One wire. Many possibilities.



Similar documents
TURQUOISE PTCA BALLOON DILATATION CATHETER

Yukon Choice DES + Translumina - The polymer-free DES solution. Coronary Stent System for Drug Application

Coronary & Peripheral Guidewires. Roby Rakhit

Digital input modules

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Tracheal Stent System

Evaluation copy. Blood Pressure. Project PROJECT DESIGN REQUIREMENTS

psens Pressure Measurement

Deflectable & Steerable Catheter Handbook

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

Evaluation copy. Build a Temperature Sensor. Project PROJECT DESIGN REQUIREMENTS

Joline - a modern medical technology company built on tradition. For further information please contact us!

5,000 lb Capacity. Wireless Communication Scale

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Everything you need for protection scheme testing

Choice of guiding catheters and guidewires

Merge Healthcare Cardiology Differentiators. A Merge White Paper

Special Specification 6033 Computerized Transportation Management System

RVG Full range imaging for diagnostic confidence ROBUST DESIGN SUPERIOR ERGONOMICS NEW IMAGE PROCESSING TOOLS ENHANCED WORKFLOW

When Procedural Support really matters. Navien TM A+ Intracranial Support Catheter

Sense it! Connect it! Bus it! Solve it! EncoderS

EMC Test Chamber Solutions RF Cable Assemblies and Connectors

UV-Vis spectrophotometers

TX OPEN RS232/485 module

A-307. Mobile Data Terminal. Android OS Platform Datasheet

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

modular exhibit solutions

Pipe Cutting and Beveling Clamshells

SAMSUNG ULTRASOUND RS80A

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

Bringing together all of the cardiovascular information you need into a single platform

Conductive Level Switch FK 2 Technical Data:

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

California Health and Safety Code, Section

WIND Power Technology: IMD Integrated Motor Drive

POLARIS OPTICAL TRACKING SYSTEMS

Samsung Ultrasound H60

RVG Innovation set free.

Philips CX50 CompactXtreme System. A New Class of Compact Echocardiography

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

Electromagnetic Flow Meter

Leica Zeno 20 GIS Data Collector

Why a torque measuring system?

HMI display Installation Guide

This product can be assembled to the baseplate maintaining 5 mm center-to-center spacing. Thus any number of poles can end-to-end stack.

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

YOUR PARTNER FOR THERMAL IMAGING SECURITY APPLICATIONS

ABB PSPS Erich Steinmann; Generator control-2013

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

sailboat Proven engines, saildrives and options for all conditions

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide. 910 East Orangefair Lane, Anaheim, CA info@anaheimautomation.

Programming Logic controllers

SITRANS F M MAG 8000 Precise Metering with battery powered water meters. sitrans f

Tobii X2 Eye Trackers

Critical Care Therapy and Respiratory Care Section

Relative and absolute pressure switch type 529

Understanding Device Level Connection Topologies

Lightweight, compact, ergonomic, safe POLARIS FID. Portable TOC Analyser for Stack Emissions

AutoLink Three-Phase Sectionalizer Specifications. Scope. General. Applicable Standards. Operating principle

GeoMax GNSS Zenith10 & Zenith20 Series

The new generation: WLL180T photoelectric sensor with fiber-optic cable. Around the corner at High Speed

_Tailor made solutions Our strength is our commitment.

Single Mode Fiber Lasers

Electric Rotary Actuator - On/Off or programmable control actuator

SIMATIC VS720A and VS720-S series Intelligent cameras with PROFINET

How To Use A Ds340 (Dsp)

Measurement & Analytics Measurement made easy

Leica Zeno 20 More than GPS

Nikon s DigiMicro Position Encoders Nanometer Resolution with Sub-Micron Accuracy

The Do s and Don ts of Pressure Transducers

January 28, (k) Submitter's Name and Address

MFI-capital.com Zuiderlaan 1-3, bus Gent, Belgium info@mfi-capital.com

MDC Series

Float & Tape Tank Gauging Solutions for Bulk Liquid Storage Tanks. Simple, Safe and Reliable Inventory-Grade Level Measurement

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

CRM. Fully understand your customer by putting them at the heart of what you do

Micro Motion 3098 Gas Specific Gravity Meter

Agfa HealthCare. Image Enable the EHR! RSNA 2009 Visit us at Booth #8324 I North Hall

GORE Aerospace Cables and Materials

Servo Motors (SensorDAQ only) Evaluation copy. Vernier Digital Control Unit (DCU) LabQuest or LabPro power supply

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Distribution Voltage Regulators

SAILboat 2014 ENGINES, OPTIONS AND NEWS

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

Simple Electrical Utility Cost Allocation Solutions

Low Frequency Velocity Sensor

HP RETAIL POINT OF SALE SOLUTION PORTFOLIO

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Talent Management and Acquisition Training

Physical Specifications (Custom design available.)

