Medical Device Classification



Similar documents
Medical Devices. Notified Bodies and the CE certification Process for Medical Devices. European Surgical Robotics Demonstration Day

Med-Info. Council Directive 93/42/EEC on Medical Devices. TÜV SÜD Product Service GmbH

Supplier Quality Agreements

How to apply for Medical Device License in Taiwan

Medical Device Directive 2007/47/EC What is New? Are we moving towards Drug Rules?

How To Know If A Mobile App Is A Medical Device

Process Validation for Medical Devices

Registration of Class B Medical Devices

Regulatory Requirements for Medical Device Calibration Programs

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Conformity assessment certification

UNDERSTANDING THE EC DIRECTIVE 98/79/EC ON IN VITRO DIAGNOSTIC MEDICAL DEVICES

Reporting Changes to your Notified Body

GUIDELINES ON MEDICAL DEVICES. IVD GUIDANCES : Borderline issues A GUIDE FOR MANUFACTURERS AND NOTIFIED BODIES

Safeguarding public health The Regulation of Software as a Medical Device

CE Marking: Your Key to Entering the European Market

Clinical evaluation Latest development in expectations EU and USA

Guidance for manufacturers and Notified Bodies on reporting of Design Changes and Changes of the Quality System

WHITEPAPER: SOFTWARE APPS AS MEDICAL DEVICES THE REGULATORY LANDSCAPE

Medical Devices: CE Marking Step-by Step

Plamena Entcheva-Dimitrov, PhD, RAC On-line Course. 1

Medical Device Regulatory Requirements for Taiwan

Want to know more about the Notified Body?

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

What is a medical device? Medical Devices: Roadmap to Market. Kathryn Klaus, Esq.

Sarah Chandler A/Head, Regulatory and Scientific Section Medical Devices Bureau

How to Use the Design Process to Manage Risk: Elements of Design Controls and Why It Matters

RAPS ONLINE UNIVERSITY

Regulatory Considerations for Medical Device Software. Medical Device Software

Medidée Services SA. Nano-Tera.ch. 05 February 2015 part 12. Special Issues Q&A Session. Michael Maier

2002 No. 618 CONSUMER PROTECTION. The Medical Devices Regulations 2002

Medical Device Software Do You Understand How Software is Regulated?

Boost the Success of Medical Device Development With Systematic Literature Reviews

ISO 9001 for Purchasing Professionals

GUIDELINES ON MEDICAL DEVICES

April 7, Acclarent, Inc. Mr. James Patrick Garvey II Sr. Manager, Regulatory Affairs 1525-B O'Brien Drive Menlo Park, CA 94025

Combination Products. Presented by: Karen S. Ginsbury For: IFF March PCI Pharma

Med-Info Regular Information Bulletins for the Medical Device Industry

Basic Information about the European Directive 93/42/EEC on Medical Devices

Medical Device Software

CDRH Regulated Software

BSI Unannounced Audits

BSI Road Show: September 8 th to 15 th, 2014

Manual for ITC's clients, Conformity assessment of ACTIVE IMPLANTABLE MEDICAL DEVICES pursuant to Council Directive 90/385/EEC

ORACLE CONSULTING GROUP

Medical Device Training Program 2015

(OJ L 169, , p. 1)

April 3, Dear Autumn Liu,

PROPOSED DOCUMENT. Quality management system Medical devices Nonconformity Grading System for Regulatory Purposes and Information Ex-change

Medical Product Software Development and FDA Regulations Software Development Practices and FDA Compliance

Guidance on the In Vitro Diagnostic Medical Devices Directive 98/79/EC

GUIDELINES FOR IMPORT AND MANUFACTURE OF MEDICAL DEVICES

August 21, TCM Associates Ltd Mr. Iain Alligan Technical Director 3 Hillgrove Business Park Nazeing Road Essex EN9 2HB United Kingdom

Q(K SVJM~jPagelIof 3

Medical Product Development Certificate Program

An introduction to the regulation of apps and wearables as medical devices

Attributes Acceptance Sampling Understanding How it Works

The Medical Device Industry in Korea: Strategies for Market Entry

Comparative analysis between the possible regulatory approaches to GMP compliance TITOLO PRESENTAZIONE

Dental Morelli Ltda.

