Innovative. Lum. Flux** [lm]



Similar documents
IVIOS LED III. LUM Technical Information

Why Philips LEDtube? LED Lamps EMEA February February 2015_BG LS & E LEDlamps

Radiance Angle [ ] Nominal Power [W] Color Temp. [K]

Flux CCT. CRI SDCM (lm) (K) (V) (ma) (W) (lm/w)

Nominal Power [W] Radiance Angle [ ] Color Temp. [K]

Radiance Angle [ ] Color Temp. [K]

T5 LongLast. GE Lighting DATA SHEET

OSRAM DULUX SUPERSTAR MICRO TWIST

Product Information. LED SUPERSTAR MR Adv. Product Overview. Benefits. Key Features

LED SUPERSTAR MR Product description

The most sustainable lighting solution. QL 85W Induction Lighting System

PLVZ1-LIN DC > , PLVZ1-LIN DC > ,

Delightful light.

ECOPTIMO T8. Version IRIS 2002,S.A. C/San Agustin, Madrid SPAIN T F

Why Philips LEDtube? Leander Bloot Product marketing LEDtubes LED Lamps EMEA January January 2014_BG LS & E LEDlamps

The new generation of energy saving tube lighting

QLT1500GB (120 ) QLT1500GH (60 ) 18W

Product Overview. & clear sparkling. Key Features. mm 150 g mm 150 g

DULUX L 55 W/840 2G11

T5 Watt-Miser Linear Fluorescent lamps

Product Information LED PARATHOM PAR Product Overview. Benefits. Key Features

Technical application guide

KIT DOWNLIGHT HALOSPOT 111 ES

2013 / ZCI DOC-00 OSRAM GmbH Marcel-Breuer-Str München Germany. OSRAM LED module DC24B-XXXX. IEI See attached list

Downsize your downlighting costs with LED PLC. The first retrofit LED PLC lamp designed to increase efficiency and downsize your costs.

Biax T/E. Triple Biax Compact Fluorescent Lamps Non-Integrated 13W, 18W, 26W, 32W and 42W. GE Lighting. Product description.

The right. LEDtube. every time. LEDlamps

Product Overview. & clear sparkling. Key Features. mm 150 g mm 150 g

LED Tubular Lamp / Kit Guide

DETAS -DLEDS Division

How To Make A Light Bulb From An Osmram Dulux Lamp

EC-Declaration of Conformity Annex

E-CORE LED WEATHERPROOF 2 DATA SHEET 1 / 5. Application:

Lumination LED Luminaires

Technical Specification

COOL Shelf Quick Connect

Fortimo LED Line Gen3

High / Low Bay Datasheet

2015 / 9C DOC-01 OSRAM GmbH Marcel-Breuer-Str München Germany. Lamp controlgear HTi DALI 105/

High / Low Bay Datasheet

DuroSite TM High Bay Lighting

FREEZE Canopy. Canopy lighting. QCS Quick-Connection-System. Daylight. Neutral White. Fresh Meat. Packed Meat

LIGHTING and LIGHTING SYSTEMS

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Biax S and S/E. Compact Fluorescent Lamps Non-Integrated 5W, 7W, 9W and 11W. GE Lighting DATA SHEET. Product information. Features.

Low / High Bay Datasheet

Operating instructions IV / 2007

Energy meets efficiency

Linear Luminaire with LED Series EXLUX 6402/2

Light is powerful Siteco Floodlight 20 maxi LED.

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

GE Lighting. Lighting the future. Your guide to changing to energy efficient lamps

LED light engine / OLED LED linear / area. Umodule STARK QLE G3 lens CLASSIC umodule QLE

Features. High Brightness LED Light source

High / Low Bay Datasheet

E-CORE Candle 6W. Data Sheet 1 / 5

SAMSUNG ELECTRONICS LED

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

KATO. LED Lighting High Bay und Low Bay

Philips MASTER LEDlamps 1st quarter See what light can do.

