Aperio Online System Description

Similar documents
Aperio Online. Aperio. Online Programming Application Manual. Aperio Online Quick Installation Guide, Document No: ST A, Date: 8 juli 2013

R&D Access Touch 3.1 User Manual Version 1.00 Public 1 (13) User Manual. Access Touch 3.1

Version Date Author Description Jpo First version Jpo FET output descriptions made clearer

Access Professional Edition Selection Guide

Allegion AD-300 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

CKM-EP2500, CKM-EP1501, and CKM-EP1502 Mercury Network Controllers

Functional Specification Document

EMBEDDED ACCESS CONTROL Hardware Installation Guide

IP Card Reader Interface User Manual

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

Ex15x //DATASHEET. Xs4 Mini. Cutting-edge design + Amazing technology:

ZME_WALLC-S Z-Wave Secure Wall Controller

Allegion PIM-400/485 and AD-400 Installation Application Note. 1.0 Hardware Requirements. 2.0 Software/Licensing Requirements

Electronic Access Control Solutions

Product Guide. Product Guide 2014 EMKA, Inc. Page 1 of 12

BigPond Wi-Fi 4G Advanced II AirCard 790S User Manual

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

BT LE RFID Reader v1.0

MANUAL Remote Programmer XM3

The Access Engine. Building Integration System - The Access Engine. Security Systems

Electronic Access Control Security. Matteo Beccaro HackInTheBox Amsterdam, May 27 th, 2016

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

Embedded Web Server. User Guide. General usage guide lines to the ISONAS Embedded Web Server available on all ISONAS PowerNet reader-controllers

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

Time Attendance V1.4

Digitus Biometrics Product Catalogue. Request a quote or design assistance by ing sales@digitus-biometrics.com or calling

TX3 Series TELEPHONE/CARD ACCESS SYSTEMS. System Introduction (Sales Training)

Edge Metrics Data Center User Manual

USB Card Reader Interface User Manual

TCP/IP Network Communication in Physical Access Control

Access Control Unit User s Guide

Installer and Admin App Guide

[FAQ] Troubleshooting Access Control Issues

Rev GSM base station. Installation instructions

Nokia E90 Communicator Using WLAN

NACCU Migrating to Contactless:

ACCESS CONTROL MANY FUNCTIONS. ONE SYSTEM. ONE CARD.

ACCESS CONTROL SYSTEM

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Schlage Utility Software. For Pidion BM-150 / BM-170 Devices User s Guide

A6210 WiFi USB Adapter ac USB 3.0 Dual Band User Manual

Secure My-d TM and Mifare TM RFID reader system by using a security access module Erich Englbrecht (info@eonline.de) V0.1draft

Access Control in Commercial Applications. Is the future of commercial building security built in, or bolted on? A discussion paper

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Telstra Wi-Fi 4GX Advanced III AirCard 810S User Manual

RFID MODULE Mifare Reader / Writer SL025B User Manual Version 1.4 Nov 2012 StrongLink

Time Attendance V1.0

INSTALLATION MANUAL XM3 Reader


SYMMETRY PRODUCT OVERVIEW

Telstra Pre-Paid 4G My Pocket Wi-Fi Ultimate User Manual

TT-RFID platform - Introduction

User Manual. BARKODES BİLGİSAYAR SİSTEMLERİ ARF Panel

SYMMETRY. DATASHEET ACCESS CONTROL Product Overview

Keep it Simple Timing

Configure WorkGroup Bridge on the WAP131 Access Point

PCS0100en Persy Control Services B.V. Netherlands

Versatility, reliability and expandability are the three main features that make the N-1000 one of the most popular access control panels ever.

AD-Series. Selection Guide

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

ACR880 GPRS Portable Smart Card Terminal

PRT3 Printer Module: ASCII Protocol Programming Instructions

PRT-CTRL-SE. Protege System Controller Reference Manual

BLUETOOTH SERIAL PORT PROFILE. iwrap APPLICATION NOTE

Quick Start Guide: Iridium GO! Advanced Portal

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

CipherLab 5100 Time Attendance Utility Manual

Using Contactless Smart Cards for Secure Applications

What is our purpose?

