GentleMax Pro. Integrated Aesthetic Treatment System. Science. Results.Trust.

Similar documents
GentleYAG. Superior Results Treating Multiple Indications. Science. Results.Trust.

Performance. All You Need. All In One.

MTOne. Taking care of people, our masterpieces. The Next Generation Multi-Source Platform IPL - Laser Er:YAG - Laser DIODE.

A single device, a plethora of treatments.

Comparative Report for Aesthetic Laser / IPL Platforms Copyright MedicalSpaMD.com - All Rights Reserved Read our Terms

Revision L Candela Proprietary Sheet 1 of 5 February 2005

New Methods for Guidance of Light-Based Treatments Using Objective Melanin Measurements

Single Mode Fiber Lasers

Laser Tattoo Removal

Optimizing the Efficacy and Comfort of Laser Hair Removal Treatment

FDA Cleared for Onychomycosis *

Explaining Ellipse I 2 PL

CO 2 laser for skin resurfacing and benign skin lesions

Long-Pulsed 1064-nm Nd:YAG Laser-Assisted Hair Removal in All Skin Types

CLASS IV THERAPY LASERS

LASER HAIR REMOVAL: SCIENTIFIC PRINCIPLES AND PRACTICAL ASPECTS

SHR Pain Free Hair Free

Innovative Low Fluence-High Repetition Rate Technology for Hair Removal

Advanced Aesthetic Technology. X-Lase

DIODE PUMPED CRYSTALASER

Safe and Effective Long-Term Hair Reduction in Tanned Patients Using an 800 nm Diode Laser

TEXAS DEPARTMENT OF STATE HEALTH SERVICES. Executive Summary. Report on Regulation of Laser Hair Removal

HIGH INTENSITY LASER A REVOLUTION IN THERAPEUTIC LASER TECHNOLOGY

Treatment Guidelines

MicroScan. Excimer laser system for all types of vision corrections OPTOSYSTEMS LTD.

SENSORS. Miniature Sensors - S3Z. Advanced line of miniature Asian style of photoelectric sensors mm background suppression

Science > MultiClear. How the MultiClear works?

Measuring Laser Power and Energy Output

Quasi-Continuous Wave (CW) UV Laser Xcyte Series

Do home-use hair removal lasers & intense light devices deliver what they promise and are they safe?

Scientific Evaluation of VSP Nd:YAG Lasers for Hair Removal

Phoroptor VRx Digital Refraction System

12/7/2014. Dr.Mohammad Alshami associate professor of dermatology Sana a university Yemen

Creighton Laser Consultants. Creighton Family Medicine-Twin Creek Carlos Prendes MD Nancy Rounds CMA Joseph Stangl PAC

Samsung Portable SSD. Branded Product Marketing Team, Memory Business

LASER MARKING SYSTEMS

CURRICULUM VITAE Dr. William F. Groff La Jolla Cosmetic Surgery Centre 9850 Genesee Avenue, Suite 480 La Jolla, CA (858)

TECHNOLAS TENEO 317. UNIQUE DESIGN, EXCEPTIONAL FEATURES Simplicity is the ultimate sophistication 1. CE Marked. See better. Live better.

Treatment of Freckles and Solar Lentigines Using A Long-Pulsed Alexandrite Laser in Asian Skin : A Pilot Study

Non-Fractional Broadband Infrared Light for: Acne Scarring - Preliminary Results

Kappa 310/320/322/330/350. Cutting to length and stripping

Case reports: Nordlys short pulse SWT treatment of: Port Wine Stains & Rosacea. (Comparison with Pulsed Dye Laser)

Study of Very Long-Pulsed (100 ms) High-Powered Diode Laser for Hair Reduction on All Skin Types

MLS Laser Therapy: demonstrated scientifically.

Smoothbeam Laser Treatment of Acne Vulgaris. Emerging Applications

Fiber Optic Distributed Temperature Sensor (B-DTS)

CARINAnav SMART LASER CONTROL

Cold Air In Laser Therapy: First Experiences With A New Cooling System

LASER SURGERY. The new 940-nanometer diode laser: An effective treatment for leg venulectasia

Vascular Treatment Guidelines

There has been an explosive increase in the

A division of Dermatology Associates of Atlanta PC. Laser Skin Care - Head to Toe. Our Services

Long-pulsed Nd : YAG laser: does it give clinical benefit on the treatment of resistant telangiectasia?

Submitter Information

K ODAK D IRECTV IEW CR 850 SYSTEM

Curing Lights HALOGEN CURING LIGHTS 5.2 L.E.D. CURING LIGHTS 5.3 LIGHT GUIDES 5.5 RADIOMETERS 5.6 ACCESSORIES FOR CURING LIGHTS 5.