US & CANADA: REGULATION AND GUIDELINES ON MEDICAL SOFTWARE AND APPS OR

MEDICAL DEVICES INTERIM REGULATION

Guidance for accreditation of EN 15224:2012 Health care services Quality management systems Requirements based on EN ISO 9001:2008

Navigating the New EU Rules for Medical Device Software

FDA Review Patterns of De Novo Submissions

Med-Info. New Act on Medical Devices in Japan. TÜV SÜD Product Service GmbH. International expert information for the Medical Device industry

Regulation of Medical Devices involving Software in Australia an Overview

IAF Mandatory Document for the Application of ISO/IEC in Medical Device Quality Management Systems (ISO 13485)

Medical Device Marketing Authorization System (MDMA) MDMA User Manual

PEOPLE > SCIENCE > SOLUTIONS

Regulation of Mobile Medical Apps

Update: Proposed Medical Device Regulation (MDR) & IVD Regulation (IVDR)

May 7, Tactile Systems Technology Inc Daniel Chase V.P. Engineering & Operations 1331 Tyler St NE Minneapolis, Minnesota 55413

GE Healthcare MAR

Simpler Implant Solutions Inc Arbutus St. Vancouver, BC V6i 3Y9. haroldbergmanl~ogmail.com Telephone Fax K080115

Global Regulatory Requirements for Medical Devices

CE-Marked Product List (MDD)

IVD Regulation Overview. Requirements to Assure Quality & Effectiveness

March 31, Etiometry, Inc. Richard Galgon Independent Consulting Associate Quintiles 5846 Cobblestone Lane Waunakee, Wisconsin 53597

Med-Info. Introduction to Korean Medical Device regulations. TÜV SÜD Product Service GmbH

A GUIDE FOR THE QUALITY ASSURANCE

JUL Ms. Kendra Basler Regulatory Affairs Associate Abbott Vascular Cardiac Therapies 3200 Lakeside Drive Santa Clara, CA

IRS Issues Final Regulations Implementing the Affordable Care Act s Medical Device Excise Tax

Section 5: Quality Systems Regulation (QSR) and Good Manufacturing Practice (GMP)

March 20, Dear Mr. Chen:

AUSTRALIAN REGULATORY GUIDELINES FOR MEDICAL DEVICES

MEDICAL DEVICE REGULATIONS 2008 IEEE/PSES. Frank Eng Investigator FDA, San Jose, CA

Diagnostic Tests. Brad Spring Director, Regulatory Affairs

Clinical trials for medical devices: FDA and the IDE process

May 5, Dear Mr. Courtney:

INDEPENDANT CONSULTING FOR QUALITY AND REGULATORY AFFAIRS EXPERTS FOR MEDICAL DEVICES

August 12, Oertli Instrumente AG Ms. Karin Rohr Head of Quality Management & Regulatory Affairs Hafnerwisenstrasse 4 CH 9442 Berneck Switzerland

February 5, Dear Kristin Pabst,

510(k) SUMMARY. OPTION-vyM Urinary Catheter

Guidance for Industry and FDA Staff Tonometers - Premarket Notification [510(k)] Submissions

Phoenix Thera-Lase Systems, LLC Ms. Diane Rutherford Ken Block Consulting 1201 Richardson Drive, Suite 280 Richardson, Texas 75080

Medical Devices. IRELAND Arthur Cox

Medical Devices; Cardiovascular Devices; Classification of the Esophageal Thermal Regulation

November 20, Vascular Flow Technologies Ltd. Edwin Lindsay VP of QA/RA Prospect Business Centre, Gemini Cresent Dundee DD2 1TY United Kingdom

Med-Info. Malaysia Medical Device Regulations. TÜV SÜD Product Service GmbH. International expert information for the medical device industry

Transcription:

Medical Device Classification Dan O Leary CBA, CQA, CQE, CRE, SSBB, CIRM President Ombu Enterprises, LLC Dan@OmbuEnterprises.com www.ombuenterprises.com 603-209-0600 1