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

AirCard 785S Mobile Hotspot User Manual

Ensto Chago Master EVM300 and EVM500 Operational description

Surveillance System Using Wireless Sensor Networks

Model 2120 Single Port RS-232 Terminal Server Frequently Asked Questions

WUA Mbps Wireless USB Network Adapter

User s Manual for Fingerprint Door Control Software

Access to the Lift Data Menu is via The Challenger User Menu option - Program Door Data.

Modbus and ION Technology

Water Metering System SmartMeter Prepayment. SmartMeter Prepayment. Water Metering System

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

Property Description Allowable values (Bold indicates default value) automaticaly relock after an unlock operation. English, Spanish, French 1, 2, 3

Home Monitoring and Control service provided by Verizon Online LLC

USB Card Reader Configuration Utility. User Manual. Draft!

Remote Serial over IP Introduction on serial connections via IP/Ethernet

ELM Security System Electronic Locking & Monitoring

Technical Support Information

F11 User Manual. Version:1.0 Date:Jul. 2010

Doc 10. UTM Standards: Card Access Security System

Configuring Settings on the Cisco Unified Wireless IP Phone 7925G

USER MANUAL. VS-81H 8x1 HDMI Switcher MODEL: P/N: Rev 4

Cisco Unified Wireless IP Phone. Michael Gillespie. Release 1.4(1) IP Communications 7926G, 7925G-EX, 7925G, 7921G

ASSA ARX Security system. The complete access control and alarm system. ASSA ABLOY, the global leader in door opening solutions

Bidirectional wireless communication using EmbedRF

Using IDENT M System T with Modbus/TCP

Configuring Switch Ports and VLAN Interfaces for the Cisco ASA 5505 Adaptive Security Appliance

- BIOMETRIC. Tel : Website : marketing@litestar.com.sg

WPR400 Wireless Portable Reader

Transcription:

Aperio Online Aperio Online System Description Document No: ST-002326-B, Issue date: 4 August 2015 1 The global leader in Aperio Online Mechanical Installation Guide, Document No: ST-002326-PB, Date: Online System door Description opening solutions

2 Aperio Online System Description, Document No: ST-002326-PD Date: 4 August 2015

Table of Contents 1 Introduction...4 Purpose...4 Scope...4 Applicable products...4 Product availability...4 Aperio support in the EAC system...4 References...4 2 System Overview...5 The Aperio Online System...5 The Aperio Online concept...5 Installation and Configuration Tool...5 3 Aperio Online Functional Support...6 System components...6 Main system features...6 Remote unlock...6 Communication hub functions...6 Lock functions...6 AS100 Door Sensor functions...6 Alarm/event handling to EAC...6 Audit trail...6 Override credentials...7 Maintenance functions...7 Security...7 Communication protocols towards EAC...7 Software tool - Programming Application...7 4 Detailed feature descriptions...8 Credential technologies...8 Locks...8 Unlock times...8 Keypad support...8 Battery supervision...8 Battery replacement...8 RTC time drift...8 Status report interval...8 Communication hubs...9 EAC addressing features (RS-485)...9 Addressing alternatives...9 Different EAC addressing modes...9 Remote Unlock use cases...10 Office Mode/First Man In...10 Scheduled relock...10 Remote unlock...10 Remote unlock configuration...10 Audit trails...10 Aperio Online System Description, Document No: ST-002326-B Date: 4 August 2015 3

1 Introduction Purpose The main purpose of this manual is to provide necessary information to plan and perform the mechanical installation of Aperio communication hubs. Intended reader is installation personnel, project managers and people with similar responsibilities. Scope This manual includes a complete description of an Aperio Online system and its integration to surrounding systems. For a description of Aperio Online system components refer to ref [1], Aperio Online Mechanical Installation Manual and ref [2], Aperio Programming Application Manual. Applicable products This manual can be used for all versions of communication hubs Product availability The products included in this manual may not be available on all markets. Please check your local ASSA ABLOY company for details. Aperio support in the EAC system Note that the Aperio support may vary depending on the Aperio communication hub used and the level of integration. Please contact your OEM for details. Abbreviations and definitions Abbreviation Definition EAC DIP RFID TLS OEM Electronic Access Control. The system controlling access decisions. Dual in-line Package. A manual electric switch used for settings on the communication hub. Radio Frequency Identification. The credential technology used. Transport Layer Security. Cryptographic protocol that provides secure communication over TCP/IP connections. Original Equipment Manufacturer, the company that integrates the Aperio support in their EAC system. References [1] ST-001323-Aperio Online Mechanical Installation Manual [3] ST-001321-Aperio Online Programming Application Manual [2] ST-001322-Aperio Online Quick Installation Guide [2] 4 Aperio Online System Description, Document No: ST-002326-PD Date: 4 August 2015

