Moxa PoE Media Converter



Similar documents
Moxa EtherDevice Switch

IMC-101 Series Hardware Installation Guide

MOXA EtherDevice Switch

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

8-port 10/100Base-TX +2-port 100Base-FX Switch. User s Guide

5-port 10/100Base-TX Industrial Switch (314500) User s Guide

Gigabit Switching Ethernet Media Converters - Product User Guide

HARTING econ 3000 Introduction and features

NS-205-IP67 5-Port Industrial 10/100 Mbps Ethernet Switch with IP67 Casing

HP ProCurve High-Speed Transceivers Installation Guide

Copper to Fiber Stand-Alone Media Converter. Quick Installation Guide

Perle 10/100 Ethernet Media Converters

8-Port PoE Network Switch

XPress-Pro SW Series Hardened Ethernet Switches Enabling Communication for the Demanding Industrial Environment

M7250P. PoE Powered. Gigabit Ethernet Media Converter 1000BASE-TX TO 1000BASE-SX/LX. Installation Guide

EDR-G903 Series. Industrial Gigabit Firewall/VPN secure router. Introduction. Specifications. Industrial Ethernet Solutions

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Ethernet Switch Wide Temperature

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

USER MANUAL MODEL 2300M SERIES. OpticLink Ethernet Media Converters (2300M, 2310M, 2311M, & 2312M)

Perle 10/100/1000 Ethernet Media Converter Module

Provides one channel for Ethernet over existing

IES-3080/3062 Series. Industrial 8-port managed Ethernet switch. Features. Introduction

Industrial 10/100/1000BASE-T to 100/1000BASE-X SFP Media Converter

DES-1005P 5-Port 10/100Mbps with 1-Port PoE Unmanaged Switch

IFS MC251-4P/1S and NS2051-4P/1T User Manual

Quick Installation Guide 24-port PoE switch with 2 copper Gigabit ports and 2 Gigabit SFP ports (af Version 15.4W)

Provides one channel for Ethernet over existing

MICROSENS Media Converter 10/100/1000T to Gigabit Fiber

ConneXium Ethernet Switches TCSESU0 F N0 Quick Reference Guide

User Guide. MC100CM MC110CS Fast Ethernet Media Converter. MC111CS MC112CS WDM Fast Ethernet Media Converter

1Industrial Ethernet Switch

Perle Protocol Transparent Media Converter Modules

4-Port 10/100Mbps with PoE + 1-Port 100FX Industrial Web Smart Switch

GEU Port Gigabit Switch

Prisma Optical Media Converters Industrial Ethernet 10/100 Switching Mini Media Converters

MDI/MDIX) FEP-32008T-3

TrueAlarm Fire Alarm Systems

FSW-0505TX/0805TX 5/8 Port SOHO 10/100Mbps NWay Switch FSW-0505TX FSW-0805TX. 5/8 Port SOHO 10/100Mbps NWay Switch. User s Manual. (Revision 1.

Media Converters & Chassis

ALL8808POE. 8 Port Gigabit PoE+ Switch. Manual

PoE+ Extender Switch User's Manual. Rev W

Media Converters & Chassis

10/100/1000 Base-T to Gigabit Fiber Media Converter

USER S MANUAL. Ethernet 10/100 Transceiver Series DL221/DL221A

Perle Fast Fiber to Fiber. Media Converters

palm Switch Port 10/100 Base-TX Switch with Auto MDI/MDI-X User Guide

FCC COMPLIANCE STATEMENT

AT-GS2002/SP. Gigabit Ethernet to Fiber SFP Media Converter. AT-GS2002/SP Media Converter Installation Guide. PN Rev. A

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

Perle Gigabit Fiber to Fiber Media Converters

FlexPoint T1/E1 Copper to Fiber Line Driver

EKI port Industrial Unmanaged Gigabit Ethernet Switch. User Manual

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

EKI port 10/100Base-TX Industrial Unmanaged Ethernet Switch. EKI port 10/100Base-TX Industrial Unmanaged Ethernet Switch.