Speaker Biography Dan O Leary Dan O Leary is President of Ombu Enterprises, LLC, an education, training, and consulting company focusing on Operational Excellence using analytical skills and a systems approach to operations management. Dan has more than 30 years experience in quality, operations, and program management in regulated industries including aviation, defense, medical devices, and clinical labs. He holds a Masters Degree in Mathematics; is an ASQ certified Biomedical Auditor, Quality Auditor, Quality Engineer, Reliability Engineer, and Six Sigma Black Belt; and is certified by APICS in Resource Management. Ombu Enterprises, LLC Ombu works with small manufacturing companies, offering training and execution in Operational Excellence. Focusing on the analytic skills and systems approach of operations management, Ombu helps companies achieve efficient, effective process and regulatory compliance. 2

Outline The Concepts Of Medical Device Risk Classification in the US (FD&CA) Classification in the EU (MDD) Classification in Canada (CMDR) GHTF Guidance Summary and Conclusions Questions 3

The Concepts of Medical Device Risk 4

Factors That May Affect Risk Design Device design should incorporate the principles of inherent safety Manufacture Manufacturing processes must be well planned and under control Validated process ensure conforming output and reduce the compromise to safety 5

Factors That May Affect Risk Intended Use This is the objective intent of the manufacturer on how the device will be used. The intended use will define the scope of use, and, in particular, places where the device is not intended for use User experience, education, and training Define the anticipated user Identify the expected user s skill level Home use devices should be simple to operate Complex devices may require higher levels of training 6

Factors That May Affect Risk Device should not compromise The clinical condition of patients The safety of patients Safety or health of users Acceptable risks Risks are acceptable when weighed against patient benefits Compatible with a high level of health and safety Risk/benefit analysis X-rays are inherently dangerous X-ray machines have a benefit in diagnosis The benefit of imaging outweighs the exposure risk 7

Regulatory Controls Regulators ensure public health and safety Regulations try to match the level of control with the risk The overarching goal is appropriate control commensurate with risk! The methods to approach regulatory controls differ by geographic market Controls follow the market, not the manufacturing location Product marketed in the EU and manufactured in the US must follow EU regulations 8

Concept of Control v. Risk Control Level The risk classes and the control levels are discrete. Typically, a regulatory system will have 3 or 4 risk classes. Device Risk 9

Classification in the US 10

Devices Classes Device classes (and controls) in the US are defined by law The Food, Drug, and Cosmetic Act (FD&CA) defines the classes as: Class I, General Controls Class II, Special Controls Class III, Premarket Approval 11

General Controls The FD&CA lists the General Controls as references to sections of the law. In general, they are: Cannot be adulterated (must follow the regulations) Cannot be misbranded (must have accurate labels and labeling) The firm must register with the FDA The firm must list its devices with the FDA Cannot be a banned device (unreasonable and substantial risk of illness or injury) Not subject to recall (or similar action) The firm must maintain certain records and reports The firm must apply good manufacturing practices 12

Special Controls General controls are not sufficient, by themselves, to provide reasonable assurance of the safety and effectiveness of the device Special controls include: performance standards postmarket surveillance patient registries guidelines (including clinical data in premarket notification) other appropriate actions 13

Premarket Approval General controls and Special controls are not know to be sufficient to ensure the safety and efficacy of the device. Application for premarket approval include: Reports of investigations to show whether or not such device is safe and effective a statement of the components, ingredients, and properties and of the principle or principles of operation, of the device a description of the methods, facilities, and control for the manufacture, processing, packing, and installation of the device Reference to any relevant performance standards and the device ability to meet the performance standard Sample of the device and components Proposed labeling Certification related to clinical trials Other relevant information the FDA may require 14

The Controls For each device, the FDA determines the Class. Class I devices require general controls Class II devices require general control and special controls Class III devices require general controls, special controls, and premarket approval The are exceptions and exemptions for certain devices 15

Who Classifies Devices The law requires a recommendation from panels based on medical specialties The current panels are: Anesthesiology Cardiovascular Clinical Chemistry and Clinical Toxicology Dental Ear, Nose, and Throat Gastroenterology and Urology General and Plastic Surgery General Hospital and Personal Use Hematology and Pathology Immunology and Microbiology Neurology Obstetrical and Gynecological Ophthalmic Orthopedic Physical Medicine Radiology Ombu Enterprises, LLC Medical Device Classification 16

The Panels The panel examines the device type The panel classifies the device as I, II, or III. The panel can exempt certain parts of the regulations: Premarket notification Good manufacturing practices When accepted, the panel s recommendations are published as regulations 17

