Lenntech info@lenntech.com www.lenntech.com Tel. +31-15-261.09.00 Fax. +31-15-261.62.89



Similar documents
Food and Beverage Food & Beverage

Lenntech Tel Fax

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic

Durapore 0.45 μm Hydrophilic Filters

LifeASSURE 020SP. Series Capsules & Cartridge Filters. Sterilising Grade Nylon 6,6 Membrane Filter

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure

Viresolve. NFP Filter. Lenntech. Fast, reliable parvovirus removal. Membrane Type. Filter Formats. Rapid, Reliable

3M Housings DS Series

Assembly and Installation Procedures

LifeASSURE BLA. Series cartridge fi lters

LifeASSURE PFS Series Filter Cartridge Integrity Testing

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

Lenntech ZETA PLUS CP & SP SERIES GRADE CHOICE. Pharmaceutical Applications

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

USD Pall Filter Housings for Depth Filter Modules. Stainless Steel Housings designed for the Biopharmaceutical Industry

Baumann Flexsleev Sanitary Control Valve

Sterile Acrodisc Syringe Filters

Application Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Flow Sensors. Convenient, Reliable and Economical Flow Measurement. THORNTON Leading Pure Water Analytics

Total Chromatography Solutions. Pall Filter Modules and Capsules with Seitz Depth Filter Sheets

PolyKLEAN. Featuring: All-Polypropylene Rigid Thermal Bonded Filters. Applications Include:

SUPRApak S Series Filter Housings SUPRApak Filtration For Small Batch Depth Filtration

CSF16 and CSF16T Stainless Steel Steam Filters

SUPRApak Multi-Stack Series Filter Housings SUPRApak Filtration For High Volume Depth Filtration

Ultipleat High Flow Filter System

Validation Guide. USTR 805j (5) Steam sterilization of Pall filter assemblies which utilize replaceable filter cartridges

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

relief valves 500 Series Adjustable Popoff & Inline Relief Valves 0.5 to 150 psig (10 bar)

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples

Proportional Relief Valves

TECHNICAL BRIEF. Microfluor II Filter Cartridge Integrity Testing. Introduction. Forward flow integrity test. 1. Definition

BURSTCHECK LINE OF RUPTURE DISC BURST INDICATORS

Operating Instructions

ISORIA. Centered disc butterfly valves with AMRING elastomer liner. 240 PSI: 1½ to PSI : 10 to 24

Instruction Manual. Alfa Laval SB Membrane Sample Valve ESE02963-EN

Uncompromising Customer Service. Baumann TM Sanitary and Aseptic Process Valves

SANIC SEDIMENT CARTRIDGES

Overview. Optimizer Bulk

Cartridge Filter Application Notes

SUPRApak M Series Filter Systems SUPRApak Filtration For Medium Batch Depth Filtration

Pharmatec GmbH. Packaging Technology. Pharmatec GmbH

Resolute FM mm I.D. Chromatography Columns for Pilot or Production Use

Ultra-Filter. Compressed Air Filter. DF Series

VAD. Variable Area Desuperheaters

OIL-X EVOLUTION Compressed Air Filters ENGINEERING YOUR SUCCESS. TECNI-AR Ltda - Tel: w.tecni-ar.com.br

Piston Accumulators. SK Series. Accumulator Catalog. Piston Types. Description. Sealing Systems. End Cap. O-ring. Sealing System. Piston.

Betapure AU. Cartridges & Capsules. Lenntech. Rigid Filter Media. 3M Purification Product Brochure

Typical Aluminum GFM Mass Flow Meter

OT 40L / 90L. Laboratory Steam Sterilizers

Fittings, Tubing & Nipples

Design of Purified Water and Water For Injection Systems. Hugh Hodkinson Engineers Ireland Chemical & Process Division

To meet the demands of a high-purity deionized (DI) water system, filters must:

P-EG stainless steel housing for gas filtration

USP CLASS VI GASKETS PRODUCTS OF INTEGRITY...FROM PEOPLE OF INTEGRITY

CUNO TM Series NB Bags for Liquid Filtration

SUPRAdisc. Depth Filter Modules

Confidential. Proportional reducer D386 ATEX. Male base connector View from weld side

NORMAN FILTER COMPANY PRODUCT OVERVIEW

Customer Application Brief. Filtration Processes Applied in Therapeutic Monoclonal Antibody Production. Bioprocess, Biologicals, & Pharmaceutical

