RUBY #5 LIVE STEAM INSTRUCTION MANUAL



Similar documents
Coal fired steam locomotive CHARYBDIS

Wilesco D365, D366, D367, D368, D405, D406 D407, D409 Operating Instructions

Modular Locomotive System Instruction Manual for HBK5 Billy Body Kit

SIBIR MANUAL V110 KE. English page 5 RKE - 1D

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

Modular Locomotive System Instruction Manual for HBK8 George Body Kit

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

Bottom Loading Water Dispenser

infinity Burr Model #565 #560 Instructions Warranty Product Registration CONICAL Grinder 100W / 120V~ / 60 Hz

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

Installation Manual DIAPHRAGM WELL TANK

INSTANT HOT WATER RECIRCULATING SYSTEM

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

WHYNTER 21 Bottle Dual Temperature Zone Freestanding Wine Cooler

Installation Manual DIAPHRAGM WELL TANK

PNEUMATIC - HIGH PRESSURE FLAT-FORM HEAVY LIFTING BAGS

Boiler Preparation, Start-Up and Shutdown

VK-250 WARRANTY REGISTRATION FORM

TWO BURNER PROPANE CAMPING STOVE

COOLING SYSTEM Section Page

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

Peasouper Operator s Manual

Factory owners must ensure the boiler is:

BUGGY SETUP GUIDE. Volume GOKARTSUSA GY6 150, CN250. Buggy Setup Guide

Cooling system components, removing and installing

ACCUMULATOR INSTALLATION

Compressor Service & Maintenance Manual

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Operators manual Basic water heater

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Please keep this manual for f uture reference.

FX TYPHOON 12. Table of Contents

MODEL G300 BRAKE BLEEDER

Installation Instructions

Indirect-Fired Storage Water Heater Models WH-30 through WH-80 INSTALLATION AND OPERATING INSTRUCTIONS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

Wireless Indoor/ Outdoor Thermometer

STREAMLINE. Products for the Pure Water Cleaning Industry INSTRUCTION MANUAL

Lionel TrainMaster Command Control Crane Car Owner s Manual

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

tire inflator with pressure gauge

Nucleus Freedom BTE Rechargeable Battery (A25) and Nucleus Freedom BTE Recharger

Instruction Manual. Fun Pop 8oz. Popper

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Morco House Riverview Road Beverley HU17 0LD

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Hydraulic Transmission Jacks Operating Instructions & Parts Manual

User's Instructions. Alpha HE CB25/33 and HE SY25

MBA-MM-1040/10/13/1665 MULTI MEDIA FILTERS

Instruction Manual MODEL: VE V~, 60Hz, 1500W

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

SunMor SM-V30 Solar Water Heater Installation Manual

Cylinder Leak- Down Tester

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Hi-Spec. sustainable solutions under one roof HEATING HOT WATER VENTILATION. Warm Air Heaters. with System E-T & Basic Control USERS INSTRUCTIONS

Workshop Compressors CLASSIC Series

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Convoy Application For Motor Oil Limited Warranty

Installation Instructions / Warranty

RETRACTABLE LANDING GEAR

GENERAL KNOWLEDGE PRACTICE TEST

Instruction Manual. AWK-115S

TOBY DVR5 OIL CONTROL & SAFETY VALVE

FJ2. 2 Ton Trolley Floor Jack Assembly & Operating Instructions

cbperformance.com Please read this entire brochure prior to installing your CB Performance Products MAGNASPARK II distributor.

