Sterile Acrodisc Syringe Filters



Similar documents
Diafiltration: A Fast, Efficient Method for Desalting, or Buffer Exchange of Biological Samples

Efficient Multi-Well Protein Purification Strategies

Acrodisc PSF Syringe Filters

Durapore. High Throughput Flow Rates. Durapore 0.2 µm hydrophilic

Lenntech Tel Fax

Durapore 0.45 μm Hydrophilic Filters

Streamlined Purification of Plasmid DNA From Prokaryotic Cultures

Using a filter should not be difficult either.

Filtration Products for Air Monitoring and Sampling

IV and Fluid Filtration Products for OEM Health Care Devices

Pall in the Brewery (more value per hectolitre) DE Free Clarification FB1795

Lenntech Tel Fax

Application Note USTR 805. Steam Sterilization of Pall Filter Assemblies Utilizing Replaceable Filter Cartridges

LifeASSURE 020SP. Series Capsules & Cartridge Filters. Sterilising Grade Nylon 6,6 Membrane Filter

Application Note. USD 2995 (a) High Throughput Regeneration Study on MEP HyperCel Mixed-Mode Sorbent on ScreenExpert RoboColumns u

TR40 Sterilizing Filtration of Gases A comparison with TR26 Sterilizing Filtration of Liquids

ENrich SEC 70 ENrich SEC 650 High-Resolution Size Exclusion Columns Instruction Manual

[ Care and Use Manual ]

Assembly and Installation Procedures

Acrodose PL System. Enhanced Patient Safety. A New Platform for Pre-storage Pooling and Testing of Leukoreduced Whole Blood Derived Platelets

Overview. Optimizer Bulk

Viresolve. NFP Filter. Lenntech. Fast, reliable parvovirus removal. Membrane Type. Filter Formats. Rapid, Reliable

FILTRATION SOLUTIONS PhARmAceUTIcAL manufacturing FILTRATION SPecIALISTS

Resolute FM mm I.D. Chromatography Columns for Pilot or Production Use

Total Cleanliness Management for the Automotive, Industrial Manufacturing, and Aerospace Industries

Pall Aria Integrated MF/RO Systems for Cost-Effective Treatment of Sea and Brackish Waters

SEFAR PHARMA GMP solutions Life Science

Clinical and Laboratory Practices Workshops. Helping to improve laboratory skills and the quality of care in resource-limited settings

Cadence Acoustic Separator

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

Thermo Scientific Nunc Products for InVitro Fertilization. security, safety and reproducibility. for your valuable. samples

TUBING LEADER IN FLUID MANAGEMENT

Application Note USD3013. Monoclonal Antibody Production in Suspension CHO Culture Using Single-Use PadReactor Mini Bioreactor

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Thermo Scientific ClinQuan MD Software For In Vitro Diagnostic Use. Confidence in Results With Data Integrity

Thermo Scientific Capitol Vial Drugs of Abuse Products. The tools to create and maintain. a safe and drug free environment

LC-MS/MS Method for the Determination of Docetaxel in Human Serum for Clinical Research

USD Pall Filter Housings for Depth Filter Modules. Stainless Steel Housings designed for the Biopharmaceutical Industry

Thermo Scientific SOLAµ SPE Plates Technical Guide. Consistent excellence. for bioanalysis

Corning Spin-X UF Concentrator Selection and Use Guide

Thermo Scientific Nalgene Analytical Filtration Products

Membranes for Transfer and Immobilization BioTrace, Biodyne, FluoroTrans and UltraBind Membranes

Allegro TM Single-Use Tangential Flow Filtration System

POLYMER SEGMENT FILTERS FOR THE MANUFACTURE OF HIGH PERFORMANCE FIBERS, FILMS, AND RESINS

Use of Acrodisc Syringe Filters for Analytical Sample Preparation; Including HPLC and Dissolution Testing

Total Chromatography Solutions. Pall Filter Modules and Capsules with Seitz Depth Filter Sheets

