MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS
POER, FLEXIBILITY, RESIDENTIAL Carrier presents the new line of multi-split systems A complete and flexible range designed to meet every residential and light commercial requirement. - compact and stylish - 6-position adjustable airflow - available with new AIR4LIFE purification system - new slimline shape for low wall or ceiling suspended applications - high-efficiency personalised air distribution - titanium photocatalytic filters - available in white or aluminium finish 14 MO from 3 to 14 cooling only models + - invisible comfort - very slim and lightweight My Comfort Infrared ergonomic control for comfort management. A NE SMART MODULAR
STAMINA, VERSATILITY The entire range operates on R410A refrigerant and the new single modular controllor allows any combination of indoor and outdoor unit. COMMERCIAL - powerful yet quiet - remotely adjustable airflow - AIR4LIFE photocatalytic purification system - the ultimate modular unit - full flexibility for any application DELS ranging power Room Controller Controls up to 6 room units with the same operating setting. heat pump models ELECTRONIC INTERFACE Zone manager The building supervisor which can program up to 32 different indoor units in 8 independent zones. - slimline shape - low wall or ceiling suspended applications - ideal for applications where style, performance and quality are essential
CARRIER CONDENSER TECHNOLOGY. AHEAD OF THE PACK Choose from 14 models, cooling-only or heat pump, ranging from 3 to 14. Powerful... New outdoor condensing units keep Carrier at the cutting edge of air conditioning design. Lanced sine wave fin technology maximises the heat exchange performance. Silent... Now quieter than ever with compressor sound shields and advanced 4-blade fan design. Compact... New slim and stylish units... and ecological Carrier s new generation of condensing units operate on R410A, the non-ozone depleting refrigerant, also known to be the most efficient and energy-saving refrigerant for split systems. For economy Carrier has developed the multisplit with split compressor ideal for air conditioning spaces where maximum conditioning power is not required simultaneously, such as the daytime and nighttime areas of a house. Smart valve management enables the split compressor to power two indoor units to two different temperatures, optimising energy consumption and offering maximum comfort both day and night. NIGHT COMFORT DAY COMFORT For power here maximum power is required in more than one space simultaneously, such as shops and offices. Carrier offers models with two dedicated compressors, each serving one indoor unit, ensuring the power of each compressor is exploited to the full.
FLEXIBILITY, CONTROL AND COMFORT Choice... For maximum simplicity and adaptability, the same unit can be used as single split or multisplit in a wide variety of applications. Versatile... Mix and match as it suits you. ith the new Carrier multisplit, units from 2.5 up to 7 can be combined in any number of different ways. A new smart electronic interface Plus, thanks to the new Global Modular Control, all Carrier indoor and outdoor units are completely compatible. Flexible... One single multi-feature electronic board can now handle a large number of domestic and business