Lewatit MonoPlus SP 112 H is especially suitable for:



Similar documents
Lewatit MP 62 is especially suitable for:

This document contains important information and must be read in its entirety. Edition: Previous Edition: /4

C-100E Strong Acid Cation Exchange Resin (For use in water softening applications)

Dow Liquid Separations DOWEX MARATHON MSA. Ion Exchange Resin. Engineering Information

Dow Liquid Separations DOWEX MARATHON A. Ion Exchange Resin ENGINEERING INFORMATION

Ion Exchange Design Hand calculation. Brian Windsor (Purolite International Ltd)

Dow Liquid Separations DOWEX SBR-P. Ion Exchange Resin ENGINEERING INFORMATION

Ion Exchange RESIN SELECTION. Marc Slagt Technical Support Specialist DOW Water & Process Solutions

Resin Types and Production. Brian Windsor (Purolite International Ltd)

Eye On Water. New Options for Removal of Trace Contaminants see page 1. Producing Spot-Free Rinse Water for Consumer Applications see page 1

UPCORE System. Suspended Solids Removal for Countercurrent Ion Exchange Systems

How To Remove Iron From Water

DOWEX Resins as Organic Solvent Desiccants

ION EXCHANGE FOR DUMMIES. An introduction

AMBERLITE IRP69 Pharmaceutical Grade Cation Exchange Resin (Sodium Polystyrene Sulfonate USP)

2.500 Desalination and Water Purification

Well Water Iron Removal Using Quantum DMI-65 Granular Filter Media

SAFETY DATA SHEET Glen-Pak TM DNA purification cartridge (for use with disposable syringes) xx

Calcite PH Nutralizer System

Ion Exchange Softening

AMBERLITE IRP64 Pharmaceutical Grade Cation Exchange Resin (Polacrilex Resin)

Safety Data Sheet Avesta Neutralization Agent 502

EG-SAFETY DATA SHEET (91/155/EWG)

The Relationship between ph and Deionized Water

Stalosan F Safety Data Sheet 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING

MATERIAL SAFETY DATA SHEET

Issue Date: 04-Oct-2013 Revision Date: 19-Nov-2014 Version Number: Identification. 2. Hazards Identification

DOW CORNING CORPORATION Material Safety Data Sheet

1. CHEMICAL PRODUCT & COMPANY IDENTIFICATION Page: 1. Effective Date: 08/26/03 Date Printed: 06/16/04 MSD:

Culligan Exchange Tank Deionization Service

GUIDELINES FOR SELECTING RESIN ION EXCHANGE OR REVERSE OSMOSIS FOR FEED WATER DEMINERALISATION

SAFETY DATA SHEET TIDYFOAM E2 HAND CLEANER SANITIZER

DEIONIZATION IN A "NUT SHELL"

advice (show the label where possible).

Ion Exchange Resins for Metal Plating and Surface Finishing

MATERIAL SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

RESOURCE Q, 1 ml and 6 ml RESOURCE S, 1 ml and 6 ml

Fixapret NF. Technical Information

MATERIAL SAFETY DATA SHEET Product Code: 10033

Dow Liquid Separations DOWEX. Ion Exchange Resins. DOWEX ion exchange resins for HFCS deashing and polishing. Technical Manual

Removing Thallium from Industrial FGD Scrubber Water with Sorbster Adsorbent Media

SODIUM SACCHARIN E-954

PRODUCT SAFETY DATA SHEET

SAFETY DATA SHEET Enz-Extract Enzyme Carpet Extractor. 1. Product and Company Identification. 2. Hazards Identification

MATERIAL SAFETY DATA SHEET

Safety Data Sheet. SECTION 1: Identification. SECTION 2: Hazard identification

SECTION 1 - PRODUCT IDENTIFICATION

*** SAFETY DATA SHEET ***

: Water and Glycol Leak Detection Solution

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

Material Safety Data Sheet

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Material Safety Data Sheet

SAFETY DATA SHEET CLEENOL LIFT WINDOW & MIRROR CLEANER

Safety Data Sheet Aluminium profiles Apply for alloys Sapa EN AW 6060, 6063, 6005, 6005A, 6082, yellow chromated, with or without powder coating.

