Temperature Sensors. General. Specification. Description



Similar documents
Pipe Temperature Sensors

A99B Series Temperature Sensors

Duct Temperature Sensors

Toroidal Conductivity Sensor

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Submersion/Insertion Toroidal Sensor

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

FEATURES BODY DIA. MAX. Type M AWG 30: [0.254] Type C AWG 28: [0.320] Type T AWG 30: [0.254]

HMI display Installation Guide

T7079A,B Solid State Remote Temperature Controllers

Arecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual

Digital inductive conductivity transmitter

BB-18 Black Body High Vacuum System Technical Description

ATL Fuel Level Sender Probes

Duct Humidity Transmitter

Installation Guidelines: Resistance Thermometers and Temptran Thermometers for Building Automation Systems

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

NTC Thermistors, Radial Leaded and Coated

HVAC Sensors Catalogue

Submersion/Insertion Toroidal Sensor

Mini USB and USB 2.0-IP67 Connector System

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

Improving Temperature Measurement to Optimize Inventory Control and Custody Transfer Systems

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

Heating Cable. Construction

Directory chapter 04

08. SEK IDC CONNECTORS

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

Typical Aluminum GFM Mass Flow Meter

4 Posiflow Proportional Solenoid Valves

Detection of Pipe Leaks Connection of Pulse Monitoring System in Thermal Utilities

Thermwire. Selection Guide. Freeze Protection Heating Cable. Thermwire -Wrap. Pre-Assembled. Thermwire-Comp. Thermwire-Melt.

EH-20 20m antenna. By VE3RGW

Air-Conditioning, Heating, and Refrigeration Institute. Sheet Metal and Air-Conditioning Contractors National Association

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

V47 Series Temperature Actuated Modulating Water Valves

RTD Temperature Probe for the Food/Pharmaceutical Industry

TC-9102 Series Surface Mount Temperature Controllers

Scraper Passage Indicator. Electrical Indicator. Features

Portable digital microprocessor thermometers with interchangeable probes

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

INSTALLATION INSTRUCTIONS HUSTLER 4-BTV, 5-BTV TRAP VERTICAL WARNING INSTALLATION OF THIS PRODUCT NEAR POWER LINES IS DANGEROUS

PART 1 - INTRODUCTION...

Sanitary and CIP Toroidal Sensor

LM35 Precision Centigrade Temperature Sensors

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Technical data sheet TDS0070

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Pressure transmitter For general industrial applications Model A-10

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Contents. Document information

Screw Plug Immersion Heaters

Instruction Manual. T3111 T3111L T3111P T3111Ex

Vehicle Brake System Monitoring 2-wire, 4-20 ma option; Intrinsic Safety Approval to E Exia IIC T4 (Tamb=60 C) BASEEFA, CENELEC EN50-020

Installation Instructions DTS-HAZ DTS-HAZ-DC. for Use with Self-Regulating & Constant Wattage Heating Cables

CHM-27 COB Arrays White LED

Online data sheet PET-1CB010N10SVMC PET PRESSURE SENSORS

SMD Rework Station TABLE OF CONTENTS

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Quick Connect. RTDs, Cordsets and Transmitter with M12 Connections

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

400 Series - Mini USB Buccaneer

Capacitive Prox E2K-X

BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

EPHY-MESS GmbH phone: Berta-Cramer-Ring 1 fax: Wiesbaden info@ephy-mess.de Germany

B MOTORSPORT COMPONENTS B13. Max Circuit Measurement Characteristic Current Thread Part Number Range Curve [A] Size Connector Figure Comment

Vario-Series Accessories

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Threaded Resistance Thermometers Model TR10-D, Miniature Design

Installation Guide. WSD-100 Wind Speed and Direction Sensor For XR5 Data Loggers. February, 2011

RAY-MAX Integrated Solar Power Strip

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

STRATO LED Drivers 70W, Single output

Munchkin Heat Exchanger Maintenance

920 Series. Dual-point heat-tracing control system. Product overview. 920*E4FWL*SIS302*SS3102 shown

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

Thermal Mass Flow Meter (Series MST)

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

For Multi-Parameter Meters see mvx

Explosion-Proof Electric Unit Heaters

IEC Connectors. Introduction

ALARMLINE ANALOGUE Linear Heat Detection System

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

Stainless steel process fittings

Thermistor Basics. Application Note AN-TC11 Rev. A. May, 2013 Page 1 WHAT IS A THERMISTOR?

