SP 115 CLEAR EPOXY LAMINATING SYSTEM



Similar documents
Ampreg 21 Epoxy Wet Laminating System

Araldite LY 3505* / Hardeners XB 3403* / Hardener XB * / Aradur 3405*

SC2000 CEMENT BONDING PROCEDURES

Araldite CY pbw Hardener HY pbw Filler Silica flour 270 pbw

Product Data. HexPly 8552 Epoxy matrix (180 C/356 F curing matrix)

Araldite GY 6010 A Medium Viscosity, Unmodified Liquid Epoxy Resin

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Material Safety Data Sheet

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

4. Cryogenic gloves are generally designed to protect the hands from intense cold or heat.

Scotch-Weld TM. DP410 Off-White. Product Data Sheet. Product Description. Key Features Rapid cure at room temperature; cure rate may be accelerated

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Redux Film Adhesives, Foaming Films, Primers and Liquid Shims. About HEXCEL

Product Code: VLB ml cartridges. Substance Name EC No. CAS No. % by Wt Hazard Symbols n Butylacetate

SAFETY DATA SHEET. according to 1907/2006/EC, Article 31 CYTOFIXX (CYTOLOGICAL FIXATIVE)

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Two component epoxy paste adhesive

Slow Cure Thermal Conductive Adhesive 8329TCS Technical Data Sheet 8329TCS

REPAIR MANUAL MATERIALS

SAFETY DATA SHEET EVO-STIK GRIPFILL SOLVENT FREE (Irl)

CYCOM 2040 EPOXY PREPREG

Safety Data Sheet. according to Regulation (EU) No. 1907/ Sulfuric Acid 1.0 N

PRODUCT INFORMATION : ADHESIVES DELIVERING THE FUTURE OF COMPOSITE SOLUTIONS ADHESIVES. contact@gurit.com

Two component epoxy paste adhesive. Ideal for bonding GRP, SMC and dissimilar substrates

Manufacturer/supplier information. Street/postbox: P.O. Box 15408

Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II and Regulation (EC) No. 1272/2008 (CLP) - Europe. Bona Wood Floor Cleaner

Safety data sheet. DK-5900 Rudkøbing

Ingredient % content Hazard data Cross linked Sodium Polyacrylite CAS No: Non chemical fillers Zeolite 1-10

How To Test A Base Axe

Technical Data Sheet

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

GESSO PRIMER WHITE DALER ROWNEY, 2 Corporate Drive, Cranbury, New Jersey, USA

Version: 1.0 Revision Date: 06/25/2013 Print Date: 06/25/2013 POOL TIME D.E. FILTER POWDER

Advanced Materials. Marine. Selector guide

SAFETY DATA SHEET according to EC directive 91/155/EEC

3M Thermally Conductive Epoxy Adhesive TC-2810

Workshop Self Inspection Checklist WORK01

Temperature C Cure time to reach hours LSS > 1MPa minutes

Safety Data Sheet according to 1907/2006/EC, Article 31

1. IDENTIFICATION of THE SUBSTANCE/PREPARATION and COMPANY

Black epoxy paste adhesive system

Epoxy Curing Agents and Modifiers

1. Identification of the substance/preparation and of the company/undertaking. EC-No. CAS-No. Chemical name Quantity Classification

Creation Date: Revision Date: Page: 1 of 7

Safety Data Sheet Avesta Neutralization Agent 502

MATERIAL SAFETY DATA SHEET

EG-SAFETY DATA SHEET (91/155/EWG)

92699, 92708, 92732, 53825, 53810, : D-55Y Yellow UV Leak Detection Dye Concentrate

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

Thermal Adhesives Ther-O-Bond 1500

3M Scotch-Weld EPX Two-component structural adhesives and applicator guns

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

SAFETY DATA SHEET According to 91/155 EC

SOLVENT CLEANER MSDS Page 1 of 5 SAFETY DATA SHEET. (To comply with OSHA s Hazard Communication Standard 29CFR /ANSI z400.

SAFETY DATA SHEET DALER ROWNEY 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. Primer for Acrylic Paint

*** SAFETY DATA SHEET ***

CHAMELEON THERMOCHROMIC UV FLEXO INK

Double Coated Urethane Foam Tapes

PRODUCT SAFETY DATA SHEET According to 91/155 EC 1. IDENTIFICATION OF THE SUBSTANCE / PREPARATION AND OF THE COMPANY / UNDERTAKING

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

3M Scotchcast Electrical Resin 251 Two-Part, Oven-Curing, Class F, Rigid, Filled, Epoxy Liquid Resin

SAFETY DATA SHEET BOSTIK AQUAGRIP 536

HexFlow RTM6/RTM6-2. HexFlow

DOW CORNING CORPORATION Material Safety Data Sheet

Safety Data Sheet Customwood MDF

Product Bulletin INTEROX HYDROGEN PEROXIDE

SAFETY DATA SHEET according to 1907/2006/EC, Article 31

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

FM FILM ADHESIVE

Trade Name of this Product Isopropyl Rubbing Alcohol 91% USP. Corporate Compliance Team 1666 East Touhy Avenue

VERTREL XP Cleaning agent

SILASTIC 9161 RTV Silicone Elastomer

Safety data sheet. May cause slight irritation to the skin and eyes.