Nickel Free Room Temperature Seal: an innovative and ecological process

APPLIED PETROCHEMICAL RESEARCH

SAFETY DATA SHEET Perfluoro-2-methylpentane

Revision Number: Issue date: 02/14/ PRODUCT AND COMPANY IDENTIFICATION 2. HAZARDS IDENTIFICATION PICTOGRAM(S) None

SAFETY DATA SHEET According to 91/155 EC

DOW CORNING CORPORATION Material Safety Data Sheet

TABLE OF CONTENT

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

The First Step in Effluent Treatment

SHOUT TRIPLE-ACTING LAUNDRY STAIN REMOVER

SAFETY DATA SHEET Revised edition no : 5

GPS Safety Summary. Hydrogen Chloride/Hydrochloric Acid. HCl

: MR MUSCLE Window & Glass Cleaner

FEMSnap. Technical Information. Semi-Crystalline Products. User Guide for the calculation tool at TechCenter Semi-Crystalline Products

Safety Data Sheet UN-GHS (Rev.4) (2011) Update: Version: 1.3

Chapter 13. Properties of Solutions

Main Drain Opener Safety Data Sheet

Technical Data Sheet February 2014

MATERIAL SAFETY DATA SHEET. PRODUCT IDENTIFIER Carbon Dioxide, Refrigerated Liquid

Safety Data Sheet UN-GHS (Rev.4) (2011) Update: Version: 1.2

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

Material Safety Data Sheet

: Fairy Professional Original Washing Up Liquid 5L

SAFETY DATA SHEET CLEENOL LIFT SPRAY CLEANER WITH BACTERICIDE

Safety Data Sheet in accordance with regulation (EC) 1907/2006 Update: Version: 1.2 Kresto kwik-wipes [ KRESTO KWIK-WIPES ] Page 1 of 6

SAFETY DATA SHEET WINTERHALTER A81 BLUE ENZYME DRAIN CLEANER

Product Code: VLB ml cartridges. Substance Name EC No. CAS No. % by Wt Hazard Symbols n Butylacetate

To calculate the value of the boiling point constant for water. To use colligative properties to determine the molecular weight of a substance.

SAFETY DATA SHEET DALER ROWNEY 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Primer for Acrylic Paint

Product Identification Numbers , , , , , ,

EU Safety Data Sheet. Vival NF. Vival NF

HADEX Food Grade Drinking Water Disinfectant

Standardization of Potassium Permanganate solution with Standard Sodium Oxalate Solution.

Fundamental issues in subzero PEMFC startup and operation. Jeremy P. Meyers February 1, 2005 DOE Freeze Workshop

Material Safety Data Sheet POOL TIME TOTAL ALKALINITY INCREASER

Safety data sheet. 1.2 Relevant identified uses of the substance or mixture and uses advised against Use of the mixture Printing industry

1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING

SAFETY DATA SHEET CLEENOL LIFT WAX FREE POLISH

THERMA-KOOL REUSABLE COLD/HOT GEL THERAPY PACK 07/30/14

MATERIAL SAFETY DATA SHEET

Emergency Phone Numbers: P.O. Box 1950 CHEMTREC: 800/ Brewster, New York POISON CENTER: 800/ /

Transcription:

Lewatit MonoPlus SP 112 H is a strongly acidic, macroporous cation exchange resin with beads of uniform size (monodisperse) based on a styrene-divinylbenzene copolymer, in fully regenerated form (min. 99% H + ), designed for all demineralization applications. The monodisperse beads have high chemical and osmotic stability. The extremely high monodispersity (uniformity coefficient: max. 1.1) and very low fines content of max. 0.1% (< 0.315 mm) result in particularly low pressure losses compared with standard resins. Lewatit MonoPlus SP 112 H is especially suitable for:» demineralization of water for industrial steam generation operated with co-current or modern counter -current systems like e.g. Lewatit WS System, Lewatit Liftbed System or Lewatit Rinsebed System» polishing using the Lewatit Multistep System or a conventional mixed bed arrangement in combination with Lewatit MonoPlus MP 800 or Lewatit MonoPlus MP 800 OH» condensate polishing in combination with Lewatit MonoPlus MP 800 or Lewatit MonoPlus MP 800 OH Lewatit MonoPlus SP 112 H adds special features to the resin bed:» high flow rates during regeneration and loading» good utilization of the total capacity» low rinse water requirement» homogeneous throughput of regenerants, water and solutions, resulting in a homogeneous operating zone» virtually linear pressure drop gradient across the entire bed depth, allowing operation with higher bed depths» good separation of the components in mixed bed applications The special properties of this product can only be fully utilized if the technology and process used correspond to the current state-of-the -art. Further advice in this matter can be obtained from Lanxess, Business Unit Ion Exchange Resins. Previous Edition: 2011-05-12 1/4

