Atlas Copco Generators



Similar documents
P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Diesel Generating Set

Magnum Mobile Generator MMG55 Specifications

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Marine Generating Sets 3.7 to 50 kva

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

The kva RAnge

Spark-ignited generator set

Power kva 17,4 18,9 Power kw 13,9 15,1 Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 0,8

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

HFW-100 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

Diesel Engine Driven Generators Page 1 of 6

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

DIESEL GENERATOR SETS

OPTIONAL FEATURES 30

Power kva Power kw Rated Speed r.p.m Standard Voltage V 240/120 Rated at power factor Cos Phi 1

Annex-A TECHNICAL SPECIFICATION

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

HYBRID POWER SYSTEMS for TELECOM applications

Phase Modular Finally the benefits of Modular ups are for all

Commercial Marine Generators

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

AUTOMATIC TRANSFER SWITCH. Changeover Type from 250A to 2500A

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

Diesel Generator Set Model DGDK 60 Hz

CUKUROVA GENERATOR SYSTEMS

CUKUROVA GENERATOR SYSTEMS

How To Use A Cat Diesel Engine

How To Control A Power Command Powerplant

Galaxy VM. Three-phase power protection. schneider-electric.com

RENTAL XQ230 SOUND ATTENUATED. DUAL VOLTAGE 50/60 Hz FEATURES

Diesel Generator Set Model DFMB 60 Hz

4.0 UPS dedicated to ICT for unmatched energy savings

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

UPS system for emergency lighting and smoke extraction

1100 Series 1104C-44TAG2 Diesel Engine ElectropaK rpm

Diesel Generator Set Model DFHC 60 Hz

Thyristor-controlled power supplies and battery chargers

Power Generation. Power Control PCL System Generator Set Control

Atlas Copco Construction Technique Service. Extended Warranty and Service Agreements The peace of mind you need to focus on your business

SD L. Industrial Diesel Generator Set. SD kw. Powering Ahead. Codes and Standards. Standby Power Rating 10 kw 12.

PI734D - Technical Data Sheet

PI734B - Technical Data Sheet

Rental. C18-20 XQ600 MULTI-VOLTAGE SOUND ATTENUATED POWER MODULE 60 Hz FEATURES

APS100 Rental Generator Set Specification

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical data. Danfoss DHP-A

Generators TEM. for small hydroelectric power stations. Electric Machines

TECHNICAL SPECIFICATIONS FOR DIESEL GENERATORS 15KVA (CANOPY TYPE)

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Atlas Copco Construction Technique Service. Extended Warranty and Service Agreements The peace of mind you need to focus in your business

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

Oil and Coolant Circulating Heating System. Model - OCSM

The Yachtmans Choice...

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

PI044E - Winding 311 APPROVED DOCUMENT. Technical Data Sheet

Stroom voor elke toepassing

Hybrid GenSet HYBRID POWER UNIT. Hybrid GenSet. POWER RANGE 7-35 kw. APPLICATIONS Outdoor Indoor Telecom Site.

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

ABB PSPS Erich Steinmann; Generator control-2013

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

POWER PORTABLE GENERATORS POWER. WHEN YOU NEED IT.

A Single Source for all Power System Solutions

REVIEWED BY CAPITAL PROJECTS MANAGER (DAN REDDY) GENERAL MANAGER EQUIPMENT ENGINEERING & ASSET MANAGEMENT (HAMILTON NXUMALO)

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

PM734F - Technical Data Sheet Winding 28

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Screw Compressors 11-22kW

Low Voltage Products

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

STANDBY 2500 ekw 3125 kva 60 Hz 1800 rpm 480 Volts

SG L. Industrial Spark-Ignited Generator Set. Powering Ahead. Codes and Standards. SG kw. Standby Power Rating 80 kw 100 kva 60 Hz

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Integrated Power Systems for Data Centers

CUKUROVA GENERATOR SYSTEMS

PI144K - Winding 311 APPROVED DOCUMENT. Technical Data Sheet. Generator Solutions AS

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

POWER GENERATION.