MATERIAL SAFETY DATA SHEET TOILET BOWL SANITIZER

LiquaCast Liquid Molding Rubber INSTRUCTIONS

Technical Data Sheet February 2014

Swallowed Do not induce vomiting give 250 ml water to drink. Seek immediate medical attention.

SAFETY DATA SHEET BLUECOL SCREENWASH

SAFETY DATA SHEET WINTERHALTER A81 BLUE ENZYME DRAIN CLEANER

Epoxy Curing Agents and Modifiers

Product Information. D8115 Matte and D8117 Semi-Gloss Clearcoat System

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 12 / 7 / 2012

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 10 / 7 / 2012

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

PRODUCT SAFETY DATA SHEET

MATERIAL SAFETY DATA SHEET Product Code: 10033

SAFETY DATA SHEET Revised edition no : 0 SDS/MSDS Date : 13 / 7 / 2012

SAFETY DATA SHEET. HEAT SINK COMPOUND Tube

TECHNICAL DATA SHEET

SAFETY DATA SHEET TYRE SHINE

UNILIC ACRYLIC EMULSION

Document Library TS Data Sheet

Acrylic Enamel Topcoat

MATERIAL SAFETY DATA SHEET OF EPOXY ESTER KU 95 1/5

Transcription:

SP 115 CLEAR EPOXY LAMINATING SYSTEM Excellent clarity Good ultra-violet resistance Rapid fibre wet-out INTRODUCTION SP 115 is a low viscosity, ultra-clear epoxy laminating system. It has been designed for the manufacture of laminates such as those used in sail and surfboards which are to remain unpainted, and where a very clear finish is required. In this way colourful embedded graphics and attractive fabric weave styles can be kept visible. The material also contains UV filters which give the product its characteristic transparent pale violet/blue colour. These filters both enhance the sharpness of graphics, and, when overcoated with a suitable UV-screening PU varnish, will reduce the tendency of clear laminates to yellow after prolonged exposure to sunlight. The product is particularly suitable for use with glass fibre reinforcements which use fibre sizings optimised for wet-out and laminate clarity, such as RE210D. SP 115 also exhibits a high degree of toughness and water resistance, enhancing the strength and damage tolerance of the thin laminates typically used in sail and surfboard manufacture. Being completely solvent and styrene-free, polystyrene foam blanks can be safely used to produce boards of the lightest possible weight. PDS-SP 115-8-0515 1

