PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS



Similar documents
Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

ETHOS WALL MOUNTED CONDENSING BOILERS

Electric Flow Boiler

Technical data. Danfoss DHP-A

Link-Up. Solid Fuel Association Guide to Central Heating.

Domestic Hot Water Systems and Plumbing Products

Hot Water. Heat pump water heaters. Residential and Commercial R410a

Operating instructions

Gas Condensing Boilers

MAINTENANCE INSTRUCTIONS. Thermia Robust heat pump

ROTEX gas hybrid heat pump. A strong team.

Operating instructions

Domestic Hot Water Recirculation Systems Application, Selection & Installation Guide

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

INSTALLATION & TECHNICAL MANUAL

Session 2: Hot Water Supply

FLEXCON EXPANSION VESSELS. Flamco FLEXCON Flexcon. Expansion vessels FLEXCON FLEXCON M. Flamco FLEXCON V-B.

Laddomat Charging unit

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Water Volume Calculation in Hydronic Heating & Cooling Systems

Commercial Hot Water. Make a difference...

UNDERSTANDING HOT WATER SYSTEMS IN THE HOME

Rotary screw compressors kw 5,5 7, , bar MODULO

Nirvana. Cycling Refrigerated Dryers

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

UNDERSTANDING CENTRAL HEATING SYSTEMS

Sizing and Selection of Hot Water Generating Plant. Presentation by: Rob Larner & David Dutch

Range Tribune HE Solar Unvented Direct and Indirect Cylinders

FilterFlow Automatic Water Boilers. Pure Quality

High-efficient gas boiler CompactGas

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Continuous flow direct water heating for potable hot water

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

Heavy Fuel Oil supply units. The world s best selling HFO supply unit. The right choice for any conditions

Domestic Chemical Water Treatment Manufacturers Association

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Apartment and Communal Heating Solutions

ENERGY RETROFIT PROGRAM

Description of functions

Technical Data Manual Model Nos. and pricing: see Price List

Thermo Siphon Solar Systems

REFRIGERATED COMPRESSED AIR DRYERS

HOT WATER SYSTEMS CONTENTS

Blowdown vessels Meeting the requirements of HSE PM60

PLBG/GAS SAFETY Information Bulletin

EcoSoft Water Softener. General Installation Guide

industry revolves around

FTQ. Daikin Inverter Ducted Heat Pump

The heat is there let s use it! Using free environmental heat from the air with heat pump technology for central heating and domestic hot water

Solar hot water systems that give energy efficiency a whole new meaning

The NEW Greenstar i. intuitive. innovative. improved performance. installation ease

ITE. Indirect calorifier ITE - 400/500/600/750/1000. Installation, User and Service Manual. Innovation has a name.

CANNON T4 MINI / MICRO DATA CENTRE SYSTEMS

save water, save money, save the environment Monsoon domestic rainwater harvesting systems

Installers and specifiers seeking information and advice on radiator thermostats and their application will find no better source than Danfoss.

EXPANSION AUTOMATS. Flamco. Compressor and pump expansion automats, pressurisation units FLEXCON M-K FLAMCOMAT ENA.

TECHNICAL SPECIFICATION. StirLIN-1 Economy Liquid Nitrogen System

Baxi Combi 130 HE. User s Operating Instructions. Gas Fired Wall Mounted Condensing Combination Boiler

User manual. 086U6297 Rev. 9 EN

LK Electric Boiler - 4,5

Element D Services Plumbing

THE INTELLIGENT AUTOMATIC STOPCOCK

Questionnaire Pure Media Systems

O. Gas boiler. Gaz 6000 W WBN H-E-N/L-S2400. Operating instructions for the end customer (2014/07) en

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

State of the Art Energy Efficient Data Centre Air Conditioning

Operating instructions

Rain Cloud (C-21) Product Specifications

imagine SOLAR AIR CONDITIONING MADE EASY

Solar SOLARMAX ELECTRIC BOOSTED SPECIFICATIONS ALL AUSSIE GAS & ELECTRIC BOOSTED SOLAR WATER HEATERS

Condensing Boiler Efficiency

Auxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System

FILLING AND PURGING THE SYSTEM

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

ecomax Instructions for use Wall hung room sealed fan assisted condensing boilers For the user

Natural geothermal energy.

