PROFESSIONAL CEMENT PLANT OPTIMIZATION, MODERNIZATION AND ENERGY CONSERVATION



Similar documents
Study tour in two cement plants, Enci and Lixhe and one sewage sludge treatment plant, Waterschapsbedrijf Limburg

INDUSTRIAL PLANTS, COMPUTER & MACHINERY Manufacturing & Trade Co.Ltd.

Research and Development Information

What is Cement? History Overview of the Cement Manufacturing Process Brief Overview of Kiln Operations Why Burn Wastes?

Antonio Jose Cumbane (PhD) Maputo, 31 st May 2011

1.3 Properties of Coal

Installation of Greenfield Vs Brownfield Cement Plant

Iron Ore Processing for the Blast Furnace (Courtesy of the National Steel Pellet Company)

Alternative fuels in cement manufacturing

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Efficiency on a large scale CFB Steam Boilers

Concrete energy savings

Pellet Process - Uses and Exposures

Up-to-Date with Electrical Equipment

1-Some related indicators: Total land area is 1 million Km 2. Only 3% of the land area is arable. The rest 97% is hyper arid desert. The whole lands a

4 Project Description

Tyre Derived Fuel The Basics to Successfully Co-Process Tyre Chips

Recent Development of the Indian Cement Industry...

Thermal & Biogas Production In Egypt. By Prof. Dr. Ahmed Abd El-Ati Ahmed Egypt - GBEP Focal Point

2050 LOW CARBON ECONOMY Executive Summary THE EUROPEAN CEMENT ASSOCIATION

Sustainable cement production CO-PROCESSING OF ALTERNATIVE FUELS AND RAW MATERIALS IN THE EUROPEAN CEMENT INDUSTRY

Modern Sand Reclamation Technologies for Economy, Environment Friendliness and Energy Efficiency

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Stacker and reclaimer systems for cement plants

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

Use of Substitute Fuels in Large Combustion Plants (LCPs)

HANDY MANUAL CEMENT INDUSTRY. Output of a Seminar on Energy Conservation in Cement Industry. Sponsored by

Biomass Energy Demonstration Grant BES Lansing Board of Water & Light

LATEST TRENDS on SYSTEMS (Volume I)

Estimated emissions and CO2 savings deriving from adoption of in-place recycling techniques for road pavements

A guide to volume measurement solutions for the. Mining Industry. Changing the market from level to volume

Wastes co-processing in Holcim

Sewage sludge treatment with oxygen enrichement and oxyfuel combustion in CFBC - new pilot plant results

Optimize Your Process

A guide to solid recovered fuel. Putting waste to good use and producing a sustainable alternative to fossil fuels

Investor Site Visit. Western Cape. 25 March

Maverick Consulting. Engineering and Management Consulting Company

How To Run A Power Plant In Celje

Stora Enso Fors Ltd Sweden

Committed to make a better world

GRECO KILN BURNERS FOR PETCOKE COMBUSTION

Maximization versus environmental compliance

EXECUTIVE SUMMARY. * Power cuts, power trippings and unstable supply voltage.

Chapter 1.3 Energy management & audit

Iron and Steel Manufacturing

IWR Integrated Waste Recycling. Integrated System for treatment and recycling of Municipal Solid Waste

MODERN TECHNOLOGIES FOR ENERGY AND MATERIAL RECOVERY FROM WASTE. Tomáš Rohal, Business Development CEEI 10-Oct-2013

Chapter Two Types of Cement The properties of cement during hydration vary according to:

Improving Energy Efficiency through Biomass Drying

BEST PRACTICES TOWARDS ENERGY EFFECIENCY. UltraTech Cement Limited. (Unit -Kotputli Cement Works)

Silo Plants for Grain, Seed and Foodstuff

SIMPLIFIED BOILER START UP METHOD FOR FLUIDISED BED COMBUSTION BOILERS

Rauhalahti Biomass CHP Plant

Clinker grinding test in a laboratory ball mill using clinker burning with pet-coke and coal

