Standardization of Potassium Permanganate solution with Standard Sodium Oxalate Solution.



Similar documents
OXIDATION-REDUCTION TITRATIONS-Permanganometry

A Volumetric Analysis (Redox Titration) of Hypochlorite in Bleach

4.0 EXPERIMENT ON DETERMINATION OF CHLORIDES

hij Teacher Resource Bank GCE Chemistry PSA10: A2 Inorganic Chemistry Carry out a redox titration

Coordination Compounds with Copper (II) Prelab (Week 2)

EXPERIMENT 10: TITRATION AND STANDARDIZATION

Syllabus OC18 Use litmus or a universal indicator to test a variety of solutions, and classify these as acidic, basic or neutral

Acetic Acid Content of Vinegar: An Acid-Base Titration E10-1

Estimation of Alcohol Content in Wine by Dichromate Oxidation followed by Redox Titration

Juice Titration. Background. Acid/Base Titration

(1) Hydrochloric acid reacts with sodium hypochlorite to form hypochlorous acid: NaOCl(aq) + HCl(aq) HOCl(aq) + NaCl(aq) hypochlorous acid

Acid Base Titrations

Simulation of the determination of lead azide content in waste water from explosives manufacture

Topic 4 National Chemistry Summary Notes. Formulae, Equations, Balancing Equations and The Mole

2. ATOMIC, MOLECULAR AND EQUIVALENT MASSES

Illinois Central College CHEMISTRY 132 Laboratory Section: solution 2-50 ml beakers KHSO 3

CHEM 105 HOUR EXAM III 28-OCT-99. = -163 kj/mole determine H f 0 for Ni(CO) 4 (g) = -260 kj/mole determine H f 0 for Cr(CO) 6 (g)

Vitamin C Content of Fruit Juice

Chemical Reactions in Water Ron Robertson

Additional Lecture: TITRATION BASICS

Lab #10 How much Acetic Acid (%) is in Vinegar?

HOW TO MAKE STANDARD SOLUTIONS FOR CHEMISTRY

ACID-BASE TITRATIONS: DETERMINATION OF CARBONATE BY TITRATION WITH HYDROCHLORIC ACID BACKGROUND

Instructions Answer all questions in the spaces provided. Do all rough work in this book. Cross through any work you do not want to be marked.

Chapter 16: Tests for ions and gases

Austin Peay State University Department of Chemistry CHEM 1021 TESTING FOR ORGANIC FUNCTIONAL GROUPS

HOMEWORK 4A. Definitions. Oxidation-Reduction Reactions. Questions

Apparatus error for each piece of equipment = 100 x margin of error quantity measured

5.0 EXPERIMENT ON DETERMINATION OF TOTAL HARDNESS

BACKGROUND INFORMATION

4 theoretical problems 2 practical problems

The Determination of Acid Content in Vinegar

To see how this data can be used, follow the titration of hydrofluoric acid against sodium hydroxide below. HF (aq) + NaOH (aq) H2O (l) + NaF (aq)

Solution a homogeneous mixture = A solvent + solute(s) Aqueous solution water is the solvent

15. Acid-Base Titration. Discover the concentration of an unknown acid solution using acid-base titration.

Saturated NaCl solution rubber tubing (2) Glass adaptor (2) thermometer adaptor heating mantle

Question Bank Electrolysis

ANALYSIS OF FOOD AND NATURAL PRODUCTS LABORATORY EXERCISE

Determination of the amount of sodium carbonate and sodium hydroxide in a mixture by titration.

GCE Chemistry PSA14: A2 Physical Chemistry Determine an equilibrium contstant

Practical Lesson No 4 TITRATIONS

Lab 25. Acid-Base Titration and Neutralization Reactions: What Is the Concentration of Acetic Acid in Each Sample of Vinegar?