Transcription:

Description Temco Controls manufactures temperature sensors for the air conditioning industry. This document shows the enclosures and temperature vs. resistance curves for the standard sensors. General The sensors employ precision interchangeable thermistors and RTD which are compatible with all the major building automation systems. Designed for temperature sensing in an HVAC and light industrial control applications. Precision interchangeability eliminates the necessity for individual circuit calibration. Data sheets for the standard items appear on the web at www.temcocontrols.com. Temco is able to produce custom sensors in small volume at standard sensor pricing. There are several sensor element ranges to choose from, which guarantee compatibility with all popular DDC systems. The sensor elements are precision thermistors or platinum RTDs. Field calibration is not generally required. The probe is epoxy sealed to prevent moisture from migrating into the probe. Custom probe lengths, wire types and sensor elements are available for large OEM projects. Ask about our plastics & metal manufacturing capabilities for custom housings as well. Part # Suffix Sensor Typical User 2 100 ohm Platinum 3-wire Honeywell 5 1,801 ohm Thermistor t.a.c. / CSI 6 3,000 ohm Thermistor Alerton -7 10,000 ohm Thermistor Type2 Trane, Automated Logic, Temco, t.a.c., CSI, Solidyne, Alerton 9 100,000 ohm Thermistor Siemens(Landis & Staefa) 11 LM334 IC sensor t.a.c. / CSI 12 1000 ohm Platinum 13 1000 ohm Nickel Johnson Controls 20 20,000 ohm Thermistor Honeywell 21 LM335 IC Sensor Solidyne, IECC -24 10,000 ohm Therm, Type 3 Specifications: Sensor Property Thermistor Accuracy Platinum RTD Accuracy - 1 - Specification +/- 0.2 C +/- 0.4 C Thermistor Range -70 C to 150 C Platinum RTD Range -200 C to 300 C Probe Material Cable Properties Invensys(siebe), Honeywell, Johnson Controls, Siemens (Landis & Staefa) Andover, AAM, Teletrol, Invensys(Siebe), Multinet, Delta, Carrier, KMC, Temco Stainless Steel FT4, 80 C, 600V

Duct Temperature Sensor Plastic Water Resistant Box: Metal Electrical Box: Dimensions(mm): - 2 -

Ordering Information: - 3 -

DTS-FL: Flange Mount Duct Temperature Sensor Descriptions: This sensor is used to measure the supply and return temperature in HVAC system. The flange mount design makes it easy to install the sensor in tight quarters. There are several sensor elements to choose from which guarantee compatibility with all popular DDC systems. The probe in the photo is out standard model which is always in stock, it has a 8 inch probe and 6 inch long cable, and employs either a precision thermistor or platinum film sensor field calibration is not generally required. The 10ft(3m) cable is plenum rated. Contruction: The sensor is a high quality unit manufactured to high standards, using materials and assembly techniques. The probe material is stainless steel with a welded and ground tip.the DTS probe is baked and then epoxy sealed to eliminate long term moisture problems. The flange accepts two #6 screws, and is made from glavanized steel. Ordering Information: - 4 -

OAT: Outside Air Temperature Sensor Descriptions: This sensor is used to measure the outside air temperature to allow the DDC system to coordinate the mechanical systems with actual building load conditions, enabling such strategies as free cooling, optimum start / stop, and supply temperature reset. The housing is made from PVC electrical fittings which shield the probe from direct sunlight. The probe is manufactured to industrial standards. There are three thermistor based models, and one RTD version to provide compatibility with the majority of DDC systems. The sensors are accurate enough that calibration is not usually required. Specifications: Sensor Property Thermistor Accuracy Platinum RTD Accuracy Thermistor Range Probe Material Cable Properties Specification ±0.2 O C ±0.4 O C -40 ~ 120 O C Stainless Steel FT4, 80 O C, 600V Contruction: The sensor probe is made from stainless steel which is welded, ground down, and finally pressure tested before assembling. The probe is then baked and epoxy sealed to provide long term protection from moisture. The sensor housing is a PVC electrical enclosure which is UL approved for outdoor use. The housing extends over the probe to protect from sunlight radiation. The sensor lead extends 12 from the enclosure, making it long enough to reach a junction box and terminate inside the building. The thermistor models are accurate to 0.2 O C while the platinum RTD is accurate to 0.5 O C. Installation: The OAT sensor can be mounted on the outside of the building using the following guidelines: Choose a spot on the north face which will be out of sunlight for as much of the day as possible. Mount the sensor where it can be serviced, staying away from exhaust ducts. Point the probe downwards to avoid catching rain. To install the sensor, drill a 3/4 (20mm) hole through the wall, and pipe the sensor to an electrical junction box on the inside of the wall. The sensor has a female 1/2 NPT threaded fitting to accept a short length of 1/2 pipe or PVC. Two conductors are required, 18ga, unshielded twisted pair is common. - 5 -

Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an email if you don t see what you need online. - 6 -

OAT: Outdoor Air Temperature Sensor Features General purpose outdoor air temperature sensor Available in threaded PVC version with rugged weatherproof electrical box Easy installation - just threads into mounting hole or standard handy box installation Fully potted metal housing protects sensing element and provides fast, accurate temperature sensing Cost efficient design Sturdy construction - all plastic housing with PVC solar shield with optional weatherproof electrical box Description The temperature sensor is designed to measure outdoor air temperature. The sensor isdesigned for mounting in a standard ½ knock out.the temperature sensor uses a 10K Ω thermistor. The thermistor is enclosed in a plastic housing.the sensor has a short 20AWG black leads. It is designed for use in residential and commercial building automation controls. It features a fast response, precision thermistor sensing element that is totally sealed against the outdoor elements. The PVC sun-shield prevents false readings from direct sunlight. An optional weatherproof electrical box allows for simple installation and provides an extra rugged and reliable sensor for energy management and HVAC applications. Dimensions(mm) - 7 -

OAT: Outdoor Air Temperature Sensor Table 1: Lead Wiring (20 AWG, 6 in.) Color Code Sensor Type Lead Color Resistance Chart 10k ohm Thermistor White 1k ohm Platinum White 3k ohm Thermistor White 10k ohm Type II Thermistor White 10k ohm Type III Thermistor White The accuracy of the resistor can be verified using an Ohm meter. The chart below shows the resistance for various temperatures. Temperature (ºF) Temperature (ºC) Resistance (Ohms) -40-40 336,450-30 -34 234,170-20 -29 165,210-10 -23 118,060 0-18 85,399 10-12 62,493 20-7 46,235 30-1 34,565 40 4 26,100 50 10 19,899 60 16 15,311 70 21 11,883 80 27 9,299 90 32 7,334 100 38 5,828 110 43 4,664 120 49 3,758 130 54 3,048 140 60 2,488 150 66 2,042 160 71 1,686 170 77 1,400 180 82 1,169 190 88 981 200 93 827-8 -

OAT: Outdoor Air Temperature Sensor Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an email if you don t see what you need online. - 9 -

Room Temperature Sensor RTS: Room temperature sensor, 10K type 2 RTS1: Tamper proof room temperature sensor, 10K type 2 RTS3: Flush mounting sensor, 10K type 2-10 -

WTS Series Water Temperature Sensor WTS-MO: WTS-WP: WTS-M1: WTS-P: Outdoor Rated Watertight Plastic Metal Probe Only Installation: Locate water temperature sensor at least a few pipe diameters downstream any heat or cooling source: A 1/2 NPT female pipe fitting is welded into the pipe. These fittings are usually supplied and installed by the piping trade under direction of the controls trade. Choose an orientation where any condensation will not collect, such as the top of a horizontal pipe section or at a 45 angle from horizon. Before threading the sensor into the well, deposit some thermal paste in the bottom of the well to improve heat conduction between the metal parts. The sensor is wired with two conductors, normally 18ga unshielded twisted pair. Ordering Information: - 11 -

WTS5 Series Strap on Water Temperature Sensor WTS5-WP: WTS5-M1: Installation: For measuring water temperature, the probe is strapped with plastic tie wraps or a metal strap onto the outside of the pipe and covered with insulation. The electrical box is mounted on a strut bar or on the wall near the pipe. Two conductors are required, 18ga, unshielded twisted pair is common. Ordering Information: - 12 -

RTS-Raw 10K NTC Thermistor, Temco s standard thermistor element Specifications: Rated Resisitance: R25=10.00KΩ±1% B-Value: B25/50=3950Ω±1% OperatingTemperature: -40 ~ +120 C Dimensions (mm): 1: TC39B103F 2: Epoxide Resin, Clear 3: Ø0.5mm Tinned Copper Wire RTS-Bead-4: Thermistor bead, 4 (10cm) lead, 10mm wire trimmed and tinned, 0.2DegC accuracy Specifications: Zero Power Resistance: R25=10.00kΩ ±1% B-Value: B25/50=3950K ±1% Operating Temperature Range: -40 ~ +120 C Insulated Resistance: 500VDC in water, >100M Ω Breakdown Voltage: 1500VAC in water, 1 minute. No flash over (Leak Current: 1mA Max). Dimensions (mm): 1: TC39B103F 2: EPOXY RESIN 3: UL2468 26/2CAWG 105 C Black Wire - 13 -