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal

Last update: January 2009 Doc.: 08A05203_e

Pulverized Coal Pipe Testing and Balancing

How To Make Calcium Carbide

I BAU HAMBURG Dry Product Handling

Empresas Asociadas del Noreste

By K.K.Parthiban / Boiler specialist / Venus Energy Audit System

Waste Incineration Plants

SGT5-4000F Trusted Operational Excellence

IMPROVING ENERGY EFFICIENCY IN CEMENT PLANTS

Residues from aluminium dross recycling in cement

IEA Workshop Copenhagen Small scale biomass co-generation with modern steam engines

HAZARD CONTROL TECHNOLOGIES, INC. Coal Silo-Bunker Firefighting Procedures

Cemex: Ecoefficiency Program

Kymijärvi - Lahden Lämpövoima Oy Finland

rbital Fields of application Variants

12 November 2008 *** I:\CIRC\MEPC\01\642.DOC INTERNATIONAL MARITIME ORGANIZATION 4 ALBERT EMBANKMENT LONDON SE1 7SR

SINTERING AND PELLETISATION OF INDIAN IRON ORES

Waste to Energy in Düsseldorf. for a clean city.

Gasification as means of Waste-to-Energy - Main Parameters and application -

ANALYSIS OF ENERGY SAVING OPPORTUNITIES IN CEMENT SECTOR

Cement, Lime and Magnesium Oxide Manufacturing Industries

Lime Kiln Principles And Operations. Outline

Use of Fly ash from KKAB, for sealing of landfills

Embodied CO 2 e of UK cement, additions and cementitious material

Coal ash utilisation over the world and in Europe

Sustainable Resource Management Ltd

COMBLOC The future of packaged multi-fuel fired steam boilers. Ultra Compact. High Performance

Life Cycle Inventory of Portland Cement Manufacture

Data and Trends. Environmental protection and Safety

Phoenix Process Engineering, Inc. Project Experience Helping Clients Achieve MACT Compliance

I. STEAM GENERATION, BOILER TYPES

AGREGADOS RECICLADOS MITOS Y REALIDADES

Finanzierung von Erneuerbaren Energie und Energieeffizienz Projekten in Asien. INTEC Engineering GmbH Berlin,

POROUS BURNER - A New Approach to Infrared

The Global Cement Industry

The Monitoring and Reporting Regulation Guidance on Sampling and Analysis

Tutkimuksen merkitys menestyvässä liiketoiminnassa- Innovaatiosta tuotteeksi

CGA Standard Practices Series. Article 600 Standard for Pozzolan Enhanced Grouts Used in Annular Seals & Well Destruction

E N G I N E E R I N G

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

Enhanced power and heat generation from biomass and municipal waste. Torsten Strand. Siemens Power Generation Industrial Applications

Transcription:

PROFESSIONAL CEMENT PLANT OPTIMIZATION, MODERNIZATION AND ENERGY CONSERVATION Dr. Hans Wilhelm Meyer & Marc Lambert PEG S.A., Geneva, Switzerland ABSTRACT Optimization, modernization and energy conservation projects are on the daily topic-list of every cement plant operation and management. However engineering is not the key-business of a cement plant and hence the resources, the judgement and the overview on technical developments are often limited. For this reason many of such projects fail or its implementation exceeds the related time schedule. Specialized consulting engineers support the cement plants by professional and successful implementation and execution of such projects. At the beginning a plant audit determines the actual situation and the target of the project. On this basis all the aspects of a project, such as technical, commercial, environmental, logistical and organizational are considered, evaluated and elaborated on in a feasibility- and a project study. These documents often have to be of bankable quality and are used for financial and permitting procedures. The border lines between optimization, modernization and energy conservation projects are interactive in many cases. In the following some typical examples of plant optimization, modernization and energy conservation projects are given indicating the wide range of such projects: Typical plant optimization projects: Technical and commercial optimization of the raw mixture, the clinker and the cement quality. Utilization of sewage sludge from waste water treatment plants to save on primary fuel as well as the use of clay as raw material Typical plant modernization projects: Complete consultancy for conversion of a wet- to a dry process plant including capacity increase from 2400 tpd to 4500 tpd. Capacity increase of an existing production line from 2400 tpd to 3000 tpd. Typical plant energy conservation projects: Modification of the coal mill for operation with pre-heater exhaust gas for high volatile coal and utilization of 14 % RDF in the pyro-system. Increase of efficiency and capacity of pre-heater, calciner and cooler. PEG S.A. as the leading independent and international consulting engineer and partner of the Indian Cement Industry supplies experienced consultancy and engineering services for all kinds of plant optimization, modernization and energy conservation on a customized basis for maximum profitability and return of investment.