Gigabit eco-friendly Ethernet Switch AT-GS900/8. Installation Guide Rev. A

4-Port 10/100Base-TX with PoE + 1-Port BNC / RJ-11 Industrial Ethernet Extender

USER GUIDE. 2 Channel POTS Mux DIN Fiber Link System. Introduction SYSTEM INSTALLATION INFORMATION. The leader in rugged fiber optic technology.

IFS SP-PoE Splitter User Manual

HARTING mcon 1000 Introduction and features

Full_IG.book Page 1 Monday, January 9, :11 PM. ProSafe 24 Port Gigabit Switch Installation Guide

FriendlyNET FX Slot Modular Switch. User s Manual

IKS PoE Series. 24+4G-port Gigabit modular managed PoE+ Ethernet switches. Introduction. Industrial Ethernet Solutions. Features and Benefits

Cisco MFE and MGE SFP Transceivers Cisco Small Business Network Accessories

User's Manual. 8-Port 10/100Mbps with 4-Port PoE Fast Ethernet Switch FSD-804P - 1 -

Moxa TCC-100/100I User s Guide

8-Port 10/100Mbps 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch

My first Hirschmann: The SPIDER family of switches.

Portable BACnet /IP to MS/TP Router

8-Port 10/100Mbps 802.3af / 802.3at PoE + 1-Port 10/100/1000Mbps Desktop Switch. FGSD-910P / FGSD-910HP User s Manual

Fast Ethernet FX-TX Media Converter. User Manual RINGDALE

RGPS-7084GP-P. Industrial 12-port rack-mount managed Gigabit PoE Ethernet switch with 8x10/100/1000Base-T(X) P.S.E. ports and 4x1000Base-X, SFP socket

10 Port L2 Managed Gigabit Ethernet Switch with 2 Open SFP Slots - Rack Mountable

MICROSENS. Installation Switch with PoE (5x10/100Base-TX) and fiber uplink (1x100Base-FX) General. Features

2G-1.1.0, 200M-2.0.3, 200M-1.0.1

Your single source for network transmission solutions.

8-Port 10/100M N-Way Mini Switch

ProCurve Switch 2500 Series

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

D-Link DES-1024D 24-Port 10/100Mbps Ethernet Switch. Manual

ProCurve Switch 1400 Series

Cisco Unmanaged Rackmount Switches

Megapixall Security Tools & Accessories

MCR1900 Media Converter 19-Slot Chassis

USER MANUAL. PingBrother EPIW104 managed passive poe switch & IP watchdog

Single Port Gigabit Ethernet Media Converter Board (P/N xxx) User s Manual And Troubleshooting Guide

Long Reach PoE over Coaxial Extender Kit

LBNP RS-232/485/422 serial device server. User manual

8 Port Gigabit 10M/100M/1000M Fast Ethernet Switch. User Manual

GS110TP Hardware Installation Guide

Start Here. Features. Model EN104/EN108/EN116 Ethernet Hub Installation Guide

AXIS T81B22 DC 30W Midspan

Supports O-Ring (recovery time < 30ms over 250 units of connection) and MSTP(RSTP/STP compatible) for Ethernet

2-Port Gigabit Ethernet Switch Operations Guide

LFH4-M/LFH8-M Mini Fast Hubs. Installation Guide

VDSL Ethernet LAN Extender

OPT SERIAL TO FIBER OPTIC CONVERTER

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Transcription:

Moxa PoE Media Converter IMC-P101 Hardware Installation Guide First Edition, November 2009 2009 Moxa Inc. ll rights reserved. Reproduction without permission is prohibited. Fl.4, No.135, Lane 235, Pao-Chiao Rd. Shing Tien City, Taipei, Taiwan, R.O.C. TEL: +886-2-8919-1230 P/N: 1802001015010