ROTOR LOADER OWNER S MANUAL

Installation Instructions / Warranty

Installation Instructions / Warranty

Some Criteria for Choosing a Steam Boiler for a Microbrewery

VOYAGER 570G. 744A Sprayer Control

Signature and ISX CM870 Fuel System

G234X-55 Conventional Gas Boiler

OTF Oil Fired Pool Heater

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

OPERATION OF Miniature Steam SLIDE VALVE STEAM ENGINES

PNEUMATIC PLANISHING HAMMER

In-Tank Fuel Pump Installation Instructions (Read Carefully Before Starting Project)

8 ton air/hydraulic long ram jack

SECTION G2: CABLE PROCESSOR MODULE MAINTENANCE

National Optical & Scientific Instruments Inc Landmark 35 Drive San Antonio, Texas Phone (210) Fax (210)

OUTDOOR GAS FIREPLACE USER GUIDE North America _2 EF

Davcron Concrete Agitator - Operations Manual

FIRE EXTINGUISHER TRAINING

Wireless Base Station Single and Multiple Headsets

Energy Efficient Operations and Maintenance Strategies for Boilers

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Oxy-Fuel Gas Welding. Given a functional oxy-fuel gas unit, instruction and demonstration of use, each student will be able to:

Installation Instructions / Warranty

3620 W 11th Streetб Houston, TX Telephone: sales@kellogg-american.com Website:

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Facility Operations Physical Safety Guidance Document

Fabric Replacement Top Installation Instructions

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Customer Support

SunMaxx Solar Filling Station Operating Instructions

MSD Pro-Billet Ready-to-Run Chevrolet V8 Distributor, PN 8360 Chevrolet 348, 409 Distributor, PN 8393

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

Transcription:

RUBY #5 LIVE STEAM INSTRUCTION MANUAL ACCUCRAFT COMPANY 33268 Central Avenue Union City, CA 94587 Tel: 510-324-3399 Fax: 510-324-3366 Email: info@accucraft.com Copyright 2009

Thank you for purchasing Accucraft Trains Live Steam Locomotive RUBY. Like other fi ne models from Accucraft Trains. RUBY has been designed to provide a lifetime of model railroading pleasure. RUBY is handcrafted in brass and is a precision piece of equipment. Like all fi ne equipment it must be properly maintained and cared for. Please read following directions before unpacking your locomotive. 1. Remove foam around the locomotive. Slide the inner box cover to the side, and open the inside cardboard box with a cutting knife. 2. Place taped locomotive on a fl at surface. Carefully cut the tape along the wood board side surface. Be sure to cut both sides of the wood board. Slowly lift the tape from the locomotive. Be very careful with small parts. Tape cannot be re-used to re-pack the model. Use new packing tape if necessary. Notice The information in this document is subject to change without notice. 1

Limited One-Year Warranty Accucraft Trains warrants that the mechanical components of its model trains will be free of any defect or malfunction under normal use for one year of the original purchaser and will remedy any mechanical components which prove to be thus malfunction. This warranty does not extend to : (1.) any damage to the locomotive resulting from any improper or unreasonable use of the locomotive or from any use of the locomotive in any manner other than that for which it is intended, (2.) any damage to the fi nish or casting of the locomotive, or (3.) any other damage (expect for damage resulting from a covered defect or malfunction) to the locomotive while in the possession of any consumer. RUBY #5 This warranty is given in lieu of all other express warranties. All implied warranties, including but not limited to the implied warranties of merchant ability and fi tness for a particular purpose shall expire one year from date of original purchase. (Note: the foregoing limitation on implied warranties is proper under Magnuson-Moss Warranty Act.) UNDER NO CIRCUMSTANCES SHALL ACCUCRAFT TRAINS BE RESPONSIBLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING IN REGARD TO ANY ACCUCRAFT PRODUCT. In order to validate this warranty, the Owner Registration Card enclosed with your locomotive must be completed and mailed within ten (10) days after purchase of the model. If warranty service is required after more than one year from the date of purchase, please request return authorization by phone or letter. Upon receipt of authorization, please send the locomotive, postage prepaid, with a check or money order for the amount of $30.00 in U.S. currency, (price applies to U.S. only) to cover return postage and handling. Also please write a letter explaining the nature of your problem and enclose it with the locomotive. 9 Features: Ready to Run All Brass Construction Radio Control Ready Piston-Type Slide Valves Fixed Eccentric Piston-Type Reversing Valve Pressure Gauge 2