Mustang Q XT Chromatography Capsules

Validation Guide. USTR 805j (5) Steam sterilization of Pall filter assemblies which utilize replaceable filter cartridges

INSTRUCTIONS Edition AC

Keysight Technologies How to Choose your MAC Lever. Technical Overview

LifeASSURE PFS. Series Capsules & Cartridges Sterilising Grade PTFE Membrane Filters. 3M Purification. Product brochure

Cross Flow Filtration Method Handbook

Image Lab Software for the GS-900 Densitometer

Centrifugal Devices for Ultrafiltration & Microfiltration

Ultipleat High Flow Filter System

Monoclonal Antibody Production: Building the Platform. Andrew Clutterbuck Eden Biodesign Ltd.

41 T Korea, Rep T Netherlands T Japan E Bulgaria T Argentina T Czech Republic T Greece 50.

Sterile ReadyToProcess Hollow Fiber Cartridges Instructions for Use

Melt Blown Filter Technology

M EMBRANE FILTERS

Thermo Scientific Prelude SPLC System FPO. Making LC/MS accessible. to clinical research and toxicology labs

Customer Application Brief. Filtration Processes Applied in Therapeutic Monoclonal Antibody Production. Bioprocess, Biologicals, & Pharmaceutical

Keysight Technologies Using Fine Resolution to Improve Thermal Images. Application Note

Mine Water Treatment Solutions for Discharge and Re-Use

Thermo Scientific Dionex AS-AP, AS-DV, and AS-HV Autosamplers. Automation, sample preparation. Autosamplers for Ion Chromatography

Gas Chromatography Liner Selection Guide

Global Real Estate Outlook

To meet the demands of a high-purity deionized (DI) water system, filters must:

Fast, Reproducible LC-MS/MS Analysis of Dextromethorphan and Dextrorphan

Data Center.

AkzoNobel Aerospace Coatings. Aerowave. Series Next generation structural waterborne coatings

Life Sciences USD High Purity Water Systems for the Biopharmaceutical Industry. Improving security, flexibility and operation costs

ProteinChip Energy Absorbing Molecules (EAM)

SILASTIC 9161 RTV Silicone Elastomer

Food and Beverage Food & Beverage

Laboratory Filtration Catalog

Agilent 4339B/4349B High Resistance Meters

TECHNICAL BRIEF. Microfluor II Filter Cartridge Integrity Testing. Introduction. Forward flow integrity test. 1. Definition

Reporting practices for domestic and total debt securities

10.0 FPSB s Country/region-specific Trademark Symbols and Legal Notices

LifeASSURE PFS Series Filter Cartridge Integrity Testing

HPLC Analysis of Acetaminophen Tablets with Waters Alliance and Agilent Supplies

Chapter 28: High-Performance Liquid Chromatography (HPLC)

Cell Culture Roller Bottles

Cool Savings! Chill &Conserve! Recirculating Coolers / Chillers

USD2555a. Palltronic. Flowstar IV. Filter Integrity Test Instrument and MUX Extension

THE GLOBAL LEADER FOR LIMS and ELN SOLUTIONS

GLOBAL EDUCATION PROGRAM

Guide to Reverse Phase SpinColumns Chromatography for Sample Prep

Pharma&Biotech. Endotoxin Challenge Vials Endotoxin Indicator for Depyrogenation. Translated versions available at

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Make the invisible visible! SENSORS WITH EXCELLENT BACKGROUND SUPPRESSION

Corning Filtration Guide. Innovative Products for Filtration and Ultrafiltration

Armaturenwerk Hötensleben GmbH. AWH-Connect

NI USB-6008/6009 OEM USER GUIDE

Transcription:

Product Data Sterile Acrodisc Syringe Filters Superior performance in a variety of sterile laboratory filtration applications Choose from a variety of membrane types, pore sizes, and effective filtration areas to meet your specific application requirements. Filter sizes accommodate sample volumes from < 2 to 2 ml. Pall products from our UpScale SM Program simplify scale up and reduce validation; no need to change membrane materials during transitions to pilot or full-scale production. Improve throughput of viscous or particulateladen solutions with built-in prefilter. Product Selection Consider Scaleability Filters that contain consistent materials of construction provide greatly simplified filter qualification and easier transitions from R&D to pilot to full-scale production. The filters in Pall Corporation s UpScale Program incorporate scaleable membranes and materials of construction to assure consistent results, whether you are using syringe filters (less than 1 ml) or larger-capacity capsules and cartridges (up to 5 L). The UpScale Program offers worldwide product availability and validation, troubleshooting, and technical support. This icon indicates membranes and products that are scaleable and included in Pall s UpScale Program. Consider Filtration Volume The appropriate filter size is determined primarily by the volume being filtered. However, total throughput (capacity) of a filter depends on the characteristics of the fluid being filtered, such as the extent of microbial contamination, viscosity, and particulate load. For small-volume or expensive samples, hold-up volume (sample loss) can be a concern and a smaller filter should be used. The volume recommendations below are intended as a general guide in selecting the most appropriate filter. Sample Filter Volume (ml) Size (mm) up to 1 13 < 28 µl up to 1 25 < 7 µl up to 15 32 < 1 µl up to 2 37 < 1 µl up to 3 5 < 3 ml Consider Fluid Characteristics The characteristics of the fluid being filtered are extremely important when evaluating the membrane to be used for filtration. Pall Life Sciences offers sterile Acrodisc syringe filters in the following membrane types: Fluorodyne II Membrane For high flow rates and low protein binding. Not recommended for use with some ethers. Nylon Membrane Used in our DMSO-Safe Acrodisc syringe filter. Posidyne Membrane Enhances bioburden and pyrogen removal from aqueous solutions. Supor Membrane For high throughputs, fast filtration, and low protein binding. Not recommended for use with some ketones. Ultipor Membrane Provides broad solvent and chemical compatibility, and low extractables. Industry standard for pharmaceutical filtration. Versapor Membrane Economical choice for clarification.

Sterile Acrodisc Syringe Filters with Supor Membrane Universal life science membrane with low protein binding. Outstanding flow rate and throughput performance. The range of available filter sizes allows you to optimize filtration efficiency without compromising sterilization performance. Use these high-performance filters for prefiltration/clarification of viscous solutions, and sterilization of buffers and culture media. Choose:.1 and.2 µm pore sizes provide sterilization of small volumes of buffers, culture media, and additives. Acrodisc PF and Serum Acrodisc syringe filters with unique built-in prefilter for increased throughput of viscous or particulate-laden solutions..1 µm pore size filters for reduction of mycoplasma..45,.8, 1.2 and 5 µm for prefiltration and/or clarification. Performance Acrodisc and Acrodisc PF Syringe Filters with Supor Membrane Built-in prefilter enhances throughput of viscous, particulate-laden, or proteinaceous solutions. 1% Calf Serum (ml) 1 8 6 4 2 B. diminuta (ml) 5 4 3 2 1.2 μm PF 5 1 15 2 Time (sec) 5 1 15 2 Time (sec) Acrodisc and Acrodisc PF syringe filters with.2 µm Supor membrane were challenged with calf serum and a bacterial culture (1 7 cfu/ml) at a constant pressure of 1.4 bar (14 kpa, 2 psi). Membrane Filtration Throughput.2 µm Rated Membranes 125 I BSA Protein Transmission Through 25 mm Acrodisc Syringe Filters Volume Filtered Prior to Clogging (ml) 15 12 9 6 3 145 86 35 Supor 2 Membrane P =.7 bar (7 kpa, 1 psi), EFA = 9.62 cm 2 5% Dextrose 2.5% TSB 1% BSA TSB = Trypticase Soy Broth BSA = Bovine Serum Albumin Percent Transmission 1 8 6 4 2 Supor Membrane 5 ng/ml 25 ng/ml Posidyne Membrane (positive control) Error bars indicate standard deviation, n=3

