Selecting TEMA Type Heat Exchangers



Similar documents
TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

5.2. Vaporizers - Types and Usage

Corrugated Tubular Heat Exchangers

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Examples for Heat Exchanger Design

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

Thermal design of shell-and-tube

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

Module #1 1. PROCESS DESIGN OF SHELL AND TUBE EXCHANGER FOR SINGLE PHASE HEAT TRANSFER

HEAT EXCHANGERS. Prepared by Bob Heaslip KESCO

Originators of the Flexible Water Tube design

Optimize Thermal & Mechanical Design for Shell & Tube Heat Exchangers

Heat Exchangers. Plate-and-Frame COMPACT HEAT EXCHANGERS PART 1: heat exchangers. Use these design charts for preliminary sizing.

This will also provide you with the knowledge to insure long life for your Investment

V47 Series Temperature Actuated Modulating Water Valves

DESIGN AND APPLICATION OF HAIRPIN HEAT EXCHANGERS

Stilling Well Recommendations

Float and Thermostatic Traps Series H, C and X

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

James M. Pleasants Company

TABLE OF CONTENT

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

ASME B31.3 Process Piping. Scope of B31.3 Course

Vapor Chambers. Figure 1: Example of vapor chamber. Benefits of Using Vapor Chambers

Steam System Best Practices Condensate System Piping

Sondex Welded heat exchangers:

PBX Series Quick Fit Connector Bimetallic Steam Traps

Why and How we Use Capacity Control

INTRODUCTION TO. Chapter 15

Design of heat exchangers

WASHING PROCESS OF CARGO TANKS ON TANKERS FOR TRANSPORTATION OF CRUDE OIL

Review on Experimental Analysis and Performance Characteristic of Heat Transfer In Shell and Twisted Tube Heat Exchanger

Alfa Laval plate technology. It s all about optimizing everything

Transformer oil cooler ALFA A02

Oil and Coolant Circulating Heating System. Model - OCSM

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Installation, Operation, & Maintenance Instructions For JFD Shell & Tube Heat Exchangers

MECHANICAL & MARINE ENGINEERING COURSES. This form should be completed by the accountable who conduct courses inside or outside A.R.

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

NFPA31FuelOilPiping 1 Revised

05 Heat Transfer & its Applications

Cooling system components, removing and installing

F L A N G E G A S K E T S

Gas-Fired, Residential Storage Type Water Heaters

Screw Plug Immersion Heaters

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Volkswagen Golf > VW Rabbit GTI 2006->

PIPES AND TUBES FOR HVAC PIPING AND EQUIPMENT

Air Conditioning 101. STN Presentation AC101

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

RODADEACO. Diesel Engine Air Intake Shutoff Valves. Model RDS1 Swing Gate Valve. by AMOT. Overview. Typical Applications. Key Features and Benefits

Oil and Gas Pipeline Design, Maintenance and Repair

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Sam E. Chapple, P. Eng. Chief Technical / Business Development Officer

Shell and Tube Heat Exchanger Design Software for Educational Applications*

SAMPLE TEST QUESTIONS STEAMFITTER/PIPEFITTER - ITA WEBSITE

Acumen Enterprises, Inc.

FLASH TANK ECONOMIZER PRODUCT GUIDE

C. starting positive displacement pumps with the discharge valve closed.

Heater Replacement Procedure

Convection Ovens. BX Classic. Models BX4 / FG 189C, BX / FG 158C, BX10 / FG 180C. Operator's Manual

There are three primary static sealing methods in use today; the flat gasket. And the molded elastomer seal.

Heat Pipe, selection of working fluid

ASME/ANSI B Cast Iron Pipe Flanges and Flanged Fittings ASME/ANSI B Malleable Iron Threaded Fittings ASME/ANSI B16.

HVAC Super Pro FAQ. Can HVAC SUPER PRO be used on both hard and soft copper and aluminum tubing?

Instructions cover both:

Routinely surveying tower overhead vacuum systems can

TITANIUM FABRICATION CORP.

This is the civilian transfer case with the cooling loop only found in the driven gear half of the front case.