MASTER LEDluster. MASTER LEDluster D 4-25W E14. Product data

Kolorlux. GE Lighting DATA SHEET

LINEAR SYSTEM 3000K 4000K 5000K 6000K 7000K

Low Bay High Bay. Lighting. Industrial Series. The best lighting level for better working performance.

Lumination LED Luminaires

Recessed. EvoKit LED Retrofit Kits Gen 3

T8 1200mm LED Tube 18 W FICHA TÉCNICA (1/5)

120W High Bay II Datasheet

EDGE Park / R Mounting R recessed

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

LED RETROFIT OPTIONS FOR LINEAR FLUORESCENT LUMINAIRES

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC / CLE CLASSIC umodule CLE

FLUORESCENT UV- RING LIGHT OPERATING INSTRUCTION

A Guide to the Specification of LED Lighting Products 2012

9W T8 LED TUBE 2FT GENERAL INFORMATION

Downlights Panels Floodlights Lowbay Highbay Streetlights Tubes Induction Linear

Led lighting products

Brighter Choice... LED Lighting from Verbatim. Quality. Performance. Technology. Mitsubishi Chemical Holdings Group

illuminer 150W High/Low Bay Datasheet E Join the LED Revolution Solid-State Lighting Series

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

OSRAM DULUX promising a more efficient future. Average life of up to 36,000 hours: optimized OSRAM DULUX compact fluorescent lamps with plug-in bases.

LED Module SPECIFICATION. LED Module for Modular Platform Series. LED Platform Module with Fin

Dimensions in mm. S10 Starter in white canister. S2 Starter in white canister FLUORESCENT LAMPS & CONTROL GEAR 3.

High Pressure Mercury

Electronic ballasts for fluorescent lamps Products for special applications. PC BASIC, 4 28 W Electronic ballast for system output < 25 W

LED HIGHBAY COMMERCIAL & INDUSTRIAL DESIGNED MANUFACTURED AND WARRANTED IN AUSTRALIA

The professionals among lamps OSRAM DULUX energy-saving lamps: top performance for all professional applications

Lumination LED Luminaires

Fortimo LED SLM Gen4

Sento LED parete singolo up cutsheet

IEC Self-ballasted compact fluorescent lamps for general lighting services - performance requirements Contents

Technical application guide IP codes in accordance with IEC 60529

ENERGY SAVING CATALOGUE

GE Lighting. Albeo LED Luminaire. Linear Industrial Low Bay Lighting. (ALV1 - Series) imagination at work

Industrial plastic LED light fittings Industrial metal LED light fittings Emergency LED light fittings

The best for our customers The retail range of OSRAM DULUX energy-saving lamps

LED DIMMING A HELPFUL GUIDE...

Light is fl exible OPTOTRONIC Linear LED drivers. Light is OSRAM.

High / Low Bay PC Reflector Datasheet

Transcription:

www.osram.com SubstiTUBE Advanced ST8A-0.6m-8.9W-840-HF Datasheet Innovative LED-lamp, easy and safe to use in ECG installations as direct retrofit. Energy saving potential of up to 35% by replacing 0.6 m T8 fluorescent tubes. Instant 100% light without flickering. No mercury. Applicable in warehouses, cold storage, supply rooms, corridors, industry, stairways, garages, indirect illumination etc; for applications with high operating hours. Technical operating data* Product Color Colortemp. [K] Lum. Flux** [lm] Input current** [A] Power** [W] Radiance- Angle [ ] ST8A-0.6m-8.9W- 840-HF Cool White 4000 K 1100 lm 0.34 A 8.9 W 160 *All Data are related to the entire lamp. Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data. The overall efficiency and light distribution of any installations are determined by the design of the installation. **With reference ECG OSRAM QT FIT8 1x18 Technical Features LED lamp in T8 shape with G13 socket Length excl. pins: 590 mm Weight: 94g For operation with ECG Direct Retrofit for ECG luminaires; replacement of lamp No rewiring necessary at ECG Extremely robust due to polycarbonate body Fully integrated ECG complies to relevant standards Powerfactor: 0.8 Up to 50.000 h lifetime Switching cycles: 200.000 Color Rendering Index (CRI) > 80 Overpower, overheat and short circuit protected High color homogeneity RoHS-conformity, no mercury Not for operation with CCG, not dimmable Energy Efficiency Class: A+ Page 1 of 5

