SHOWERS MIXER SI-IOWER GUIDE. Opi!3r~tiqn & Maintenance



Similar documents
Installation & User Guide BASIN AND BATH PILLAR TAPS THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 1

ACE. PIVOT AND BI-FOLD DOOR Installation and User Guide. These instructions must be left with the user W2-D

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Design Utility Lever Thermostatic Bath Shower Mixer

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

Cadet Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference

Thermostatic bar showers. Troubleshooting and maintenance

Colonial Tap Range. Installation Instructions & User Guide. Please keep these instructions for future reference and request of replacement parts

Chill 4 Hole Bath Shower Mixer

Artisan Thermostatic bath shower mixer. Fitting Instructions & Contents List

PLUMBING CARE AND REPAIR

V10 THERMOSTATIC SHOWER VALVE PRODUCT MANUAL

COASTLINE QUADRANT ENCLOSURE. Installation / Maintenance Instructions Rev

Mira Extra Bath and Thermostatic Shower Control

Artisan Thermostatic Bath Shower Mixer

Liquorice Kitchen Sink Tap

Safe Touch TMV3 Thermostatic Shower ST10010CP

Almond Kitchen Sink Tap

Apricot Kitchen Sink Tap

Installation guide Nordic mixer taps. Before installing read this guide first

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Installation Instructions / Warranty

INSTALLATION INSTRUCTIONS BL-8704

STABITHERM INSTALLATION & SERVICE BOOKLET

INSTALLATION INSTRUCTIONS MK-8704

Almond Kitchen Sink Tap

Apricot Kitchen Sink Tap

Installation Instructions S

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

Installation Instructions

Important Information

REDRING POWERSTREAM-ECO UNVENTED INSTANTANEOUS WATER HEATER. Installation and User Guide

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Installation Instructions / Warranty

Thermostatic. THERMOSTATIC POWER SHOWER Installation and User Guide. These instructions are to be left with the user 1

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

IMPORTANT INFORMATION

BATHROOM FAUCET ITEM # MODEL # H2. Francias / Español p. 9 ATTACH YOUR RECEIPT HERE

PHOENIX TAPWARE. Gloss. Shower/Wall Mixer RRP: $ Product Code: Available Finishes: GS780. Chrome MATCH WITH...

GLOSS SOAP DISH PRODUCT CODE: FINISH: GS895 CHROME CONTEMPORARY DESIGN PHOENIX WARRANTY STYLISH PREMIUM CHROME FINISH MATCH WITH...

Close Coupled & Back To Wall WC Saintaryware. Fitting Instructions

Installation and User Instructions Aquarius Undersink Vented Water Heaters Models: AU7/3, AU7/1, AU10/3, AU10/1.

INSTALLATION INSTRUCTIONS

Installation Instructions / Warranty

Shower Handbook (Also covers 650 chrome variant)

ALTO EV. Installation Instructions Thermostatic Bar Shower Valve

Lenntech psi End port pressure vessels 2.5. User s Guide to: Phoenix Vessel Technology Limited. Model number: 1503

Getting the best from your urn

CW-4622 INSTALLATION INSTRUCTIONS CB-4622 RISER KIT TO SUIT BLACK LEVER EXPOSED VALVES & BATH/SHOWER VALVES

VW GOLF Mk4 TDI FRONT MOUNTING INTERCOOLER INSTALLATION INSTRUCTIONS

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

Visage. Digital. Exposed with adjustable height head. Visage Digital exposed installation instuctions page 1

Folding Bath Screen Instruction Manual

MODEL VG08008 CONTENT PACKING LIST / TOOLS NEEDED PANEL DIMENSIONS FITTINGS / TECHNICAL DATA WALL/CORNER INSTALLATION CARE AND TROUBLE SHOOTING

Installation Instructions

Assembly and instructions

Installation Instructions and User Guide

Model No: VS SAFETY INSTRUCTIONS VS INTRODUCTION & APPLICATIONS VS CONTENTS. 2.1 Introduction. 2.

Installation Instructions

4-600, 1000 psi. User s Guide to: Phoenix Vessel Technology Limited. End port pressure vessels Model numbers: 1386, 1384.

