One wire. Many possibilities. OptoWire One. The one wire you need for pre- and post-procedure FFR and device delivery. Medical
Experience an entirely new level of productivity with OptoWire One Reliable connectivity Opsens connector technology is not affected by blood or contrast agents. With a simple twist-lock motion, you can connect and disconnect OptoWire One multiple times and still achieve reliable FFR assessments. Imagine the ability to perform FFR in multi-vessel coronary arteries, successfully deliver interventional devices and conduct post interventional FFR assessment with the same wire, accurately and consistently. Introducing OptoWire One, a pressure guidewire with the ability to cross one or more lesions, withstand standard PCI procedures handling and multiple connecting, while still providing reliable FFR assessment. Nitinol Core Excellent kink resistance, torquablity and the ability to reach lesions successfully and easily with low whipping effect. In short, OptoWire One gives you more possibilities during a single PCI intervention. Allow us to share how OptoWire One makes this possible, thanks to a revolutionary design and advanced materials construction that is setting the new standard in pressure guidewire performance and versatility. Flexible Tip Atraumatic floppy tip provides optimal flexibility, good shapeability and retention. Optical FFR pressure sensing Driftless pressure sensor provides accurate measurement even with multiple connecting. PCI device support Innovative construction lets you perform PCI or stent placement without replacing the wire.
Improved guidewire performance OptoWire One is the first pressure guidewire that combines nitinol and stainless steel in a new and unique symmetrical design. The nitinol core contributes to high performance maneuverability and kink resistance, while the stainless steel shaft offers strength and improved pushability. The result is impressive torqueability and steerability so you reach lesions successfully and easily, and then perform standard PCI/stent device delivery with the same wire. Superior connectivity Opsens Medical s unique connector technology combines the two main elements for establishing and maintaining a reliable connection a robust connecting mechanism and the outstanding performance of Opsens optical technology. This optical link connection is easy to use, and its immunity to the effects of blood and contrast agents enable OptoWire One to maintain a consistent connection while achieving reliable FFR assessments. 1:1 Optical Fiber Torque Transfer Optical sensing for reliable pressure measurement Optimized for multiple lesions assessment Opsens Medical has been a pioneer in advanced fiber optic sensing technology for more than a decade, and our pressure sensor has been used in critical life support cardiovascular applications. Our unique sensor design is not affected by blood and temperature shift, delivering high fidelity pressure measurement with remarkable consistency. In fact, our pressure sensor is without equal when it comes to accuracy, long-term reliability and signal stability. With driftless pressure sensing, workhorse guidewire construction and highly reliable connectivity, OptoWire One can reliably perform FFR in multiple lesions, before and after PCI or stenting.
Easy cath lab integration Many hemodynamic systems now integrate FFR functionality for more efficient patient data consolidation. Opsens OptoMonitor can be connected directly to the cath lab hemodynamic system to display FFR directly on the cath lab monitor. OptoMonitor offers an intuitive display with easy navigation, and the option for USB data storage or FFR paper printout. The small footprint requires minimal space, which enables permanent installation and perpetual system availability. Simple integration OptoMonitor integrates with your existing hemodynamic system via a BP22 compatible output. It is easy to perform the initial setup, and it is ready to use anytime without further adjustments. Permanently installed The compact, rugged and lightweight design permits installation in the cath lab, and can easily be mounted on a bed or IV pole. Similar FFR workflow Conforms to your current FFR step-by-step functions. See the possibilities for yourself If you re seeking a way to easily navigate the coronary arteries reaching lesions with ease, accurately measuring intra-coronary blood pressure at all points, placing stents and performing post-assessment FFR all with the same wire, it is time you had a demonstration of OptoWire One. Intuitive workflow Logical workflow from left to right, with a visual indication to confirm completion of each task. Data integration FFR measurements are displayed on the OptoMonitor, and measurements can be saved to a USB key. For more information and a demonstration of Opsens Medical technology, please call 418-682-9996, or visit www.opsensmedical.com.
OptoWire One Optimized for multiple lesions assessment Reliable optical sensing technology Innovative guidewire construction with a nitinol core High performance maneuverability Perform PCI or stent placement without replacing the wire Conduct post-pci and post-stent assessment Medical Interventional cardiology in a whole new light #125, 2014, Cyrille-Duquet St. Quebec, Quebec G1N 4N6, Canada T: 418.682.9996 F: 418.682.9939 www.opsensmedical.com