Two Dimensional Classification In the US, every device is classified along two dimensions: Each device is assigned a panel The panel determines the Class and other controls and exemptions The outcome is a regulation that specifies the class, special controls, exemptions, etc. All of the information is available on the FDA website. 18

Classification Example #1 Blood pressure cuff Regulation Description: Blood pressure cuff Definition: A blood pressure cuff is a device that has an inflatable bladder in an elastic sleeve (cuff) with a mechanism for inflating the bladder. The cuff is used to determine a subject's blood pressure. Regulation Medical Specialty: Cardiovascular Review Panel: Cardiovascular Product Code: DXQ Submission Type: 510(k) Regulation Number: 870.1120 Device Class: 2 GMP Exempt? No Recognized Consensus Standards AAMI SP10:2002 Manual, electronic or automated sphygmomanometers Guidance Document Non-Automated Sphygmomanometer (Blood Pressure Cuff) Guidance Version 1; Final Third Party Review: Eligible for Accredited Persons Program 19

Classification Example #1 (cont.) Sec. 870.1120 Blood pressure cuff. (a) Identification. A blood pressure cuff is a device that has an inflatable bladder in an inelastic sleeve (cuff) with a mechanism for inflating and deflating the bladder. The cuff is used in conjunction with another device to determine a subject's blood pressure. (b) Classification. Class II (performance standards). 20

Classification Example #2 Infant Heel Warmer Device: Infant heel warmer (chemical heat pack) Regulation Description: Hot or cold disposable pack. Regulation Medical Specialty: Physical Medicine Review Panel: Physical Medicine Product Code: MPO Submission Type: 510(k) Regulation Number: 890.5710 Device Class: 1 GMP Exempt? No Guidance Document Guidance Document for the Preparation of Premarket Notification [510(k)] Applications for Heating and Cooling Devices Third Party Review: Eligible for Accredited Persons Program 21

Classification Example #2 (cont.) Sec. 890.5710 Hot or cold disposable pack (a) Identification. A hot or cold disposable pack is a device intended for medical purposes that consists of a sealed plastic bag incorporating chemicals that, upon activation, provides hot or cold therapy for body surfaces. (b) Classification. Class I (general controls). Except when intended for use on infants, the device is exempt from the premarket notification procedures in subpart E of part 807 of this chapter subject to 890.9. Notice that the device class remains constant, but the regulatory requirements change with the intended use (adult or infant). 22

Classification Example #3 Device: Stent, coronary Definition: This device is a metal scaffold placed via a delivery catheter into the coronary artery or saphenous vein graft to maintain the lumen. Review Panel: Cardiovascular Product Code: MAF Submission Type: PMA Device Class: 3 GMP Exempt? No Recognized Consensus Standards ASTM F2079-02 Standard Test Method for Measuring Recoil of Balloon-Expandable Stents ASTM F2129-06 Standard Test Method for Conducting Cyclic Potentiodynamic Polarization Measurements to Determine the Corrosion Susceptibility of Small Implant Devices ASTM F2081-06 Standard Guide for Characterization and Presentation of the Dimensional Attributes of Vascular Stents Guidance Document Non-Clinical Tests and Recommended Labeling for Intravascular Stents and Associated Delivery Systems - Guidance for Industry and FDA Staff Third Party Review Not Third Party Eligible 23

Premarket Notification Many device types require Premarket Notification. Typically, these are Class II devices Section 510(k) of the FD&CA created this approach, so they are typically called a 510(k) 24

Substantial Equivalence One approach in the premarket notification submission (510(k)) demonstrates the device is "substantially equivalent to a legally marketed device. Substantially equivalent means: the same intended use as the predicate device the same technological characteristics as the predicate device, or has different technological characteristics but is as safe and effective as a legally marketed device, and does not raise different questions of safety and effectiveness than the predicate device 25

Basic Control General Controls Special Controls Premarket Approval Class I YES Class II YES YES Class III YES YES YES Note: Some specific devices may be exempt from the requirements shown here. Always check the regulation for the device type. 26

US Summary Three device classes (I, II, and III) Classification determined by the FDA Controls depend upon the classification For existing devices, Premarket Notification establishes a chain of predicate devices For new devices, Premarket Approval demonstrates the device is safe and effective. 27