Elson 10/15L Unvented Water Heater

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Stainless Steel Single and Dual Circulation Kits

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

BASYS INSTALLATION INSTRUCTIONS FOR ELECTRONIC CAPACITANCE SENSING LAVATORY FAUCETS EFX-3XX Pedestal, Sensor Activated Lavatory Faucets

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

FAUCET SPECIFICATIONS. Vessel Bathroom Faucet Model VG03023 MODEL VG03023

Installation Instructions

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

MP-4V Heavy Duty Riveter / 39048

TWO-WAY DIVERTER WITH THREE-WAY HAND SHOWER

Beautifully Traditional

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

Please read and keep these instructions. Run water through your machine before first use

THE BOILING WATER DISPENSER INSTALLATION & OPERATING INSTRUCTIONS

Triac Printed Circuit Board Replacement

AIRE Thermostatic bath shower mixer Installation and operating instructions

Rebuild Instructions for and Transmission

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Troubleshoot resources for homeowner

ATTENTION This is a general warning that failure to follow instructions could result in poor functioning of the unit.

SHOT BLAST CABINET MODEL NO: CSB20B

Machine needle shut-off nozzle type HP

M A N U A L

Wetroom Panel (Concealed Fix)

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

ferroli Boiler Replacement Optimax HE- Modena HE

Back Pack Sprayer. Operator's Manual MODELS MS - 40 MS - 50

INSTALLATION INSTRUCTIONS FOR VW MK5

This instruction is valid for all ACD pump models shown on page 2

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Assembly and Usage Instructions

SELECTION, APPLICATION AND MAINTENANCE

Front brakes (FN- 3), servicing

2006 HEADSHOK Service Video #1

not appearance. ADHESIVE SYSTEMS CORIAN As an integral part of its sheet and shape products, DuPont has developed a special adhesive.

OWNER S MANUAL. FOOTWORKS tm Faucet Controller. Foot Operated Faucet Control Valves for Commercial Sinks

SHOWER WATER HEATER MODEL BS 35 / 45 / 60 BS 35 E / 45 E / 60 E OPERATION AND INSTALLATION INSTRUCTIONS

Transcription:

SHOWERS." " 723 MIXER SI-IOWER GUIDE Opi!3r~tiqn & ;- Maintenance

1. Turn flow control knob until the desired force of water is obtained. 2. Turn the temperature knob in the direction of the red mark (No.9) for warmer wa ter and in the direction of the blue mark (No. 0) for cooler water, until the desired temperature of water is obtained. If difficulties are experienced contact our service office. please finisll Temperature knob Sovereign golden finish is softer than chrome and its abrasive resistance much less, when cleaning or using tools during maintenance extra care must be taken. Clea~ning Sovereign golden finish should be cleaned with a soft cloth and if necessary, a mild washing up detergent or soap solution and then rinsed and rubbed dry. Many household cleaners contain mild abrasives or chemicals and should never be used for cleaning chrome plated, sovereign finish or plastic fittings. 1.

If a new Mira 723 mixer shower fails to operate satisfactorily it is usually the result of incorrect installation and the installer should be consulted. Refer to Installation notes on page 13. If the mixer has operated for a time and no longer performs acceptably or if it is leaking the mixer may need servicing. The dismantling procedure which follows will assist you with maintenance. Our experience has shown that, due to the simplicity of design, the average user is capable of renewing '0' seals and cleaning or replacing internal parts when necessary. You may if you wish, choose to engage the services of a suitable qualified person locally. You will need A screwdriver A spanner or wrench Kettle descalent Service pack (if valve is leaking) Silicone lubricant The service pack (part No 936 59) contains all seals and silicone grease necessary to service the valve. To check the complete contents of the pack see illustration on page 12. Spare parts are available from Caradon Mira, when ordering please quote model of mixer shower, part number and description of items required. Isolate water supplies to shower. Open flow control to release pressure in system. islllantlillg Using a screwdriver, gently lever off the concealing cap. 2.

Control knob Remove flow control knob screw, pull off flow knob. Screw Gently prise off circlip, remove flat washer and wavy washer, pull off temperature knob. Circlip Recessed models only - gently lever off concealing plate. 3.

Remove 3 gears and gear carrier. Gear carrier Undo 2 screws and pull off the gear housing, remove the cover shroud. Cover shroud Gear housing Undo 4 cover screws and remove cover. Note! Recessed models When cover is removed some water will run from body. Channel water away or soak it up with absorbent material. Pull the temperature spindle, this action will remove the temperature spindle, the thermostat coil and the port sleeve as a complete assembly. Note! In hard water areas scale build up may cause more resistance when removing this assembly. Sleeve Temperature spindle 4.