Overview The IMC-P101 series is an Ethernet to fiber optic media converter. It provides Ethernet media conversion from 10/100 BaseT(X) to 100 BaseFX(SC/ST connectors). These media converters are classified as power source equipment (PSE), and when used in this way, the IMC-P101 series provides up to 15.4 watts to powered devices (PD). The IMC-P101 series can be used to power IEEE 802.3af compliant powered devices (PD), eliminating the need for additional wiring, and supports IEEE 802.3/802.3u/802.3x with 10/100M, full/half-duplex, and MDI/MDI-X auto-sensing to provide a total solution for your industrial Ethernet network. The IMC-P101 Series includes the following models: IMC-P101-M-SC: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, multi-mode port with SC connector, 0 to 60 C operating IMC-P101-M-ST: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, multi-mode port with ST connector, 0 to 60 C operating IMC-P101-S-SC: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, single-mode port with SC connector, 0 to 60 C operating IMC-P101-S-ST: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, single-mode port with ST connector, 0 to 60 C operating IMC-P101-M-SC-T: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, multi-mode port with SC connector, -40 to 75 C operating IMC-P101-M-ST-T: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, multi-mode port with ST connector, -40 to 75 C operating IMC-P101-S-SC-T: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, single-mode port with SC connector, -40 to 75 C operating IMC-P101-S-ST-T: PoE Industrial 10/100BaseT(X) to 100BaseFX media converter, single-mode port with ST connector, -40 to 75 C operating NOTE Throughout this Hardware Installation Guide, we often use IMC as an abbreviation for Moxa Industrial Media Converter: IMC = Moxa Industrial Media Converter - 2 -

Package Checklist Moxa PoE Media Converter is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. IMC-P101 series media converter. Hardware Installation Guide (printed). Warranty Card. Features 10/100BaseT(X) uto-negotiation and uto-mdi/mdi-x. IEEE 802.3af compliant PoE. Power failure by relay output. Provides up to 15.4W of power to powered devices (PD). Support Store-and-Forward mode and Pass Through mode. -40 to 75 C operating temperature range (T models). Redundant dual VDC power inputs. - 3 -

Panel Layout of the IMC-P101 Series 1 2 4 Top Panel View Front Panel View (IMC-P101-M-ST) 2 5 7 8 9 10 13 Rear Panel View 3 6 11 12 1. Grounding screw 2. Terminal block for power input PWR1/PWR2 3. Heat dissipation vents and relay output 4. DIP switch 5. Power input PWR1 LED 6. Power input PWR2 LED 7. Fiber Link/ctive LED 8. 100BaseFX (ST/SC connector) Port 9. PSE Indicator LED 10. 10/100BaseT(X) 11. TP port 10 Mbps LED 12. TP port 100 Mbps LED 13. Model Name 14. Screw hole for wall mounting kit 15. DIN-Rail mounting kit 14 15 14-4 -

Mounting Dimensions 42.4 mm (1.67 in) 40 mm (1.57 in) 135.1 mm (5.32 in) 144.45 mm (5.69 in) IMC-P101-M-SC 12.06 mm (0.47 in) 101.4 mm (3.99 in) 110.2 mm (4.34 in) 51.65 mm (2.03 in) Side View Front View 40.8 mm (1.61 in) 30.5 mm (1.2 in) 54 mm (2.13 in) 67 mm (2.64 in) 39.84 mm (1.57 in) 34 mm (1.34 in) 51.6 mm (2.03 in) Rear View Panel Mounting Kit (Optional) - 5 -

DIN-Rail Mounting The aluminum DIN-Rail attachment plate should be fixed to the back panel of the IMC when you take it out of the box. If you need to reattach the DIN-Rail attachment plate to the IMC, make sure the stiff metal spring is situated towards the top, as shown in the figures below. STEP 1: Insert the top of the DIN-Rail into the slot just below the stiff metal spring. metal spring STEP 2: The DIN-Rail attachment unit will snap into place as shown below. metal spring DIN-Rail DIN-Rail To remove the Moxa Industrial Media Converter from the DIN-Rail, simply reverse Steps 1 and 2 above. Wall Mounting (Optional) For some applications, you will find it convenient to mount the Moxa PoE Media Converter on the wall, as illustrated below. STEP 1: Remove the aluminum DIN-Rail attachment plate from the Moxa PoE Media Converter, and then attach the wall mount plates, as shown in the diagrams below. Top plate Bottom plate - 6 -