IGSA POWER GENERATION SYSTEMS

UNITED STATES AND U.S. TERRITORIES AND POSSESSIONS EXCEPT PUERTO RICO 2016 / WARRANTY & MAINTENANCE MANUAL

Desiccant Air Dryers Heatless, Heated and Heated Blower

Electric Flow Boiler

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

Transcription:

Atlas Copco Generators QIX 15 - QIX 540 16 kva LTP to 549 kva LTP at 50 & 60 Hz

The QIX options include Earth leakage relay Qc generating set control panels for all standby and/or paralleling applications Power cubicle including circuit breaker Fuel tank Weather protected canopy Sound attenuated canopy Super sound attenuated canopy on Industrial muffler and flexible bellow Residential muffler and flexible bellow Under frame skid Under frame spillage free skid Battery isolation switch (24V models only) Radiator stone guard protection Hot spot guards Coolant heater 220/240 V Trickle battery charger 220/240 V External fuel tank connection Electrical fuel transfer pump (from an external fuel supply) and a 4-level float switch Manual fuel transfer pump (from an external fuel supply) Low fuel level shutdown Packing crate Additional literature set Electronic governor Terminal board Lifting beam Change over contactor kits Service Paks The Qc control panel The Qc TM control panel is available in 3 variants to satisfy all your imaginable needs: Qc1001 Local/remote start panel offering: Many protections like over and under voltage protection, over and under frequency protection, engine protections, An LCD display to indicate all relevant information regarding the generator status, settings and maintenance with icons or text. Easy operating and configuration using the pushbuttons. Local manual start or remote start possibility Qc3001 Local/remote/AMF start panel offering: Next to local start and remote start also automatic mains failure (mains monitoring + automatic starting and stopping of the generator + automatic control of a panel with contactors to switch between generator and mains) Free adjustable alarms for several types of parameters. 11 different languages available to indicate information on the LCD screen Qc4001 Local/remote/AMF/paralleling start panel offering: All options of the Qc3001 TM Paralleling possible with other generators or with the mains Automatic synchronising and load sharing

QIX: peace of mind, night and day. Especially designed for industrial prime power and standby applications the Atlas Copco QIX range of diesel powered generating sets aims to be "first in mind, first in choice". By involving customers right through the QIX design process, Atlas Copco really have set the optimum balance between standardisation and customisation. Coming as standard all QIX generating sets are able to draw from the benefits of an exceptional quality, proven design; assembled using first class manufacturing techniques from carefully selected and purpose built components. But thanks to its innovative modular build concept every individual QIX generating set can be custom made to match its owner s unique requirements. Modules of options which can be easily added or removed at the factory, or indeed after the machine is in service, include several different formats of generating set enclosure, silencing and operator control interface. Every QIX generating set is designed to meet or exceed the relevant international standards including ISO8528 and is compliant with the current European Community safety and environmental regulations including OND2000/14/EC Outdoor Noise Directive. Atlas Copco is a fully accredited ISO9001 and ISO14001 company. The QIX standard package includes Rugged steel base frame Heavy-duty generator diesel engine High ambient temperature cooling package Quality brushless alternator Alternator overload capability Diesel fuel pre-filter and water separator First fill engine oil and radiator coolant / anti freeze Pre-delivery inspection and load test Comprehensive set of manuals, literature and Certificates Starting battery Manually operated oil sump drain pump Electronic governor Fork lift slots