Specifications Filter Media: Supor membrane (hydrophilic polyethersulfone) Serum Acrodisc Prefilter Media: Binder-free borosilicate glass Acrodisc Housing: 13 mm: Polypropylene 25 and 32 mm: Modified acrylic 37 mm: Polypropylene Serum Acrodisc Housing: ABS 13 mm: 1. cm 2 25 mm: 2.8 cm 2 32 mm: 5.8 cm 2 37 mm: 7.5 cm 2 Female luer lock inlet, male slip luer outlet 13 mm: 28 µl 25 mm: 7 µl 32 and 37 mm: 1 µl 55 C (131 F) ml/min at 3.1 bar (31 kpa, 45 psi).1 µm, 25 mm: 35.1 µm, 32 mm: 1.2 µm, 13 mm: 22.2 µm, 25 mm: 175.2 µm, 32 mm: 49.45 µm, 13 mm: 35.45 µm, 25 mm: 3.45 µm, 32 mm: 7.8 µm, 13 mm: 15.8 µm, 25 mm: 7.8/.2 µm, 25 mm: 145.8/.2 µm, 32 mm: 44 1.2 µm, 32 mm: 17 5 µm, 32 mm: 175 GF/.2 µm, 37 mm (Serum Acrodisc Filter): 425 <.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test Biological Safety Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88> Sterilized by gamma irradiation and individually packaged 5.2 bar (52 kpa, 75 psi) Acrodisc Syringe Filters with Supor Membrane (Sterile) 462.2 µm, 13 mm 75/pkg 464.45 µm, 13 mm 75/pkg 468.8 µm, 13 mm 75/pkg 4611.1 µm, 25 mm 5/pkg 4612.2 µm, 25 mm 5/pkg 4614.45 µm, 25 mm 5/pkg 4618.8 µm, 25 mm 5/pkg 4651.1 µm, 32 mm 5/pkg 4652.2 µm, 32 mm 5/pkg 4654.45 µm, 32 mm 5/pkg 4656 1.2 µm, 32 mm 5/pkg 465 5 µm, 32 mm 5/pkg Serum Acrodisc Syringe Filter (Sterile) 4525 GF/.2 µm, 37 mm 2/pkg Acrodisc PF Syringe Filters (Sterile) 4187.8/.2 µm, 25 mm 5/pkg 4658.8/.2 µm, 32 mm 5/pkg www.pall.com/lab

Sterile Acrodisc Syringe Filters - Ideal for Proof of Concept Four membrane types, Fluorodyne II, Supor, Posidyne, and Ultipor membranes, assure compatibility with a wide range of fluids. Integrity testable (water bubble point). Simplify scale up and reduce validation. Bacterial retention tested to assure sterile filtrate. Laboratory filters containing the same materials of construction as larger-capacity capsules and cartridges. No need to change membrane materials during transition to pilot or full-scale production. Drug development studies Determination of product compatibility and recovery Preliminary filterability testing Small volume liquid sterilization Specifications Filter Media: Supor membrane (hydrophilic polyethersulfone), Ultipor membrane (amphoteric Nylon 6,6), Fluorodyne II membrane (hydrophilic polyvinylidene fluoride), Posidyne membrane (positively-charged Nylon 6,6) Housing: Polypropylene 2.8 cm 2 Female luer lock inlet, male slip luer outlet 1 µl 6 C (14 F) at 2.1 bar (21 kpa, 3 psi) 5.4 bar (54 kpa, 8 psi) at ambient temperature Recommended Integrity Test Minimum Bubble Point Water PN 495: 3.5 bar (35 kpa, 51 psi) PN 496: 3.2 bar (32 kpa, 46 psi) PN 497: 3.2 bar (32 kpa, 46 psi) PN 498: 3.2 bar (32 kpa, 46 psi) Bacterial Retention Lot samples retain 1 7 cfu/cm 2 of B. diminuta per modified ASTM F838-83 <.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test Biological Safety Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88> Sterilized by gamma irradiation and individually blister packed ml/min at 2.1 bar (21 kpa, 3 psi) PN 495: 13 PN 496: 78 PN 497: 13 PN 498: 77 Acrodisc Syringe Filters (Sterile) 495.8/.2 µm Supor membrane, 5/pkg 25 mm 496.2 µm Ultipor membrane, 5/pkg 25 mm 497.2 µm Fluorodyne II 5/pkg membrane, 25 mm 498.2 µm Posidyne membrane, 5/pkg 25 mm