Calcium Analysis by EDTA Titration

Neutralizing an Acid and a Base

Chem 1B Saddleback College Dr. White 1. Experiment 8 Titration Curve for a Monoprotic Acid

EXPERIMENT 7 Reaction Stoichiometry and Percent Yield

TITRATION OF VITAMIN C

Leaving Certificate Chemistry Student Laboratory Notebook. Suggested Answers. by Declan Kennedy and Don O Shea

Estimation of Hardness of Water by EDTA Method

Preparation of frequently used solutions

CHEMICAL REACTIONS AND REACTING MASSES AND VOLUMES

ph units constitute a scale which allows scientists to determine the acid or base content of a substance or solution. The ph 0

Lab #13: Qualitative Analysis of Cations and Anions

K + Cl - Metal M. Zinc 1.0 M M(NO

Properties of Acids and Bases

Continuous process of sodium bicarbonate production by Solvay method

Acid-Base Titrations. Setup for a Typical Titration. Titration 1

EDEXCEL INTERNATIONAL GCSE CHEMISTRY EDEXCEL CERTIFICATE IN CHEMISTRY ANSWERS SECTION C

Volumetric Analysis. Lecture 5 Experiment 9 in Beran page 109 Prelab = Page 115

Identification of Unknown Organic Compounds

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Decomposition. Composition

Titration. Lecture # 8. Titrations in Analytical Chemistry. Other Forms of Titration. End Point vs. Equivalence Point. Minimizing Titration Error

TEACHER VERSION: Micro scale How Can We Determine the Actual Percentage of H 2 O 2 in a Commercial (Drugstore) Bottle of Hydrogen Peroxide?

How to prepare standard solutions

HS 1003 Part 2 HS 1003 Heavy Metals Test

Summer 2003 CHEMISTRY 115 EXAM 3(A)

Determination of Citric Acid in Powdered Drink Mixes

Chemical Equations & Stoichiometry

Experiment 12- Classification of Matter Experiment

Summer Holidays Questions

Precipitation Titration: Determination of Chloride by the Mohr Method by Dr. Deniz Korkmaz

Chemistry 52. Reacts with active metals to produce hydrogen gas. Have a slippery, soapy feeling. React with carbonates to produce CO 2

AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved

Acid Base Titration: ph Titration Curve

Topic 18 Acids and Bases Exercises

Determination of a Chemical Formula

Chemistry 119: Experiment 7. Potentiometric Titration of Ascorbic Acid in Vitamin C Tablets

EXPERIMENT 7 Electrochemical Cells: A Discovery Exercise 1. Introduction. Discussion

Determination of Ascorbic Acid in Vitamin C Tablets by Redox and Acid/Base Titrations

General Chemistry Lab Experiment 6 Types of Chemical Reaction

REACTIONS OF SOME TRANSITION METAL IONS

Coimisiún na Scrúduithe Stáit State Examinations Commission

Dimethylglyoxime Method Method to 6.0 mg/l Ni TNTplus 856

Solutions and Dilutions

Stoichiometry Limiting Reagent Laboratory. Chemistry 118 Laboratory University of Massachusetts, Boston

Analytical Chemistry Lab Reports

Q1. A student studied the reaction between dilute hydrochloric acid and an excess of calcium carbonate.

EXPERIMENT 8: Activity Series (Single Displacement Reactions)

Aqueous Solutions. Water is the dissolving medium, or solvent. Some Properties of Water. A Solute. Types of Chemical Reactions.

IB Chemistry. DP Chemistry Review

Petri Dish Electrolysis Electrolysis Reactions

EXPERIMENT 2 THE HYDROLYSIS OF t-butyl CHLORIDE. PURPOSE: To verify a proposed mechanism for the hydrolysis of t-butyl Chloride.

GCSE Further Additional Science. Higher Tier. Unit 2 Chemistry 3H SPECIMEN MARK SCHEME V1

Dissolving of sodium hydroxide generates heat. Take care in handling the dilution container.