Principal data Performance data (1) QIX Model QIX 16 QIX 22 QIX 30 QIX 44 QIX 65 QIX 85 QIX 105 Rated frequency Hz 50 50 50 50 50 50 50 Rated speed r/min 1500 1500 1500 1500 1500 1500 1500 Rated power factor (lagging) 3 phase cos phi 0.8 0.8 0.8 0.8 0.8 0.8 0.8 Rated voltage 3 phase V 400/230 400/230 400/230 400/230 400/230 400/230 400/230 Rated voltage single phase V 230 230 230 230 Rated apparent power (LTP) 3 phase kva/kw 16.7/13.3 22/17.6 30/24 44.2/35.4 65/52 91.6/73.3 107.8/86.2 Rated apparent power (PRP) 3 phase kva/kw 15/12 19.8/15.8 27/21.6 39.8/31.9 60/48 82.4/65.9 97/77.6 Rated apparent power (LTP) single phase kva/kw 13.5/13.5 17.7/17.7 24.7/24.7 31.1/31.1 Rated apparent power (PRP) single phase kva/kw 12.1/12.1 15.9/15.9 22.3/22.3 31.1/31.1 Nominal current (LTP) 400 V - 3 phase A 24 32 43 64 94 132 156 230 V - single phase A 59 77 108 135 50 Hz Rated LTP gross output kw 16.4 21.3 28.7 41.6 57.9 85 102 Deutz Engine design data Model F 3M F 3M F 4M BF 4M BF 4M BF 4M BF 4M 1011 F 1011 F 1011 F 1011 F 2012 1013 E 1013 EC Coolant Oil Oil Oil Oil Water Water Water Speed governing Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Aspiration Natural Natural Natural Turbocharged Turbocharged Turbocharged Turbocharged intercooled Number of cylinders 3 3 4 4 4 4 4 Fuel tank capacity (option) l 70 70 70 70 120 120 120 Mecc Alte Alternator design data Model ECO28-S/4 ECO28-1L/4 ECO28-VL/4 ECO32-3S/4 ECO32-2L/4 ECO34-1S/4 ECO34-2S/4 AVR sensing 1 ph 1 ph 3 ph 3 ph 3 ph 3 ph 3 ph Dimensions and weight Open frame (no muffler) LxWxH m 1.80x0.87x0.96 1.80x0.87x0.96 1.80x0.87x0.96 1.80x0.87x0.96 2.28x1.06x1.23 2.28x1.06x1.23 2.28x1.06x1.23 Weight (dry/ready to operate) kg 540/555 565/580 640/660 685/705 961/978 1131/1154 1200/1223 Weather protected canopy (no tailpipe) LxWxH m 1.80x0.87x0.96 1.80x0.87x0.96 1.80x0.87x0.96 1.80x0.87x0.96 2.28x1.06x1.71 2.28x1.06x1.71 2.28x1.06x1.71 Weight (dry/ready to operate) kg 625/640 650/665 725/745 770/790 1181/1198 1351/1374 1421/1443 Sound attenuated canopy (no tailpipe) LxWxH m 1.80x0.87x12.7 1.80x0.87x12.7 1.80x0.87x12.7 1.80x0.87x12.7 3.13x1.06x1.71 3.13x1.06x1.71 3.13x1.06x1.71 Weight (dry/ready to operate) kg 630/645 655/670 730/750 775/795 1396/1413 1566/1589 1636/1658 Super sound attenuated canopy (no tailpipe) LxWxH m 2.30x0.87x1.27 2.30x0.87x1.27 2.30x0.87x1.27 2.30x0.87x1.27 Weight (dry/ready to operate) kg 750/765 775/790 850/870 895/915 Performance data (1) QIX Model QIX 15 QIX 20 QIX 27 Rated frequency Hz 60 60 60 Rated speed r/min 1800 1800 1800 Rated power factor (lagging) 3 phase cos phi 0.8 0.8 0.8 Rated voltage 3 phase V 400/380/240 400/380/240 400/380/240 Rated voltage single phase V 240 240 240 Rated apparent power (LTP) 3 phase kva/kw 19.6/15.7 25.4/20.3 33.7/27 Rated apparent power (PRP) 3 phase kva/kw 17.6/14.1 22.9/18.3 30.3/24.3 Rated apparent power (LTP) single phase kva/kw 15.8/15.8 19.9/19.9 24.3/24.3 Rated apparent power (PRP) single phase kva/kw 14.3/14.3 18.2/ 18.2 23.2/ 23.2 Nominal current (LTP) 400 V - 3 phase A 26 30 44 240 V - single phase A 66 83 101 60 Hz Coolant Oil Oil Oil Deutz Engine design data Model F 3M F 3M F 4M 1011 F 1011 F 1011 F Rated LTP gross output kw 18.5 23.6 31.4 Speed governing Mechanical Mechanical Mechanical Aspiration Natural Natural Natural Number of cylinders 3 3 4 Fuel tank capacity (option) l 70 70 70 Mecc Alte Alternator design data Model ECO28-S/4 ECO28-1L/4 ECO28-VL/4 AVR sensing 1 ph 1 ph 3 ph Dimensions and weight Open frame (no muffler) LxWxH m 1.80x0.87x0.96 1.80x0.87x0.96 1.80x0.87x0.96 Weight (dry/ready to operate) kg 540/555 565/580 640/660 Weather protected canopy (no tailpipe) LxWxH m 1.80x0.87x1.27 1.80x0.87x1.27 1.80x0.87x1.27 Weight (dry/ready to operate) kg 625/640 650/665 725/745 Sound attenuated canopy (no tailpipe) LxWxH m 1.80x0.87x1.27 1.80x0.87x1.27 1.80x0.87x1.27 Weight (dry/ready to operate) kg 630/645 655/670 730/750 Super sound attenuated canopy (no tailpipe) LxWxH m 2.30x0.87x1.73 2.30x0.87x1.73 2.30x0.87x1.73 Weight (dry/ready to operate) kg 750/765 775/790 850/870 (1) Reference conditions Ambient barometric pressure : 100 kpa Ambient air temperature : + 25 C Power rating definitions according to ISO 8528-1 LTP / Limited Time Power : is the maximum electrical power which a generating set is capable of delivering (at variable load), in the event of a utility power failure (for up to 500 hours per year of which a maximum of 300 hours is continuous running). No overload is permitted on these ratings. The alternator is peak continuous rated (as defined in ISO8528-3) at 25 C.