Sterile Acrodisc Syringe Filters with Versapor Membrane Ideal for clarification or prefiltration of virtually all aqueous samples. Variety of diameters and pore sizes to meet most aqueous sample filtration needs. Certified non-pyrogenic and biologically safe. The economical choice for prefiltration of viscous or particulate-laden samples, serum filtration, and dissolution testing. Specifications Filter Media: Versapor membrane (acrylic copolymer on a nonwoven support) 5 mm Prefilter Media: Binder-free borosilicate glass fiber Housing: Modified acrylic 25 mm: 2.8 cm 2 5 mm: 19.6 cm 2 25 mm: Female luer lock inlet, male slip luer outlet 5 mm: Stepped hose barb 25 mm: < 5 µl 5 mm: 2 ml 25 mm: 55 C (131 F) 5 mm: 82 C (18 F) 25 mm: 5.2 bar (52 kpa, 75 psi) 5 mm: 4.1 bar (41 kpa, 6 psi) ml/min at 3.1 bar (31 kpa, 45 psi).8 µm, 25 mm: 6 1.2 µm, 25 mm: 66 5 µm, 25 mm: 97 ml/min at 1. bar (1 kpa, 15 psi) GF/5 µm, 5 mm: 17 <.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test Biological Safety Passes United States Pharmacopeia (USP) Biological Reactivity Test, In Vivo <88> Sterilized by gamma irradiation and individually packaged Acrodisc Syringe Filters with Versapor Membrane (Sterile) 4188.8 µm, 25 mm 5/pkg 419 1.2 µm, 25 mm 5/pkg 4199 5 µm, 25 mm 5/pkg Acro 5A Device with Versapor Membrane (Sterile) 4276 GF/5 µm, 5 mm 18/pkg www.pall.com/lab

DMSO-Safe Sterile Acrodisc Syringe Filter with Nylon Membrane Polypropylene housing and nylon membrane are compatible with solutions containing DMSO. Ideal for sterilization of media used for cell cryopreservation. Offers broad chemical resistance to common solvents. Specifications Filter Media: Nylon Housing: Polypropylene 2.8 cm 2 Female luer lock inlet, male slip luer outlet 5 µl 6.2 bar (62 kpa, 9 psi) 6 ml/min at 2.1 bar (21 kpa, 3 psi) <.25 EU/mL using Limulus Amoebocyte Lysate (LAL) test Sterilized by ethylene oxide and individually blister packed 55 C (131 F) DMSO-Safe Acrodisc Syringe Filter with Nylon Membrane (Sterile) 4433.2 µm, 25 mm 5/pkg

