The DL8000 Preset Controller. The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers



Similar documents
ROC800L Liquid Application Software

ROC800-Series Advanced Pulse Module

SupportNet Technical Services

Enhance Your Oil & Gas Production and Transmission Operations

OpenEnterprise. Lifecycle Services

Bristol ControlWave Redundant Control

Smart Wireless Solutions. Intelligent Well Production Starts Here

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

FloBoss 104 Flow Manager

Rosemount Analytical s X-STREAM XE Web-Browser Interface Takes Process Analysis to the Next Level

FloBoss 107 Flow Manager

Wireless Field Data Backhaul

Rosemount 333 HART Tri-Loop

Daniel Venturi Tubes and Flow Nozzles Brochure

Electronic Flow Switches

OpenEnterprise Terminal Services Reference Guide (V2.83)

Tank Gauging & Inventory Management Solutions

11 Rules for Specifying a Successful SCADA System By Steve Hill

Monitoring Water Quality For Today s Demanding World

FLOW COMPUTERS METERING, MONITORING, & DATA ACQUISITIONS. Sami Halilah Dynamic Flow Computers Houston, Texas

PROGRAMMABLE LOGIC CONTROL

S-series Mass Connection Solutions

DeltaV SIS for Burner Management Systems

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

Techniques for Interconnecting Smart Wireless Gateways to ProSoft RadioLinx Devices

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Micro Motion Net Oil Computer Software and NOC System

Table of Contents. TransformerIQ FAQs 1

PRODUCT & SERVICE SUITE LACT CONTROL AND DATA MANAGEMENT

In-Line Electronic Flow Switches

M-series FOUNDATION Fieldbus I/O

SCADA System Fundamentals

NEW GENERATION PROGRAMMABLE AUTOMATION CONTROLLER

Section TELEPHONE AUTOMATIC DIALER SYSTEM

SECTION PROGRAMMABLE LOGIC CONTROLLERS AND COMPUTER CONTROL SYSTEM PART 1 GENERAL Summary. A. Section Includes:

Current Loop Application Note 1495

Sanitary Type Electronic Flow Switches

Batch Historian. Introduction. Benefits. Configuration-free, batch-based data collection. Reliable data retrieval through data buffering

V-CONE METERING PROGRAM User Manual

Wireless Remote Video Monitoring

Straton and Zenon for Advantech ADAM Copalp integrates the straton runtime into the ADAM-5550 device from Advantech

REMOTE MONITORING AND CONTROL SYSTEM


TABLE OF CONTENT

Höllerer + Bayer GmbH. Software- und Systemhaus. vertrieb@hoellerer-bayer.de. LMS-TAS Software

Level Instrumentation for the Refining Industry

Rosemount 333 HART Tri-Loop

Measurement Services Inspectorate America Corporation

S-series SQ Controller

Quick Start Guide , Rev DA March Rosemount 8714D (Calibration Standard) Magnetic Flowtube Simulator

M-series Virtual I/O Module 2

Replacing Displacers with Guided Wave Radar

Micro Motion Coriolis Interface Module User Manual (for ROC800-Series and FloBoss 107 Controllers)

Designed for multi-injector endurance testing, the

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

ROC Protocol Specifications Manual

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Natural Gas Well Automation using Kingfisher RTU Products

S-series DeviceNet Interface Card

ControlWave Micro. Features. CPU Options. Base and Expansion Units. Product Data Sheet D301671X012 September Remote Automation Solutions

Rack mounted telephone- and leased line modem for industrial applications

PLCs and SCADA Systems

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

SAGEON SITE MONITOR (SSM) Application Note AN

WIRELESS REMOTE MONITORING OF CATHODIC PROTECTION SYSTEMS. John Hawkyard MICorr Deputy General Manager Rawabi Corrosion Technology Co Ltd Al-Khobar

DeltaV Remote Client. DeltaV Remote Client. Introduction. DeltaV Product Data Sheet. Remote engineering and operator consoles

SCADA and Monitoring for Solar Energy Plant

Wireless Remote Video Monitoring

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

Using installed Fieldbus Wiring to carry Ethernet Communications

Application of the Orifice Meter for Accurate Gas Flow Measurement page 1. Application of the Orifice Meter for Accurate Gas Flow Measurement.