STEP 2: Mounting the Moxa PoE Media Converter on the wall requires 4 screws. Use the IMC, with wall mount plates attached, as a guide to mark the correct locations of the 4 screws. The heads of the screws should be less than 6.0 mm in diameter, and the shafts should be less than 3.5 mm in diameter, as shown in the figure at the right. NOTE Test the screw head and shank size by inserting the screw into one of the keyhole shaped apertures of the Wall Mounting Plates, before it is screwed into the wall. 3.5 mm 6.0 mm Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the wall and the screws. STEP 3: Once the screws are fixed in the wall, insert the four screw heads through the large openings of the keyhole-shaped apertures, and then slide Moxa PoE Media Converter downwards, as indicated below. Tighten the four screws for added stability. Grounding the Moxa Industrial Media Converter Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the ground connection from the ground screw to the grounding surface prior to connecting devices. TTENTION This product is intended to be mounted to a well-grounded mounting surface such as a metal panel. - 7 -

Wiring the Redundant Power Inputs The top five contacts of the 8-contact terminal block connector on the IMC s top panel are used for the IMC s two DC inputs. Top and front views of one of the terminal block connectors are shown here. Top View STEP 1: Insert the negative/positive DC wires into the V-/V+ terminals. Front View STEP 2: To keep the DC wires from pulling loose, use a small flat-blade screwdriver to tighten the wire-clamp screws on the front of the terminal block connector. STEP 3: Insert the plastic terminal block connector prongs into the terminal block receptor, which is located on the IMC s top panel. TTENTION Before connecting the IMC to DC power inputs, make sure the DC power source voltage is stable. Communication Connections IMC-P101 models have one 10/100BaseT(X) Ethernet port, and one 100BaseFX (SC or ST type connector) fiber port. 10/100BaseT(X) Ethernet Port Connection The 10/100BaseT(X) Ethernet port located on the IMC s front panel is used to connect to Ethernet-enabled devices. Illustrated below are pinouts for both MDI (NIC-type) ports and MDI-X (HUB/Switch-type) ports, and also cable wiring diagrams for straight-through and cross-over Ethernet cables. RJ45 (8-pin, MDI) Port Pinouts RJ45 (8-pin, MDI-X) Port Pinouts Pin Signal Pin Signal 1 2 3 6 Tx+ Tx- Rx+ Rx- 1 8 1 2 3 6 Rx+ Rx- Tx+ Tx- 1 8-8 -

RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring Switch Port RJ45 Connector Tx+ Tx- Rx+ Rx- Straight-Through Cable RJ45 Plug Pin 1 Cable Wiring 3 3 6 6 1 1 2 2 NIC Port RJ45 Connector Rx+ Rx- Tx+ Tx- RJ45 (8-pin) to RJ45 (8-pin) Cross-Over Cable Wiring Switch Port (NIC Port) RJ45 Connector (Rx+) (Rx-) (Tx+) (Tx-) Tx+ Tx- Rx+ Rx- Cross-Over Cable RJ45 Plug Pin 1 Cable Wiring 3 1 6 2 1 3 2 6 Switch Port (NIC Port) RJ45 Connector Rx+ Rx- Tx+ Tx- (Tx+) (Tx-) (Rx+) (Rx-) 100BaseFX Ethernet Port Connection The concept behind the SC port and cable is quite straightforward. Suppose you are connecting devices I and II. Unlike electrical signals, optical signals do not require a circuit in order to transmit data. Consequently, one of the optical lines is used to transmit data from device I to device II, and the other optical line is used transmit data from device II to device I, for full-duplex transmission. ll you need to remember is to connect the Tx (transmit) port of device I to the Rx (receive) port of device II, and the Rx (receive) port of device I to the Tx (transmit) port of device II. If you are making your own cable, we suggest labeling the two sides of the same line with the same letter (-to- and B-to-B, as shown below, or 1-to-2 and B1-to-B2). SC-Port Pinouts SC-Port to SC-Port Cable Wiring Tx B B Cable Wiring Rx B B ST-Port Pinouts ST-Port to ST-Port Cable Wiring - 9 -

