I F I C A T I O N F O R L I T H I U M B A T T E R Y. M o d e l : C R

DELIVERY SPECIFICATIONS

Product Title Abstract

User s Manual Before using the inverter, you need to read and save the safety instructions.

Primary lithium battery LST 14250

A23 TECHNICAL SPECIFICATION FOR ALKALINE MANGANESE DIOXIDE BATTERY DATE : 21/8/2003

Dear Neuton Owner, This is a helpful hint to guide you in getting the most out of your NEUTON Battery and Charger.

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

BAO TONG USA dba TYSONIC BATTERY. SPECIFICATION SHEET FOR 9V NI-MH RECHARGEABLE BATTERY TY-9V-200mAH

Infrarot-Bewegungsmelder IP44

12 Volt 30 Amp Digital Solar Charge Controller

A Guide to the Safe Use of Secondary Lithium Ion Batteries in Notebook-type Personal Computers

SHENZHEN PKCELL BATTERY CO., LTD. Li-Polymer Battery Technology Specification

Achat 115MA full-range speaker. user manual

TRANSPORT OF DANGEROUS GOODS

If you accidentally get battery acid on your skin, flush it with lots of water

TELEDYNE BATTERY PRODUCTS. INSTRUCTIONS FOR CONTINUED AIRWORTHINESS and COMPONENT MAINTENANCE MANUAL. For

UN Manual of Tests and Criteria, Sub-section 38.3, Amendments to the 5 th edition, effective 2014 January 1 st

Alkaline Manganese Dioxide Battery Product Safety, Transportation and Disposal

Height w/o Terminals (in)

Safety data sheet for product

PRODUCT SAFETY DATA SHEET

3 WATT LED SPOTLIGHT Model No. SLM

NFC Communication Tray Model: HHX-IT3-Z

Carefree Sealed Lead Acid (SLA) MSDS

OWNER S MANUAL. Model AE150/AE300/AE AMP MULTI-USE SMART BATTERY CHARGER READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

12. Inspection and Maintenance

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

Jarv Joggerz BT-301 Bluetooth Stereo Headphones Users Guide

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

Power chip resistor size 2512 PRC221 5%; 2% FEATURES Reduced size of final equipment Low assembly costs Higher component and equipment reliability.

ADM1TE 5/30A DIN rail single phase two wire energy meter

BC-5000 OPERATIONS MANUAL BATTERY CAPACITY TESTER COFKO LLC.

Model UT201/202: OPERATING MANUAL. Table of Contents

How To Use A Power Supply Unit (Upu)

Height w/o Terminals (in)

EPSOLAR LS0512R / LS0524R. Solar Light Controller INSTRUCTION MANUAL. Please read this manual carefully before using the product!

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

Handbook. We aim to bequeath a beautiful Earth for our future generations.

Instructions: Part I. Charge the Power Bank. Method 1. Charge the Power Bank via Computer USB Terminal.

Automatik-Lader AL 600 Automatic Charger AL 600 fcr V / for V. Best.-Nr. : / Order No

User s Manual AURORA 1.2K/2.2K

INSTALLATION AND OPERATION MANUAL. Batteries for electric drive of bikes EVBAT48V9A-R EVBAT36V13A-R

Solar Controller / Battery Charger User s Manual

Guidance for upgrading to GB (IEC : 2005, MOD)

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

International English

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Material Safety Data Sheet

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Circuit Breakers. NRC Series. NRC Series

High-ohmic/high-voltage resistors

INSTRUCTION MANUAL PLEASE READ ALL THE INSTRUCTIONS COMPLETELY BEFORE USE AND SAVE THIS MANUAL FOR FUTURE REFERENCE

Environment-Laboratory Ambient Conditions

MULTI XS 4003 Battery charger

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

UT202A Operating Manual. Contents

Kolorlux. GE Lighting DATA SHEET

PART 1 - INTRODUCTION...

2013 VTech Printed in China US

Thyristor-controlled power supplies and battery chargers

Battery Cell Balancing: What to Balance and How

Table Of Contents

Additional information: -OSHA Instruction CPL 2.103, Field Inspection Reference Manual, Chapter IV, Section A -29 CFR 1910, Subpart I, Appendix B

LITHIUM BALANCE CHARGER

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Outer Diameter 23 φ mm Face side Dimension 20.1 φ mm. Baffle Opening. Normal 0.5 Watts Maximum 1.0 Watts Sine Wave.

Odyssey of the Mind Technology Fair. Simple Electronics

PSACH v.1.0 PSACH 24VAC/6A/1x6A HERMETIC AC power supply for CCTV

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

The following document contains information on Cypress products.