SAMPLE REPORTS. Contents

Temperature & Humidity SMS Alert Controller

Model: DC-A2IO Advanced HVAC Controller

Base Station. Base Station. Introduction. DeltaV Product Data Sheet. Adaptable work environment. Scalable to suit your needs. Dedicated functional use

Web-Based Remote Monitoring & Datalogging

Tank Gauging Products for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory Measurement

G4 Digital DC Output Modules. G4 Digital DC Output Modules. Features. Description. Part Numbers

DeltaV Event Chronicle

Rosemount 1199 Submersible Seal

THERMAL MANAGEMENT SOLUTIONS

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Process Alarm Solutions

M-series MD Plus Controller

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Digital and Analog I/O

Introduction To SCADA and Telemetry

Agilent 4338B Milliohm Meter

ProfessionalPLUS Station Software Suite

THE INPUT/OUTPUT SYSTEM. Key Points

Basic Fundamentals Of Safety Instrumented Systems

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

Emerson Process Management Capabilities for SCADA Security Systems

How To Use The Deltav System With A Large Data File System

Process Instrumentation

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Sigma Control PC INSIDE. 97 psi 187 F R on load

Plant automation and telecontrol in one system. SIMATIC PCS 7 TeleControl SIMATIC PCS 7. Answers for industry.

Transcription:

The DL8000 Preset Controller The Ideal Device for Controlling and Measuring the Loading of Liquid Hydrocarbons into Transporting Tankers

Reliability, ruggedness, flexibility, and accuracy all in one package has always had a strong presence in the liquids measurement and batch controller market. After success with PetroCount and DanLoad 6000, we now offer the new DL8000 Preset Controller. The DL8000 extends our product line and measurement capability to lead the industry by offering measurement in accordance with the latest API (American Petroleum Institute) recommendations. Contact your applications engineer or Emerson sales representative to discuss how we can help you to migrate your system to the next generation so that you can realize the benefits of the latest development in liquids measurement and batch control. The DL8000 is a Preset Controller designed to manage the loading of hydrocarbon liquids into tank trucks, rail cars, ships, storage tanks, and other vessels loaded in batch style for transportation or storage. Full connectivity to Emerson s DeltaV Process Control Systems with ROConnect enables the customer to drive maximum benefit from remote control and smart sensors and perform diagnostics using the Emerson Asset Management software. This investment improves productivity and reduces maintenance cost. Using Emerson s PlantWeb Architecture, HART technology expands data retrieval beyond the typical SCADA and Process Parameters world of Modbus and into diagnostics data for performance and analysis, predictive maintenance, and equipment health analysis that adds value to the process control system. HART protocol is easily added to the DL8000 and with ROConnect for the ROC product line, the DL8000 is easily made a part of any Emerson PlantWeb architecture.