Return line filters. Return line filters

German engineering under high pressure

ThermoSorb Desiccant Dryers

BIOFIL Terminal Filters

How single-use connections advance aseptic processing: Increased process flexibility and reliability, reduced costs

Cadence Acoustic Separator

PBX Series Quick Fit Connector Bimetallic Steam Traps

OEM-EP Pressure Controllers

RMF TANDEM 900 OFF-LINE FILTER SYSTEMS

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Micro Motion Model D and DL Coriolis Flow and Density Meters

VDL 53 - Vacuum drying oven for flammable solvents

STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:

NEWMAN NEWFLO. Replacement Diaphragms for ITT, Saunders and Gemü Valves PRODUCTS OF INTEGRITY...FROM PEOPLE OF INTEGRITY

Rated Burst Pressure 200 Series: 2.5 : 1 H200 Series: 4 : 1

Miniature Pneumatic Solenoid Valve. Power Options: 0.5 Watt (6 psig model) 1.0 Watt (30, 100 psig model) Voltage Options: 3, 5, 12 or 24 VDC

Gas Mass Flow Control Products

Energy Recovery Device isave 21-40

HDC II Pleated, Tapered Pore Polypropylene Filter Elements

API Flanged Safety Relief Valves Series 526 CATALOG

Stainless Steel Valves For the Sanitary Industries

BRIEFING Plastic Packaging Systems for Pharmaceutical Use.

High Flow. Filtration. Performance. in a Compact Design. 3M Filtration Full Line Catalogue

UltraClean PCR Clean-Up Kit

TY-FLO Needle Valves

CRN A-F-G-E-HQQE 3x400D 50 HZ

Operating Instructions for Plastic Flow Meter. Model: KSK

How To Use A Flowmeter

Integration of a disposable system in a traditional manufacturing process to terminal sterilization

Laboratory- and sterilisation equipment HMC EUROPE

Innovation and Progress in Water Treatment Technology

Innovative to the Core

Quick Connect Boxes Inside Gloveboxes

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

MFP14, MFP14S and MFP14SS Automatic Pumps

Laminar Flow Cabinets

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Duplex Filters 40 FLDK 0008(C)-0120(C)

Transcription:

Lenntech info@lenntech.com www.lenntech.com el. +526.9. Fax. +526.62.89 EPOR IR Filter Cartridges air / gas filters expanded PFE EPOR IR sterilization filter cartridges offer exceptional filtration performance while providing the highest levels of biosecurity throughout the process industry. Operating at ambient temperature conditions, EPOR IR filter cartridges provide a costeffective filtration solution. unique polypropylene prefilter layer extends service life in heavily contaminated environments. EPOR IR filter cartridges also utilize a wellproven, inherently hydrophobic expanded PFE membrane validated as sterilizing grade in liquid in accordance with SM F885. his ensures the removal of all airborne bacteria, viruses and bacteriophage. Features and Benefits ssured biosecurity with absolute rated filtration High flow rates with low pressure drops Steam sterilizable to 42 C (287.6 F) Unique prefilter layer High voids volume PFE membrane ote: EPOR is a registered trademark of Parker domnick hunter Performance Characteristics Differential Pressure (mbar) 9 8 7 6 5 4 2 barg 2 barg 2 4 5 6 7 Flow (m / hr) (air @ 2 C) 2 9 8 7 6 5 4 2 Differential Pressure (psi) Differential Pressure (mbar) 9 8 7 6 5 4 2 barg 2 barg 2 4 6 8 2 4 6 8 Flow (m / hr) (air @ 2 C) 4 2 8 6 4 2 Differential Pressure (psi) Size (25 mm) Cartridge B Size (65 mm) Cartridge