STANDARD REQUIREMENTS FOR BONDING OR MECHANICAL ATTACHMENT OF INSULATION PANELS AND MECHANICAL ATTACHMENT OF ANCHOR AND/OR BASE SHEETS TO SUBSTRATES

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

For New Technology Network. Steel Manufacturing Machinery Product Guide Book

COMMERCIAL HVAC CHILLER EQUIPMENT. Air-Cooled Chillers

SECTION 3: CLARIFICATION AND UTILITIES (1)

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Define Fire Stream. A stream of water, or other extinguishing agent, after it leaves the fire hose and nozzle until it reaches the desired point

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

FOAM CHAMBER MODEL - FCA & FCA-S HD FIRE PROTECT PVT. LTD. TECHNICAL DATA FEATURES APPLICATION. Carbon Steel Construction FCA-65, FCA-80 & FCA-100

HIGH STANDARD VALVES FOR NON-STANDARD CONDITIONS.

MAXIMUM HEAT LOAD TEMPERATURE TESTING ( Differential Temperature Testing )

Heat Trace Fundamentals. Monte Vander Velde, P.E. President, Interstates Instrumentation

A GUIDE TO SELECTING YOUR INDUSTRIAL OVEN

Oil Sight Glass BENEFITS

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

CONTAMINANT REMOVAL FROM CENTRIFUGAL SYSTEMS

Installation Instructions

Heat-Pipe Heat Exchanger

The soot and scale problems

OPTIMIZING THE CLEANING OF HEAT EXCHANGERS. Richard E. Putman Conco Consulting Corp.

Fractional Distillation and Gas Chromatography

Steam Coil Installation, Operation and Maintenance

BRAZED PLATE INSTALLATION MANUAL

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

BaseCal 3. BaseCal, the web-based performance calculation tool for Diaphragm Seals

Contents and Nomenclature

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Transcription:

Selecting TEMA Type Heat Exchangers

TEMA is a set of standards developed by leading heat exchanger manufacturers that defines the heat exchanger style and the machining and assembly tolerances to be employed in the manufacture of a given exchanger. TEMA stands for Tubular Exchanger Manufactures Association. An advantage of TEMA standards is that end customers recognize that the specifications set forth comprise industry standards that directly relate to recognized quality practices for manufacturing. Vendors who build to TEMA standards can be competitively compared because tolerances and construction methods should be very similar for a given design. The general description of the three major TEMA classes are: Tema C - General Service TEMA B - Chemical Service TEMA R - Refinery Service Tema R is the most restrictive and TEMA C is the least stringent. TEMA B and TEMA R are very similar in scope. TEMA R includes the requirement for confined gasket joints where recesses must be machined in the flanges and tubesheets. Spiral wound gaskets with a ring construction also meets this TEMA R requirement. TEMA R also requires a greater minimum thickness for some components. This section has the purpose of defining the major TEMA constructions and identify the advantages, limitations and applications suitable for each type. TEMA designations refer to the front head design, the shell design and the rear head design. For example, a TEMA type BEM has a type B front head, a type E shell and a type M rear head design. There are special conditions such as with high vapor flows, high pressure and temperature crossing where a combination of special TEMA features is advantageous. For example, K type shells allow for proper liquid disengagement for reboilers and J and H type shells accomodate high vapor flow. Straight Tube, Fixed Tubesheet, Type BEM, AEM, NEN, Etc. - This TEMA type is the simplest design and is constructed without packed or gasketed joints on the shell side. The tubesheet is welded to the shell and the heads are bolted to the tubesheet. On the NEN heat exchanger, the shell and the head is welded to the tubesheet. Typically, a cover plate design is provided to facilitate tube cleaning. This TEMA category, especially the NEN, it is the lowest cost TEMA design per square foot of heat transfer surface. Less costly than removable bundle designs Provides maximum amount of surface for a given shell and tube diameter Provides for single and multiple tube passes to assure proper velocity May be interchangeable with other manufacturers of the same TEMA type

Shell side can be cleaned only by chemical methods No provision to allow for differential thermal expansion between the outer shell and the tubes. Must use an expansion joint Oil Coolers, Liquid to Liquid, Vapor condensers, reboilers, gas coolers Generally, more viscous and warmer fluids flow through the shell Corrosive or high fouling fluids should flow inside the tubes Removable Bundle, Externally Sealed Floating Tubesheet, Type OP, AEW, BEW This design allows for the removal, inspection and cleaning of the shell circuit and shell interior. Special floating tubesheet prevents intermixing of fluids. In most cases, straight tube design is more economical than U-tube designs. Floating tubesheet allows for differential thermal expansion between the shell and the tube bundle. Shell circuit can be inspected and steam or mechanically cleaned The tube bundle can be repaired or replaced without disturbing shell pipe Less costly than TEMA type BEP or BES which has internal floating head Maximum surface for a given shell diameter for removable bundle design Tubes can be cleaned in AEW models without removing piping. Fluids in both the shell and tube circuits must be non-volatile, non-toxic Tube side passes limited to single or two pass design All tubes are attached to two tubesheets. Tubes cannot expand independently so that large temperature differential applications should be avoided Packing materials produce limits on design pressure and temperature Intercoolers and aftercoolers, air inside the tubes Coolers with water inside the tubes Jacket water coolers, oil coolers or other high differential temperature duty Place hot side fluid through the shell with entry nearest the front end