General Information RUBY is a freelance, 1:20.3 scale, live-steam locomotive based on Baldwin practice. It has been designed to be both simple to operate and sophisticated enough to satisfy more experienced modelers. With proper care, RUBY should give years of service in the garden. Operating a live-steam locomotive is much different from running an electrically powered engine. It is a more hands-on, interactive experience. The locomotive must be periodically fueled, oiled, and watered. As supplied, RUBY is manually controlled, which means that you must actually drive the locomotive using the controls in the cab, just as you would a full-size engine. The performance of the engine is also unlike electric locomotives. RUBY should pull two to four standard-size freight cars on good, level track, which is about the same capacity as a full-size locomotive of this confi guration. Grades and sharp curves will diminish its capability. A good engineer will learn the engine s characteristics and idiosyncrasies over time to get the best performance and longest duration from it. Technical Specifications Scale: Gauge: Wheel Arrangement: Boiler: Boiler Fittings: 1:20.3 (15mm=1 0 ) 45mm 0-4-0T Single Flue, Gas Fired, Silver-Soldered Copper, Tested To 150psi (working pressure, 30psi) Safety Valve, Throttle, Pressure Gauge Shutting down: At the end of the day s run, close the throttle snugly. When cool, the safety valve should be loosened to relieve the vacuum that will be created in the boiler. This vacuum could pull oil from the lubricator into the boiler if the throttle is not closed. After a day s operation in the garden you ll probably fi nd that your engine has a coating of oil. This is steam-cylinder oil that has been exhausted from the stack. A simple wipe down with a dry cloth is all that s necessary to restore the engine to pristine condition. This is best done while the engine is still hot. Wipe any grit and excess oil from the wheels and running gear. The boiler can be drained of water, or not, as you will. Leaving water in the boiler will not harm it. The lubricator can also be drained and refi lled with steam oil in preparation for the next run. Notes on radio control: Although RUBY was designed as a manually controlled locomotive, there is no reason why radio control (R/C) cannot be fi tted with some ingenuity. A two channel radio is all that s necessary, one for the throttle and one for the reversing lever. The gas valve should always be controlled manually. Servos can be mounted to the fl oor of the loco and linked to the control arms. The reversing lever will have to be modifi ed so that it does not lock in position, but it must still have stops at either end of its throw for proper positioning of the reversing valve. You might be able to get away with one servo controlling only the reversing valve, but better control of the locomotive will be accomplished if the throttle is controlled, too. Fuel: Cylinder Lubrication: Cylinder: Valve Gear: Reversing Gear: Butane gas Displacement Lubricator In The Cab Fixed Cylinders, Piston-type Valves, Exhaust Through The Stack Fixed Eccentric Via Rocker Arms Piston-Type Reversing Valve Controlled From The Cab 3 8

Running With the engine on the track, and without a train, open the throttle. Because the cylinders are cold, the hot steam entering them will condense into water and be exhausted out the stack. Hot water squirting out the stack at the start of a run is normal. RUBY will need to be pushed back and forth until the cylinders heat up. You may need to exert a little downward pressure on the engine to get the wheels to turn, which will overcome the resistance of the water in the cylinders. Be sure to put the engine into reverse, using the lever at the right side of the cab, when pushing it backwards. When the cylinders have warmed a little, the engine will begin to show signs of life. After a few moments, it should take off on its own, moving away smoothly. Once the engine is running smoothly, a train can be coupled on and the run can proceed. Since all of RUBY s functions are controlled from the cab, it can be driven like a full-size loco, meaning that you ll have to stay with the engine throughout the run if you want to change its speed or direction. If you have a suitable track, the engine can be left to run on its own at a steady speed until the fuel runs out. As the gas tank in the cab warms, you may fi nd the engine picking up speed. Simply turn the gas down a little and throttle the steam back. This is all part of learning how to get the best performance from your engine. Safety For your safety, there are certain rules that should be observed, as follows: 1. The safety valve has been set at the factory to release at 30 pounds per square inch of pressure. Never tamper with the safety valve. 2. The fi ring system has been designed to use butane gas only. Never use any other gas (including propane or butane/propane mix), as the storage pressures can reach unsafe levels. 3. Always refuel the engine away from other working live-steam locomotives. The fuel fi lling system allows a small amount of the gas to bleed off as the fuel tank is being fi lled. A passing engine can ignite this bleed-off gas, causing a potentially hazardous situation. 4. When lighting up, light the match fi rst, then turn on the gas. 5. A steam engine gets hot. Be careful. Lift the Forney by holding the end steps when hot. A word on speed: Little engines like RUBY were rarely run at more than 5 or 10 mph. If you imagine a little person running alongside, that is about the right prototypical speed. When run at this slower speed, steam and fuel consumption are lower, which increases the run time. RUBY was designed to run out of fuel before running out of water, thus preventing damage to the boiler. Care should be taken never to run the boiler dry. When the run is over and the locomotive has cooled somewhat, it can be lubricated, rewatered, and refueled for the next run. 7 4

