Smile 11 AS-i Emergency stop with safe AS-i input node

Similar documents
Tina 2A/B Adaptor unit

Original instructions Tina 3A/Aps Adaptor unit

Safety Manual BT50(T) Safety relay / Expansion relay

Safety Contact Bumper ASB-series

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

CQM1-SF200/CS1W-SF200

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

Machine Safety Switch: SI-LM40 Series Limit Switch Style

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Operating instructions Diffuse reflection sensor with background suppression O1D101 O1D / / 2012

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Application Technique. Safety Function: Magnetic Door Switch Monitoring

3M Wrist Strap and Footwear Tester 740. User s Guide

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

TTL to RS232 Adapter User Guide

USB Port Hub with USB Power Cable. User s Manual

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Infrarot-Bewegungsmelder IP44

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

Part I - Installation

user s manual Battery Case model #: SPB3200 Battery Case Charger for Samsung Galaxy S 4

Wiring Instructions and Operating Manual 12 POINT ULTRABEAM REMOTE MONITORING SYSTEM

Wireless Indoor/ Outdoor Thermometer

Machine Safety Switches

Advantium 2 Plus Alarm

User and Installation Guide

Single Port T1/E1 Tap

Kvaser Mini PCI Express User s Guide

Dual-Cool Notebook Cooler Pad. User s Manual

±15 V Current-Limited Power Supply

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

User Manual Revision English

User Manual Revision English

USER MANUAL. Kramer Electronics, Ltd. Models:

15 Digital Photo Frame Instructional Manual

WINEGARD MOTORIZED SENSAR ANTENNA Models MA1055W & MA1055G MADE IN U.S.A. U.S. Patents D500,496 and 7,358,909 INSTALLATION MANUAL

Smart Safety and Motion Analyser Tool

DUAL%CHANNEL BROADBAND%LINEAR%AMPLIFIER Model&A800D

CONFIGURABLE SAFETY RELAYS

Leak Detection System

Machine Automation Controller NJ-series. Startup Guide. for Motion Control W514-E1-01

Sunny Boy Accessories SMA POWER BALANCER

Nokia Bluetooth Headset BH-101. Issue 1

LOSB9595 1/36 th Brushless ESC and 10250Kv Motor Combination

Installation guide H A. HSI hardwired system interface

Nokia Bluetooth Headset BH-104

XUSL4E4BB091NS2 XUSL type 4 - Slave2 - For body protection - 4 Beams, Hp = 910 mm

User Manual Revision English

FriendlyNet Hub 5-Port or 8-Port Ethernet Hub User s Manual

CONFIGURABLE SAFETY RELAYS

Single Station Remote Alarm

Nokia Bluetooth Headset BH /1

2-Way Wireless Indoor Siren Installation Guide

USER MANUAL. Kramer Electronics, Ltd. Models:

Warranty Terms. QLogic-provided cables, optics and other accessories are warranted for ninety (90) days from date of purchase.

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

How To Use A Cdm250 Digital Multimeter

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Owner s Manual & Safety Instructions

PLUTO Safety-PLC. Manual Absolute Encoders

User Guide. HDMI Active Cable Extender. DVI-7370c

Model SPDT Relays

Brushless Motors Instructions

HDMI Fiber Optic Cable. DVI-D Fiber Optic Cable. User Guide

AM/FM Emergency Weather Radio/Light With Hand Crank Back-Up Power

VARIO PROX CARD READER INSTALLATION MANUAL

User Manual Revision English

AXIS T81B22 DC 30W Midspan

Antenna Splitter ASA 1. Instruction manual

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

WD-AMX Water Detection Controllers

Resolution (divisions) Pre-wired Model E6F-AB3C 360P/R 2M *2 Pre-wired Connector E6F-AB3C-C 360P/R 2M *2 Model (2 m) NPN open collector BCD 360

Nokia Bluetooth Headset BH-109

ADM1TE 5/30A DIN rail single phase two wire energy meter

Mini Power Bank and Charger

Quick Start Guide. Rev. 1.0

KNX R. Rain Sensor. Installation and Adjustment

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

Nokia Bluetooth Headset BH-800 User Guide Issue 2

Model RPM10 Laser Photo / Contact Tachometer with IR Thermometer Patented

PoE+ Extender Switch User's Manual. Rev W

READ FIRST! Universal Car/Air Adapter User Manual

Nokia Bluetooth Headset BH-102. Issue 1

User Manual Revision English

Nokia Bluetooth Headset BH /2

12 Volt 30 Amp Digital Solar Charge Controller

Nokia Bluetooth Headset BH-200 User Guide

Nest Learning Thermostat Installation Guide. Installation step-by-step

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Seven function digital multimeter

Transcription:

Original instructions Smile 11 AS-i Emergency stop with safe AS-i input node SAFETY AT WORK ABB Jokab Safety Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety

Read and understand this document Please read and understand this document before using the products. Please consult your ABB JOKAB SAFETY representative if you have any questions or comments. WARRANTY ABB JOKAB SAFETY s exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by ABB JOKAB SAFETY. ABB JOKAB SAFETY MAKES NO WARRANTY OR REPRESENTATION, EXPRESSED OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS, ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OR THEIR INTENDED USE. ABB JOKAB SAFETY DISCLAIMS ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED. LIMITATIONS OF LIABILITY ABB JOKAB SAFETY SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of ABB JOKAB SAFETY for any act exceed the individual price of the product on which liability asserted. IN NO EVENT SHALL ABB JOKAB SAFETY BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS ABB JOKAB SAFETY S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE ABB JOKAB SAFETY shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer s application or use of the product. At the customer s request, ABB JOKAB SAFETY will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE ABB JOKAB SAFETY PRODUCT IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PERFORMANCE DATA While every effort has been taken to ensure the accuracy of the information contained in this manual ABB JOKAB SAFETY cannot accept responsibility for errors or omissions and reserves the right to make changes and improvements without notice. Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of ABB JOKAB SAFETY S test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the ABB JOKAB SAFETY Warranty and Limitations of Liability. 2TLC172094M0201, rev. E 2 www.abb.com/jokabsafety

Table of Contents 1 Introduction... 4 Scope... 4 Audience... 4 Prerequisites... 4 Special notes... 4 Safety regulations... 4 2 Overview... 5 General description... 5 3 Connections... 6 4 Installation and maintenance... 7 Installation precautions... 7 Maintenance... 7 5 Operation... 8 Stop button:... 8 LED indication... 8 6 Model overview... 9 Dimensions... 9 7 Technical data... 10 8 EC Declaration of conformity... 11 2TLC172094M0201, rev. E 3 www.abb.com/jokabsafety

1 Introduction Scope The purpose of these instructions is to describe the emergency stop Smile 11EA AS-i, Smile 11EAR AS-i and the safety stop Smile 11SA AS-i, and to provide the necessary information required for installation and operation. Audience This document is intended for authorized installation personnel. Prerequisites It is assumed that the reader of this document has knowledge of the following: Basic knowledge of ABB Jokab Safety products. Knowledge of the AS-i system. Knowledge of machine safety. Special notes Pay attention to the following special notes in the document: Warning! Caution! NB: Danger of severe personal injury! An instruction or procedure which, if not carried out correctly, may result in injury to the technician or other personnel. Danger of damage to the equipment! An instruction or procedure which, if not carried out correctly, may damage the equipment. Notes are used to provide important or explanatory information. Safety regulations Warning! Carefully read through this entire manual before using the device. The devices shall be installed by a trained electrician following the Safety regulations, standards and the Machine directive. Failure to comply with instructions, operation that is not in accordance with the use prescribed in these instructions, improper installation or handling of the device can affect the safety of people and the plant. For installation and prescribed use of the product, the special notes in the instructions must be carefully observed and the technical standards relevant to the application must be considered. In case of failure to comply with the instructions or standards, especially when tampering with and/or modifying the product, any liability is excluded. 2TLC172094M0201, rev. E 4 www.abb.com/jokabsafety

2 Overview General description Smile 11EA AS-i is an emergency stop with a built-in dual channel safe AS-i input node. Smile 11SA AS-i has a similar dual channel safe AS-i input node, but is intended for use as a safety stop and therefore has a black pushbutton. Smile 11EAR AS-i works the same way as Smile 11EA AS-I but is designed to be mounted on the inside of a control cabinet, with the emergency stop button through the cabinet wall. The AS-i bus and the safety around it is specified by the two organisations AS-International Association and AS- Interface Safety at Work, and is described in the publication AS-Interface The Automatic Solution. Warning! Smile normally needs to be complemented with other safety functions such as interlocking guards etc. Refer to risk analysis. NB: The emergency stop should not be used as normal stop of the machine, only in case of emergency. 2TLC172094M0201, rev. E 5 www.abb.com/jokabsafety

3 Connections Smile 11EA/SA AS-i connections 1 3 5-pole M12 male connector 5-pole M12-connector: 1 ) AS-i + 2 ) Not used 3 ) AS-i 4 ) Not used 5 ) Not used M12 5-pole male seen from cable side M12 5-pole female seen from cable side Accessories for connection to the AS-i bus Type Article number Description AS-i T-connector with M12 2TLA020073R0000 Flat cable connector to M12 M12-C112 2TLA020056R2000 1 m cable, 5-pole, 0.34 mm2, M12 female + M12 male connectors M12-C312 2TLA020056R2100 3 m cable, 5-pole, 0.34 mm2, M12 female + M12 male connectors 5 x 0.34 mm 2 cable, screen with straight female and male M12 connectors. Screen connected to pin 3 (0 VDC) on male connector. Flat cable connector to M12 2TLC172094M0201, rev. E 6 www.abb.com/jokabsafety