QIX 140 QIX 165 QIX 220 QIX 255 QIX 330 QIX 370 QIX 405 QIX 500 QIX 540 50 50 50 50 50 50 50 50 50 1500 1500 1500 1500 1500 1500 1500 1500 1500 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 0.8 400/230 400/230 400/230 400/230 400/230 400/230 400/230 400/230 400/230 142.5/114 165.1/132.1 221.3/177.1 255.5/204.4 328.3/262.3 368.2/294.6 407.4/326 512.8/410.3 549.2/439.4 128.3/102.6 150/120 199.2/159.4 231.2/185 295.4/236.3 345.8/276.6 376.4/301.1 452/361.6 501.2/400.9 206 238 319 369 474 531 588 740 793 BF 6M BF 6M BF 6M BF 6M BF 6M BF 6M BF 6M BF 8M BF 8M 1013 E 1013 EC 1015 1015 1015 C 1015 C 1015 CP 1015 C 1015 CP 128 153 204 231 295 345 365 459 490 Water Water Water Water Water Water Water Water Water Mechanical Mechanical Electronic Electronic Electronic Electronic Electronic Electronic Electronic Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged intercooled intercooled intercooled intercooled intercooled intercooled 6 6 6 6 6 6 6 8 8 220 220 370 370 575 575 575 575 575 ECO34-2L/4 ECO34-2L/4 ECO38-2S/4 ECO38-2L/4 ECO38-3L/4 ECO38-3L /4 ECO40-1S/4 ECO40-3S/4 ECO40-3S/4 3 ph 3 ph 3 ph 3 ph 3 ph 3 ph 3 ph 3 ph 3 ph 2.73x1.06x1.49 2.73x1.06x1.49 2.97x1.37x1.61 2.97x1.37x1.61 3.25x1.69x1.99 3.25x1.69x1.99 3.25x1.69x1.99 3.25x1.69x1.99 3.25x1.69x1.99 1398/1436 1555/1595 2409/2785 2639/3015 2863/3462 2988/3507 3095/3694 3837/4272 3837/4272 2.73x1.06x1.71 2.73x1.06x1.71 2.97x1.37x2.02 2.97x1.37x2.02 3.25x1.69x2.02 3.25x1.69x2.02 3.25x1.69x2.02 3.25x1.69x2.02 3.25x1.69x2.02 1641/1679 1798/1838 2741/3117 2971/3347 3273/3872 3308/3917 3505/4104 4247/4682 4247/4682 3.59x1.06x1.71 3.59x1.06x1.71 4.17x1.37x2.02 4.17x1.37x2.02 4.84x1.69x2.02 4.84x1.69x2.02 4.84x1.69x2.02 4.84x1.69x2.02 4.84x1.69x2.02 1856/1894 2013/2053 3097/3472 3326/3702 3873/4472 3908/4517 4105/4704 4847/5282 4847/5282 QIX 40 QIX 55 QIX 75 QIX 90 QIX 115 QIX 142 60 60 60 60 60 60 1800 1800 1800 1800 1800 1800 0.8 0.8 0.8 0.8 0.8 0.8 400/380/240 400/380/240 400/380/240 400/380/240 400/380/240 400/380/240 240 - - - - - 51.1/40.8 75/60 95.8/76.7 114.5/91.6 146.8/117.5 180.1/144.1 45.9/36.8 68/54.4 86.2/69 103/82.4 132.1/105.7 162.1/129.7 32.4/32.4 - - - - - 32.4/32.4 - - - - - 67 98 126 150 193 236 135 - - - - - BF 4M BF 4M BF 4M BF 4M BF 6M BF 6M 1011 F 2012 1013 E 1013 EC 1013 E 1013 EC 46.2 66.4 84.7 101.2 126.7 153.8 Oil Water Water Water Water Water Mechanical Mechanical Mechanical Mechanical Mechanical Mechanical Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged Turbocharged intercooled intercooled 4 4 4 4 6 6 70 120 120 120 220 220 ECO32-3S/4 ECO32-2L/4 ECO34-1S/4 ECO34-2S/4 ECO34-2L/4 ECO34-2L/4 3 ph 3 ph 3 ph 3 ph 3 ph 3 ph 1.80x0.87x0.96 2.28x1.06x1.24 2.28x1.06x1.24 2.28x1.06x1.24 2.73x1.06x1.49 2.73x1.06x1.49 685/705 961/978 1131/1154 1200/1223 1398/1436 1555/1595 1.80x0.87x1.27 2.28x1.06x1.27 2.28x1.06x1.27 2.28x1.06x1.27 2.73x1.06x1.71 2.73x1.06x1.71 770/790 1181/1198 1351/1374 1421/1443 1641/1679 1798/1838 1.80x0.87x1.27 3.13x1.06x1.71 3.13x1.06x1.71 3.13x1.06x1.71 35.9x1.06x1.71 35.9x1.06x1.71 775/795 1396/1413 1566/1589 1636/1658 1856/1894 2013/2053 2.30x0.87x1.73 895/915 All engines compliant with ISO3046, ISO8528-2 & TA LUFT 4000. All alternators compliant with IEC34-1 & ISO8528-3. All alternators IP23, class H insulation of stator & rotor, 3 phases, 12 wire connections, 300% overload for 20 seconds and voltage regulation of ± 1%. Each QIX generator is factory configured at 400/230 V, 3 phase or 230 V single phase. Other voltage configurations are available upon request.