2 System Overview Figure 1. Aperio technology overview Programming Application Offline updater IEEE802.15.4 (2.4GHz) Communication Hub RS-485, Wiegand or Ethernet USB RFID card RFID card EAC system (Electronic Access Control) Aperio OFFLINE Aperio ONLINE The Aperio Online System Aperio Online is a technology that enables mechanical locks to be connected wirelessly to an existing access control system in a convenient and cost effective manner. The main feature is the use of a wireless short distance communication protocol for communication with locks and a wired connection to an online access control system. Aperio is easy to integrate with most devices and systems, regardless of manufacturer, as it has a large integrated base. Different mechanical standards and RFID technologies are supported to provide a solution for most markets. The Aperio Online concept The Aperio system is used in the following way: The user holds an RFID card in front of an online lock and/or enters a PIN. The lock sends credentials or PIN wirelessly to the communication hub which in turn communicates with an EAC (Electronic Access Control) system (wired through RS-485, Wiegand or TCP/IP). The EAC system makes the access decision. The decision is sent via the communication hub to the lock and access is granted or denied. Installation and Configuration Tool A software tool, the Aperio Programming Application is used for installation and configuration, which connects to the communication hub wirelessly with a USB radio dongle. The software can also connect directly to locks using a standard USB cable. Aperio Online System Description, Document No: ST-002326-B Date: 4 August 2015 5

3 Aperio Online Functional Support System components Communication hub: Wireless connection point (IEEE 802.15.4) connected to overlaying EAC (RS-485, Wiegand or TCP/IP). It communicates with Aperio online locks with a range of typically 25 m/80 ft. Lock Unit/Door Sensor: Supports all Aperio Online variants. Equipped with an RFID card reader/writer or keypad and a UHF transceiver. Door sensor AS100 also supported. Card formats for different RFID technologies: Aperio Online supports MIFARE Classic/Plus/ DESFire EV1, Legic, iclass, Low Frequency (EM/HID Prox), Seos and HID SE credentials, depending on lock unit used. Programming Application: Installation and maintenance tool that connects wirelessly to the communication hubs (and further on to locks) via a USB radio dongle. Main system features Remote unlock Several options to keep the door unlocked for a longer period of time, either user activated or remotely from the EAC system. Available for RS-485, Wiegand and TCP/IP. Communication hub functions Supports RS-485, Wiegand and TCP/IP. Connect up to 8 locks per communication hub (AH30/40). Different modes of device addressing (RS-485) towards the EAC. Digital/manual setting of EAC address. Automatic/manual pairing with locks/senors. Lock functions Configurable LED & buzzer handling for card read indication. Configurable lock open/close handling and timeouts. Emergency opening (product specific). Escape and return, configurable (product specific). Battery supervision. Configurable RFID search priority (V2 SE locks only). Keypad support, configurable. The lock can indicate lock status, access decisions, alarms and EAC and communication hub status with a LED supporting three colors. Battery life up to 40000 openings depending on product, use and configuration. Lock sensor support such has door position, handle, bolt etc (Product specific) AS100 Door Sensor functions Magnetic/mechanical circuit breaker for applications such as door position sensor or glass break sensor. Alarm/event handling to EAC Communication hub and/or lock offline Hub and lock tamper (product specific) Lock battery low, battery flat Lock jammed Device reset Door sensor events Audit trail Audit trail with 200 entries stored in case of lost contact to EAC system. 6 Aperio Online System Description, Document No: ST-002326-PD Date: 4 August 2015