4 Installation and maintenance All Smile 11 are supplied with 30 VDC from the AS-i bus. Recommended connection to the AS-i bus is through a flat cable connector to M12 (see figure to the left), making it possible to quickly and easily connect the unit to the yellow AS-i cable. Both Smile models can also be connected directly to the AS-i bus using only two cables (pin-1 and 3 of the M12-connector on the unit) according to Connections above. Installation precautions Mount Smile 11 using two M5 bolts, before attaching the M12-connector. Warning! All the safety functions must be tested before starting up the system. Maintenance Warning! The safety functions and the mechanics shall be tested regularly, at least once every year to confirm that all the safety functions are working properly. Warning! In case of breakdown or damage to the product, contact the nearest ABB Jokab Safety Service Office or reseller. Do not try to repair the product yourself since it may accidentally cause permanent damage to the product, impairing the safety of the device which in turn could lead to serious injury to personnel. Caution! ABB Jokab Safety will not accept responsibility for failure of the switch functions if the installation and maintenance requirements shown in this sheet are not implemented. These requirements form part of the product warranty. 2TLC172094M0201, rev. E 7 www.abb.com/jokabsafety

5 Operation Stop button: Push the button. An actuating force of 22 ± 4 N is required and the actuator travel is approximately 4 mm to latch. Turn the button clockwise to unlatch the button. LED indication The LED indication is identical on all models. LED in pushbutton: The LED indication is programmed individually in the PLC-program according to the table below. LED Indication Description Red Green ON OFF ON OFF Out bit 1 ON Out bit 1 OFF or Out bit 1&2 ON. Out bit 2 ON Out bit 2 OFF or Out bit 1&2 ON. AS-i LED and Fault LED in combination: LED pair by the M12-connector. AS-i (Green) Fault (Red) Description OFF OFF AS-i power missing ON OFF Normal operation OFF ON No data exchange with master FLASH ON No data exchange because address = 0 2TLC172094M0201, rev. E 8 www.abb.com/jokabsafety

6 Model overview Type Article number Description Smile 11EA AS-i 2TLA030052R0000 Emergency stop Smile 11SA AS-i 2TLA030052R0100 Safety stop Smile 11EAR AS-i 2TLA030052R0200 Emergency stop button, inverted mounting The Jokab Safety branded product with article number beginning with 2TLJ is fully compatible with the ABB branded product with article number beginning with 2TLA. Dimensions Smile 11 AS-i Smile 11 EAR AS-i NB: All measurements in millimetres. 2TLC172094M0201, rev. E 9 www.abb.com/jokabsafety

7 Technical data Manufacturer Address ABB JOKAB SAFETY Varlabergsvägen 11 SE-434 39 Kungsbacka Sweden AS-i data AS-i profile Addressing S-7.B.0 M12-connector Node address at delivery 0 Response time over AS-i bus 5 ms (+ response time of safety monitor) Power supply Operating voltage Total current consumption 30 VDC, AS-i bus. Tolerance 26.5 31.6 V DC. < 60 ma General Degree of protection Ambient temperature Size (H x W x L) Colour Actuating force Actuator travel Mechanical life IP65-25 +50 C 52 x 40 x 84 mm (+12.5 mm M12 contact) Base: Yellow Emergency stop pushbutton: Red Safety stop pushbutton: Black 22 ± 4 N Approx. 4 mm to latch > 50 000 operations Safety-related characteristic data and Conformity Conformity European Machinery Directive 2006/42/EC EN ISO 12100:2010, EN ISO 13849-1:2008/AC:2009, EN ISO 13849-2:2012, EN 60204-1:2007+A1, EN ISO 13850:2008 IEC/EN 61508-1 7 SIL3, PFDavr: 2.95*10-5, PFHd: 6.95*10-9 EN 62061 SIL3 EN ISO 13849-1 Performance level: PL e, category 4 MTTFd: High EN 60947-5-1 & -5 EN ISO 13850:2008 Certificates For E-stop button / Safety stop button For E-stop button / Safety stop button TÜV Nord (AS-i), Inspecta (Emergency stop) 2TLC172094M0201, rev. E 10 www.abb.com/jokabsafety

8 EC Declaration of conformity ABB JOKAB SAFETY Varlabergsvägen 11, SE-434 39 Kungsbacka, Sweden www.abb.com/jokabsafety 2TLC172094M0201, rev. E 11 www.abb.com/jokabsafety