Classification in the EU (MDD) 28

Product Directives The EU uses a system of product directives. Each directive applies to a particular kind of product. The manufacturer must determine the applicable directives. 29

Directives Related to Medical Devices The EU has three directives that apply to medical devices. Active Implantable Medical Devices are controlled by the AIMDD In Vitro Diagnostic Devices are controlled by the IVDD All other medical devices are controlled by the MDD We will discuss the MDD only 30

MDD Revisions A revision of the MDD goes into effect at the end of March 2010. Our presentation is based on the revised version. The same general principles apply to both versions. 31

The Notified Body The EU does not have a government organization equivalent to the FDA. Devices are put on the market following conformity assessment methods. Conformity assessment is risk based, using device classification, and may involve a Notified Body. A Notified Body is a private company that you, as the manufacturer, hire. Notified Bodies are accredited by organizations in the Member States. 32

Basic Definitions Notification An act whereby a Member State informs the Commission and the other Member States that a body, which fulfils the relevant requirements, has been designated to carry out conformity assessment according to a directive. Notification of Notified Bodies and their withdrawal are the responsibility of the notifying Member State. Notified Body Certification, inspection, or testing body designated by the Notifying authority of a EU Member State to perform the Attestation of Conformity of products within the scope of a New Approach Directive. 33

A Simplified Picture EU Member States (27) Accreditation Bodies Notified Bodies 34

The Relationships Member State Accreditation Body Responsible, under the treaty for the notification process Evaluates potential notified bodies on behalf of the member state Notified Body Manufacturer Performs services for a manufacturer placing a product on the market in the EU Places the product on the market Customer Purchases and uses the product 35

Modules The conformity paths are based on the concept of modules Each directive implements the appropriate methods based on the directive. 36

Module Content Module A Internal control of production B EC type-examination certificate C Conformity to type D Production quality assurance E Product quality assurance F Product verification G Unit verification H Full quality assurance Description Covers internal design and production control. Does not require a notified body to take action. Covers design, and must be followed by a production phase module. A notified body issues the EC type-examination certificate Follows module B. Provides for conformity with the type as described in the EC type examination certificate. Does not require a notified body to take action. Follows module B. A notified body approves the quality system for production, and for final product inspection and test. Follows module B. A notified body approves the quality system for final product inspection and test. Follows module B. A notified body controls conformity to type as described in the EC type examination certificate and issues a certificate of conformity. Each individual product is examined by a notified body who issues a certificate of conformity. A notified body approves the quality system for design, manufacture, and final product inspection/test. Note: The structure aligned with the, now superseded, ISO 9001, 9002, & 9003 model. 37

Module Scheme DESIGN PHASE PRODUCTION PHASE MODULE A MODULE C MODULE D Manufacturer MODULE B MODULE E CE Mark MODULE F MODULE G MODULE H 38

A Look at the MDD 39

Where to obtain the Directives The best place is the European Commission site http://ec.europa.eu Click EN (for English) Search "List of references of harmonised standards (with quotation marks and the British spelling) This site contains the directives that require CE Mark, and other useful information. The text of directive and amendments Consolidated version of directive Lists of references of harmonized standards 40

Consolidated Version The site has the following entries for the MDD Each of the entries has a hyperlink to the documents The subject hyperlinks to the Harmonized Standards list The MDD has been modified, so there is a consolidated version Text of directive and amendments 93/42/EEC 98/79/EC 2000/70/EC 2001/104/EC 2007/47/EC Consolidated version of directive 93/42/EEC Subject (short title of directive) Medical devices 41

The Device Class The manufacturer determines the device class following the rules in Annex IX Determine if the device is invasive or not An invasive device, in whole or in part, penetrates inside the body, either through a body orifice or through the surface of the body Determine if the device is active An active device depends on a source of electrical energy (or any source of power other than that directly generated by the human body or gravity) and acts by converting this energy Determine if any special rules apply When multiple rules could lead to different classification, use the highest risk class. 42

Conformity Paths The rules lead to multiple paths to demonstrate conformity The device class determines the available options Some of the options require a Notified Body 43