Delivering exceptional performance and Ecovalue. Ecocent

Magnum Mobile Generator MMG55 Specifications

YUTAKI S. Domestic Heating

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

HEATING, VENTILATION & AIR CONDITIONING

In-Line Air Separators

ThermoStar Refrigeration Air Dryers

MUELLER FALLING FILM CHILLERS

SF15K SF05KSS, SF10KSS

Building Services Engineering Technician

Efficiency on a large scale CFB Steam Boilers

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

When Safety Comes First. Emergency Safety Shower and Eye Wash Catalogue

ThermoSorb Desiccant Dryers

77 ILLINOIS ADMINISTRATIVE CODE, PART 890 (NEW) ILLINOIS PLUMBING CODE (02/04) SUBPART I: WATER SUPPLY AND DISTRIBUTION

Rotary Screw Compressors UP-Series 4 & 5.5 kw

Transcription:

I N S P I R E D E F F I C IEN C Y PRESSURISATION UNITS EXPANSION VESSELS ELECTRONIC FILLING DEVICE (EFD) MAXI MAXI PLUS EXPANSION VESSELS

INSPIRED EFFICIENCY Mikrofill Systems Ltd is a Midlands based British engineering company which specialises in the design and manufacture of high quality products for the coercial heating industry. Now generally accepted within the building service industry, sealed or closed heating and chiller systems eliminate inherent problems associated with conventional open vented design. Pumping over or drawing air through the vent pipe are eliminated, reduction of system corrosion and noise, greater flexibility in system design, no water evaporation and increased pressures and temperatures are just some of the advantages associated with an unvented application. The Mikrofill range of pressurisation management equipment gives the designer and installer various levels of control with models creating up to five bar pressure. Renowned for developing innovative products, the company has built its success on quality, reliability and outstanding customer service. The rapidly expanding range of products include, gas fired condensing boilers, hot water generators and pressure management equipment. The patented Mikrofill Electronic filling device (EFD) is a clear market leader and is the most advanced filling device availalbe, suitable for all applications large or small. All Mikrofill pressure management units are supplied as matched units together with a suitably sized expansion vessel. These factory tested packages usually require no site coissioning. With over 60,000 already in use, Mikrofill Pressure management systems are the products of choice throughout the coercial heating industry. This brochure has been designed to enable you to specify Mikrofill with confidence. If you require any further information see Mikrofill.com or contact our technical department. 2 Pressure Management

INTRODUCTION TO SEALED SYSTEMS PRESSURE MANAGEMENT PRODUCTS In any heating or cooling system where water is the thermal transfer fluid (Hydronic systems) there must be a method of introducing the initial charge of water, subsequent topping up as required and also a method of accoodating the volumetric expansion of the water as temperatures within the system varies. The traditional method was the use of a header tank positioned at the highest point of the system. The fill rate was controlled by gravity and an open vent into the header tank allowed for expansion, such an arrangement was described as, An open vented system. Although this system was simple and generally reliable it imposed many restrictions on system design and created problems with corrosion due to continual oxygenation of the system water, resulting in premature failure of components. It is now accepted that it is best practise to seal the hydronic system, that is to say fill the system with water, seal the system and make allowances for expansion by one of the several means available, the most popular being a suitably sized expansion vessel. The topping up of the system is managed by a pressurisation unit. Sealed systems offer freedom of design, drastically reduce corrosion within a system and allow levels of control and protection not possible with open vented systems. Mikrofill manufacture a complete range of sealed system equipment, including the Mikrofill Electronic Filling Device, a patented unit that sets new standards for the control of hydronic systems. Mikrofill Electronic Filling Device The only WRAS approved product that can fill any system from empty and continuously manage the pressure in that system. The Mikrofill requires no pumps and utilises mains pressure to fill. This patented principle is extremely reliable and consumes less electrical power than any other pressurisation product. The Pressure logic microprocessor offers many unique features and incorporates two levels of flood protection, full BMS and self diagnostics are standard features. Mikrofill Maxi Single pump pressure manager is a conventional pressurisation unit with a difference, in addition to the control features incorporated in the Pressure logic microprocessor the Maxi range also incorporates low water level alarms, pump test buttons and are factory set as standard. Mikrofill Maxi Plus Twin pump pressure manager, as the Maxi specification but with twin pumps, auto change over on pumps and pump status indication. High pressure versions are available for all Maxi models. Mikrofill Expansion vessels Including compressor controlled units. All Mikrofill Expansion vessels comply with the pressure vessel directive. In any new sealed system where the boiler output is 70kw or more it is a requirement that a pressure management system must be installed (BS6644). MIKROFILL MIKROFILL EFD, MAXI AND EXPANSION 3 Pressure Management