Higher Confidence with Precise Measurement New and improved the next generation electronic preset controller The Emerson DL8000 Preset Controller is based on the popular and high performing ROC800-Series remote operations controller. This new design delivers accurate measurement and reliable control, local or remote, via Ethernet or serial (Modbus) communications. The preset is capable of double precision math. Computations are made in accordance with Institute of Electrical and Electronic Engineers (IEEE) standards and utilize double-precision floating point math to minimize meter-tometer differences, make volume corrections highly precise, and avoid premature roll-over of totalizers. Features The DL8000 now provides support for ethanol volume correction based on either the OIML-R22 (1973) or ABNT NBR 5992 standards. Configuring a unit for ethanol product measurement is simple, requiring only the selection of ethanol fluid type, the selection of the preferred standard volume correction and a user-entered mass percentage of ethanol for the ethanol/water mixture. The DL8000 features a straight forward, fill-in-the-blanks approach to configuration and covers a wide variety of liquids including crude oil, refined products, special application products, lubricating oils, and light hydrocarbons. The DL8000 is packaged in a Class 1 Division 1 explosion proof enclosure or a Class 1 Division 2 enclosure. The DL8000 carries approvals from the NTEP National Test and Evaluation Program under the US National Council on Weights and Measures, and CSA/UL approval. Improve Measurement Integrity The DL8000 calculates volume flow thoroughly and precisely, exceeding the capabilities of other presets. We do this by: 1. Correcting volume measurements for changes in temperature in accordance with the American Petroleum Institute (API) MPMS Chapter 11.1, 2004 tables, ASTM-D1250-80, ASTM D-1250-04, API 2540-80, and ISO 91.2. 2. Correcting for changes in pressure in accordance with the American Petroleum Institute (API), MPMS sections 11.2.1, 11.2.2, 11.2.1(M), 11.2.2(M) for Automatic Pressure Compensation. 3. Correcting for changes in density using density signals in the form of a frequency signal, a 4 20 ma signal, or through digital communications. 4. Checking for pulse fidelity in a dual pulse meter by monitoring the dual pulse inputs for integrity in accordance with API Manual of Petroleum Measurement Standards, Chapter 5.5, level B. 5. Performing linearization of Meter factors or K factors using up to 12 points to ensure accuracy over the entire range of flow measurement. This gives the DL8000 the ability to measure a wider variety of hydrocarbon liquids more precisely. 3

Built for Reliability and Lower Operation Cost Flow properties calculations based on the latest American Petroleum Institute (API) recommendations for best accuracy and repeatability Sequential and ratio blending of up to four products Measurement and control of injected additives Capable of double-precision math, reducing meter-to-meter differences and avoid early totalizer rollover Corrections for temperature, pressure, and density Modern electronics with an excellent reliability history User-friendly interface designed for the truck driver or station operator Easily configurable for different liquids and for batch loading and reporting Built-in surge protection Wide-ranging communications capability including Ethernet, EIA232, and EIA485 Optical isolation of I/O for circuit protection AC sensing of permissive circuits for safe loading AC or DC control of pumps and valves Fully programmable for PLC (Programmable Logic Controller) tasks using the FST (Function Sequence Tables) or any of the languages defined by IEC standard 61131-3 using Emerson s DS800 Programming tool with ladder logic, function block diagrams, structured text, instruction lists, or sequential function chart programming Multiple languages available for display Archival storage of 450 alarms and 200 transactions with up to four batches per transaction Storage of the last 1000 weights and measures events Integral Weights and Measures switch Independent permissive sensing of AC power Digital valve control with automatic high flow rate recovery Independent temperature compensation methods for individual products User-entered vapor pressure for light hydrocarbons Electrical isolation and built-in surge control, protecting electronics from lightning and user wiring errors Selection of a standard reference temperature as 60 F, 15 C, 20 F, or user selectable Explosion-proof enclosure Optional NEMA 4 enclosure, Class 1, Division 2 4

Three Product Ratio Blend The DL8000 is capable of performing all blending, measurement, control, and monitoring needed to provide highly productive and rapid operations for most common loading configurations used in the industry. The flow diagram above illustrates an installed DL8000 performing ratio blending and additive injection for three products flowing simultaneously. This device is also capable of sequential blending and other more simplified applications such as single product streams. 5