INSTRUCTIONS FOR USE WORKSHOP CONDITIONS SP 115 is optimised for use between 18-25 C / 64 F - 77 F. At lower temperatures the product thickens and may become unworkable. At higher temperatures working times will be significantly reduced. Low Relative Humidity (<70%) and dry reinforcements are essential, both for creating high clarity laminates to clearly display graphics, and for the development of a full cure. SURFACE PREPARATION Before using the product ensure that the surfaces to be laminated or coated are clean, dry and dust-free. Use only SP Fast Epoxy Solvent (SP Solvent A) for cleaning sanded laminates. Do not use solvents on polystyrene foam. When laminating, aim to use the lowest quantity of resin consistent with good fibre wet-out, and apply good consolidation techniques using a rubber squeegee. As a guide, the weight of mixed resin system per sq.m should not be greater than the weight of the fabric per sq.m. MIXING AND HANDLING SP 115 resin is combined with SP 115 hardener in the following ratio: SP 115 resin : SP 115 hardener 5:2 (by volume) 3:1 (by weight) Use graduated plastic mixing cups (available from SP) for volumes in excess of 200ml / 6.76 fl oz. For smaller volumes use plastic syringes. Do not measure out more than can be used within 10 minutes. The resin and hardener should be mixed thoroughly in the pot for at least one minute. The resin/hardener reaction generates heat (exotherm) which must be allowed to escape to prevent an uncontrollable rapid gelation in the pot. Transferring the epoxy mix to a shallow tray will help dissipate the heat of the reaction and prolong its usable life. ADDITIONAL INFORMATION OVERCOATING OR OVER-LAMINATING Further layers of SP 115 can be applied over existing SP 115 laminate if it is still tacky. However, if the SP 115 has cured past the almost tack free stage (approx., 1 1 / 2 hours at 30 C / 86 F, 2 hours at 20 C / 68 F and 3 hours at 15 C / 59 F), it has lost its ability to bond to a fresh layer of mixed resin system. In such a case, if further layers of epoxy are required the surface must be left for a minimum of 12 hours at 25 C / 77 F, or above, to become adequately hard. This period will be longer at lower temperatures. When the surface is hard enough to sand, further epoxy layers can then be applied. The surface should be first wet sanded to obtain a good key, then wiped with Gurit Fast Epoxy Solvent (SP Solvent A) to remove the dust, prior to applying the new coating or laminate layer. FLOW COATING SP 115 may be used as a cosmetic flow coat to obtain a thick, high gloss finish over the laminate. Before any finishing work or polishing with rubbing compound, leave the coating to cure for at least 48 hours, at 20-25 C / 68 F - 77 F. VACUUM BAGS These are not normally used in surfboard manufacture from a foam blank. Should the SP 115 system be used in a female mould or over a male plug, where a vacuum bag could be used, vacuum on and vacuum off times are given in Working Properties table. SAIL AND SURF BOARD CONSTRUCTION GUIDE Full details of sail and surf board construction and finishing can be found in the Board Construction Guide obtainable from Gurit. APPLICATION GUIDES Gurit produces a number of application guides to commonly performed tasks using these products. Please contact Technical services or your stockist to obtain a copy. CURE SCHEDULE Cure between 15 C - 30 C / 59 F - 86 F. The SP 115 will cure at ambient/room temperatures providing adequate properties after 14 days. A laminate cured at ambient temperatures only should be left for as long as possible before being subjected to loads in use. The Cured System Properties table shows the mechanical properties achieved after 28 days at 21 C / 69.8 F. An elevated temperature postcure (up to 50 C / 122 F) is recommended to fully stabilize the laminate for maximum properties. A postcure gives increased mechanical properties, particularly a higher heat deflection temperature, increased toughness of the finished laminate and increased colour stability. An elevated temperature postcure can be applied after an initial 24 hour cure at room temperature. Support the moulded component adequately during the post-cure as the laminate will initially soften slightly as the temperature increases. Maximum cure at elevated temperature depends on temperature and time, e.g. 16 hours at 50 C / 122 F, or longer at lower temperatures. 2 PDS-SP 115-8-0515

PROPERTIES Component Properties Resin Hardener Mix Ratio (by weight) 100 33.3 Mix Ratio (by volume) 100 40 Viscosity @ 15 C / 59 F (cp) 1869 231 Viscosity @ 20 C / 68 F (cp) 1166 173 Viscosity @ 25 C / 77 F (cp) 723 131 Viscosity @ 30 C / 86 F (cp) 451 98 Shelf Life (months) 12 24 Colour (Gardner) pale violet 3 Mixed Colour (Gardner) - - Component Dens. (g/cm 3 ) 1.163 0.969 (lb/ft 3 ) 72.60 60.49 Mixed Density (g/cm 3 ) - 1.115 (lb/ft 3 ) - 69.61 Hazard Definition Please refer to SDS Working Properties vs. Temperature Resin / Hardener 15 C / 59 F 20 C / 68 F 25 C / 77 F 30 C / 86 F Initial Mixed Viscosity (cp) 1265 856 576 384 Gel Time - 150g / 0.33lb Mix in Water (hrs:mins) - 1:00 0:35 0:21 Pot Life - 500g / 1.1lb Mix in air (hrs:mins) 0:45 0:33 0:23 0:16 Latest Vacuum Flow Time (hrs:mins) 2:50 2:10 1:45 1:25 Earliest Vacuum Off Time (hrs:mins) 4:00 3:10 2:30 2:00 Demould Time (hrs:mins) 4:40 3:40 2:50 2:10 Notes: For an explanation of test methods used see Formulated Products Technical Characteristics. All figures quoted are indicative of the properties of the product concerned. Some batch to batch variation may occur. All times are measured from when resin and hardener are first mixed together. PDS-SP 115-8-0515 3

PROPERTIES (CONT D) Cured System Properties Units Cured (28 days @ 21 C / 70 F) Cured (24 hrs @ 21 C / 70 F + 16 hours @ 50 C / 122 F) Tg DMTA (Peak Tan δ) Tg Ult - DMTA C 64.4 84.2 F 147.9 183.6 C 97.5 97.5 F 207.5 207.5 ΔH - DSC J/g 39 5 Tg1 - DMTA Est. HDT C 54.4 74.2 F 129.92 165.6 C 49 69 F 120.2 156.2 Mositure Absorption % 1.37 1.20 Cured Density g/cm3 1.161 1.16 lb/ft3 72.48 72.41 Linear Shrinkage % 1.6 1.6 Barcol Hardness 30 37 Cast Tensile Strength Cast Tensile Modulus MPa 70.3 75.9 Psi 10196 11008 GPa 3.67 3.70 Psi 532288 536639 Cast Strain to Failure % 1.9 4.7 Lam. Comp. Strength MPa 398 444 Psi 57725 64396 Laminate T.V.M. Strain % 2.1 2.0 Laminate ILSS MPa 49.9 60.2 Psi 7237 8731 ILSS Wet Retention % 76 77 Notes: For an explanation of test methods used see Formulated Products Technical Characteristics. All figures quoted are indicative of the properties of the product concerned. Some batch to batch variation may occur. All times are measured from when resin and hardener are first mixed together. 4 PDS-SP 115-8-0515

