Integrated Building Automation Solutions for Specialist Engineers
5 6 6 4 4 1 2 6 1 Enabling a completely new way of planning Implementing building functions in software. Multiple planning tasks Beckhoff reduces complexity. VDI 814 Part 1:2005-05 BACS Funktion List I/O functions Processing functions M Physical Shared ), 9) Monitoring Interlocks Closed loop control Calculation/Optimization Specialist engineers have numerous responsibilities when it comes to implementing controls in residential and functional buildings. At the interface between the building requirements and the wishes of the building owner, these engineers bear responsibility for the functionality, identification and specification of the systems, and for ensuring compliance with regulations and standards in addition to assuming cost accountability. PC-based Building Automation integrates all building systems into one control platform and reduces the complexity of building automation significantly. Row No. Binary output switching/positioning1) Analog output positioning Binary input state Plant 12- VER_A00_01E_AC01_PreHtr_Vlv Pre heater valve BACS 7- VER_A00_01E_AC01_PreHtr_Fp function list according to VDI 814 Binary input counting Analog input 2) Binary value (output), switching Analog value (output), positioning/setpt. Binary value (input), state Accumulated/totalized value (input) Analog value (input), measuring Fixed limit Sliding/Floating limit Run time totalization Event counting Command execution check State processing 4) Plant control Motor control Switchover 5) Step control 5) Safety/Frost protection control P control loop PI/PID control loop Sliding/Floating/Curve setpoint Proportional output stage Proportional to on/off conversion 6) Proportional to pulse width modulation Setpoint/Output limitation Switchover of parameters h,x directed control 7) Arithmetic calculation 7) Event switching Time schedule Optimum start/stop Duty cycling Night cooling Room temperature limitation Energy recovery 7) Backup power operation Mains power recovery pogram Peak load limitation Energy tariff dependent switching Input/output/value object types 9) Data point Section no. 1 2 4 5 6 Point name or designation Column no. 1 2 4 5 1 2 4 5 1 2 4 5 6 1 2 4 5 1 2 4 5 6 7 8 1 2 4 5 6 7 8 9 10 11 12 1 1 1 1- VER_A00_01E_AC01 Plant controller 1 1 1 1 1 2 2- VER_A00_01E_AC01_MSwNPowSupl 2 1 1 1 Cabinet switch -VER_A00_01E_AC01_OuA_Dmp 5 1 2 1 Outside air damper 4- VER_A00_01E_AC01_ExhA_Dmp Exhaust 6 1 2 1 air damper 7 5- VER_A00_01E_AC01_OuA_T 1 2 Outside air temperature 9 6- VER_A00_01E_AC01_OuAFilt_Pd 1 1 1 Outside air filter differential pressure 11 8- VER_A00_01E_AC01_ERcv_Pu 1 2 1 1 1 1 1 1 4 Energy recovery pump 12 9- VER_A00_01E_AC01_ERcv_Vlv 1 1 1 2 Energy recovery valve 1 10- VER_A00_01E_AC01_ExtAT Extract 1 2 air temperature 11- VER_A00_01E_AC01_PreHtr_Pu Pre 15 1 2 1 1 1 1 1 1 4 heater pump 16 1 1 1 2 17 1 1 1 1 Pre heater freeze protection thermostat 14- VER_A00_01E_AC01_PreHtr_T Pre 18 1 2 heater freeze protection sensor 19 15- VER_A00_01E_AC01_Col_Pu Cooler 1 2 1 1 1 1 1 1 4 pump 20 16- VER_A00_01E_AC01_ Col_Vlv 1 1 1 2 Cooler valve 17- VER_A00_01E_AC01_SpA_Fan_Pd Supply air fan differential pressure switch Implementing 18- VER_A00_01E_AC01_SpA_Fan_MntnSwi all functions in software Supply air fan maintenance switch 19- VER_A00_01E_AC01_SpA_Fan Supply air fan Building 20- VER_A00_01E_AC01_ExtA_Fan_Pd Automation from Beckhoff. 21 1 1 1 22 1 1 2 1 2 1 1 1 1 4 24 1 1 1 Extract air fan differental pressure switch 25 21- VER_A00_01E_AC01_ExtA_MntnSwi 1 1 Extract air fan maintenance switch 26 22- VER_A00_01E_AC01_ExtA_Fan 1 2 1 1 1 1 4 Extract air fan 2- VER_A00_01E_AC01_SpA_T Supply air temperature Building Automation from Beckhoff enables Issue date 14.0.2012 Author Approved Company: Project: maximum Rev. 2 planning freedom. Implementing all Rev. functions in software and decoupling functions from hardware increases planning security 27 1 2 14 Rev. 1 BECKHOFF Automation BECKHOFF Automation HQ Building A VER_A00_01E Control diagram no.: 1.2 Interlocks description: 9 Location of controls (ME 2 We reserve the right to make technical changes.
significantly, since product compatibility issues no longer arise. Even if the building project changes, the planning process does not. Software-based control not only makes it easier to handle follow-up requirements, modifications and solutions to problems above all it makes system integration more cost-effective. One control platform for all building systems Planning was never so easy. The PC-based control platform from Beckhoff allows integrated automation of all building systems in functional buildings and infrastructures from single-room control to window control to shading, lighting, HVAC MCI, smoke and heat removal systems, access control, energy monitoring and process visualisation. A single control system means four-fold simplification for engineers: planning, interdisciplinary thinking, time management and responsible cost control. Open control technology Enables alternative usage scenarios. The Beckhoff principle of an open and highlyscalable control architecture enables interoperability with standard products for integrated planning that provides a wealth of freedom for current and future building usage scenarios. All elements can be expanded, independently of products, brands and integrators, with only marginal additional costs. Beckhoff Building Automation provides engineers with the certainty that projects created and executed today will also be viable in the future, since modifications to the building control system can be implemented primarily in software. Building Automation from Beckhoff at a glance: Integration of all building systems in one platform Replacing hardware with software functions enhances flexibility Interoperability with standard products Direct integration of all fieldbus systems and protocols Maximum freedom in designing Independence in terms of product/device manufacturer/integrator Faster and more efficient planning Increased planning security Long-term availability Automated documentation We reserve the right to make technical changes.