Battery Power Inverters

Day / Night IR Color Camera User Manual V2.1.0

Transcription:

NI-ZN BATTERY SPECIFICATION 252000 Model Name: AA2500mWh(Ni-Zn) Issued Date: Sept. 2010

NICKEL ZINC BATTERY SPECIFICATION 1.APPLICATION The applicable range: This specification is available only for the testing within one month since receipt of batteries. It s not a standard for stored goods. Model: 2500mWh(NI-ZN) 2.RATINGS Nominal Voltage Nominal Minimum Standard charge rate Rapid charge rate 1.6 V 1500mAh /300mA 1375 mah/300ma Constant current charge 300 minutes to 1.9 V at 300mA; Constant voltage charge 90 minutes at 1.9V to 50mA current. Constant current charge 120 minutes to 1.9 V at 750mA; Constant voltage charge 90 minutes at 1.9V to 50mA current. Discharge Terminal Voltage Discharge terminal voltage to 1.3V at below 750 ma; Discharge terminal voltage to 1.2V at 750mA to 1500mA current. Operating temperature range Humidity: +65%± 20% Standard charge 0 to +45 Rapid charge 10 to +45 Floating charge -10 to +45 Discharge -20 to +65 Storage temperature range Humidity: +65%±20% Within 1 year -20 to +35 Within 6 months -20 to +45 Within 1 month -20 to +55 Within 1 week -20 to +65 Note : (1)All rapid charge methods should be discussed with our engineers. (2)We stipulate to charge below 30% fully power for delivery considering risk, if customer requires charged power to exceed what we stipulated, then happen risky problem because of charge, BetterPower won t be responsible for this during delivery and storage. (3)Warranty time : 6 months. (4) It requires with 30% charge for storage when batch batteries in stock, we suggest charge battery once every 3 months if battery had been stocked over 3 months. (5)The outer case of battery, after tin-plated processing, the place is a little soft, coating brightness is not high, the color is non-uniform. The naked eye seems likely the outward appearance bad or the shell body sully, which is really normal, and the determination standard should be taken the bilateral consultation as a standard.

(6)The outer case of battery, after tin-plated processing, the place is a little soft. For example, in the battery use process, it is normal that the battery shell base presents the scratch. The determination standard should be taken the bilateral consultation as a standard. 3.Measurement & Dimensions to see the drawing: D1 D H 14.5-0.7 mm 51.0-1.0 mm H H1 D 4. TEST 4.1 Test conditions: 4.1.1 The battery to be tested is the product within one month after being received by customer. 4.1.2 Ambient conditions: Temperature +20±5 Humidity +65%±20% 4.2 Testing Tools 4.2.1 Voltage meter: 0.5 level or higher as required in IEC51/IEC485. Internal impedance exceeds 10KΩ/V. 4.2.2 Current meter: 0.5 level or higher as required in IEC51/IEC485. Internal impedance should be less than 0.01Ω/V(including wires). 4.2.3. Micrometer caliper: With precision of 0.02mm. 4.2.4. Internal impedance meter: Alternating current of 1000HZ, connector measuring equipment with sin wave of 4. 4.2.5: Impedance loaded meter: Value of impedance is with +5% error allowed (including external wires). 4.3 Test methods and benchmarks Items Test Methods Benchmarks batteries shall be free from any stains; scratches or 1.Appearance: eyeballing deformations, which may reduce the commercial value when visually inspected 2.Size: caliper measurement The size shall comply with the specified size as the attached drawing 3.Insulate impedance measured with a Megger overpack and battery electrode between the degree of insulation outer sleeve shall exceed 10 MΩ

4.Weight using disk-scale measurement approximate 25.0 g 5.Charge Voltage 6.Open circuit voltage: (O.C.V.) 7.Closed circuit voltage: (C.C.V.) 8.Internal impedance 9.capacity 10.High Drain Discharge 12.Over-charge 11.Selfdischarge 13.Overdischarge Following a period of discharge at 300mA down to a terminal voltage, then standard charge, the cell voltage shall be tested at 5 minutes before finishing charging period, the open circuit voltage of the cell shall be tested within 1 hour. period, the closed circuit voltage of the cell shall be tested with a 0.86 Ω Impedance loaded within 1hour period, the internal impedance of the cell shall be tested within 1 hour period, the cell shall be tested within 1 hour based discharged at 300 ma down to a terminal voltage of 1.3V; To discharge at 1500mA to 1.2V within 1 hour after finished standard charge Discharge at 300 ma to a terminal voltage of 1.3V, then standard charge to put aside for 28 days, after discharge again at 300mA to 1.3V to test capacity. Following a period of discharge at 300 ma down to a terminal voltage of 1.3V,first standard charge and then charge for 48hrs at 150 ma by a constant voltage holding at 1.9V. Then discharge at 300mAh to test capacity. Following a period of discharge at 300 ma down to a terminal voltage of 1.3V, combine the cells with a 0.86 Ωper cell load. After stored for a period of 24 hours, standard charged and then discharge at 300 ma The voltage shall be less than 2.0 V The O.C.V. shall exceed 1.8 V. The C.C.V. shall exceed 1.6 V. The internal impedance shall not be more than 30mΩ. The capacity is equal or above the minimum capacity The Capacity is equal or above 54 min The subsequent capacity shall not be less than 60% of initial capacity. No deformation, no leakage Capacity not be less than minimum capacity No deformation The subsequent capacity shall not be less than 80% of rated capacity