1. INTRODUCTION Optimization, modernization and energy conservation projects are basically concerning all technical sections and the complete field of operation within a cement plant. Such projects are the key to increase the production output and the profitability. However all the projects have to be carefully planed and executed to receive the maximum benefit whilst also reducing project risks and damages. Specialized consulting engineers support the cement plants by professional and successful implementation and execution of such projects. At the beginning a plant audit determines the actual situation and the target of the project. On this basis all the aspects of a project, such as technical, commercial, environmental, logistical and organizational are considered and elaborated in a feasibilityand project study. These documents often have to be of bankable quality and are used for financial and permitting procedures. PEG services as a leading international and independent consulting and engineering company are not just limited to the project planning but can also include the complete project execution. 2. EXAMPLES OF TYPICAL PLANT OPTIMIZATION PROJECT As there is a wide range of projects and activities only a few typical examples of cement plant optimization, modernization and energy conservation projects executed by PEG will be introduced and discussed. 2.1 TOL CEMENTO / COLOMBIA: TECHNICAL AND COMMERCIAL OPTIMIZATION OF THE RAW MIXTURE, CLINKER AND CEMENT QUALITY The target of this optimization project was to improve the technical, organizational and commercial situation of the raw material preparation and raw mixture design in the Tol Cemento plant of Cementos Argos Group in Colombia. Situation: The pre-mixture consisting of marl, clay, iron ore and chert was prepared on unsuitable dump piles in the quarry area. This dump pile pre-mix was mixed up with limestone on trucks by counting on front loader shovels and jointly dumped into the crusher. The crushed material was transported by a tripper car belt to a stockpile. This resulted in additional disproportioning of the compounds. As a consequence the standard deviation of the LSF in the raw mixtures was ranging from 10 % to 18 % resulting in significant operation problems of the kiln line and unacceptable fluctuations of the clinker quality. Solution: The expansive and complicated but unsuitable pre-mixture preparation on dump piles in the quarry area was eliminated. To mix the various materials and achieve a suitable homogeneity without installation of new crushing equipment the existing crusher was modified into an integrated system (see Fig.1). This was achieved by the addition of a second feed hopper with apron feeder and the installation of a PGNA- Analyser for quality control. This integrated crushing system is operated by proportionally feeding limestone and marl into the first bin and clay into the second feed hopper. The chemical composition of this pre-mixture is controlled automatically by PGNA-online analysis.

Fig.1: Modification of pre-mixture crushing system at Tol Cemento / Colombia. By admixture of clay to the jointly crushed pre-mixture reduced the separation effect caused by the dropping of the pre-mixture by the tripper car. The pre-mixture is corrected by high grade limestone and iron ore. A small quantity of high grade limestone is crushed separately by using the integrated crusher system. For the corrective materials an additional feed bin with a weigh feeder was installed. As a result the standard deviation of the LSF of the raw meal was reduced to 4 %. Further homogenisation is achieved in the homogenization silo. 2.2 ADANA CIMENTO, MESKI & EUB / TURKEY: UTILIZATION OF SEWAGE SLUDGE FROM WASTE WATER TREATMENT PLANT TO SAVE PRIMARY FUEL AND CLAY AS RAW MATERIAL Target of this project was to utilize waste water sewage sludge as an alternate fuel and raw material in the clinker production of the Adana Cimento plant. This project was subsidised by the European Development Bank. The sewage sludge had to be dried to a maximum moisture content of 15 % in the waste water treatment plant to reach the following properties: Properties of Sewage Sludge: Moisture content: 15 % Net Calorific value: 2400 kcal/kg Organical content (dry matter): 55 % Anorganical content (dry matter): 45 % The complete drying, transport and handling facilities were designed. For the successful utilization of the sewage sludge a careful raw mixture calculation including a related fuel scenario (see example Fig. 2) had to be performed considering the influence of heavy metal elements and volatile compounds.

