ELECTRIC FENCE ENERGISER



Similar documents
ELECTRIC FENCE ENERGISER

616, 626, 636 & 646 Keypads

INSTRUCTION MANUAL PC5OO WITH PC5OORK KEYPAD

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

PC Tab Security System INSTRUCTION MANUAL

Flarm LED indicator. Version 1.1

HILLS Series LED Code Pad User Manual


astec Integrated Alarm System USER GUIDE

Using your LED Plus keypad

Contents 1. Terms you may neeed to know 2. Keypad Lights 3, 4. Keypad Buttons 5

PowerWave-8. Users Operating and Programming Guide Version zone Control panel Communicator

Model SRMD Setra Remote Monitoring Display

CA-125 Owner's Manual

LCD and 16-Zone LED Keypads. User s Manual

642 LCD Keypad User Manual

Using Your GEM-P400 Security System

RT-200 HI-TEST ROPE TESTER

CA60 Plus Software Version 3.1 User Manual May 2000

LCD5500Z / PKP-LCD v3.x Installation Instructions

e-ask electronic Access Security Keyless-entry Consumer Manual FCC ID: TV2EFOB1 (UM12 ~ )

10-Zone Spectra LED Keypads

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

CONTENTS 4. HOW TO UNSET THE PANEL...7

TERMS AND CONDITIONS

Maintenance Manual PC6010. WARNING This manual contains information on limitations regarding product use and function

User s Information Guide R1A

Automatic Phone-Out Home Monitoring Systems

TC Electronic Extended Warranty Policy

2 4PI175 issue 1_6/01. How to unset system in alarm. Programs 1, 2 and 3. Access codes. How to operate Personal Attack

PK5500 v1.1 Installation Instructions

Quick Installation Guide TK-209K TK-409K

HILLS Series LED Code Pad User Manual


NetworX Series. NX- 4/8 Code Pad. User Manual (Australian Version)

User Guide. RX-406 LED Keypad For CAPTAIN-I Ver.5.5 & up

EKP1 LED KEYPAD. Owner's Manual. Use with AV9000 & SC800/1600 Series Control panel

XR1. Intruder alarm system Operating Instructions. Unset system indications. Set System indication

MP3-Digital Audio Player. MP55BK User Manual

MOTOROLA MOBILITY INC. LIMITED GLOBAL WARRANTY MOTOROLA TABLET COMPUTER

Advantium 2 Plus Alarm

CA 1050 Owner s Guide

How To Set A Timer On A Gg System

Intruder alarm system Operating Instructions

ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL. User s Guide

Wireless Home Security System Product Manual (Model #80355)

NetworX NX-6V2. LED Keypad User Manual

Touch Tone Controller. Model TR16A. Owner s Manual

User manual. Your best protection against theft and loss. (Android) Made for

Understanding the Code Pad lights...4. Code Pad tones...5. Fully arming the system On MODE...6. Fully arming the system - Quick Arm MODE...

PRODUCT WARRANTY. Page 20

FXM Communication Manual

Alarm Clock USER GUIDE

AUTHORIZED FITNESS RESELLER PROGRAM. A Reseller is a Retailer that purchases Garmin products through one of our Authorized Fitness Distributors.

HUNTER-PRO 32 Ver. 3.8 Intruder Alarm System RXN-9/416 User Guide

Digiplex LCD Keypad DGP-641. User s Manual

Solution 16 plus. User Guide Security System

VIBRATION WATCH with:

Digiplex LCD Keypad DGP-641. User s Manual

User Manual (English)

Limited Warranty Letter for BYD Photovoltaic Module

HYBRID NETWORK VIDEO RECODERS WITH INTERNAL RAID RECOVERY PROCEDURE

Limited Warranty. CAUTION: Federal law restricts this device to sale, distribution and use by or on the order of a physician.

ELECTRONIC ENGINEERING LTD. PowerWave zone Control panel Communicator. User s Operating and Programming Guide. Version: 6.

Value Extended Warranty and Premium Extended Warranty. Terms and Conditions

Users Guide to Keypad Functions

FIRST ALERT INSTRUCTION MANUAL FOR FA 270 KEYPADS SECURITY SYSTEM

INSTRUCTION MANUAL LCD-6OO SECURITY STATION

Auto Dialer. Manual E-921APQ E-921GPQ

AD-01 Slave Auto Dialer. Owner s Manual

ELECTRONIC ENGINEERING LTD. Runner Series WIRELESS AND WIRED CONTROL PANEL. User s Guide. Version

TAC2C & TAC2D TAC1 RETROFIT KIT FOR CROWN JEWEL & DOORKING 1812 SYSTEMS

GPS 35 USB. installation and quick start guide

2-Way Wireless Indoor Siren Installation Guide

D24 ALARM CONTROL PANEL USER S MANUAL REVISION 1.1 A$12.00 INC GST

INSTRUCTION MANUAL PC255O

EASY LED Oy General Terms of Sale

1 For All Non-Programmable Digital Thermostat

Cooler Master Limited Warranty Policy

8 Digital Photo Frame Instructional Manual

Control panel software versions 2.00 and beyond.