14.Cycle Life 15.Leak-proof test 16.Vibration test 17.Free falling: (Drop) 18.Safety testing 19. Safety Valve Start Performance (Over discharging) 20. Safty Valve Start Performance 1Discharge to 1.3V at 300mA; 2Charge 120 minutes at 750mA constant current with a voltage holding at 1.9V; 3Constant voltage holding at 1.9V to charge 90 minutes until current drops to 50mA; 4Rest for 15 minutes; 5Discharge to 1.2V at a constant current at 1500mA; 6Repeat steps from 2 to 5 until the capacity drops to 60%. Standard charge and store for 14 days under the following storage conditions : 33±3, Relative humidity: 80%±5%. Store the cell more than 24 hours after standard charge, following vibration tests over an amplitude of 4 mm (0.1575 inches) at a frequency of 16.7 Hz(1000 cycles per minute) and repeated through any axes during 60mins Store the cell more than 24 hours after standard charge, following a drop test from 450mm (17.717 inches ) on to a hard-wood board in a vertical axis 3 times. to store it for 1 hour after standard charged, and to make positive and negative electrode short-circuit with a wire with the section 0.75mm 2 min and shortest length, the short-circuit time is 1 hour to be charged with 1500 ma for 5 hours to be charged with 1500 ma for 5 hours The cycles life shall exceed 200 times No leakage of electrolyte in liquid form shall be observed The subsequent fluctuation of open circuit voltage and internal impedance shall be less than 0.02 V and 5 mω respectively, and the surface of cell has no obvious change. The subsequent fluctuation of open circuit voltage and internal impedance shall be less than 0.02 V and 5 mω respectively, and the surface of cell has no obvious change. It shall not explode. However, leakage of electrolyte, external deformation or outer sleeve cracking is permitted. safety valve can work normally, no breakage, leakage, distortion and out package breakage are allowed No explosion, but leakage, distortion and out package

(over charging) 21.To discharge at low temperature to be stored for 24 hours at 0±2, and discharged at 300 ma at 0±2 breakage are allowed discharge duration shall exceed 3 hour(s) 30 min(s) 5. The transportation and storage 5-1 During transportation, it should be prevented from fierce vibration, impact,extrusion, insolating or drenching under clean, dry and ventilated place. Applicable in transportation by automobile, train, steamboat and airplane. 5-2. It must be stored at -5 ~ +35, and put in the clean, dry and ventilated place with relative humidity 75% max.. It must be kept away from corrodent substance, fire hazard and heat resource. 6.0 Ni-Zn battery must be charged special Ni-Zn Charger, if it happens accident when you charge Ni- Zn battery with other battery charger, can not take any responsibility. 7. Warning and Security To prevent the impact of equipment failure caused by the battery, and to make sure the security of circuit and battery set, please consider below things when design and produce the production equipment. Please put it into your instruction. Danger! Violation of the following matters will result in Ni-Zn battery leakage, heat, explosion, fire and serious personal injury! Prohibited to throw the Ni-Zn battery into fire or heat! Prohibited to collide or throw Ni-Zn battery! Don t weld the lead on the Ni-Zn battery directly. Don t put the Ni-Zn battery on a place which is more than 1.5 meter in case of dropping. Don t drop it at the height of more than 1.5 meter. Don t connect the positive pole and electrode pole directly of Ni-Zn battery, such as leading wire. If the tab terminal of poles doesn t set insulation covering, please don t transport or store. Please don t touch the metal necklace, key or any other conductive material. Please use special carton when transport or store. Must use the charger appointed to charge Ni-Zn batteries, and follow the instructors. Prohibited to disassemble Ni-Zn batteries. It will cause external or internal short circuit, and the exposed parts will have chemical reaction then result in very dangerous heat, explosion, fire or splash of electrolyte. Warning!!

Don t contact Ni-Zn batteries with water, sea water or other oxidation reagents, which will cause rustiness and heat. If batteries get rusty, explosive decompression valve won t work and will lead to explosion. Don t over-charge Ni-Zn batteries, that is, don t continually charge Ni-Zn batteries despite the designed charging time. If the Ni-Zn batteries are not fully charged within the designed charging time, please stop to charge. The delay of charging time will lead to leakage, heat and explosion. It is forbidden for more than 20 pcs batteries in series. Because it will result in leakage, getting shock or giving off heat. Don t disassemble the Ni-Zn battery, as it will result in short-circuit, leakage, giving off heat, catching fire and explosion. Don t use the Ni-Zn batteries when they are leakage, any color deterioration, distortion or other changes are found. Otherwise it will get hot, catching fire or explosion may happen. Please keep the Ni-Zn batteries and other electronic products related to Ni-Zn battery away from baby, children, to avoid accident of swallowing of Ni-Zn battery. If there is any accident, please go to doctor s. To use new Ni-Zn battery when the working time of the battery is far short from the initial working time, as the cycle life of this Ni-Zn battery is finished. 8. Others: 8-1. Conrad Electronic SE reserve right to revise the specification without notification; 8-2. Anything not mentioned in this specifications, customer and Conrad Electronic SE should discuss to get a solution; 8-3. Conrad Electronic SE does not undertake any responsibility for the accidents caused by actions not matching with specifications.