MIKROFILL ELECTRONIC FILLING DEVICE (EFD) MIKROFILL ELECTRONIC FILLING DEVICE (EFD) The Mikrofill EFD is a unique patented product that was invented and developed by Mikrofill and is manufactured in our factory in Worcestershire. The Mikrofill has been continuously developed over the last 14 years and is now the undisputed market leader in pressure management. Unlike pump type pressurisation systems the Mikrofill utilises the power of mains water to fill the system, whilst its patented prevention feature ensures that the mains water is protected against harmful backflow. The Mikrofill is the most complete filling and pressure management unit available. Not only can it fill any system from empty, it is also a WRAS approved fluid category 4 backflow prevention device, so no Filling loops or RPZ valves are required. The Mikrofill also offers the most precise pressure management, whilst consuming minimal electrical energy (less than 30 Watts operational, and 10 Watts at standby). The units feature the Mikrofill Pressure logic microprocessor which offers many benefits including two methods of flood protection, indication of water usage (in litres), hours run, and frequent use. The unit also includes BMS relays for high pressure alarm, low pressure alarm and a coon fault alarm, as well as an inbuilt audible sounder. The compact dimensions, ease of installation, and inherent reliability together with its other unique features combine to make the Mikrofill the pressure manager of choice amongst specifiers and installers alike. All the Mikrofill pressure management units feature full self testing and diagnostics 4 Pressure Management

MIKROFILL MAXI AND MAXI PLUS THE MIKROFILL MAXI AND MAXI PLUS RANGE OF PRESSURE MANAGEMENT UNITS The Maxi range of units represent the best of conventional pump type pressure management units where every model incorporates Pressurelogic, bronze pumps, water lters, pump test buttons and self diagnostics. The Maxi Plus range of twin pump units also include auto changeover of duty pump. The standard units are suitable for system cold ll pressures of up to 2.9 bar, whilst the HP versions can ll to 7 bar. These sophisticated units have been continuously developed over the last 15 years, and have proven extremely reliable, the integral low water level sensor protects the pumps against damage due to running dry and the robust steel case is both functional and attractive. The microprocessor is door mounted to provide protection and enables easy access to pumps and lters. The Mikro ll Maxi range shares much of its technology with the highly acclaimed Mikro ll Electronic Filling Device, ers the following bene ts, Tw, high pressure alarm, low pressure alarm and coon alarm with volt free relays. Low water levels and pump failure will activate the integral audible sounder are all standard features, whilst the LCD displays full status information. Water usage (in litres), frequency of use, hours run and full self diagnostic information is readily available. The units are supplied fully tested and matched to a suitably sized expansion vessel, ensuring that in most situations the units require no further site setting. 5 Pressure Management

MIKROFILL EXPANSION VESSELS MIKROFILL N RANGE EXPANSION VESSELS The Mikrofill N range of expansion vessels are intended for use in sealed systems, heating or chilled water and have been designed to the highest specification and meets or exceeds the requirements of 97/23/EC the CE norm for pressure vessels. The Butyl rubber diaphragm is suitable for working temperatures up to 120deg C, thereby eliminating the need for a gravity loop and reducing installation time and cost. The standard N range of Mikrofill vessels extend to 1000 litres but vessels up to 5000 litres are available to special order. The Mikrofill DE range of WRAS approved vessels are specifically designed for use with potable water and incorporate a replaceable Butyl rubber diaphragm suitable for operating at 10 bar pressure and up to 90 c. The Mikromat range of vessels have been designed for special applications where space or very close operating pressures are an issue. These compressor controlled expansion vessels can accoodate almost three times the volumetric expansion of a standard vessel thus drastically reducing the footprint of the vessel, alternatively they can very accurately control the final working pressure on systems where pressure is an issue. The Mikromat Expansion vessels are available in sizes up to 5000litres capacity When supplied as part of any Mikrofill pressure management package the vessel will be set at the correct air charge and will include a service valve which enables the vessel to be drained independently of the system if required. 6 Pressure Management