OPTIMIZATION PROJECTS EXAMPLE 2: ADANA CIMENTO, MESKI & EUB / TURKEY: Utilization of sewage sludge from waste water treatment plant to save primary fuel and clay as raw material Properties of Sewage Sludge: Residue Moisture: 15 % Net Calorific value: 2400 kcal/kg Organical content (dry matter): 55 % Anorganical content (dry matter): 45 % Project: Study and design of technology for treatment of sewage sludge in waste water treatment plant, transportation to and handling in the cement plant. Results: Savings of petcoke: Savings of clay: 16 830 T per y 25 245 T per y Savings of fuel costs: 647 000 per y* Savings of raw material costs: 97 000 per y** Total savings: 744 000 per y Investment & operation costs: 2 000 000 Return of inverstment: 2.7 y * 50 USD per T petcoke ** 5 USD per T clay Fig.2: Typical fuel scenario considering the properties of different fuels. Without disposal fee the result of the sewage sludge utilization is represented by the following figures: Results: Savings of petcoke: Savings of clay: 16 830 T per y 25 245 T per y Savings of fuel costs: 647 000 per y* Savings of raw material costs: 97 000 per y** Total savings: 744 000 per y Investment & operation costs: 2 000 000 Return of investment: 2.7 y * 50 USD per T petcoke ** 5 USD per T clay

3. EXAMPLES OF TYPICAL PLANT MODERNIZATION PROJECTS 3.1 AKMENES CEMENTAS / LITHUANIA: COMPLETE CONSULTANCY FOR CONVERSION OF A WET- TO A DRY PROCESS PLANT INCLUDING CAPACITY INCREASE FROM 2400 TPD TO 4500 TPD The target of the ongoing project is the conversion of the existing 2400 tpd (2*1200 tpd) production line to a new dry process line with 4500 tpd clinker production capacity. In addition the specific heat consumption shall be reduced from 1450 kcal/kg to 840 kcal/kg. Also the utilization of waste tires as alternate fuel is a major target of the project. To limit the investment costs to a minimum, the existing limestone crushers, cement mills and kiln foundations have to be used, renovated and extended. To limit project contingencies the execution is based on a multi package project of different suppliers, local erection and local manufacturing. PEG provided to complete techno-commercial feasibility study and performed the complicated tendering, proposal evaluation and contracting and negotiation process. The supervision of the design, the equipment manufacturing and the construction and erection as well as the project management and the commissioning support on site will be performed by PEG. 3.2 COSTA RICA PLANT: CAPACITY INCREASE OF AN EXISTING PRODUCTION LINE FROM 2400 TPD TO 3000 TPD This project is dealing with the second step of the complete capacity upgrade. In the first step a new kiln line with a capacity of 3000 tpd of clinker production was installed (PHASE I). In this PHASE II a full techno-commercial feasibility and CAPEX study was elaborated. It included mainly the following topics: New integrated crushing raw material crushing system in quarry (Capacity 800 tph) 2 km long raw material transport from crusher to stock pile via difficult topography Elaboration of different project options: Extension of existing stock-pile or installation of a new stock-pile. Addition of a second raw mill or replacement of the existing raw mill. Design of a new Pyro-system and raw mill filter. Design of all the relevant transport equipment. Evaluation of all auxiliary equipment for suitable capacity, e.g. compressed air supply, coal grinding and storage, burner capacities, corrective materials crushing, transports and storage