General Description Ionic form as shipped H + Functional group sulfonic acid Matrix crosslinked polystyrene Structure macroporous Appearance beige-grey, opaque Physical and Chemical Properties metric units Uniformity Coefficient* max. 1.1 Mean bead size* mm 0.67 (+/- 0.05 ) Bulk density (+/- 5 %) g/l 740 Density approx. g/ml 1.18 Water retention wt. % 56-60 Total capacity* min. eq/l 1.6 Volume change H + --> Na + max. vol. % - 8 Stability at ph-range 0-14 Storability of the product max. months 24 Storability temperature range C -20-40 * Specification values subjected to continuous monitoring. Previous Edition: 2011-05-12 2/4

Recommended Operating Conditions* metric units Operating temperature max. C 120 Operating ph-range 0-14 Bed depth min. mm 800 Specific pressure drop (15 C) approx. kpa*h/m 2 0.8 Pressure drop max. kpa 300 Linear velocity operation max. m/h 60*** Linear velocity backwash (20 C) approx. m/h 10-12 Bed expansion (20 C, per m/h) approx. vol. % 4.5 Freeboard backwash vol. % 60 (extern / intern) Regenerant HCl Counter current regeneration Counter current regeneration level approx. g/l HCl 50 80 concentration wt. % HCl 4-6 1.5 / 3** Linear velocity regeneration approx. m/h HCl 5 10-20 Linear velocity rinsing approx. m/h 5 Co current regeneration level approx. g/l HCl 100 150 Co current regeneration concentration approx. wt. % HCl 6-10 1.5 / 3** Linear velocity regeneration approx. m/h HCl 5 10-20 Linear velocity rinsing approx. m/h 5 Rinse water requirement approx. BV 2.5 Mixed bed operation Bed depth min. mm 500 Regenerant level approx. g/l HCl 100 150 Regenerant concentration approx. wt. % HCl 4-8 2-8 * The recommended operating conditions refer to the use of the product under normal operating conditions. It is based on tests in pilot plants and data obtained from industrial applications. However, additional data are needed to calculate the resin volumes required for ion exchange units. These data are to be found in our Technical Information Sheets. ** Regeneration progressive *** 100m/h for polishing Previous Edition: 2011-05-12 3/4

Additional Information & Regulations Safety precautions Strong oxidants, e.g. nitric acid, can cause violent reactions if they come into contact with ion exchange resins. Toxicity The safety data sheet must be observed. It contains additional data on product description, transport, storage, handling, safety and ecology. Disposal In the European Community Ion exchange resins have to be disposed, according to the European waste nomenclature which can be accessed on the internet-site of the European Union. Storage It is recommended to store ion exchange resins at temperatures above the freezing point of water under roof in dry conditions without exposure to direct sunlight. If resin should become frozen, it should not be mechanically handled and left to thaw out gradually at ambient temperature. It must be completely thawed before handling or use. No attempt should be made to accelerate the thawing process. This information and our technical advice whether verbal, in writing or by way of trials are given in good faith but without warranty, and this also applies where proprietary rights of third parties are involved. Our advice does not release you from the obligation to check its validity and to test our products as to their suitability for the intended processes and uses. The application, use and processing of our products and the products manufactured by you on the basis of our technical advice are beyond our control and, therefore, entirely your own responsibility. Our products are sold in accordance with the current version of our General Conditions of Sale and Delivery. Previous Edition: 2011-05-12 4/4

Lenntech info@lenntech.com Tel. +31-152-610-900 www.lenntech.com Fax. +31-152-616-289