Expandable Configuration Options The Emerson DL8000 Preset offers great flexibility and I/O expansion capability. As your system needs grow, you can include additional I/O to expand the capabilities of the system, reducing the per measurement cost and easily increasing the number of valves, pumps, products, and additives to be controlled. The following input modules are available: AC I/O Module The module has 6 channels and each channel can be configured as an input or output channel for sensing AC signals or providing AC power for pump and valve control. APM Module The Advanced Pulse Module has four inputs that can be configured for two sets of paired pulses from a dual pulse turbine or positive displacement meter and provide pulse integrity measurements as recommended by API MPMS Chapter 5.5, level B,C, and E. Each input can also be configured as a single pulse input from devices generating single pulse stream outputs such as single pulse turbine meters, positive displacement meters, coriolis meters, or ultrasonic flow meters. The pulse inputs can support up to 5Khz inputs. One channel can be configured as a pulse output to feed a totalizer. In all configurations, the APM has high speed interrupt-driven detector switch inputs for use in proving applications. This interrupt is used in the pulse accumulation between the detectors as well as the pulse interpolation calculations for use with small volume provers. The APM s detector input channels can be used with individually wired detector switches or detector switches that are wired in series from the prover on the same cable. The detector inputs can be used with relays, open collector/open drain type solidstate switches, and other two-state devices. The APM module is equipped to accept densitometer frequency or pulse inputs on the third pulse input from a densitometer to measure live density. RTD Module - The Resistance Temperature Detector (RTD) module has 2 channels, each capable of accepting a 3- or 4-wire RTD input. Analog Input Modules - Each AI module is a 4-channel device, capable of accepting four 4 to 20 ma signals, or four 1 to 5 Vdc signal from an analog sensor. Analog Output Module Each AO module is capable providing up to four 4 to 20 ma or 1-5 Vdc control signals. Power Options - There are options for 120/250 Vac, 24 Vdc or 12Vcd input power. DC I/O - There are up to 8 channels per module of discrete DC input sensing and up to 5 channels per module of DC output control options. Communications module There are modules for EIA232, EIA422/485, and dial-up modem. 6

Flexible Configuration Tools Improve Productivity Flexible Configuration Tool The DL8000 can be configured using Emerson s Windowsbased ROCLINK 800 software package. ROCLINK 800 runs on almost any laptop or desktop personal computer and uses a simple fill-in-the-blanks approach to selecting product, measurement device, blending scheme, and other setup and configuration parameters. You can perform configuration and data retrieval on-site or remotely over an Ethernet or serial communications connection. The remote capability can be a tremendous cost saver by reducing the need for on-site travel. Help screens are provided and are accessed either from the Help menu or in a context- sensitive fashion. This makes it easy to obtain information on almost any topic.

Find us around the corner or around the world For a complete list of locations please visit us at www.emersonprocess.com/remote Global Headquarters 6005 Rogerdale Road Houston, TX, USA 77072 T +1 281 879 2699 F +1 281 988 4445 www.emersonprocess.com/remote Europe Unit 8, Waterfront Business Park Dudley Road, Brierley Hill Dudley, UK DY5 1LX T +44 1384 487200 F +44 1384 487258 North America and Latin America 6005 Rogerdale Road Houston, TX, USA 77072 T +1 281 879 2699 F +1 281 988 4445 2004-2013, a business unit of. All rights reserved. Ltd, (UK), is a wholly owned subsidiary of Emerson Electric Co. doing business as, a business unit of. FloBoss, ROCLINK, ControlWave, Helicoid, and OpenEnterprise are trademarks of. AMS, PlantWeb, and the PlantWeb logo are marks of Emerson Electric Co. The Emerson logo is a trademark and service mark of the Emerson Electric Co. All other marks are property of their respective owners. The contents of this publication are presented for informational purposes only. While every effort has been made to ensure informational accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. reserves the right to modify or improve the designs or specifications of such products at any time without notice. All sales are governed by terms and conditions which are available upon request. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any product remains solely with the purchaser and end-user. Middle East and Africa Emerson FZE PO Box 17033 Jebel Ali Free Zone - South 2 Dubai, UAE T +971 4 8118100 F +1 281 988 4445 Asia Pacific 1 Pandan Crescent Singapore 128461 T +65 6777 8211 F +65 6777 0947 D301261X012 / Printed in USA / 12-13