Head Nut Use a spanner to loosen the headnut on the port assembly. Deflector Pull the port assembly from the valve body (it may be easier to loosely fit the flow knob and screw, to provide extra leverage). Remove deflector from valve body. Unscrew the headnut and dismantle the port assembly into it's individual components. Port Assembly "",-/, : ~"'''' 0 ~)~..'.. ~:.. :... ~' /C: Fl. wv /'1 1 " Pis ton ~ 5. Flow ~ spindle Clean all metal components proprietory inhibited scale solvent, ie Kettle descaler. Follow manufacturers instructions. Do not use abrasives or acid solutions. in a

Note!! Do not allow the solvent to come into contact with bathroom fittings and surfaces. Ifnecessary instruction replace the seals, the leaflet in the service pack indentifies individual seals (Service pack 936 59). 00 00 00 o o o o Silicone Lubricant To assist re-assembly, lightly smear all '0' seals and piston/spindle threads with a silicone based lubricant (supplied with service pack). Flow spindle Screw the flow spindle fully into the flow piston. Fit the small thrust washer on to the spindle. Small thrust washer Push the piston/ spindle assembly into the headnut. Engage the hexagon fully. Head nut 6.

Screw the headnut loosely into the port assembly. Deflector Fit the deflector into the valve body. Locate it's cut-out over the pin. Push the port assembly fully into the body. Locate cut-out over the pin. Fit the larger thrust washer over the port assembly spindle. Thrust washer Use a spanner to tighten the headnut. Do not overtighten! as this may damage the locating pin. 7.

Fit the temperature spindle into one end of the thermostat coil. Locate the coil tab into the slot in the spindle. Fit the port sleeve into the other end of the thern10stat coil. Locate the coil tab into the slot in the sleeve. Temperature spinel Ie Push the sleeve/coil/spindle assen1bly over the port assembly. Ensure that the large cut-out on the end of the sleeve is located over the body pin. Turn the temperature spindle to check that the pin is lin1iting the free rotation of the sleeve. Fi t the cover on the valve seal over the boss body. Fi t the largest thrust washer over the temperature spindle. 8.

Refit the cover and secure it with 4 cover screws. Ensure that the 2 holes in the front face of the cover are horizontal. Tighten cover scrhwsfully. Turn on the water supplies and check for leaks. Temperature indicator Refit the cover shroud, ensure that the temperature indicator is at the top. Fit the gear housing onto the end of the cover, Locate the 2 lugs into the cut-outs in the cover shroud. Secure the gear housing with 2 screws. On recessed models refit the concealing plate over the cover shroud. Ensure that it is located over the j retaining clips. Fit the gear carrier onto the splines of the temperature spindle, then fit the 3 gears onto the gear carrier.

Maxill1llJIl tell1p el~atllr'(~ Ensure that there is an adequate supply of hot water available. Fit the temperature knob to the valve with No 5 adjacent to the indicator on the cover shroud. (Do not fit the washers and circli p at this stage.) Fit the flow knob and secure it with the screw. Note! for correct operation of the flow control and to prevent leakage the screw MUST be fitted. Turn the shower on and check the temperature at the sprayhead. Toincrease the temperature turn the temperature knob towards No 9, to reduce temperature towards No O. turn it Note! If the required Maximum temperature cannot be achieved, remove the flow knob and screw, pull off the temperature knob, and refit it at No 5 so that further movement in the required direction is possible. 10.

When the required maximum temperature is reached, turn the shower off and remove flu\v knob and screw. Indica tor Remove the temperature knob and refit it so that No 9 is adjacent to the indicator on the cover shroud. Fit the wavy washer, the flat washer and the circlip to secure the temperature knob. Refit flow knob and secure it wi th the screw. Fit concealing cap to flow knob.

Parts Cover Trim Concealing Flow Gear Inlet Temperature 641I List 56 connector pack Control Knob assembly shroud 24 21 20 25 (f) * 22 23 19 Deflector -723L Pillar Flow Thermostat Support Cap Cartridge Part Description Set knob -723-931 piston/spindle and No 723L 34 sleeve coil 80022 07965 92050 10719 91681 03297 931 90067-723L 33 902 92720 90066 282 019 38 26 Backplate 'models) assembly assembly 55541 93713 i Service 11 27, 28: 29, Mounting Clip Seal (3) ('B' ('B' models) bracket models) 801 28007 802 61822 805 assembly 20 73 579 36 30 Concealing plate ('B' 553 models) 35 076 11-723 70 11 55 80 31 Building ('B' shroud 8079 '. 64 17 63 32 Pipe concealing plate 902 089 933 93669 65 090 98 59 95 uv \f Screw pack : Item No 30 31 29 t Part number 3A is only available from your local stockist 12.