Tx B B Rx B Cable Wiring B TTENTION This is a Class 1 Laser/LED product. Do not stare into the Laser Beam. Redundant Power Inputs Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other live source acts as a backup, and automatically supplies all of the Moxa Industrial Media Converter s power needs. DIP Switch Setting ON DIP 1 2 3 4 5 6 7 DIP No. Function ON OFF 1 uto Negotiation Enable* Disable ON : Enables uto Negotiation function, the speed and duplex states for each port link segment are automatically configured using the highest performance interoperation mode. OFF : Disables uto Negotiation function, the speed and duplex states depend on the manual setting configuration. 2 Force TP Speed 100Mbps* 10Mbps (Only when uto Negotiation is disabled) ON : Forces 100Mbps on Ethernet port. OFF : Forces 10Mbps on Ethernet port. 3 Force TP Duplex Full Duplex* Half Duplex (Only when uto Negotiation is disabled) ON : Forces Full Duplex on Ethernet port. OFF : Forces Half Duplex on Ethernet port. 4 Link Fault Pass Through Enable* Disable ON : Enables Link Fault Pass Through, the link status on the TX port will inform the FX port of the same device and vice versa. OFF : Disables Link Fault Pass Through, the link status on the TX port will not inform the FX port. 5 Operating Mode Store-and-Forward* Pass Through - 10 -

DIP No. Function ON OFF ON : Selects Store-and-Forward mode, begins to forward a packet to a destination port after an entire packet is received. The latency depends on the packet length. OFF : Selects Pass Through mode, operates with the minimum latency. Both transceivers are interconnected via internal MIIs and the internal switch engine and data buffer are not used. Note: With Pass Through mode enabled, the Ethernet port and fiber port should transmit at 100 Mbps, which is equivalent to full duplex mode. 6 PSE Disable Enable* PSE: Power Source Equipment. ON : Disables PSE, IMC-P101 series do NOT provide power to PD (Powered Device). OFF : Enables PSE, IMC-P101 series provides power to PD (Powered Device). 7 P.R.R. Enable Disable* P.R.R.: Power Remote Reset ON : Enables P.R.R function, when fiber port link down 3 seconds and PSE setting is enabled, IMC-P101 series STOP providing power to PD (Power Device) which means the PD power will turn OFF. fter 1 second later, IMC-P101 series start to continue provide power to PD, and then the PD power turn back ON for reset PD. OFF : Disables P.R.R function, no reset PD function. (*): Default DIP switch setting. TTENTION fter changing the DIP switch setting, you will need to power off and then power on the IMC-P101 to activate the new setting. LED Indicators The front panel of Moxa Industrial Media Converter contains several LED indicators. The function of each LED is described in the table below. LED Color State Description PWR1 Green ON Power is being supplied to power input PWR1 OFF Power is not being supplied to power input PWR1 PWR2 Green ON Power is being supplied to power input PWR2 OFF Power is not being supplied to power input PWR2 ON Fiber port is active. Fiber Green Blinking Data is being transmitted or received. Link/ct OFF Fiber port is inactive. PSE Green ON PSE is enabled. Indicator 1 Flash Low Signature Resistance 2 Flash High Signature Resistance - 11 -