Practical experience is key: Selected references. Tower 185, Frankfurt a. M., Germany Tower 185 is one of the four tallest skyscrapers in Germany, extending over 50 floors with floor space of approximately 100,000 m². Full HVAC management and room automation are implemented with a Beckhoff automation platform and operated by means of a shared building management system. This allows flexible room usage, definition of different utilisation scenarios, simplified controlling and benchmarking, as well as efficient maintenance management for all building systems. The control architecture for processing the 60,000 data points is based on 170 CX9010 Embedded PCs, 500 CX9001 devices, as well as 80 C6925 Industrial PCs. 4 We reserve the right to make technical changes.
Zukunftsmeile Future Mile research and development cluster, Paderborn, Germany The building automation solution in the,200 m² Building 1 of the Zukunftsmeile not only includes the HVAC system, but also encompasses full lighting control, integration of MCI technology, energy data acquisition, control of the blinds and the central locking system, as well as multimedia technology. The lighting can be adjusted to suit the varying needs of the respective tenants or different space requirements through DALI-compliant lighting control. A simple software modifi - cation is all that is needed if, for example, rooms are to be combined to form one large space or divided to form individual spaces. The global solution: Building Automation from Beckhoff Office and residential buildings, hotels and museums, shopping centres and industrial building complexes, rail stations, and theatres all around the globe use holistic and scalable building automation solutions from Beckhoff: Centre for Virtual Engineering, Fraunhofer IAO, Stuttgart, Germany Miele Administration Building, Germany Microsoft Technology Centre, Germany KölnTriangle, Cologne, Germany Park Hotel Vitznau, Switzerland Dolder Grand Hotel, Zurich, Switzerland Dresden City Museum, Germany Schauspielhaus Nürnberg, Germany Ferry Porsche Museum, Austria Zayed University, Abu Dhabi, UAE Basler Nordtangente, Basel, Switzerland We reserve the right to make technical changes. 5
Integrated PC-based Building Automation One control platform for all building systems. Embedded PC Scalable control technology Bus Terminals The complete I/O system The intelligent modular system simplifies planning requirements in buildings. The PC-based control philosophy from Beckhoff offers you a new type of planning. With a single control platform for all building systems and a modular range of software and hardware components, your project can be implemented more easily and faster while providing planning security in every phase from engineering through to unplanned changes or enhancements. The Beckhoff portfolio offers you a wealth of freedom. Powerful Industrial PCs from building management to field level, a comprehensive I/O system with more than 400 terminals for all conventional data points, as well as the engineering software TwinCAT Building Automation, with its extensive libraries and tried and tested software templates, assures maximum flexibility, custom-fit scalability and reliable functional integrity. For maximum planning freedom All functionalities provided as software modules. Beckhoff facilitates modular and holistic planning of all automation tasks with TwinCAT Building Automation software. This powerful solution provides all functionalities as software modules. This simplifies interdisciplinary thinking, reduces planning complexity and ensures simple expandability. 6 We reserve the right to make technical changes.
TwinCAT One software platform for engineering and automation Lot-size 1 planning for smart buildings With the extendable Room Box. With the extendable Room Box, Beckhoff further minimises planning effort. Apart from configuring the PLC, TwinCAT Building Automation also provides the Box Configurator to enable automated configuration of customised hardware assemblies, which can then be fully prefabricated and easily integrated. As simple as the planning Operation via multi-touch panels. Beckhoff uses TwinCAT to integrate HMI engineering conveniently into the Visual Studio integrated development environment (IDE), ensuring uniform user interfaces. At the same time, the broad multi-touch panel portfolio offers unlimited scope for individual operating concepts and a powerful frontend for building systems. Beckhoff at a glance: As a specialist for PC-based control systems, Beckhoff is renowned for universal automation solutions that are used in industrial, energy management and building automation applications worldwide, and help users maximise savings potentials, even exceeding the highest energy efficiency standards. Facts and figures: Owner-managed, medium-sized company Corporate headquarters: Verl, Germany Innovation leader in PC-based control Sales 2014: 510 Mio. Euro More than 2,900 employees worldwide 4 subsidiary companies Represented in more than 75 countries worldwide We reserve the right to make technical changes. 7
DK722-016 Building Automation for Specialist Engineers: See all information at www.beckhoff.com/building Beckhoff Automation GmbH & Co. KG Huelshorstweg 20 415 Verl Germany Phone: + 49 5246 96-0 BuildingAutomation@beckhoff.com www.beckhoff.com/building Beckhoff, TwinCAT, EtherCAT, EtherCAT P, Safety over EtherCAT, TwinSAFE, XFC and XTS are registered trademarks of and licensed by Beckhoff Automation GmbH. Other designations used in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owners. Beckhoff Automation GmbH & Co. KG 0/2016 The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual application do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressively agreed in the terms of contract.