EPOR IR Filter Cartridges Specifications Materials of Construction Filtration Membrane: Expanded PFE Upstream Support: Downstream Support: Filter Cartridges Inner Support Core: Outer Protection Cage: End Caps: End Caps Insert: 6L Stainless Steel Standard orings/gaskets: Silicone MURUS Disposable Filter Capsules Core: Sleeve: Standard orings: Viton Capsule Body: Capsules Vent Seals: Silicone DEMICP Filter Capsules Core: Sleeve: End Caps: Capsule Body: Capsules Vent Seals: Filling Bell: Silicone Polycarbonate Effective Filtration rea (EF) (25 mm):.77 m 2 (8.28 ft 2 ) K Size:.6 m 2 (.87 ft 2 ) Size:.25 m 2 (2.69 ft 2 ) B Size:.2 m 2 (.29 ft 2 ) E Size:.6 m 2 (.64 ft 2 ) Syringe ø5 mm: 4.5 cm 2 (2.25 in 2 ) Sterilization utoclave SteaminPlace Cycles emp Cycles emp ( min.) Cartridges 2 42 C (287.6 F) 2 42 C (287.6 F) MURUS 5 C (266 F) DEMICP 5 C (275 F) Syringe C (266 F) For detailed operational procedures and advice on cleaning and sterilization, please contact the echnical Support roup through your usual Parker domnick hunter contact. Food and Biological Safety Materials conform to the relevant requirements of 2CFR Part 77 and current USP Plastics Class VI 2 C and ISO99 equivalents. Quality Standards Pharmaceutical grade products are manufactured in accordance with cmp, % flushed with pharmaceutical grade purified water and integrity tested prior to despatch. sample of each lot is tested to demonstrate conformity to validated claims. Syringe Filters Body: Recommended Operating Conditions Filter Cartridges Up to 6 C (4 F) continuous operating temperature and higher shortterm temperatures during CIP to the following limits: emperature Max. Forward dp C F (bar) (psi) 2 68 5. 72.5 4 4 4. 58. 6 4. 4.5 8 76 2. 29. 9 94.7 24.6 MURUS Disposable Filter Capsules Up to 25 C ( 77 F) @ 5.5 barg (79.7 psig) Up to 6 C (4 F) @ 2.8 barg (4.6 psig) Parker Hannifin certify that this product complies with the European Council Pressure Equipment Directive (PED) 97/2/ EC rticle, Paragraph Sound Engineering Practice (SEP). his product is intended for use with roup & 2 Dangerous and Harmless Liquids and roup 2 Harmless ases at the operating conditions stated in this document : In compliance with PED rticle, Paragraph, SEP, this product does not bear the CE mark. DEMICP Filter Capsules Up to 4 C (4 F) at line pressures up to 5. barg (72 psig).

EPOR IR Filter Cartridges Performance Characteristics OC / Conductivity he filtrate quality from a (25 mm) EPOR IR conforms to the requirements of current USP <64> (OC) and USP <645> (conductivity). Endotoxins queous extracts from the (25 mm) EPOR IR contain <.25 EU / ml when tested in accordance with the Limulus moebocyte Lysate test. onvolatile Extractables (VE) otal VEs extracted in the first 5 litre flush of purified water for a (25 mm) cartridge are <5 mg. Pharmaceutical Validation full validation guide is available upon request from Laboratory Services roup (LS). Oxidizable Substances EPOR IR filter cartridges meet current USP and EP quality standards for sterile purified water for oxidizable substances following a < litre water flush. Integrity est Data ll filters are integrity testable to the following limits when wet with 6 / 4 : IP /water and using air as the test gas. Cartridge est Diffusional Water Water Water Pressure Flow Intrusion Intrusion Flow est Pressure (barg) (psig) (ml / min) (barg) (psig) (ml / min) / min) (µl E.8.6.5 2.5 6.. 7 B.8.6. 2.5 6. 2.6 742.8.6 6. 2.5 6. 5. 54 K.8.6 8.5 2.5 6. 7.5 242.8.6 8. 2.5 6. 6. 457 Retention Characteristics EPOR IR filter cartridges are validated by bacterial challenge testing with Brevundimonas diminuta to current SM F885 methodology ( 7 organisms / cm 2 EF minimum) with typical inhouse challenge levels being organisms per (25 mm) filter cartridge.