PROPERTIES (CONT D) Initial Mixed Viscosity Latest Time for Flow Under Vacuum Earliest Vacuum Off Time Theoretical Demould Time for Thin Laminates Strain to Failure Castings Tensile Properties of Castings Notes: For an explanation of test methods used see Formulated Products Technical Characteristics. All figures quoted are indicative of the properties of the product concerned. Some batch to batch variation may occur. All times are measured from when resin and hardener are first mixed together. PDS-SP 115-8-0515 5

PROPERTIES (CONT D) Compressive Strength of RE300 Glass Laminate Interlaminar Shear Strength of RE300 Glass Laminate Glass Transition Temperature 69.8 o F 69.8 o F Notes: For an explanation of test methods used see Formulated Products Technical Characteristics. All figures quoted are indicative of the properties of the product concerned. Some batch to batch variation may occur. All times are measured from when resin and hardener are first mixed together. 6 PDS-SP 115-8-0515

HEALTH AND SAFETY The following points must be considered: 1. Skin contact must be avoided by wearing protective gloves. Gurit recommends the use of disposable nitrile gloves for most applications. The use of barrier creams is not recommended, but to preserve skin condition a moisturising cream should be used after washing. APPLICABLE RISK & SAFETY PHRASES Please refer to product SDS for up to date information specific to this product. 2. Overalls or other protective clothing should be worn when mixing, laminating or sanding. Contaminated work clothes should be thoroughly cleaned before re-use. 3. Eye protection should be worn if there is a risk of resin, hardener, solvent or dust entering the eyes. If this occurs flush the eye with water for 15 minutes, holding the eyelid open, and seek medical attention. 4. Ensure adequate ventilation in work areas. Respiratory protection should be worn if there is insufficient ventilation. Solvent vapours should not be inhaled as they can cause dizziness, headaches, loss of consciousness and can have long term health effects. 5. If the skin becomes contaminated, then the area must be immediately cleansed. The use of resin-removing cleansers is recommended. To finish, wash with soap and warm water. The use of solvents on the skin to remove resins etc must be avoided. Washing should be part of routine practice: n before eating or drinking n before smoking n before using the lavatory n after finishing work 6. The inhalation of sanding dust should be avoided and if it settles on the skin then it should be washed off. After more extensive sanding operations a shower/bath and hair wash is advised. Gurit produces a separate full Safety Data Sheet for all hazardous products. Please ensure that you have the correct SDS to hand for the materials you are using before commencing work. A more detailed guide for the safe use of resin systems is also available from Gurit, and can be found at www.gurit.com PDS-SP 115-8-0515 7

TRANSPORT & STORAGE The resin and hardener should be kept in securely closed containers during transport and storage. Any accidental spillage should be soaked up with sand, sawdust, cotton waste or any other absorbent material. The area should then be washed clean (see appropriate Safety Data Sheet). Adequate long term storage conditions for both materials will result in a shelf life of one year for the resin and two years for the hardener. Storage should be in a warm dry place out of direct sunlight and protected from frost. The temperature should be between 10 C (50 F) and 25 C (77 F). Containers should be firmly closed. Hardeners, in particular, will suffer serious degradation if left exposed to air. NOTICE All advice, instruction or recommendation is given in good faith but Gurit AG (the company) only warrants that advice in writing is given with reasonable skill and care. No further duty or responsibility is accepted by the Company. All advice is given subject to the terms and conditions of sale (the Conditions) which are available on request from the Company or may be viewed at the Company s Website: http://www.gurit.com/terms-and-conditions.aspx The Company strongly recommends that Customers make test panels and conduct appropriate testing of any goods or materials supplied by the Company to ensure that they are suitable for the Customer s planned application. Such testing should include testing under conditions as close as possible to those to which the final component may be subjected. The Company specifically excludes any warranty of fitness for purpose of the goods other than as set out in writing by the Company. The Company reserves the right to change specifications and prices without notice and Customers should satisfy themselves that information relied on by the Customer is that which is currently published by the Company on its website. Any queries may be addressed to the Technical Services Department. Gurit are continuously reviewing and updating literature. Please ensure that you have the current version, by contacting Gurit Marketing Communications or your sales contact and quoting the revision number in the bottom right-hand corner of this page. E gurit@gurit.com W www.gurit.com 8 PDS-SP 115-8-0515