STANDARDIZATION OF A SODIUM HYDROXIDE SOLUTION EXPERIMENT 14

Experiment 7: Titration of an Antacid

Chem101: General Chemistry Lecture 9 Acids and Bases

Experiment 8 - Double Displacement Reactions

Measuring volume of gas produced Measuring precipitation (because sulphur is produced) e.g. look for X to disappear Measure mass lost

Transcription:

Experiment Number: 07 Name of the experiment: Standardization of Potassium Permanganate solution with Standard Sodium Oxalate Solution. Course: Chem-114 Name: Noor Nashid Islam Roll: 0105044 Group: A2 Partner s Roll: 0105053 Department: C.S.E. Date of Performance: 14-08-2002 Date of Submission: 21-08-2002

Objective: The objective of this experiment is to determine the strength of Potassium Permanganate with a standard Sodium Oxalate solution. This reaction helps to study about oxidation and reduction theory. As, the color of potassium permanganate changes with the reaction, no further indicator is used in this experiment to determine the end point. Theory: In this experiment, potassium permanganate solution is standardized with the help of standard sodium oxalate solution. The reaction that occurs here is oxidation and reduction reaction. An oxidation-reduction reaction (red ox) is a reaction in which electrons are transferred between species or in which atoms change oxidation numbers. Oxidation is the half reaction in which there is loss of electrons by a species (or increase of oxidation number of an atom). Reduction is the half reaction in which there is a gain of electrons by a species (or decrease of oxidation number of an atom). Reaction involved in this reaction is: MnO4 - + 8 H + + 5 e - Mn +2 + 4 H 2 O 2 KMnO 4 + 5 Na 2 C 2 O 4 + 8 H 2 SO 4 K 2 SO 4 + 2 MnSO 4 + 5 Na 2 SO 4 + 10 CO 2 + 8

H 2 O In this reaction, MnO - 4 is reduced to Mn +2 and Na 2 C 2 O 4 is oxidized to CO 2. The following equation is used to calculate the strength of Potassium Permanganate: V A x S A = V B x S B Here, V A = Volume of Potassium Permanganate S A = Strength of Potassium Permanganate V B = Volume of Sodium Oxalate S B = Strength of Sodium Oxalate INDICATOR AND WHY USED: The direct reaction is slow as one can see in a titration. The first few drops of permanganate added to the acidified oxalate solution are not decolorized immediately. Mn +2 ions produced in the reaction acts as a catalyst. They react with permanganate to form intermediate oxidation states of manganese. These states, in turn, react rapidly with oxalate to give the products. So KMnO 4 acts as an auto catalyst in this reaction. This is the advantage of KMnO 4 is that it serves as its own indicator, the pink colour being distinguishable even if the solution is very dilute. Therefore no indicator is

used in this reaction. Apparatus: 1. Conical flask 2. Burette 3. Pipette 4. Volumetric flask 5. Stand 6. Funnel Name of the chemicals used: 1. Sodium Oxalate Solution (Na 2 C 2 O 4 ) 2. H 2 SO 4 solution (2N) 3. Potassium Permanganate Solution (KMnO 4 ) 4. Distilled water Data: TABLE: 1 (Standardization of Potassium Permanganate solution with Standard Sodium Oxalate solution) Burette

reading Initial Readi ng Final Readi ng ml ml 01 10 1.0 11.7 10.7 02 10 11.7 22.4 10.7 03(No t taken) 10 22.4 33.3 10.9 04 10 33.3 44.0 10.7 Calculation: In this case weight taken=0.739 Weight to be taken =0.6701 So the strength of Na2C2O4 = (0.739X0.1)/0.6701 N

=0.11 N From V red X S red = Vox X S ox Here, V Na2C2O4 = 10 ml S Na2C2O4 = 0.11 N V KMnO4 = 10.7 ml S KMnO4 =? So, 10 X 0.11 = 10.7 X S KMnO4 => S KMnO4 = 0.103N Result: The Determined Strength of Potassium Permanganate Solution is: SKMnO4 = 0.103 N Percentage of error:

( Known Value Observed Value ) X 100 Percentage of error = Known value Known value = 0.105 N Observed amount of iron = 0.103 N Percentage of error = 1.9% Precautions: At first the burette was cleaned with distilled water carefully; then it was rinsed with rinse solution to avoid the density change of the given solution. In the same way the pipette was also washed with distilled water and rinsed with the rinse solution. All the apparatus were handled carefully and according to the rules. The pipette was kept on a clean sheet of paper. The key of the burette was operated carefully to make sure that one-drop of Acid falls into the conical flask at a time. The conical flask was kept on a white paper

to trace the color change of the solution. At first the key of the burette was fully opened to let the solution fall free to make the bubbles go out. On the basis of the result it was found that the balance is very much sensitive. So for this reason the result can be varied. While measuring the lower meniscus of the burette an error may be happened for the parallax error. So concentration should be needed here. Discussion: As KMnO 4 is not a primary standard substance so determination of the strength of it will be erroneous. Many factors are responsible for this error. These are stated below: i The solution must be strongly acidic in order to avoid other side reactions. Here sulphuric acid is normally used. Nitric acid is unsuitable since nitrate ion is a moderately strong oxidizing agent which may interfere with KMnO 4. If HCl

is used it may be oxidized to chlorine by permanganate. If chloride ion is present, high results are obtained because some permanganate is used up in oxidizing the HCl to eliminate the interference of chloride ions. The main reason for using acid in the titration is that it transforms oxalate to oxalic acid and this acid solution reduces the KMnO 4. Any side reaction may hamper the result. So only sulphuric acid should be used. -1 2 MnO 4 + 16 H +1 + 10 Cl -1 2 Mn +2 + 5 Cl 2 + 8 H 2 O ii Reading might be wrong due to poor eye sight and non-vertical readings. The readings must be taken vertically considering the lower meniscus of the concave surface of the liquid. iii If any air bubble enters the burette while pouring acid, air bubble should be removed by dropping out the solution forcibly until the air bubble is out of the burette. Or else, the presence of air bubble will hamper the reading of the volume.

iv While performing the experiment we should be careful so that misuse of solution can not happen. While taking KMnO 4 solution from the burette, one or two drops might fall on the body surface of the conical flask and might stick on it. These drops would not participate in the reaction but we might count these drops in out reading from the burette. v After pouring any substance in the conical flask with the help of the pipette, if there is any liquid at the tip of the pipette, it should be ignored. But by no means it should be blown out. vi Burette and pipette was first washed with distilled water then those were rinsed. It was necessary to perform to get accurate result. viiduring our experiment the burette was leaking, and as it was not noticed earlier so error might have occurred. When it came to our consideration, we did necessary things to tight it. At first for our callousness, the result might have deceived us.

viiiin the KMnO 4 solution, there remains some impurities mainly MnO 2. Some Mn +2 are produced from MnO 2 which reacts with KMnO 4 and forms more MnO 2. This is known as auto decomposition. This will manipulate the result. 2 MnO 4-1 + 2 H 2 O + 3 Mn +2 5 MnO 2 + 4 H + ix) Even in the distilled water there remains some reducing agent which reacts with MnO 2 and produces more MnO 2 and more auto decomposition occurs. This is also responsible for erroneous result. To safeguard this re-distilled water from alkaline permanganate should be used. 4 MnO 4-1 + 2 H 2 O (containing reducing agent) 4 MnO 2 + 3 O 2 + 4OH -1 x) Even in the distilled water there remain some reducing agents which react with MnO 2 and produce more MnO 2 and more auto decomposition occurs. This is also responsible for erroneous result. 4 MnO 4-1 + 2 H 2 O (containing reducing agent) 4 MnO 2 + 3 O 2 + 4OH -1

XI) Permanganate solution should be added moderately and at the same time it has to be stirred to clear the solution constantly. But nonreactor permanganate should no way be allowed to accumulate in the solution because this may result in auto decomposition which will definitely manipulate the result. Reference books: 1) A Text Book of Quantitative analysis. A.L.Vogel 2) Practical Chemistry Huq and Jabber Main