Complementary Products Comprehensive line of Supor and Versapor membrane disc filters. Precise, high-performance centrifugal devices to process < 1 µl to 6 ml. Fast, sterile, AcroCap positive pressure device for volumes up to 3 liters. Efficient AcroPak 2 filters for volumes up to 5 liters. Innovative, sterile VacuCap bottle-top filters for vacuum filtration of 1 ml to 5 liters. Capsules with Supor, Fluorodyne II, and Versapor membranes for filtration of larger volumes. Non-sterile Acrodisc Syringe Filters with Supor Membrane 456.2 µm, 25 mm 1/pkg 458.45 µm, 25 mm 1/pkg 459.8 µm, 25 mm 1/pkg 454.8/.2 µm, 25 mm 1/pkg 4655.2 µm, 32 mm 1/pkg 4653.45 µm, 32 mm 1/pkg 4659.8/.2 µm, 32 mm 1/pkg 466 1.2 µm, 32 mm 1/pkg 4661 1.2/.45 µm, 32 mm 1/pkg 4662 5 µm, 32 mm 1/pkg Non-sterile Acrodisc Syringe Filters with Versapor Membrane 4473.45 µm, 4 mm 25/pkg, 75/cs 4459.8 µm, 13 mm 1/pkg, 3/cs 4487.45 µm, 25 mm 75/pkg, 3/cs 4189.8 µm, 25 mm 75/pkg, 3/cs 4568.8 µm, 25 mm 1/pkg 4488 1.2 µm, 25 mm 75/pkg, 3/cs 4489 5 µm, 25 mm 75/pkg, 3/cs Non-sterile Acro 5A Devices with Versapor Membrane 4264 GF/5 µm, 5 mm 18/pkg 4592 GF/5 µm, 5 mm 1/pkg The UpScale SM Program Pall Corporation has the most comprehensive family of scaleable filtration products that simplify validations and ease transitions from R&D to pilot to full-scale production. Look for these scaleable products with Supor, Fluorodyne II, Posidyne, and Ultipor membranes: Membrane disc filters Acrodisc syringe filters with polypropylene housings AcroPak 2 filters for processing up to 5 liters AcroPak 2 capsules for processing 5 to 2 liters AcroPak 4 and 8 capsules for processing volumes over 1 liters Process-scale capsules and cartridges from Pall Life Sciences Pall Life Sciences 6 South Wagner Road Ann Arbor, MI 4813-919 USA 8.521.152 toll free in USA 734.665.651 phone 734.913.6114 fax Australia Cheltenham, VIC Tel: 3 9584 81 18 635 82 (in Australia) Fax: 18 228 825 Austria Wien Tel: 1 49 192 Fax: 1 49 192 4 Canada Ontario Tel: 95-542-33 8-263-591 (in Canada) Fax: 95-542-331 Canada Québec Tel: 514-332-7255 8-435-6268 (in Canada) Fax: 514-332-996 8-88-6268 (in Canada) China P. R., Beijing Tel: 86-1-8458 41 Fax: 86-1-8458 41 France St. Germain-en-Laye Tel: 1 3 61 39 92 Fax: 1 3 61 58 1 Lab-FR@pall.com Germany Dreieich Tel: 613-37 333 Fax: 613-37 399 Lab-DE@pall.com India Mumbai Tel: 91 () 22 55995555 Fax: 91() 22 55995556 Italy Milano Tel: 2 47 79 61 Fax: 2-47796 394 or 2-4122 985 Japan Tokyo Tel: 3-691-58 Fax: 3-5322-2134 Korea Seoul Tel: 82-2-56-7871 Fax: 82-2-56-7822 Malaysia Selangor Tel: +6 3 5569 4892 Fax: +6 3 5569 4896 Poland Warszawa Tel: 22 51 21 Fax: 22 51 211 Russia Moscow Tel: 5 1 787 76 14 Fax: 5 1 787 76 15 Singapore Tel: (65) 389-65 Fax: (65) 389-651 South Africa Johannesburg Tel: +27-11-26623 Fax: +27-11-3253243 Spain Madrid Tel: 91-657-9876 Fax: 91-657-9836 Sweden Lund Tel: ()46 1584 Fax: ()46 32781 Switzerland Basel Tel: 61-638 39 Fax: 61-638 39 4 Taiwan Taipei Tel: 886 2 2545 5991 Fax: 886 2 2545 599 Thailand Bangkok Tel: 66 2937 155 Fax: 66 2937 166 United Kingdom Farlington Tel: 2392 326 Fax: 2392 3261 Lab-UK@europe.pall.com Visit us on the Web at www.pall.com/lab E-mail us at Lab@pall.com 27, Pall Corporation. Pall,, Acro, AcroCap, AcroPak, Acrodisc, Fluorodyne, Posidyne, Supor, Tuffryn, Ultipor, VacuCap and Versapor are trademarks of Pall Corporation. indicates a trademark registered in the USA. and UpScale are service marks of Pall Corporation. Luer-Lok is a trademark of Becton, Dickinson & Co. 6/7, PDF, GN7.164 PN33175