capabilities, including running as part of a network. All fully compatible with current legislation, particularly on immunity and emis ns. Total compliance The systems are fully compatible with current legislation, particularly on immunity and emissions. Simpler, more reliable installation New developments reduce the number of wires in heat pump systems, resulting in faster and simpler installation, more reliability and longer component life. AIR4LIFE for improved air quality Available as an option on the HMC high wall units and cassette, the innovative AIR4LIFE system traps impurities to give fresh, clean air. 1. Pre filter: removes dust and pollen particles in suspension in the atmosphere 2. Electrostatic filter: traps spores, bacteria and fine dust 3. Titanium Photocatalytic filter: eliminates odours and bacteria down to 0.01 micron diameter
SYSTEM PER DUALSPLIT COOLING ONLY 38GL2MG 1 Shared 38GL2MG 1 Shared 38GL2M18G 38GL2M24G 38GL2M36G 38GL2M48G 38GL3M21G 1 Dedicated 1 Shared 38GL3M21G 1 Dedicated 1 Shared 38GL4M24G 2 Shared 38GL4M24G 2 Shared 38GL4M24G 2 Shared 18 18 24 24 TRI SPLIT COOLING ONLY QUADRI SPLIT COOLING ONLY 38YY2MG 38YY2M21G 38YY2M24G 38YY2M36G 38YY2M48G DUAL SPLIT HEAT PUMP 18 18 24 24 42HMC_N 42VMC_N 40KMC_N 40SMC_N 3,80 3,76 3,10 1450 1440 1610 2,62 2,61 2,42 3,81 3,78 3,1 1460 1450 1620 2,61 2,61 2,41 5,16 5,00 5,51 2000 160 2580 2,58 2,55 2,14 6,83 6,8 7,17 7,00 2560 2550 2670 2840 2,67 3,70 2,6 2,46 11,33 11, 11,58 10,22 4010 4000 4040 4200 2,83 2,78 2,87 2,43,50,80 13,15,50 4870 470 450 5060 2,57 2,58 2,66 2,47 5,86 5,82 5,2 2210 2205 2450 2,65 2,64 2,42 5,0 5,86 5,6 2220 2220 2470 2,66 2,64 2,41 6,6 7,02 7,13 2580 2570 2870 2,70 2,73 2,48 7,00 7,05 7,17 2610 2600 200 2,68 2,71 2,47 7,04 7,10 7,21 2650 2630 240 2,66 2,70 2,45 5,3 5,64 5,2 5,58 5,05 5,48 180 1820 1800 1840 2000 140 2,85 3,10 2,4 3,03 2,53 2,82 6,28 6,77 6,16 6,67 5,84 6,47 2140 2230 2040 2260 2280 2370 2,3 3,04 3,02 2,5 2,56 2,73 6,64 6,2 6,50 6,80 6,62 6,6 6, 6,50 240 2360 2380 2380 2470 2330 2670 240 2,67 2,3 2,73 2,86 2,68 2, 2,2 2,61 10,85 11,3 10,88,32 10,74 13,02 10,07 11,71 3820 3670 380 3840 340 3840 4050 4150 2,84 3,25 2,73 3,21 2,73 3,3 2,4 2,82,08 14,1,7 13,84,71 13,56,08 14,1 4580 4880 4750 5010 4650 5050 4260 4670 2,64 2,1 2,73 2,76 2,73 2,6 2,84 3,04 Data refers to combinations with one type of indoor units.
FORMANCES 42HMC_N 42VMC_N INDOOR UNIT 0 18 24 0 18 24 Dehumidification l/h 0,0 1,32 1,7 2,5 1,2 1,5 2,0 2,2 Air flow (l/m/h) l/s 104/118/135 10/3/138 206/233/261 233/261/28 78/88/100 85/6/114 136/162/1 164/202/24 Sound pressure (l/m/h) db(a) 1 32/34/36 33/35/37 38/40/42 41/43/45 33/36/3 36/38/42 38/41/45 41/44/4 Sound power (l/m/h) db(a) 45/47/4 46/48/50 51/53/55 54/56/58 44/47/50 47/4/53 4/52/56 52/55/60 Dimensions (H x L x D) mm 260x815x185 25x1080x185 540 x 850 x 200 4/52/56 52/55/60 eight kg 14,5 15 16 18 Power supply V-ph-Hz 230-1-50 230-1-50 40KMC_N 40SMC_N INDOOR UNIT 18 24 0 18 24 Dehumidification l/h Air flow (l/m/h) l/s Static pressure Pa Sound pressure (l/m/h) db(a) 1 Sound power (l/m/h) db(a) Dimensions (H x L x D) mm eight kg Power supply V-ph-Hz Sound pressure level referred to an hemisherical radiation over a reflecting plane at a distance of 4 m. 0,8 1, 2,5 0,5 0,8 1, 2,5 152/167/183 156/175/14 18/213/250 2/103/133 103/118/13 6/14/182 