PRB-0.6-7 Temperature Sensor: 0.6 SS probe temp sensor, 10K thermistor, Type 2 Temperature Sensors Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Optimal Operating Temperature Range: -40 ~ +120 C Insulated Resistance: 500VDC in water, >100MΩ Breakdown Voltage: 1500VAC, 1min. Dimensions (mm): 1: TC39B103F 2: Ø5x15 Stainless Steel 3: UL2468 26/2CAWG 105 C Black Wire Ordering Information: - 14 -

PRB-50-45-7 Temperature Sensor: ID6 X 50mmprobe temp sensor, 10K thermistor, Type 2 Temperature Sensors Specifications: Nominal Resistance: R25=10.00kΩ±1% B Value: B25/50=3950K±1% Optimal Operating Temperature Range: -40 ~ +120 C Dimensions (mm): 1: Ø6x50 Stainless Steel 2: UL2464 20/2CAWG 105 C Black Wire Ordering Information: - 15 -

PRB-8-8-12 Temperature Sensor: ID6mm X 200mm probe temp sensor, 1K Platinum thermistor Specifications: Nominal Resistance: R25=1000Ω±1% B Value: 1000Ω±1% Optimal Operating Temperature Range: -200 ~ +400 C Platinum temperature sensor: P1K0.232.4W.K.010 Tolerance Classes: DIN EN 60751 F 0.3 (former Class B) Extension : Wire Connections Dimensions (mm): Ordering Information: - 16 -

PRB-15-10-9 High Temperature Sensor: ID6 X 15mm probe temp sensor, 100K NTC thermistor Specifications: Nominal Resistance: R25=100kΩ±1% B Value: B25/85=4066K±1% Optimal Operating Temperature Range: -40 ~ +250 C Absolute max 300 Cfor short periods Dimensions (mm): 1: Ø6x15 Stainless Steel 2: UL16302 24/2CAWG 250 C Black Wire Absolute max 300 C for short periods Product model specification - 17 -

Ordering Information: - 18 -

Temperature Curves: Part # -> DegC 3K -6 Thermister Type, Ohms / Part Number Suffix 10K Type2-7 10K Type3-24 20K -20 100K -9 1K RTD -12-40 100,701 335,671 239,700 814,000 4,067,212 843-35 72,658 242,195 187,500 578,600 2,890,843 863-30 53,005 176,683 135,300 415,600 2,077,394 882-25 39,073 130,243 107,105 301,000 1,508,530 902-20 29,092 96,974 78,910 220,600 1,106,485 922-15 21,868 72,895 63,225 163,600 819,378 941-10 16,589 55,298 47,540 122,380 612,366 961-5 12,694 42,314 38,515 92,300 461,683 980 0 9,795 32,650 29,490 70,200 351,017 1,000 5 7,618 25,395 23,460 53,800 269,041 1,020 10 5,971 19,903 18,790 41,560 207,807 1,039 15 4,714 15,714 15,130 32,340 161,702 1,059 20 3,748 12,493 12,260 25,340 126,729 1,078 25 3,000 10,000 10,000 20,000 100,000 1,105 30 2,416 8,056 8,194 15,884 79,428 1,117 35 1,959 6,530 6,752 12,696 63,489 1,136 40 1,597 5,324 5,592 10,210 51,058 1,155 45 1,310 4,366 4,655 8,258 41,301 1,175 50 1,080 3,601 3,893 6,718 33,598 1,194 55 896 2,985 3,327 5,494 27,479 1,205 60 746 2,487 2,760 4,518 22,593 1,232 65 625 2,082 2,375 3,734 18,669 1,244 70 526 1,751 1,990 3,100 15,502 1270.7 75 444 1,480 1,724 2,586 12,932 1,290 80 377 1,256 1,458 2,186 10,837 1308.9 85 321 1,070 1,271 1,824 9,121 1,328 90 275 916 1,084 1,542 7,709 1,347 95 236 787 950 1,308 6,542 1,366 100 204 679 817 1,114 5,574 1385 105 176 587 720 953 4,767 1,404 110 153 510 624 818 4,093 1422.9 115 133 445 553 705 3,525 1,442 120 117 389 481 609 3,046 1,460-19 -

Wells (Brass and Stainless Steel): Descriptions: The machined stainless steel and brass thermowells are designed for mounting temperature sensors in pipes and tanks. The thermowells are designed to reduce the stress encountered in a flowing fluid installation which produces a constantly oscillating force that can eventually crack a probe unless mounted within one of these wells. The wells are designed to handle the stress, while providing good thermal contact with fluid. They also provide isolation, if the sensor needs to be serviced the system can remain in operation without having to drain the lines. Features & Options: Three Lengths: 2, 4 and 8 Stainless Steel (304) or Brass Two Part (Welded) or Machined Construction Other Lengths or Materials Available Upon Request Limited Lifetime Warranty Ordering Information: - 20 -