I-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit

Hard Clad Silica (Standard OH) Radius

SEEING THE TECHNOLOGY

Avalanche FRAC3 Nd:YAG Laser Hair Removal

Aesthetic Plus LASER TRAINING MANUAL FOR MEDICAL PROFESSIONALS. presents

22 (21.5 viewable) Smart Display, Full HD, Rockchip Quad-Core, Optical touch, Android KitKat. VSD224

LASER TREATMENT OF VASCULAR LESIONS

MS6000 Microform Scanner

LASERs for vascular lesions. Mashayekhi vahid MD Dermatology Department Emamreza Hospital Mashhad-Iran

A compact, lightweight, portable optical spectrum analyzer for DWDM system installation and maintenance.

VERSATILE AND EASY-TO-USE 3D LASER SCANNERS > >

Epidermal Protection: A Comparative Analysis of Sapphire Contact and Cryogen Spray Cooling

SLT Long Pulse Nd: YAG Laser for the Treatment of Leg Veins and Benign Vascular Lesions

Laser Spa Group s Training Registration

Use of an 800 nm High-power Diode Laser for the Treatment of Leg Vein Telangiectasia

Forget everything you know about treadmills CYBEX 770T

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

Design and Test of Fast Laser Driver Circuits

LASER SURGERY. The 800-nm diode laser in the treatment of leg veins: Assessment at 6 months

LOW COST MOTOR PROTECTION FILTERS FOR PWM DRIVE APPLICATIONS STOPS MOTOR DAMAGE

New Direct Core Monitoring Fusion Splicer TYPE-71C+

Maxi sky 600. with people in mind

Refractory Port Wine Stains (PWS): Long Pulsed Alexandrite Laser as an Option

Objective: Conclusions: Introduction

High Power Fiber Laser Technology

VariLite Treatment Guidelines

PowerLight LED Light Therapy. The FUTURE of corrective skin

Wire, cable and pipe extrusion

Control system for laser therapy of teleangiectasies

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

AM-1. AM-1 Setup Guide for the Polycom Video Conferencing Systems QUICK SETUP GUIDE

AN INTUITIVE ACTIVITY MANAGER FOR TODAY S LIFESTYLE

ADVANCED DIRECT IMAGING. by ALTIX

KIP 720 CIS SCANNING SYSTEM WITH ADVANCED KIP REAL TIME THRESHOLDING TECHNOLOGY

DIVERSITRONICS, INC. TM

Performance without compromise

femtosecond laser platform Exceptional versatility without compromise

43 Full HD Direct-lit LED Commercial Display

RVG Innovation set free.

MTS/T-BERD Platforms Very Long Range (VLR) OTDR Module

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

VERSATILE AND EASY-TO-USE 3D LASER SCANNERS > >

From: Chief of Naval Personnel To: All Ships and Stations (less Marine Corps field addressees not having Navy personnel attached)

Evaluation of the Efficacy of Tattoo-Removal Treatments with Q-Switch Laser

Transcription:

GentleMax Pro Integrated Aesthetic Treatment System Science. Results.Trust.

When it comes to offering fast and effective laser hair removal, every specification matters. The dual wavelength of the GentleMax Pro allows us to treat a wider range of patients with one device. Due to the industry s largest spot size of 18mm, tremendous fluence options and pulse width range, The GentleMax Pro gives a whole new meaning to high-speed laser hair removal. Ellen H. Frankel, M.D., Dermatologist and Medical Director at Rejuvaderm Medi Spa GentleMax Pro The Leading Multi-Wavelength System The Pro Advantage: Faster. Greater Efficacy. More Versatility. GentleMax Pro, the integrated aesthetic platform, offers more power and versatility than any other multiwavelength device. GentleMax Pro is a single consolidated system that delivers a range of treatments-all skin type hair removal, as well as pigmented and vascular lesions. The GentleMax Pro is a dual wavelength laser platform that combines the fastest and most powerful 755 nm Alexandrite laser with an equally powerful 1064 nm Nd:YAG laser. Together, they provide high performance treatment capabilities in terms of speed, efficacy, ease-of-use, outstanding performance, safety and patient satisfaction.

Enhanced Intuitive Touch Screen Redesigned to help you more easily select wavelength and optimal treatment parameters. Faster An enhanced 2 Hz repetition rate enables you to treat more patients, faster. Dual Wavelength Delivery System Single Lightweight ergonomic handpiece delivering both 755 nm and 1064 nm wavelengths for ultimate treatment convenience. Multiple Spot Sizes 6, 8, 10, 12, 15, and 18 mm spot sizes are anatomically appropriate and offer greater fluence delivery capabilities. Variable Pulse Duration From microseconds to milliseconds variable pulse durations provide improved results and safety when treating pigmented and vascular lesions on various skin types. DCD or Air Cooling It s Your Choice The cryogen-based Dynamic Cooling Device (DCD ) and the Air Cooling Compatible (ACC ) systems both protect the epidermis and save time. DCD cooling scales with fluence provide more consistent, operator independent epidermal protection. λ 2 Specialty Delivery System GentleMax Pro also offers a dual wavelength Specialty Delivery System option with 1.5 / 3 mm spots for vascular and pigmented lesions. The Ultimate Workstation GentleMax Pro combines the highest peak power 755 nm and 1064 nm lasers in a single platform with instantaneous spot size changes and unmatched clinical performance for unlimited flexibility and safety on all skin types. The GentleMax Pro is in a class by itself, providing the power and performance necessary for superior clinical outcomes.