SECURITY SYSTEM NOTES

NSI DDR DIMMING RACK POWER DISTRIBUTION UNIT

Vibrating Alarm Clock VAC500

Accenta/Optima. User Guide. Servicing Organisation (Installer) name: Telephone Number: Date of Installation: Account Number: Honeywell Security

Transource Warranty & Support Agreement

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

TABLE OF CONTENTS INTRODUCTION 2 PACKAGE CONTENTS. 3 TECHNICAL REQUIREMENTS... 3 PRODUCT SUPPORT... 3 SPECIFICATIONS 4 INSTALLATION GUIDE...

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

WTSL-SN-1 Alarm Control Unit with Wi-Safe 2 Installation and User Guide

Security System Owner s Manual

Owner s Guide. ca6554

24.2L M.A.N. V12 Engine Module

COMPLIANCE WITH LAWS, CODES, AND STANDARDS

BancTec, Inc. PRINTER SERVICE CONTRACT

2GB MP3 Player USER GUIDE

CAPTAIN 6. USER GUIDE System ver Zones Intruder Alarm System. PIMA Electronic Systems Ltd.

SECURITY SYSTEM NOTES

2-3 SAS/SATA II HDD Canister USER S MANUAL XC-23D1-SA10-0-R. Document number: MAN A

Powerware Relay-Serial Card User s Guide

Transcription:

GROUP OF COMPANIES MERLIN 4 Electric Fence Energizer USER MANUAL ELECTRIC FENCE ENERGISER E-MER4

USER MANUAL Table of Contents INTRODUCTION.. 3 COMPANY PROFILE 3 GUARANTEE 4 USING YOUR KEYPAD 5-8 WHAT THE LIGHTS MEAN... 9 MERLIN 4 Introduction & Company Profile

I N T R O D U C T I O N Thank you for choosing our product! NEMTEK Electric Fence Energizers are designed and manufactured to provide many years of reliable use, if installed and maintained correctly. The guidelines provided in this manual will assist you with the basic operation and maintenance of your MERLIN 4. The MERLIN 4 is designed and manufactured in South Africa for the international market. More information on our products, SABS test reports and general information is available on our web site at: http://www.nemtek.com C O M P A N Y P R O F I L E The NEMTEK Group of Companies manufacture and distribute intelligent electronic security and perimeter control systems and have been involved in the security industry since 1990. We have our own research and development team, designing and manufacturing a full range of globally competitive electric fence energizers and related products NEMTEK is continually updating its products according to international standards in order to ensure the highest quality products and continuous customer satisfaction. NEMTEK GROUP OUTLETS: Nemtek Security Randburg Tel: +7 11 46-883 Fax: +7 11 46-713 Nemtek Security Warehouse Edenvale Tel: +7 11 453-1970 Fax: +7 11 453-1858 Website: www.nemtek.com E-mail: nemtek@nemtek.com MANUFACTURED IN SOUTH AFRICA 3

Guarantee G U A R A N T E E The MERLIN 4 energizer, manufactured by IO Tech Manufacturing (Pty) Ltd, is guaranteed for a period of one year from date of sale against defects due to faulty workmanship or materials. IO Tech Manufacturing (Pty) Ltd will, at its discretion, either repair or replace a product that proves to be defective. IO Tech Manufacturing (Pty) Ltd guarantees the product, when properly installed and used in line with the specification as determined by IO Tech Manufacturing (Pty) Ltd from time to time, will execute its function of generating a suitable potential. IO Tech Manufacturing (Pty) Ltd does not guarantee that the operation of the product will be uninterrupted and totally error free. Faulty units must be returned to Nemtek, Units 4 & 5, 64 Vervoer Street, Kya Sand, Randburg, Gauteng, South Africa OR Nemtek Security Warehouse, Unit 4, Meadowdale Park, Cnr. Herman & Dick Kemp Roads, Meadowdale, Edenvale, Gauteng, South Africa. Buyer shall pay all shipping and other charges for the return of the product to Nemtek or Nemtek Security Warehouse. L I M I T A T I O N O F G U A R A N T E E The guarantee does NOT apply to defects resulting from acts of GOD, modifications made by the buyer or any third party, misuse, neglect, abuse, accident and mishandling. E X C L U S I V E R E M E D I E S The remedies provided herein are IO Tech s sole liability and buyer s sole and exclusive remedies for breach of guarantee. IO Tech Manufacturing (Pty) Ltd shall not be liable for any special, incidental, consequential, direct or indirect damages, whether based on contact, tort, or any other legal theory. The foregoing guarantee is in lieu of any and all other guarantees, whether expressed, implied, or statutory, including but not limited to warranties of merchantability and suitability for a particular purpose. 4