Dimensions DDC Type: 2 inch Dimensions (mm): 4 inch & 6 inch Dimensions (mm): 8 inch Dimensions (mm): - 21 -

Honeywell 10mm Capillary Tube: - 22 -

Strap On Temperature Sensor Technical data Measuring range -30 to +180 C -30 to +150 C (NTC) Sensing elements See ordering (other elements on request) Isolation resistance > 100Mohm, at 20 C (500 Vdc) Connections 1-wire (on request 3 and 4-wire) Strap-on band length 300 mm, for pipe diameter 13 to 92 mm (1/4 to 3 ) (other strap-on lengths on request) Cable lenght 1 metres Cable material Silicone Cup dimensions L = 50 mm x D = 6mm Protection IP 54 Features Sensing elements Thermistors, Platinum and Nickel,NTC 10K.,NTC 3K,NTC 10K Type2, NTC 10K Type3,PTC, PT1000, etc Included 300 mm adjustable strap-on band,for pipe diameter 13 to 92 mm (1/4 to 3 ) IP 54 protection Simple 1-wire connection Economical way to measure temperature Application/Description The strap-on temperature sensor is used for sensing the temperature of pipework in heating, ventilation and air conditioning systems. The strap on is passive immersion temperature sensor available with different sensing elements such PT1000, NTC, PTC etc. Passive sensing elements is a low cost alternative to measure temperature with simple 1 wire connection. The sensing element is housed in a 50 mm long probe (cup). The probe will be fixed to the pipe with an adjustable 300 mm,strap-on band, other strap-on lengths on request. - 23 -

Strap On Temperature Sensor Application/Description The strap-on temperature sensor is used for sensing the temperature of pipework in heating, ventilation and air conditioning systems.it is passive immersion temperature sensoravailable with different sensing elements such as NTC 10K.,NTC 3K,NTC,10K,Type2,NTC,10K Type3,PTC,PT1000 etc.passive sensing elements is a low cost alt native to measure temperature with simple 1 wire connection. The sensing element is housed in a 50 mm long probe (cup). The probe will be fixed to the pipe with an adjustable 300 mm,strap-on band, other strap-on lengths on request. Ordering Type no. Description NTC 10K Strap-on temperature sensor with cable NTC 3K Strap-on temperature sensor with cable NTC 10K Type2 Strap-on temperature sensor with cable NTC 10K Type3 Strap-on temperature sensor with cable PT1000 Strap-on temperature sensor with cable Dimensions (mm) - 24 -

Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an email if you don t see what you need online. - 25 -

Strap On Insert Temperature Sensor: Strap-on Insert Sensor The strap-on Insert sensor consists of a stainless steel sheath temperature sensor, thermal conducting compound, and an adjustable pipe bracket accessory. The stainless steel sheath temperature sensor is suitable for direct application to pipe surfaces for chilled or hot water measurement. It is also used for freezer cases, where moisture protection is important. Strap-on Applications Where it is not practical to install immersion wells, the stainless sheath sensor may be strapped to the pipe. A pipe strap accessory provides a bracket to hold a thermally conductive compound and clamps the sensor securely in place. Make electrical connections to the sensor in accordance with the installation wiring diagram for the job and in accordance with national and local electrical codes. Use the one big-foot lead furnished with the sensor. Do not use wire nuts. Though the sensor itself does not require shielded cable, some controllers and microprocessors do;check with the controller supplier. Accuracy ±36 F from 32 F to 158 F) ±2 C from 0 C to 70 C) Stability 24 F (-4.4 C) over 5 years Basic Model Basic model comes with one foot lead and a 0.24-inch stainless steel tube. Typical Mounting When used as a strap-on Insert sensor, best results are obtained when conductive compound is applied between the sensor and the pipe. In addition, the sensor should be inserted under insulation with at least 4mm of the sensor lead covered. A pipe clamp accessory is available for use with this sensor. - 26 -

Strap On Insert Temperature Sensor: Adjustable Pipe Bracket Accessory The pipe bracket is designed for use with the stainless sheath sensor. The bracket can be used on pipe sizes from 2" (50.8mm) to 8" (203mm) outside diameter. Thermal conducting compound should be used with the bracket to improve heat transfer between the pipe and the temperature sensor. Dimensions (mm) - 27 -

Ordering Information: *Thermistors,pt elements and probe sizes for all popular control systems are available,send us an email if you don t see what you need online. - 28 -