IAdea GPIO Extender Application Note

Galaxy Flex SECURITY THAT FITS WITH YOUR BUSINESS AND LIFESTYLE. Protect your property

Transcription:

One wire. Many possibilities. OptoWire One. The one wire you need for pre- and post-procedure FFR and device delivery. Medical

Experience an entirely new level of productivity with OptoWire One Reliable connectivity Opsens connector technology is not affected by blood or contrast agents. With a simple twist-lock motion, you can connect and disconnect OptoWire One multiple times and still achieve reliable FFR assessments. Imagine the ability to perform FFR in multi-vessel coronary arteries, successfully deliver interventional devices and conduct post interventional FFR assessment with the same wire, accurately and consistently. Introducing OptoWire One, a pressure guidewire with the ability to cross one or more lesions, withstand standard PCI procedures handling and multiple connecting, while still providing reliable FFR assessment. Nitinol Core Excellent kink resistance, torquablity and the ability to reach lesions successfully and easily with low whipping effect. In short, OptoWire One gives you more possibilities during a single PCI intervention. Allow us to share how OptoWire One makes this possible, thanks to a revolutionary design and advanced materials construction that is setting the new standard in pressure guidewire performance and versatility. Flexible Tip Atraumatic floppy tip provides optimal flexibility, good shapeability and retention. Optical FFR pressure sensing Driftless pressure sensor provides accurate measurement even with multiple connecting. PCI device support Innovative construction lets you perform PCI or stent placement without replacing the wire.

Improved guidewire performance OptoWire One is the first pressure guidewire that combines nitinol and stainless steel in a new and unique symmetrical design. The nitinol core contributes to high performance maneuverability and kink resistance, while the stainless steel shaft offers strength and improved pushability. The result is impressive torqueability and steerability so you reach lesions successfully and easily, and then perform standard PCI/stent device delivery with the same wire. Superior connectivity Opsens Medical s unique connector technology combines the two main elements for establishing and maintaining a reliable connection a robust connecting mechanism and the outstanding performance of Opsens optical technology. This optical link connection is easy to use, and its immunity to the effects of blood and contrast agents enable OptoWire One to maintain a consistent connection while achieving reliable FFR assessments. 1:1 Optical Fiber Torque Transfer Optical sensing for reliable pressure measurement Optimized for multiple lesions assessment Opsens Medical has been a pioneer in advanced fiber optic sensing technology for more than a decade, and our pressure sensor has been used in critical life support cardiovascular applications. Our unique sensor design is not affected by blood and temperature shift, delivering high fidelity pressure measurement with remarkable consistency. In fact, our pressure sensor is without equal when it comes to accuracy, long-term reliability and signal stability. With driftless pressure sensing, workhorse guidewire construction and highly reliable connectivity, OptoWire One can reliably perform FFR in multiple lesions, before and after PCI or stenting.

Easy cath lab integration Many hemodynamic systems now integrate FFR functionality for more efficient patient data consolidation. Opsens OptoMonitor can be connected directly to the cath lab hemodynamic system to display FFR directly on the cath lab monitor. OptoMonitor offers an intuitive display with easy navigation, and the option for USB data storage or FFR paper printout. The small footprint requires minimal space, which enables permanent installation and perpetual system availability. Simple integration OptoMonitor integrates with your existing hemodynamic system via a BP22 compatible output. It is easy to perform the initial setup, and it is ready to use anytime without further adjustments. Permanently installed The compact, rugged and lightweight design permits installation in the cath lab, and can easily be mounted on a bed or IV pole. Similar FFR workflow Conforms to your current FFR step-by-step functions. See the possibilities for yourself If you re seeking a way to easily navigate the coronary arteries reaching lesions with ease, accurately measuring intra-coronary blood pressure at all points, placing stents and performing post-assessment FFR all with the same wire, it is time you had a demonstration of OptoWire One. Intuitive workflow Logical workflow from left to right, with a visual indication to confirm completion of each task. Data integration FFR measurements are displayed on the OptoMonitor, and measurements can be saved to a USB key. For more information and a demonstration of Opsens Medical technology, please call 418-682-9996, or visit www.opsensmedical.com.

OptoWire One Optimized for multiple lesions assessment Reliable optical sensing technology Innovative guidewire construction with a nitinol core High performance maneuverability Perform PCI or stent placement without replacing the wire Conduct post-pci and post-stent assessment Medical Interventional cardiology in a whole new light #125, 2014, Cyrille-Duquet St. Quebec, Quebec G1N 4N6, Canada T: 418.682.9996 F: 418.682.9939 www.opsensmedical.com