Removable Bundle, Outside Packed Head, Type BEP, AEP, Etc - This design allows for the easy removal, inspection and cleaning of the shell circuit and shell interior without removing the floating head cover. Special floating tubesheet prevents intermixing of fluids. In most cases, straight tube removable design is more costly than U-tube designs. Floating tubesheet allows for differential thermal expansion between the shell and the tube bundle. Shell circuit can be inspected and steam cleaned. If the tube bundle has a square tube pitch, tubes can be mechanically cleaned by passing a brush between rows of tubes. The tube bundle can be repaired or replaced without disturbing shell piping On AEP design, tubes can be serviced without disturbing tubeside piping Less costly than TEMA type BES or BET designs Only shell fluids are exposed to packing. Toxic or volatile fluids can be cooled in the tubeside circuit Provides large bundle entrance area, reducing the need for entrance domes for proper fluid distribution Shell fluids limited to non volatile, non toxic materials Packing limits shell side design temperature and pressure All tubes are attached to two tubesheets. Tubes cannot expand independently so that large thermal shock applications should be avoided Less surface per given shell and tube diameter than AEW or BEW Flammable or toxic liquids in the tube circuit Good for high fouling liquids in the tube circuit Removable Bundle, Internal Split Ring Floating Head, Type AES, BES, Etc. - Ideal for applications requiring frequent tube bundle removal for inspection and cleaning. Uses straighttube design suitable for large differential temperatures between the shell and tube fluids. More forgiving to thermal shock than AEW or BEW designs. Suitable for cooling volatile or toxic fluids.

Floating head design allows for differential thermal expansion between the shell and the tube bundle. Shell circuit can be inspected and steam cleaned. If it has a square tube layout, tubes can be mechanically cleaned Higher surface per given shell and tube diameter than.pull-through. Designs such as AET, BET, etc. Provides multi-pass tube circuit arrangement. Shell cover, split ring and floating head cover must be removed to remove the tube bundle, results in higher maintenance cost than pullthrough More costly per square foot of surface than fixed tube sheet or U-tube designs Chemical processing applications for toxic fluids Special intercoolers and after coolers General industrial applications Removable Bundle, Pull-Through Floating Head, Type AET, BET, etc. - Ideal for applications requiring frequent tube bundle removal for inspection and cleaning as the the floating head is bolted directly to the floating tubesheet. This prevents having to remove the floating head in order to pull the tube bundle. Floating head design allows for differential thermal expansion between the shell and the tube bundle. Shell circuit can be inspected and steam or mechanically cleaned Provides large bundle entrance area for proper fluid distribution Provides multi-pass tube circuit arrangement. Suitable for toxic or volatile fluid cooling For a given set of conditions, this TEMA style is the most expensive design Less surface per given shell and tube diameter than other removable designs

Chemical processing applications for toxic fluids Hydrocarbon fluid condensers General industrial applications requiring frequent cleaning Removable Bundle, U-Tube, Type BEU, AEU, Etc. - Especially suitable for severe performance requirements with maximum thermal expansion capability. Because each tube can expand and contract independently, this design is suitable for larger thermal shock applications. While the AEM and AEW are the least expensive, U-tube bundles are an economical TEMA design. U-tube design allows for differential thermal expansion between the shell and the tube bundle as well as for individual tubes. Shell circuit can be inspected and steam or mechanically cleaned Less costly than floating head or packed floating head designs Provides multi-pass tube circuit arrangement. Capable of withstanding thermal shock applications. Bundle can be removed from one end for cleaning or replacement Because of u-bend, tubes can be cleaned only by chemical means Because of U-tube nesting, individual tubes are difficult to replace No single tube pass or true countercurrent flow is possible Tube wall thickness at the U-bend is thinner than at straight portion of tubes Draining of tube circuit is difficult when mounted with the vertical position with the head side up. Oil, chemical and water heating applications Excellent in steam to liquid applications