Using your control panel SWITCH THE FENCE ON / OFF To switch the fence On or Off, enter your four digit PIN followed by the key. If the red ON light is lit or flashing, the fence is energized. Don t pause for more than 5 seconds while entering the digits, or the control panel will reject your PIN number. If you make a mistake while entering your PIN, press the key and start again. An incorrect PIN will cause the control panel to beep 5 times. The default master (User 1) PIN is 1 3 4. The default user (User ) PIN is 5 5 5 5 AFTER AN ALARM OCCURS Enter your PIN and press the key. This will silence the buzzer and siren. It will switch the fence off. One of the ALARM lights will flash or stay lit to indicate the source of the alarm. A flashing indicator illustrates that the fault condition persists. A permanently lit indicator notifies the user that the fault no longer exists. CHANGE THE VOLTAGE ON THE FENCE 3 Enter your PIN and press the * key, enter the digit 3, then press the key. When the fence is on and in low voltage mode, the red ON light will flash. The red ON light will stay permanently lit if the fence is in high voltage mode. Use the low voltage mode when children are in the fence vicinity. BYPASS THE FENCE ALARM 1 Enter your PIN and press the * key, enter the digit 1, then press the key. The FENCE ALARM light will start flashing slowly to confirm the fence alarm is bypassed. To cancel the bypass, repeat the same sequence of keys. BYPASS THE SIREN AND STROBE LIGHT (SILENT ALARM) 4 Enter your PIN and press the * key, enter the digit 4, then press the key. The beeper in the control panel will still be active. 5

Using your control panel UN-BYPASS THE SIREN AND STROBE LIGHT 7 Enter your PIN and press the * key, enter the digit 7, then press the key. MAKE THE GATE ALARM IMMEDIATE 7 Enter your PIN and press the * key, enter the digit, followed by the digit 7, then press the key. The GATE ALARM light will start flashing, with a cadence of one flash every 5 seconds, to confirm the gate alarm is immediate. MAKE THE GATE ALARM DELAYED 4 Enter your PIN and press the * key, enter the digit, followed by the digit 4, then press the key. The default gate delay is 4 minutes. BYPASS THE GATE ALARM Enter your PIN and press the * key, enter the digit, then press the key. The GATE ALARM light will start flashing slowly to confirm that the gate alarm is bypassed. To cancel the bypass, repeat the same sequence of keys. TURN THE GATE CHIME ON / OFF Press the * key, enter the digit, then press the key. The control panel will beep twice to confirm that the gate chime is turned off and three times if it s turned on. If the chime is on, the control panel will beep twice if the gate closes and three times if it opens. BYPASS THE SERVICE ALARM 9 Enter your PIN and press the * key, enter the digit 9, then press the key. The SERVICE ALARM light will start flashing slowly to confirm that the service alarm is bypassed. To cancel the bypass, repeat the same sequence of keys. 6

Using your control panel CHANGING A USER PIN Master PIN User (1-) New PIN New PIN 0 Enter your master PIN, press the * key, enter the digit 0, then press the key. Enter the user number (1-), and push the key. User number 1 is the master PIN. Enter that user s new PIN and press the key. Enter the new PIN again and press the key. If the new PIN is accepted, the control panel will beep twice. If you make a mistake while programming, or if the system rejects the new PIN, the control panel will beep three times. The default master user PIN is 1 3 4. Changing the PIN is only possible when the energizer is ON. Check the new PIN. If not accepted, the previous PIN will remain valid. KEY DEFINITIONS: Four digit Personal Identification Number (PIN) NOTES: The Master User (i.e. User 1) can bypass alarm conditions. The Normal User (i.e. User ) can only turn the energizer on/off. The installer may alter certain energizer parameters such as voltages and delay times. 7

What the lights mean WHAT THE LIGHTS MEAN Condition: FENCE GOOD Power ON Good On Fence Gate Service ON OFF OFF OFF FENCE OFF ON OFF OFF OFF OFF OFF MAINS FAILURE BATTERY LOW BATTERY FLAT FENCE ALARM FENCE LV MODE FENCE BYPASS GATE OPEN GATE BYPASS INSTANT GATE SERVICE ALARM SERVICE BYPASS OFF OFF ON FAST FAST PULSE (5 SEC) PULSE (5 SEC) FAST FAST Remarks Fence on, working properly Fence off, working properly System on battery power Check mains, call for service Check mains, call for service Problem on fence Fence in low voltage mode Fence alarm switched off Gate is open Gate alarm switched off Instant gate alarm Call for service Service alarm switched off ALARM MEMORY (ON) (ON) (ON) Old alarm. Turn off/on Rev 1.0 8