Preparing the engine A steam-locomotive engineer goes through a lighting-up ritual every time the engine is to be run. It is good to follow the same routine each time so that nothing is overlooked. 1. Oil all external moving parts of the engine with a high grade, lightweight machine oil like 3-in-1. 2. Remove the cab roof. Drain any water from the displacement lubricator in the cab and fi ll the lubricator to the top with proper steam cylinder oil. This lubricator makes sure the cylinders and valves are lubricated inside. As the steam passes through it, a small amount will condense into water. This water will sink to the bottom of the lubricator, forcing a similar quantity of oil into the steam line and thus to the cylinders. 3. Fill the boiler (make sure the throttle is closed). A properly fi lled boiler will have 80ml of water in it. Do not fi ll the boiler full to the top. There must be room for the steam above the water level. If there is water in the boiler already and you don t know how much, fi ll the boiler to the top, then remove 30ml. Use only distilled water in your engine s boiler. Tap water contains minerals that will leach out and ultimately affect the performance of the engine. Filler Plug Burner Butane Filler Valve Firing up RUBY s burner resides at the back of the fl ue inside the boiler. Open the hinged smokebox door at the front of the engine and you ll be able to see the fl ue. To light up, strike a match and hold it at the open smokebox door while simultaneously opening the gas valve in the cab very slowly until the gas ignites. You should hear the gas coming into the burner. Opening the valve too wide or too fast may blow out the fl ame or cause the fi re to burn in the smokebox. The fi re should fl ash back into the back of the fl ue with a quiet pop. If it wants to burn in the smokebox or in the forward part of the fl ue, slowly close the gas valve until it fl ashes back to the burner. Don t let the fi re burn in the smokebox your engine will not run as it should and maybe damaged. The fl ame should be bright blue and should burn steadily. The object is to run the burner at the lowest setting possible to operate the engine, thereby increasing the effi ciency of the engine and the duration of the run. You ll get the hang of this with practice When the safety valve blows, you ll know that pressure is up to working level. This should take 5-8 minutes or so. The air temperature will have an effect on this. It will take longer on cold days and less on hot days. Butane gas turns to non-pressurized liquid at 32 F, so the engine may have diffi culty on very cold days, unless it is fi red up indoors. Lubricator 4. Finally, add fuel. Butane gas can be purchased at the grocery store or at a tobacconist s as cigarette-lighter refi lls. These come with a nipple suitable for the fi ller valve on the RUBY s gas tank. Butane can also be purchased in larger containers at camping-supply stores, but these cans will require a special adapter for fi lling. Simply press the nozzle of the butane canister hard onto the fi ller valve. You will hear the gas transferring and see a little gas bleeding out of the valve. When the tank is full, the gas will begin to splutter and much more gas will escape the valve. When the gas tank is full and the cab roof 5has been replaced, you are ready to fi re up the engine. 5 6