Fig.3: Quarry of Hocim Costa Rica plant. Fig.4: Existing raw meal silo of Holicm Costa Rica. 4. EXAMPLES OF TYPICAL PLANT ENERGY CONSERVATION PROJECTS 4.1 CEMEX SOLID CEMENT / PHILIPPINES: MODIFICATION OF THE COAL MILL FOR OPERATION WITH PRE-HEATER EXHAUST GAS FOR HIGH VOLATILE COAL AND UTILIZATION OF 14 RDF IN THE PYRO-SYSTEM Due to ever increasing fuel costs the target was to change the plants operation from import coal with 25 % volatiles to local lignite coal with up to 40 % volatile matters and a moisture content of up to 20 %. For this reason the coal mill had to be modified form cooler middle air to pre-heater exhaust gas operation. The project was concluded within a very short time schedule of 10 month from begin of the feasibility study until the actual commissioning of the coal mill modification. PEG executed the complete project according to the following topics: Full techno-commerical feasibility study. Turn-key execution of engineering, equipment delivery and installation of the inertization gas project. Execution of coal mill separator modification. Technical key figures: coal mill capacity 20 tph, pre-heater exhaust gas temperature 360 C, fine coal moisture max. 2.0 %. Planning of a rice husk and tyre chip feeding facility to substitute 14 % of the primary fuel. The installed pre-heater exhaust gas duct, shut off gates, dust settling cyclones with dust transports and the fan are displayed in red colour in Fig.5.

Fig.5: General arrangement of the inertization gas modification of the coal mill of Cemex Solid Cement / Philippines. 4.2 CEMEX SOLID CEMENT / PHILIPPINES: INCREASE OF EFFICIENCY OF PREHEATER, CALCINER AND COOLER AND CAPACITY INCREASE FROM 2900 TPD TO 3350 TPD Due to the design of the cyclones and the calciners tertiary air inlet only 2900 tpd clinker production could be achieved. With a pressure loss over top of the pre-heater of 79 mbar and an exhaust gas temperature of 400 C resulted in a specific heat consumption of 950 kcal/kg of clinker. The project was started with a techno-commercial feasibility and engineering study that resulted in the following major modifications: The replacement of the double cyclone stage (I), extension of the calciner to reach a gas velocity of 16 m/s and a retention time of 3.5 s, modification of the tertiary air inlet and installation of new splash plates and hot meal flaps. All the above modifications were engineered and executed in cooperation with PEG s affiliate CME / Philippines on a turn key contract basis. The following results were achieved: Capacity increased from 2900 tpd 3350 tpd. Specific heat consumption was reduced to 760 kcal/kg.

Reduction of pressure loss from 79 mbar to 64 mbar (see Fig.6). Reduction of exhaust gas temperature from 400 C to 365 C (see Fig.7). Increased calciner gas velocity to 16 m/s and retention time to 3.5 sec. for complete combustion of 14 % AFR. Project time from feasibility study to commissioning 10 month. p-profile of Preheater p (mbar) 90.0 80.0 70.0 60.0 50.0 40.0 30.0 20.0 10.0 0.0 p meas. AVG p after modification Cyclone I Cyclone II Cyclone III Cyclone IV Cyclone V Inlet Cham, Fig.6: Pressure loss profile of thermal pre-heater and calciner of Cemex Solid Cement / Philippines before and after modification. 1200.0 T-Profile of Preheater 1000.0 T ( C) 800.0 600.0 400.0 200.0 T meas. AVG T after modification Cyclone I Cyclone II Cyclone III Cyclone IV Cyclone V Inlet Cham, Fig.7: Temperature profile of thermal pre-heater and calciner of Cemex Solid Cement / Philippines before and after modification.

4. CONCLUSIONS A sophisticated and well experienced plant audit and project study is the basis of every successful project within an existing cement plant. Practically all types of projects from plant optimization, modernization, upgradation and adaptation need to be properly elaborated and evaluated before any major investment can be considered. All aspects - technical, organizational, logistical, environmental, market and commercial have to be covered. Cement plant optimization, modernization and energy conservation projects and related planning should be carried out by excellent, experienced and independent experts and engineers. Similar studies executed by equipment suppliers could result in a conflict of interests and are usually of non-bankable quality. PEG S.A. has 42 years of consulting experience and has proven excellence within the cement industry, With our worldwide references and our abilities we are able to cover all types of projects with detailed know-how and experience. This is particularly in the case concerning the cement manufacturing- and the secondary fuel technology. PEG S.A. is the leading international and independent consulting engineer and a reliable partner to the Indian Cement Industry. PEG S.A. offers its services for customized and successful solutions for all projects.