Atlas Copco QIX generators: at your service right around the world and just around the corner! Purchasing an Atlas Copco QIX generator is about more than just the machine. As standard, it also includes the full support of a company committed to the generator business, worldwide. From the outset, Atlas Copco can advise which QIX model and options best suit specific applications. Installation procedures can also be outlined. Selecting the right generator for the job has never been easier. There is more. Atlas Copco customer support is an ongoing, long term commitment. The company has two thousand trained service technicians in over 150 countries worldwide. Should a problem ever occur, access to full factory expertise is only a visit, telephone call, fax or e- mail away. Advice on correct maintenance and service procedures, plus fast genuine parts support, are all in place to minimise downtime and reduce costs. Maintenance needs of all generator models are constantly monitored so service intervals are closely matched to operating conditions. Optimum performance can be maintained to known budgets. Service kits are also available with all the replacement filters and ancillary parts included. These reduce the need to complete parts orders and ensure time expired components are replaced at each service for optimum performance. Atlas Copco replacement parts meet or exceed original specifications: genuine parts provide the longevity and reliability that end users demand. Selected high quality Atlas Copco engine oil is also available. It meets the stringent quality specifications required to enable a QIX generator to run smoothly, shift after shift, day in and day out. Oils are available in 5, 20 and 210 litre containers. Atlas Copco can also offer a choice of service contracts for the QIX generator range. Further information is available from your local supplier. Atlas Copco QIX generators, for your peace of mind, night and day. 2935 0647 30 - Subject to modifications without prior notice. Printed in Belgium. Copyright 2006, Atlas Copco Airpower n.v., Wilrijk, Belgium. Use only authorized parts. Warranty or Product Liability does not cover any damage or malfunction caused by the use of unauthorized parts. www.atlascopco.com