Audit trails can be extracted with the software tool, Aperio Programming Application. Override credentials 10 positions for override/emergency cards or PIN when the lock/hub is offline from the EAC. Maintenance functions Up to 200 entries in event log. Firmware upgrade. Use of 3 radio channels that can be configurable. Security Encryption key During installation an encryption key customer key) should be used to apply secure communication between lock and communication hubs and also between communication hub and the software tool, making the Aperio hardware configurable only for the customer key owner. The key uses 128 bit AES encryption. Communication protocols towards EAC Wiegand Security as per the Wiegand standard. RS-485 No encryption on the interface. ASSA ABLOY AADP with is proprietary and open under NDA. OEM protocols HID VertX and Mercury are proprietary and closed. AADP IP Security over the TCP/IP interface is implemented using TLS. Software tool - Programming Application Installation and configuration of Aperio hardware are done with an Windows installation tool (Aperio Programming Application). USB radio dongle: UHF transceiver used by the programming application to communicate with communication hubs. Installation data is entered manually in the tool, and can be saved for reuse purposes, also exported/imported. Aperio Online System Description, Document No: ST-002326-B Date: 4 August 2015 7

4 Detailed feature descriptions Credential technologies The following credential types are supported by Aperio Online: Credential MIFARE Classic MIFARE Classic UID MIFARE Classic Sector MIFARE Plus UID MIFARE Plus Sector MIFARE DESFire UID MIFARE DESFire Application Low Frequency: HID Prox Low Frequency: EM PROX iclass Legic UID Legic UID with data Seos HID SE credentials PIN (via Keypad) Note: All credentials are not supported by all products. All card credential can be combined with a pin code. Locks Unlock times The unlock time for an Aperio lock can be controlled in several ways. There is a configurable default time in the lock. The unlock time can be controlled from the EAC per access decision and through the different "Remote Unlock" type of use cases. In addition a normal unlock time can be extended by double-badging the lock thus extending the open time by the same time used for the particular operation Keypad support This keypad function is product specific and supports two reading modes, PIN with configurable length or use of end character that also can be set. The Aperio keypad function does not send character per character, but a whole PIN to EAC, in order to save battery life. Battery supervision This function is product specific and is performed in the following two ways: Energy counter: Typically used on products that use lithium batteries of type CR123 and CR2. Battery life is calculated from measured energy consumption for each lock operation such as lock, unlock etc. It is therefore important to always use fully charged batteries during battery replacement to guarantee correct battery life measurement. At battery low, this type of product performs a minimum of 1000 lock operations before reaching battery flat. Battery measurement: Used on other products. Battery measurement is normally made at every lock operation and every time a status report is sent to the EAC (default every 60 minutes). Battery life is product and battery specific. The battery check interval can be set using the Aperio Programming Application. Battery replacement In Aperio readers there is a RTC maintaining the date and time. The time is typically set via the PAP tool or from the EAC if that system has the SetTime functionality implemented. When replacing the battery in an Aperio V2 device the RTC may lose the time and date and the time for how long the RTC can keep time when the batteries are out varies between the Aperio products. Therefore it is recommended to use the PAP tool to set time and after battery change. When replacing battery in an Aperio V3 device the RTC time is frozen and there will therefore be a time skew for the time it takes to replace the batteries. For Aperio Online the time and date is used for time stamp in audit trail and event logs. RTC time drift In Aperio V2 devices the RTC time drift is +/- 16 minutes/year on average and in in Aperio V3 devices the RTC time drift is +/- 13 minutes/ year on average. This should be considered in regards to battery replacement schemes and the requirement for accuracy in the audit trail time stamps. Status report interval This function enables configuration of how often the lock sends status report to the communication hub and EAC. At the time of a status report, updates from the EAC are also downloaded to the lock. This setting is default set to 60 minutes. Short time intervals will have a negative effect on battery life. However, when using remote unlock, this value is normally set to 5-15 minutes. 8 Aperio Online System Description, Document No: ST-002326-PD Date: 4 August 2015