161/16/247 33 40 45 60 27/31/34 30/33/36 35/38/42 31/32/33 31/32/34 32/34/36 35/37/3 40/44/47 43/46/4 48/51/55 47/48/4 48/4/50 48/50/52 51/53/55 250x70x186 220 x 725 x 555 17,5 1 23 38 230-1-50 230-1-50 38GL3MG Indoor Cooling Capacity () units TOTAL Unità A1* Unità A2* 00 3140 3140 0 3250 3250 00+00 3800 100 100 00+0 3810 1880 130 38GL3M21G Indoor units Cooling capacity () Comp. A Comp. B TOTAL Unit A1* Unit A2* Unit B** 00 2320 2320 00 280 280 0 270 270 0 00 5250 250 2300 00+00 3580 170 170 00 00 5170 2870 2300 00+00 00 5860 1780 1780 2300 00+0 00 500 1780 1820 2300 38GL4M24G Indoor units Cooling capacity () Comp. A Comp. B TOTAL A1* A2* B1** B2** 00 2830 2830 0 2870 2870 00+00 3600 1800 1800 00+0 3640 1800 1840 00 00 5420 2710 2710 00 0 5470 2710 2760 0 0 5500 2750 2750 00+00 6220 1740 1740 2740 00+0 00 6260 1740 1780 2740 00+00 0 6260 1740 1740 2780 00+0 0 6300 1740 1780 2780 00+00 00+00 660 1740 1740 1740 1740 00+00 00+0 7000 1740 1740 1740 1780 00+0 00+0 7040 1740 1780 1740 1780 * Circuit Unit A **Circuit Unit B Cooling: outdoor air temperature 35 C dry bulb / 24 C wet bulb, indoor air temperature 27 C dry bulb / 1 C wet bulb. Data referred to combination with 42HMC_N
TECHNICAL DATA HEAT PUMP low ambient 38YYS2M36G 38YYS2M48G HEAT PUMP 38YY2M18G 38YY2M21G 38YY2M24G 38YY2M36G 38YY2M48G COOLING ONLY 38GL2MG 38GL2M18G 38GL2M24G 38GL3M21G 38GL4M24G 38GL2M36G 38GL2M48G Max pipe length* m 15 15 15 15 15 30 30 40 Max height difference* m 5 5 5 5 5 5 10 15 No. of compressors 1 shared 2 dedicated 2 dedicated 2 dedicated 1dedic.+1 shar. 2 shared 2 dedicated 2 dedicated Compressor type Rotary Rotary Rotary Rotary Rotary Rotary Rotary Rotary Chargeless (per circuit) m 15 8 8 8 15+8 15+15 8 8 Sound pressure db(a) 1 43 45 48 48 46 50 4 50 Sound power db(a) 63 65 68 68 66 70 6 70 Dimensions (H x L x D) mm 504x660x220 803x800x300 803x800x300 50x800x300 50x800x300 803x800x300 64x800x300 64x800x300 eight CO/HP kg 3 55/5 61 64/65 58 6 /100 102/104 (liquid/gas) circuit A in 1/4-3/8 1/4-3/8 1/4-1/2 1/4-1/2 1/4-3/8 1/4-3/8 1/4-1/2 1/4-1/2 circuit B in 1/4-1/2 *** 1/4-3/8 1/4-3/8 1/4-1/2 1/4-1/2 *** 1/4-1/2 *** 1/4-1/2 1/4-1/2 circuit C in 1/4-3/8 1/4-3/8 circuit D in 1/4-1/2 *** Power supply V-ph-Hz 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 230-1-50 1 Sound pressure level referred to an hemispherical radiation over a reflecting plane at a distance of 4 m * Per single or shared circuit *** Flare tap adapter supplied for 3/8 pipes (IDU size ) OPERATING LIMITS COOLING MODE HEATING MODE maximum conditions minimum conditions maximum conditions minimum conditions outdoor temperature 43 C indoor temperature 32 C dry bulb / 23 C wet bulb outdoor temperature 15 C (-10 C for Low-Ambient versions) indoor temperature 21 C dry bulb / 15 C wet bulb outdoor temperature 24 C dry bulb / 18 C wet bulb indoor temperature 27 C outdoor temperature -15 C dry bulb / 17 C wet bulb indoor temperature 20 C LO-AMBIENT PERFORMANCE The outdoor temperature limit in cooling mode is -10 C for Low-Ambient versions 38YYS2M36G and 38YYS2M48G. The same performance is available for all cooling-only models (except 38GL3M21G) through Low-Ambient kits. Carrier Air Conditioning Ltd United Technologies House Guildford Road Leatherhead Surrey KT22 UT Tel: 01372 220220 -Fax: 01372 220241 www.uk.carrier.com