The Annexes Annex II EC Declaration Of Conformity The manufacturer applies the quality system approved for the design, manufacture and final inspection of the products concerned Annex III EC Type-examination A notified body ascertains and certifies that a representative sample of the production covered fulfils the relevant provisions of the Directive Annex IV EC Verification The manufacturer (or authorized representative) ensures the products conform to the type described in the EC type-examination certificate and meet the requirements of the Directive which apply to them 44

The Annexes Annex V EC Declaration Of Conformity The manufacturer ensures application of the quality system approved for the manufacture of the products concerned, carries out the final inspection, and is subject to surveillance Annex VI EC Declaration Of Conformity The manufacturer ensures application of the quality system approved for the final inspection and testing of the product and is subject to surveillance Annex VII EC Declaration Of Conformity The manufacturer (or authorized representative) prepares technical documentation. This annex has special provisions for sterile devices and devices with a measuring function 45

Class III Devices Does not apply to devices that are custom made or intended for clinical investigation Class III OR Annex II Annex III OR Annex IV Annex V CE Mark 46

Class IIa Devices Class IIa OR Does not apply to devices that are custom made or intended for clinical investigation Annex II Annex VII OR Annex IV Annex V Annex VI CE Mark 47

Class IIb Devices Class IIa OR Does not apply to devices that are custom made or intended for clinical investigation Annex II Annex III OR Annex IV Annex V Annex VI CE Mark 48

Class I Devices Does not apply to devices that are custom made or intended for clinical investigation Class I Annex VII CE Mark 49

Classification Example #1 Blood pressure cuff Invasive or non-invasive: non-invasive Doesn t channel or store fluids for eventual infusion Doesn t modify blood or other body fluids Doesn t come into contact with injured skin Not an active device No special rules apply Class I by Rule 1 50

Classification Example #2 Infant Heel Warmer Invasive or non-invasive: non-invasive Doesn t channel or store fluids for eventual infusion Doesn t modify blood or other body fluids Doesn t come into contact with injured skin Not an active device No special rules apply Class I by Rule 1 51

Classification Example #3 Coronary Stent Invasive or non-invasive: Invasive Duration: Long term (Normally intended for continuous use for more than 30 days) Implantable (intended to be totally introduced into the body by surgery) Class III by Rule 8 Point 2 (An implantable device in direct contact with the central circulatory system.) Ombu Enterprises, LLC Medical Device Classification 52

MDD Summary Four device classes (I, IIa, IIb, and III) Classification determined by the manufacturer following a rule based approach in Annex IX Controls depend upon the classification Implemented using modules to define the conformity assessment system No distinction between existing devices and new devices 53

Canadian Medical Device Regulations 54

Canadian Medical Device Regulations The regulations are available on the Health Canada website http://www.hc-sc.gc.ca/dhp-mps/md-im/indexeng.php Click on Legislation and Guidelines Follow the links to the Justice Canada website 55

Medical Device Classes Four device classes (I, II, III, or IV) Class I represents the lowest risk and Class IV represents the highest risk The classification rules are in SOR/98-282 Schedule 1 If a medical device can be classified into more than one class, the class representing the higher risk applies. 56

Schedule 1 Part 1 Non-IVDs -- Invasive devices -- Non-invasive devices -- Active devices -- Special rules Part 2 IVDs -- Use with respect to Transmissible Agents -- Other Uses -- Special Rules 57

Regulatory Requirements Class II, III, or IV devices require a license The required information for a license changes with the device class 58

Classification Example #1 Blood pressure cuff Invasive or non-invasive: non-invasive Doesn t come into contact with injured skin Not intended as a mechanical barrier Doesn t channel or store fluids for eventual infusion Doesn t modify blood or other body fluids Not an active device No special rules apply Class I by Rule 7, subrule (1) 59

Classification Example #2 Infant Heel Warmer Invasive or non-invasive: non-invasive Doesn t come into contact with injured skin Not intended as a mechanical barrier Doesn t channel or store fluids for eventual infusion Doesn t modify blood or other body fluids Not an active device No special rules apply Class I by Rule 7, subrule (1) 60

Classification Example #3 Coronary Stent Invasive or non-invasive: Invasive surgically invasive device means an invasive device that is intended to enter the body through an artificially created opening that provides access to body structures and fluids. Class III by Rule 1 Subrule (3) (A surgically invasive device normally intended to remain in the body for at least 30 consecutive days.) 61