WATER A PRECIOUS RESOURCE WATER REGULATIONS People used to think about water as an infinite resource. They could use it, abuse it, pollute it and somehow it would clean itself and always be in plentiful supply. The truth is our water supplies have to be carefully managed and protected to ensure we have sufficient supply of clean, healthy, wholesome water. The Water Fittings Regulations (or Byelaws 2000 in Scotland) are national requirements for the design, installation and maintenance of plumbing systems, water fittings and water-using appliances. Their purpose is to prevent misuse, waste, undue consumption or erroneous measurement of water, and most importantly, to prevent contamination of drinking water. They replace the former Water Byelaws which each water supplier has administered for similar purposes for many years. Where water or water-using equipment is used with fluids or materials which could contaminate the wholesome water supply, there must be adequate protection to stop backflow of potentially contaminated water into other parts of the system, especially drinking water. The regulations define Fluid Risk Categories by the type of contaminants which are present and specify the appropriate type of prevention device which must be fitted to guard against backflow. At Mikrofill we are proud that the level of protection our equipment delivers has set new standards in backflow prevention. Coercial Heating and Chilled water systems are defined as fluid risk category 4 and as such any device that is permanently connected to the wholesome water supply and a heating or chilled water system must provide at a minimum that level of protection. The Mikrofill Electronic Filling Device (EFD) gives that level of protection, not only does the EFD fill entire systems from empty and manage a designed water pressure, it is the only device of its type to offer fluid risk category 4 backflow prevention built. in Mikrofill backflow prevention, protecting what is our most precious resource. 7 Pressure Management

ELECTRICAL CONNECTIONS EFD electrical data Supply: 230V 1ph 3 Amp Full load current: 1 Amp Start current: 1 Amp Fuse rating: 3 Amp BMS relays and boiler/chiller Relays: volt free contacts rated at 250VAC at 5 Amp All relays are independantly fused at 5 Amp Maxi electrical data Supply: 230V 1ph 6 Amp Full load current: 2.5 Amp Start current: 4.5 Amp Fuse rating: 6 Amp BMS relays and boiler/chiller Relays: volt free contacts rated rated at 250VAC at 5 Amp All relays are independantly fused at 5 Amp 8 Pressure Management