The Technology Advanced Technology. True Power. Real Results. There may be other multiple-wavelength systems on the market, but none come close to offering the enhanced speed, efficacy and versatility of GentleMax Pro. When compared to the competition, it s easy to see the difference. Advanced User Interface Easily select the ideal settings and save treatment parameters with the improved touchscreen interface. The GentleMax Pro Guided Mode walks the user through the set-up process with a series of questions to help determine the optimal parameter settings based on individual patient criteria. Choice of Epidermal Protection With GentleMax Pro you have a choice of skin cooling options. The patented Dynamic Cooling Device (DCD ) delivers consistent bursts of protective cryogen before and after each laser pulse. The exclusive Air Cooling Compatible (ACC) handpiece directs cold air to the treatment area for improved patient comfort. Dynamic Cooling Device (DCD) Handpiece Air Cooling Compatible (ACC) Handpiece

Clinical Results Hair Removal Lentigines / Brown Spots Photos: Kathleen P. Hutton M.D. Leg Veins Photos: Jonathan Crane, D.O. Photos: Kathleen P. Hutton M.D. Photos: E. Victor Ross, M.D. Pseudofolliculitis Barbae (PFB) Facial Veins Photos: Olga Zerpa, M.D. Photos: Mitch Chasin, M.D. GentleMax Pro Indications Hair Reduction Hemangiomas Rosacea Beard Bumps (PFB) Pigmented Lesions Facial & Spider Veins Leg Veins Diffuse Redness

Count on the World Leader to Get a Multi-Wavelength System Right System Specifications Laser Type Nd:YAG Alexandrite Alexandrite Fluence Spot Size (mm) Fluence (0.25 ms to 100 ms) Wavelength 1064 nm 755 nm Repetition Up to 10 Hz Up to 10 Hz 3 40 to 400 J/cm 2 6 6 to 150 J/cm 2 Max Delivered Energy Pulse Duration Spot Sizes λ 2 Specialty Delivery System Option Spot Sizes Beam Delivery Pulse Control Dimensions 80 joules (J) 53 joules (J) 0.250-100 ms 6 mm, 8 mm, 10 mm, 12 mm, 15 mm, 18 mm 1.5 mm, 3 mm Lens-coupled optical fiber with handpiece Finger switch, foot switch 107 cm H x 46 cm W x 69 cm D (42 x 18 x 27 ) 8 6 to 100 J/cm 2 10 6 to 60 J/cm 2 12 10 to 40 J/cm 2 15 7 to 30 J/cm 2 18 6 to 20 J/cm 2 Weight Electrical 118 kg (260 lbs) 200-240 VAC, 50/60 Hz, 30A, 4600 VA single phase Nd:YAG Fluence Spot Size (mm) Fluence (0.25 ms to 100 ms) 1.5 300 to 520 J/cm 2 3 130 to 400 J/cm 2 Optional Dynamic Cooling Device Integrated controls, cryogen container and handpiece with distance gauge 6 6 to 200 J/cm 2 8 6 to 150 J/cm 2 Cryogen DCD Spray Duration HFC 134a User adjustable range: 10-100 ms 10 6 to 100 J/cm 2 12 10 to 70 J/cm 2 DCD Delay Duration User adjustable range: 3, 5, 10-100 ms DCD Post Spray Duration User adjustable range: 0-20 ms 15 7 to 44 J/cm 2 18 6 to 30 J/cm 2 Optional Air Cooling Compatible (ACC) Handpiece Available

Science. Results.Trust. Syneron and Candela are the global leaders in the aesthetic medical device marketplace. We are one company with two distinctive brands. We combine a level of innovation, expertise and customer understanding superior to that of any company in our industry. Financial stability, through our aligned resources, allows our new company to offer customers the broadest available product portfolio, the best global service organization and an expansive worldwide distribution network. Together, we are more market responsive than ever before. We know how to quickly innovate safe and effective products to meet a variety of needs and price points. We are even stronger at anticipating future market trends to help support our customers and their patients. With new breakthrough technologies currently in the pipeline, we are ideally positioned to maintain our global leadership and continue to help you grow your practice. Syneron and Candela have offices and distributors around the world. www.syneron-candela.com 2012. All rights reserved. Syneron and the Syneron logo are registered trademarks of Syneron Medical, Ltd. Candela, the Candela logo, GentleMax Pro and GentleYAG Pro are registered trademarks of Candela Corporation. GentleLase Pro, Air Cooling Compatible, ACC, Dynamic Cooling Device and DCD are trademarks of Candela Corporation and may be registered in certain jurisdictions. PB76152EN