#11 Layout and sizing of pipework 1 " Isolating No I Hot Supply Conveniently formpipes of flow situated control be flushed isolating should II Installations GAS I 723/723b*1I must comply withto ~ I WATER I HEATERS Other I Other except the Undertakers The intended Local conjunction cold Mira figures Water when 723. toquoted use with Authority Bye-Laws. used any fully for with form each gas of Water situation water 111 v P2310. be further exists ColdII ', cistern I Sheet conditions, used of Schematic *Minimum Absolute 0.9 0.6 required sprayheads installed. will P2181, orinformation adepend more athe booster The and required. type forceful Pump type onsee hot metres ~ II metre are draw of based minimum plumbing 15mm = draw offs offs head 4.6litre/min 5.7litre/min on pipe and pump layout the on runs of Data Guide For shower number site each pump not maysupply. exceeding 5 T 13.

Mira 723 Dimensions I 153 I Mira 723b Dimensions 15mm Temperature compression/1/z" 723b Thermostatic Yes Recessed 30.06 10 Flow Temperature BS (IRN UK Full maximum bar bar15mm 1/:/' maximum 1415 "WFBS" cold 1/:/' control Flow BSP 103, Full Surface mixer BSP Thermostatic to part cold 0.06 1415 104 temperature control compression preset 3female knob control shower Yes Listed bar mounted 2to and knob 723 part preset 111) knob 2 1) n notes Temperature Minimum (Page 4) pressure 14.

Guarantee of Quality Mira Showers guarantee products against any defect of materials or workmanship for one year from the date of purchase (2 years for Mira Select and 3 years for Mira Excel ranges). To validate the guarantee, please return your completed registration card. Within the guarantee period we will resolve defects, free of charge, by repairing or replacing parts or modules as we may choose. To be free of charge, service work must only be undertaken by Mira Showers or our approved agents in Northern Ireland and Republic of Ireland. Service under this guarantee does not affect the expiry date. The guarantee on any exchanged parts or product ends when the normal product guarantee period expires. Not covered by this guarantee: Damage or defects arising from incorrect installation, improper use or lack of maintenance, including build-up of limescale. Damage or defects if the product is taken apart, repaired or modified by any person not authorised by Mira Showers or our approved agents. This guarantee is in addition to your statutory and other legal rights. Before using your shower Please take the time to read and understand the operating and safety instructions What to do if something detailed in this manual. goes wrong If when you first use your shower it doesn't function correctly, first contact your installer to check that installation and commissioning are satisfactory and in accordance with the instructions in this manual. We are on-hand to offer you or your installer any advice you may need. Should this not resolve the difficulty, simply contact our Customer Services who will give every assistance, and if necessary arrange for our service engineer to visit. If later the performance of your shower declines, consult this manual to see whether simple home maintenance is required. Please call our Customer Services to talk the difficulty through, request service under guarantee if applicable, or take advantage of our comprehensive After-Sales service. As part of our quality and training programme calls may be recorded or monitored Mira Showers Kohler Mira Ltd Cromwell Road, Cheltenham GL52 5EP. Mira is a registered trade mark of Kohler Mira Limited. The company reserves the right to alter product specifications without notice. After Sales Service Our Customer Services Team is comprehensively trained to provide every assistance you may need: help and advice, spare parts or a service visit. Spare Parts We maintain an extensive stock of spares, and aim to have functional parts available for ten years from the date of final manufacture of the product. Spares can be purchased from approved stockists or merchants (locations on request) or direct from Customer Services. Spares direct will normally be despatched within two working days. Payment can be made by Visa or Mastercard at the time of ordering. Should payment by cheque be preferred a pro-forma invoice will be sent. Note! In the interests of safety, spares requiring exposure to mains voltages can only be sent to competent persons. Service Our Service Force is available to provide a quality service at a reasonable cost. You will have the assurance of a Mira trained engineer/agent, genuine Mira spares - and a 12 month guarantee on the repair. Payment should be made directly to the Service Engineer/ Agent, using Visa, Mastercard or a cheque supported by a banker's card. To contact us: England, Scotland & Wales Mira Showers Customer Services Telephone: 0870241 0888 8.30am to 5pm Working days (4.30pm Fri) 8.30 am to 12.30pm Saturday E-mail: Mira_technical@mirashowers.com Fax: 01242282595 By Post: Cromwell Road Cheltenham Gloucester GL52 5EP For Customers in Northern Ireland Wm H Leech & Son Ltd Telephone: 028 90449257 - Mon to Fri 9 am-5pm Fax: 02890449234-24 hours Post: Maryland Industrial Estate Ballygowan Road Moneyreagh, Co Down BT236BL For Customers in Republic of Ireland Modern Plant Ltd Telephone: Dublin 01 4591344 - Mon to Fri 9am to 5pm Fax: Dublin 01 4592329-24 hours Post: Otter House Naas Road Clondalkin Dublin 22 OSII'.fi~,... P2383/5 (H) Kohler Mira Limited, December 2002 FM 14648 003