Communication hubs There are four communication hub types according to the table below: Functional support Wireless technology EAC Interface Communication hub version AH15 AH20 AH30 AH40 Wiegand/RS-485* (AADP protocol Mercury) Advanced Wiegand RS-485 (AADP protocol HID VertX Mercury) IP (Ethernet) Maximum number of locks/ 1 1 8 8 sensors lock to hub Encryption key (Customer key) 128 bit AES encryption Encryption: hub to EAC None None None TLS EAC address limit (DIP/w PAP tool) 31/63-15 (one-to-several) 16-31/63 (single device mode) Typical range 5 m 25 m 25 m 25 m External antenna (option for alternate coverage pattern) No Yes Yes Yes Lock Keypad support Yes (RS-485) No Yes Yes Wiegand support Byte order Addition of parity bit - - Red LED signal * The firmware type loaded into the communication hub controls what interface is enabled. EAC addressing features (RS-485) This applies for AH15 and AH30 communication hubs. Addressing alternatives The communication hubs can use up to 63 addresses depending on usage: Address 1-15: Applicable for all types of installations where one or several locks are paired to the communication hub. (one-toseveral installation). Addresses is selected by the DIP-switch or the Aperio Programming Application. Address 16-31: For communication hubs with only one lock paired. Address is selected by DIP-switch or the Programming Application. Address 32-63: For communication hubs with only one lock paired (single device mode). Address can only be selected using the Programming Application. For details, refer to the Aperio Programming application Manual, ref [2]. Different EAC addressing modes Communication hubs can be set to address the locks in two different ways, normal and legacy mode. Legacy address offset is used when the EAC has a low limit for handling addresses. Normal address offset mode is used when the EAC can handle addresses without limit. Aperio Online System Description, Document No: ST-002326-B Date: 4 August 2015 9

Remote Unlock use cases Aperio support three options for setting a door unlocked. Office Mode/First Man In Scheduled relock Remote unlock The time the unlock command is valid can furthermore be configured in the communication hub through the Time to livesetting when using the Remote Unlock function. During these use cases there is a possibility to disable sensor events from the lock. This will conserve battery life and also keep the traffic down when used in high traffic doors. Office Mode/First Man In The EAC manages which users have right to set a door unlocked. Example: The lock is set unlocked by the first card holder that enters the office in the morning. Scheduled relock This mode is suitable when longer unlock periods are used and ensures that the lock is locked at a certain time. The unlock command from the EAC is sent to the communication hub. First when the Aperio lock performs a status update or a user presents a credential at the lock the unlock command is sent to the lock. The waiting time in the communication hub is deducted from the total remote unlock time to ensure that the relock occurs at the correct time. Example: The EAC sends an unlock command of to a communication hub to unlock a certain lock for 3 hours (between 5 pm and 8 pm). The command waits in the communication hub for 30 minutes until the lock connects. The waiting time is in this case deducted and the lock will be relocked after 2.5 hours (8 pm). Example: The EAC sends an unlock command of 10 minutes to a communication hub valid for a certain lock. The waiting time in the communication hub is 5 minutes until lock connects and gets the unlock command. The total unlock time will in this case still be 10 minutes. Remote unlock configuration The time period the unlock command stays active in the communication hub can be set. This is the Time to live-setting. It is important to synchronize this setting with the Status report interval setting in the lock. The Time to live-setting must be shorter than the status report interval time to ensure that EAC commands are sent to the lock. Audit trails The audit trail log in the lock units keeps track of the access attempts made on each particular door when the lock is offline from the communication hub and/or EAC. There are 200 entries in the log which means that it will be full after 200 access attempts. When a card is presented and the log is full, the oldest entry will be replaced with the result from the new access attempt. Each entry consists: Time stamp Credential UID/Data/PIN Access decision, granted/denied. The audit trail log can be read out with the Aperio Programming Application. Remote unlock This function is similar to the Schedule relock function with the difference that the unlock time period is left unchanged. This mode is suitable for shorter unlock periods of for example a few minutes. 10 Aperio Online System Description, Document No: ST-002326-PD Date: 4 August 2015

ASSA Aperio ABLOY Online is the global leader in door opening solutions, dedicated to satisfying end-user needs for security, safety and convenience Contact www.assaabloy.com/aperio 12 Wireless lock technology