EPOR IR Filter Cartridges Ordering Information Cartridges ZCM / Code ǀ Length (ominal) Code ǀ Endcap ( ) Code ǀ Orings B* 2.5 (65 mm) * 5 (25 mm) K 5 (25 mm) (25 mm) 2 2 (5 mm) (75 mm) * Supplied in packs of. B* dh DOE C BF / 226 Bayonet D Fin / 222 E Flat op / 222 F BF / 26/28 Recess / 222 H UF Retrofit R BF / 222 Bayonet ir / as E EPDM P PFE Encapsulated Silicone S* Silicone V Viton * Silicone oring supplied as standard without having to specify the S code. * EPDM gaskets supplied as standard. Code ǀ Endcap (Demi) SK Retrofit RUESEL X 6 Y Demi Stub Z Demi & B Std MURUS Capsules ZLM Code ǀ Length (ominal) Code ǀ rade Code ǀ Design Code ǀ Orings K 5 (25 mm) (25 mm) 2 2 (5 mm) (75 mm) B D / 4 riclamp / 2 riclamp Hosebarb riclamp B D / 4 riclamp / 2 riclamp Hosebarb riclamp ir / as onsterile L InLine * Port * Only available with a riclamp. E EPDM S* Silicone V Viton * Silicone oring supplied as standard without having to specify the S code. DEMICP Capsules ZEM Code ǀ Length (ominal) Code ǀ rade Code ǀ Pack E 4.4 ( mm) B 5.5 (4 mm) 7.9 (2 mm) H M Q R V riclamp / 2 P Male / 2 Hosebarb / 4 P Male Walther QC rommel / QC / 8 P Female H M Q R V riclamp / 2 P Male / 2 Hosebarb / 4 P Male Walther QC rommel / QC / 8 P Female ir / as onsterile Pack of Syringe Filters ZSM Code ǀ Diameter Code ǀ rade Code ǀ Options Code ǀ Pack 5 5 mm L / 8 P Male L / 8 P Male P Pharmaceutical onsterile S Standard 25 25 per box Parker domnick hunter has a continuous policy of product development and although the Company reserves the right to change specifications, it attempts to keep customers informed of any alterations. his publication is for general information only and customers are requested to contact our Process Filtration Sales Department for detailed information and advice on a products suitability for specific applications. ll products are sold subject to the company s Standard conditions of sale. DS_F_6_/2 Rev. 4B

he below Parker EPOR Liquid series cartridge filters are all the models that are potentially possible in all variations. Please note that not all models are actually produced or on stock and some model numbers and names have become obsolete. evertheless this should help as cross reference table chart for Cuno filters nomenclature. EPOR ir ZCMB 2B ZCM 2B ZCMB 2B ZCM 2B ZCMK 2B ZCM 2B ZCM2 2B ZCM 2B ZCMB 2C ZCM 2C ZCMB 2C ZCM 2C ZCMK 2C ZCM 2C ZCM2 2C ZCM 2C ZCMB 2D ZCM 2D ZCMB 2D ZCM 2D ZCMK 2D ZCM 2D ZCM2 2D ZCM 2D ZCMB 2E ZCM 2E ZCMB 2E ZCM 2E ZCMK 2E ZCM 2E ZCM2 2E ZCM 2E ZCMB 2 ZCM 2 ZCMB 2F ZCM 2F ZCMK 2F ZCM 2F ZCM2 2F ZCM 2F ZCMB 2R ZCM 2R ZCMB 2 ZCM 2 ZCMK 2 ZCM 2 ZCM2 2 ZCM 2 ZCMB 2SK ZCM 2SK ZCMB 2H ZCM 2H ZCMK 2H ZCM 2H ZCM2 2H ZCM 2H ZCMB 2 ZCM 2 ZCMB 2R ZCM 2R ZCMK 2R ZCM 2R ZCM2 2R ZCM 2R ZCMB 2Y ZCM 2Y ZCMB 2SK ZCM 2SK ZCMK 2SK ZCM 2SK ZCM2 2SK ZCM 2SK ZCMB 2Z ZCM 2Z ZCMB 2 ZCM 2 ZCMK 2 ZCM 2 ZCM2 2 ZCM 2 ZCMB 2 ZCM 2 ZCMB 2X ZCM 2X ZCMK 2X ZCM 2X #REF! ZCM 2X ZCMB 2Y ZCM 2Y ZCMB 2Y ZCM 2Y ZCMK 2Y ZCM 2Y ZCM2 2Y ZCM 2Y ZCMB 2Z ZCM 2Z ZCMB 2Z ZCM 2Z ZCMK 2Z ZCM 2Z ZCM2 2Z ZCM 2Z ZLMK 2 ZLM 2 ZLM2 2 ZLM 2 ZLMK 2B ZLM 2B ZLM2 2B ZLM 2B ZLMK 2D ZLM 2D ZLM2 2D ZLM 2D ZLMK 2 ZLM 2 ZLM2 2 ZLM 2 ZEME 2 ZEMB 2 ZEM 2 ZSM5 2 ZEME 2 ZEMB 2 ZEM 2 ZSM5 2L ZEME 2H ZEMB 2H ZEM 2H ZEME 2 ZEMB 2 ZEM 2 ZEME 2M ZEMB 2M ZEM 2M ZEME 2Q ZEMB 2Q ZEM 2Q ZEME 2R ZEMB 2R ZEM 2R ZEME 2V ZEMB 2V ZEM 2V