10M 100M Yellow Green Specifications Technology Standards Interface RJ45 ports Fiber ports LED Indicators 5 Flash Power overload Fault 9 Flash Power Management llocation Exceeded ON Ethernet port 10 Mbps link is active. Blinking Data is being transmitted at 10 Mbps. OFF Ethernet port 10 Mbps link is inactive. ON Ethernet port 100 Mbps link is active. Blinking Data is being transmitted at 100 Mbps. OFF Ethernet port 100 Mbps link is inactive. IEEE 802.3 for 10BaseT, IEEE 802.3u for 100BaseT(X), 100BaseFX IEEE 802.3af for Power-over-Ethernet 10/100BaseT(X) 100BaseFX (SC, ST connectors available) PWR1, PWR2, Fiber Link/ct, 10/100M (Ethernet port), PSE Indicator DIP Switches: Dip No. Function ON OFF 1 uto Negotiation Enable* Disable 2 Force TP Speed 100Mbps* 10Mbps 3 Force TP Duplex Full Duplex* Half Duplex 4 Link Fault Pass Through Enable* Disable 5 Operating Mode Store-and-Forward* Pass Through 6 PSE Disable Enable* P.R.R. 7 (PD Remote Reset) (*): Default DIP switch setting. Enable Disable* larm Contact One relay output with current carrying capacity of 1 @ 24 VDC Optical Fiber 100BaseFX Multi-mode Single-mode Wavelength 1300 nm 1310 nm Max. TX -10 dbm 0 dbm Min. TX -20 dbm -5 dbm RX Sensitivity -32 dbm -34 dbm Link Budget 12 db 29 db Typical Distance 5 km a 4 km b 40 km c Saturation -6 dbm -3 dbm - 12 -

a. 50/125 μm, 800 MHz*km fiber optic cable b. 62.5/125 μm, 500 MHz*km fiber optic cable c. 9/125 μm, 3.5 PS/(nm*km) fiber optic cable Physical Characteristics Housing Metal Dimensions (W x H x D) 144.45 x 110.2 x 51.65 mm (5.69 x 4.34 x 2.03 in) Weight Product only: 525g Packaged: 710g Installation DIN-Rail mounting, Wall Mounting (optional kit) Environmental Limits Operating Temperature Standard Models: 0 to 60 o C (32 to 140 o F) Wide Temp. Models: -40 to 75 o C (-40 to 167 o F) Storage Temperature -40 to 85 o C (-40 to 185 o F) mbient Relative 5 to 90% (non-condensing) Humidity Power Requirements Input Voltage 48VDC (46 to 57 VDC), redundant inputs Power Consumption 430m@48VDC (max.) Connection Removable terminal block Overload Current Protection 1.6 (protects against two signals shorted together) Reverse Polarity Protection Present Regulatory pprovals Safety UL508 EMI FCC Part 15, CISPR (EN55022) class EMS IEC 61000-4-2 Edition 1.2: 2001-04(Level 4) EN 61000-3-3: 1995 + 1: 2001 IEC 61000-4-3: 2002+1: 2002(Level 3) IEC 61000-4-4: 2004(Level 4) IEC 61000-4-5 Edition 1.1: 2001-04(Level 3) IEC 61000-4-6 Edition 2.1: 2004-11(Level 3) IEC 61000-4-8 Edition 1.1: 2001-03(Level 3) IEC 61000-4-11 Second Edition: 2004-03 Shock IEC 60068-2-27 Free Fall IEC 60068-2-32 Vibration IEC 60068-2-6 Warranty Warranty Period 5 years Details: See www.moxa.com/warranty - 13 -

Technical Support Contact Information www.moxa.com/support Moxa mericas: Toll-free: 1-888-669-2872 Tel: +1-714-528-6777 Fax: +1-714-528-6778 Moxa China (Shanghai office): Toll-free: 800-820-5036 Tel: +86-21-5258-9955 Fax: +86-10-6872-3958 Moxa Europe: Tel: +49-89-3 70 03 99-0 Fax: +49-89-3 70 03 99-99 Moxa sia-pacific: Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 - 14 -