EXPANSION VESSEL SIZING The following factors affect the vessel selection and the appropriate values should be assigned: 1. Total height of the system 2. Flow/return temperature 3. Pressure developed by circulating pump(s) 4. Maximum allowable pressure in system as dictated by components in the system (ie radiator, boilers, heater batteries) 5. System water content Vessel Factor 8 7 6 5 4 3 2 1 30 0.01 0.012 0.014 0.015 0.019 0.023 0.03 0.045 35 0.014 0.016 0.018 0.02 0.025 0.03 0.04 0.06 40 0.018 0.02 0.023 0.027 0.032 0.04 0.054 0.08 45 0.023 0.026 0.029 0.034 0.04 0.05 0.069 0.1 Maximum System Temperature 50 0.028 0.031 0.036 0.041 0.05 0.062 0.082 0.125 55 0.033 0.037 0.042 0.05 0.06 0.074 0.10 0.15 60 0.038 0.042 0.05 0.057 0.068 0.085 0.115 0.175 65 0.044 0.05 0.057 0.066 0.079 0.10 0.133 0.20 70 0.052 0.057 0.066 0.077 0.092 0.114 0.155 0.23 75 0.058 0.064 0.074 0.085 0.105 0.13 0.17 0.26 82 0.067 0.073 0.083 0.10 0.12 0.15 0.20 0.30 85 0.072 0.082 0.091 0.108 0.13 0.16 0.22 0.325 90 0.08 0.09 0.103 0.117 0.143 0.18 0.24 0.3675 STEP ONE Calculate the cold water fill pressure The cold fill pressure must be in excess of the static head exerted by the height of the water in the system, above the pressurisation unit ie. Height of system in meters + 3* = Cold fill pressure (bar) *allow extra 3 meters to assist venting 10 NB. The cold fill pressure is also the air/nitrogen charge pressure in the expansion vessel Example: Height of system = 12m then 12 + 3 = 1.5 bar cold fill pressure and vessel charge pressure 10 STEP TWO Establish the final working pressure The final working pressure must always be below the safe working pressure of any components in the system, including the pressure relief valve. STEP THREE ESelecting the vessel factor Using graph 1 strike a line through the required final working pressure to the right hand side of the graph, read off the vessel factor at this intersection. STEP FOUR Selecting the system factor Using the vessel factor obtained from graph 1 and the maximum system temperature, select a system factor from table 1 Example: A vessel factor of 3 and a maximum temperature of 82 c will give a system factor of 0.15. Please note: for chilled water systems we recoend using 30 c as the maximum working temperature. STEP FOUR Calculating the expansion vessel size Multiplying the system water content by the system factor will result in the minimum expansion vessel size required. In most instances the actual water content of the system is impossible to ascertain and the following approximation based on kilowatt rating of the system is acceptable. Large Systems Medium Systems Small/chilled water systems 12ltrs/kW 10ltrs/kW 8ltrs/kW 9 Pressure Management

DIMENSIONS EFD MAXI & MAXI PLUS APPLICATION 10 Pressure Management

TECHNICAL DATA N RANGE EXPANSION VESSELS N Range Technical Data Model ø D H h ø F A Weight 3 bar / 120 c N 8/3 N 12/3 N 18/3 N 25/3 N 35/3 6 bar / 120 c N 50/6 N 80/6 N 100/6 N 140/6 N 200/6 N 250/6 N 300/6 N 400/6 N 500/6 N 600/6 N 800/6 N 1000/6 272 272 308 308 376 441 512 512 512 634 634 634 233 315 360 480 465 495 570 680 890 785 915 1085 1075 1295 1530 1990 2430 130 175 175 175 175 225 225 225 225 225 245 245 245 320 340 370 370 370 485 485 485 570 570 570 570 570 3/4 3/4 3/4 3/4 3/4 3/4 kg 1.9 2.6 3.5 4.6 5.4 kg 12.5 17.0 20.5 28.6 36.7 45.0 52.0 65.0 79.0 85.0 103.0 120.0 RELAX, LET MIKROFILL HANDLE THE PRESSURE At Mikrofill we believe that the process of product selection be as straight forward as possible. Pressurisation systems can be supplied as complete packages. The pressurisation unit, expansion vessel(s) and service valve* can be manufactured, tested and set to your specific system requirements, giving the peace of mind that factory matched equipment only can. *Mikrofill service valves are the convenient answer to vessel associated maintenance tasks. The all in one service valve allows lockable vessel isolation, (inline with BS6644) drain point and a union connection for quick removal and reconnection. A suitable sized valve is included for each vessel at no additional cost with every packaged unit supplied. DE RANGE DE Range Technical Data Model ø D H h A Weight 10 bar / 95 c DE 60 DE 80 DE 100 DE 200 DE 300 DE 500 409 480 480 634 634 730 840 980 1280 1485 160 152 152 144 144 133 1 1/4 1 1/4 1 1/4 kg 25.0 27.0 32.0 50.0 55.0 85.0 11 Pressure Management

Nemko MIKROFILL SYSTEMS LTD WEST COURT MERSE ROAD NORTH MOONS MOAT REDDITCH WORCESTERSHIRE B98 9HL T: +44 (0)8452 60 60 20 F: +44 (0)8452 60 60 21 E: info@mikrofill.com W: www.mikrofill.com MFS/PM1008 0087