Minimum / Maximum ratings Operating temperature Tc Storage temperature Ts Ambient temperature Ta ST8A-0.6m -20 75 C -20... 80 C -20... 50 C Drawings Product l d ST8A-0.6m 590 mm 27.5 mm Page 2 of 5

Safety and Application notes Use SubstiTUBE Advanced HF in luminaires which do not have any starter. The SubstiTUBE Advanced HF is designed for general lighting service (excluding for example explosive atmosphere) and must not be damaged or operated in a damaged condition. Since only the lamp is replaced there is no constructive modification to the luminaire. The SubstiTUBE Advanced HF is compatible with ECGs of various brand manufacturers. For further information regarding the tested ECGs a compatibility list is available on www.osram.com/substitube-hf The compatibility list is based upon testing conducted by the manufacturer in a lab simulated environment, and the results can vary in certain field applications due to a number of factors. OSRAM does not take over any responsibility, warranty or liability that these results can also be achieved by using the devices under other conditions, or when using successor models of the tested devices, or different models of the same manufacturer. In case of non-observance observance of the instructions, safety risks like overheating of SubstiTUBE or ECG may occur in rare cases. The SubstiTUBE Advanced HF emits light only with a limited angle, not like a fluorescent tube with 360 output. This lamp may not be suitable for use in all applications where a traditional fluorescent lamp has been used. The temperature range of this lamp is more restricted. Due to the characteristic light distribution of the SubstiTUBE Advanced, the resulting luminaire light characteristic is likely to change. It is not guaranteed that e.g. standards for lighting at working places will be complied to after replacement. A photometric check of the installation is recommended. The luminous flux will change in dependency of used ballast. The effective energy savings depend on the efficiency of the luminaire setup to be replaced and should be considered individually in each case. The SubstiTUBE Advanced HF is protected according to IP20. Applications with external risk of moisture and dust can be served with an adequately protected luminaire. Photobiological Safety of lamps and lamp systems according to IEC 62471. Risk Group: Exempt The SubstiTUBE HF is designed for standard lamp-holders. Some lamp-holders, e.g. push-in fixing without a rotor are not suitable for the SubstiTUBE HF. Lampe suitable for high frequency operation (HF) Lamp not suitable for emergency operation Dimming not allowed Page 3 of 5

Installation Instructions for ECG Below an example for typical lamp holder types is described Make sure that the supply voltage is disconnected (1). Turn the conventional lamp 90 degrees (2) and take it out of the socket (3). Insert SubstiTUBE Advanced HF (4) into socket and locate into position by turning 90 (5). Activate tube by pushing the two safety buttons (6), (7). Connect SubstiTUBE Advanced HF to supply voltage (8). Check light emission direction (9). Page 4 of 5

Ordering guide Product name Light color EAN* S-Unit** ST8A-0.6m-8.9W- 840-HF Cool White / 4000 K 4052899943018 25 x 1 * EAN: Ordering number per single module ** S-Unit: Lamps per shipping unit Sales and Technical Support OSRAM GmbH Marcel-Breuer-Strasse 6 D - 80807 Munich Germany www.osram.com +49 (0)89 6213-0 Sales and technical support is given by the local OSRAM subsidiaries. On our world wide homepage all OSRAM subsidiaries are listed with complete address and phone numbers. Further Information www.osram.com/substitube-hf Page 5 of 5