CMDR Summary Four device classes (I, II, III, and IV) Classification determined by the manufacturer following a rule based approach in Schedule 1 Part 1 Controls depend upon the classification Implemented through different licensing requirements based on the device class No distinction between existing devices and new devices 62

Global Harmonization Task Force Guidance 63

GHTF Overview The Global Harmonization Task Force (GHTF) was conceived in 1992 in an effort to respond to the growing need for international harmonization in the regulation of medical devices. GHTF has been comprised of representatives from five founding members (European Union, United States, Canada, Australia and Japan) grouped into three geographical areas: Europe, Asia-Pacific and North America. Beginning in 2006, membership expanded to include three Liaison Body members: Asian Harmonization Working Party (AHWP), International Organization for Standardization (ISO), and International Electrotechnical Commission (IEC). 64

GHTF Guidance The GHTF web site www.ghtf.org The GHTF is organized into Study Groups SG 1 - Premarket Evaluation SG 2 - Post-Market Surveillance/Vigilance SG 3 - Quality Systems SG 4 - Auditing SG 5 - Clinical Safety/Performance SG 1 issued GHTF/SG1/N:15:2006 Principles of Medical Devices Classification 65

The Classification Structure The document recommends four classes (A, B, C, and D) Class A B C D Risk Level Low Risk Lowmoderate Risk Moderatehigh Risk High Risk Device Examples Surgical retractors / tongue depressors Hypodermic Needles / suction equipment Lung ventilator / bone fixation plate Heart valves / implantable defibrillator 66

The Classification Structure The guidance offers a rule based approaches The rules are divided into: Non-invasive Devices Invasive Devices Active Devices Additional Rules The guidance document includes decision trees that help navigate the rule structure 67

Conformity Assessment GHTF/SG1/N40:2006 Principles of Conformity Assessment for Medical Devices The each device class the document has a table that defines the activities in: Conformity assessment of the QMS Conformity assessment of device safety & performance Registration It also defines the responsibility of The manufacturer Regulatory Authority or Conformity Assessment Body 68

Classification Example #1 Blood pressure cuff Invasive or non-invasive: non-invasive Doesn t come into contact with injured skin Not intended as a mechanical barrier Doesn t channel or store fluids for eventual infusion Doesn t modify blood or other body fluids Not an active device No special rules apply Class A by Rule 4 69

Classification Example #2 Infant Heel Warmer Invasive or non-invasive: non-invasive Doesn t come into contact with injured skin Not intended as a mechanical barrier Doesn t channel or store fluids for eventual infusion Doesn t modify blood or other body fluids Not an active device No special rules apply Class A by Rule 4 70

Classification Example #3 Coronary Stent Invasive or non-invasive: Invasive Surgically invasive device: An invasive device which penetrates inside the body through the surface of the body, with the aid or in the context of a surgical operation. Long term duration: Normally intended for continuous use for more than 30 days. Class C by Rule 8 71

GHTF Summary Four device classes (A, B, C, and D) Classification determined by the manufacturer following a rule based approach supplemented with decision trees. Does not discuss controls, but refers to GHTF/SG1/N40:2006 Principles of Conformity Assessment for Medical Devices No distinction between existing devices and new devices 72

Quality Management Systems 73

QMS Requirements Region US EU Canada Required QMS 21 CFR Part 820 Quality System Regulation EN ISO 13485:2003/AC:2007 Medical devices - Quality management systems - Requirements for regulatory purposes CAN/CSA-ISO 13485:03 Medical devices - Quality management systems - Requirements for regulatory purposes 74

Summary & Conclusions 75

Summary Each region (US, EU, and Canada) has a system for classification of medical devices The device classification determines the conformity assessment scheme In the US, the FDA determines the device class using medical specialty panels In the EU and Canada, the manufacturer applies a rule based system to determine the class. The three systems are not the same, i.e., any given device could be in a different risk class in a different system 76

Summary The GHTF has an approach to standardize the classification and regulatory system. GHTF/SG1/N15:2006 Principles of Medical Devices Classification GHTF/SG1/N40:2006 Principles of Conformity Assessment for Medical Devices 77

Conclusions A manufacturer will often sell devices in multiple markets. The classification and conformity systems differ in the various markets A manufacturer must conform to systems where the device is marketed 78

QUESTIONS 79