Technical Service Bulletin October 2013 TSB 134.03



Similar documents
SET-UP AND INSTALLATION FOR LEAD SCREW CARTRIDGE ASSEMBLY

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Stainless Steel Single and Dual Circulation Kits

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

CPL SYSTEMS / GROENEVELD AUTOMATIC GREASING SYSTEM COMPLETE SYSTEM CHECK PNEUMATIC PUMP

Installation Instructions S

FILLING AND PURGING THE SYSTEM

Submersion/Insertion Toroidal Sensor

Procenter Delivery System* Troubleshooting Charts

Installation and Maintenance Instructions

15CI and 25CI Reversing Motor Pumpset Owner's Manual

Installation Instructions

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Overview PARTS LIST. B. Lever mounting base C. Flush handle assembly D. Grey/Blue float stop E. Grey float (Full Flush) F. Flush valve washer

STEERING SYSTEM - POWER

NUMBER: 08 DD15-10 S.M. REF.: 3.2 ENGINE: DD15 DATE: September 2008

Float and Thermostatic Traps Series H, C and X

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

STORAGE, INSTALLATION AND MAINTENANCE PROCEDURES

Installing a Probe. Typical Installation

MANDATORY SERVICE BULLETIN

2006 HEADSHOK Service Video #1

R-134A A/C SYSTEM REFRIGERANT DYE LEAK DETECTION

Water Tec of Tucson Water Systems

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

Easy Tool Retracting System CMC-SR2159ER36

REPAIR AND MAINTENANCE MANUAL

VAG 1687 Diagnostic Tool, Checking Intake System for Leaks. Condition. Service 00-A A353

SureSite Magnetic Liquid Level Indicator

Round Housing with Side Ports

Range Road RR Series Semi-Automatic Firewood Processor. Crated Unit Assembly Manual

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Technical Data. Installation

Installation Instructions

Fire Hydrant Troubleshooting

TECHNICAL DATA. Dry 122a. November 12, 2013

MODEL G300 BRAKE BLEEDER

Fiberstars Mini Lighted Laminar Flow Fountains

Submersion/Insertion Toroidal Sensor

Fisher 249 Caged Displacer Sensors

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Pro-OX 7800 Iron Filter Installation & Start-Up Guide

SALEEN SPEEDLAB SERIES VI STANDARD SC UPGRADE KIT

FLUSHOMETER - TANK SYSTEM

149mm. Walk-Thru Assembly Gate. MODEL NO: 1161, 1167 Owner s Manual.

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

INSTRUCTIONS. FLHR/C/S (Road King) FRONT END LOWERING KIT 1WARNING -J03242 REV General. Removal (Left and Right Forks) Kit Number

Fuel Injection Pump, Rotary ( )

Standard Hydraulic Piping Flushing Procedure

2:1 RATIO TRANSFER PUMP

CLEAN AND CLEAR PLUS CARTRIDGE FILTER

Joplin Rebuild Instructions

MP-4V Heavy Duty Riveter / 39048

Model 43AP Pneumatic Controller, Style B

758 Heavy-duty Ratchet Guy Wire Cutter

CYLINDER LEAKAGE CHECK (Compression)

Volkswagen Golf > VW Rabbit GTI 2006->

Iron Air Charge 2510-SXT Installation & Start-Up Guide

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

Slide the new steering column shaft through the steering column from the driver compartment.

L /96. Haldex INSTALLATION INSTRUCTIONS HALDEX PURE AIR PLUS EXTENDED PURGE KIT (DQ6027) HEAVY DUTY CANISTER KIT (DQ6028)

SE-100-1, SE-200-1, SE-500-1, and SE AIR CHAMP PRODUCTS. User Manual SE BRAKE MODELS: (i) MTY (81)

Number Wheeler P/N Description Set Rex P/N Notes Base 1 J Support, Right 1 J Support, Left 1 J Nut (M8)

Flushing and Cleaning the A/C System

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

ENGINE FUEL FUEL FILTER... FUEL HEATER... INJECTOR... SUPPLY PUMP... COMMON RAIL... FUEL PRESSURE LIMITTER...

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

TRAINING AND EQUIPMENT MANUAL HOSE PRACTICES EFFECTIVE: OCTOBER 2007

RC HELICOPTER INSTRUCTION MANUAL

300 SERIES 331, 332, 333, 344, 356 AND 367 MODELS

Allspeeds Ltd. Royal Works, Atlas St Clayton le Moors Accrington Lancashire England BB5 5LW. Tel +44 (0)

Replacement Instructions ABI 431A/433A Waste Port

TRAINING BULLETIN Fire Apparatus Pump Test

Technical Guide 08/15/14

COOLING SYSTEM Section Page

RAPID RESPONSE Model RSV-1 Residential Shut-Off Valve, 1 Inch and 2 Inch (DN25 and DN50) for Dual-Purpose Residential Water Supply General Description

Mazda North American Operations Irvine, CA MX-5 - WATER ACCUMULATION IN FOOTWELL / PLUGGED SOFT TOP DRAINS BULLETIN NOTE

How To Replace A Reverse Osmosis Water Tank

OWNER'S MANUAL FOR MODEL "SM 12"

Hot, Warm and Cold Mineral Water Cooler [Models Cool18, Cool25, Cool36, Cool50, Cool75, Cool100]

Cooling system components, removing and installing

UNIT 7: PLUMBING KEY CONCEPTS. 1. Identify tools for plumbing. 2. Location of shutoff valves for the main and individual fixtures

AIR LINE VALVES AND GAUGES

Dive Rite 200 & 300 Bar Isolator Manifold Service Manual

Combustible Gas Transmitter RK-05

Meritor WABCO Hydraulic Power Brake (HPB) System Bleeding Procedures

3", 4", 6" & 8" Model H Series Alarm Check Valve Installation and Maintenance Guide

- power windows - alarm system - electric door mirror control - door warning light - central locking - seat memory

HT3 series Peck Feed Drills, with Equal Drill Time

LK Wallbox UNI Push. Assembly. Only intended for LK PE-X Universal Pipe X.

with installation dynafact boost GAUGE this manual is for use with systems

Cryogenic Vacuum Pumps

Installation, Maintenance, & Repair Series 4000B/LF4000B

INSTRUCTIONS AND PARTS LIST FOR MODEL 70H & 75H HAND-OPERATED HYDRAULIC PRESS

OP300S / OP350 2:1 RATIO TRANSFER PUMP

Installation Manual. Solar Pool Heating System. Read the complete manual before beginning the installation

Transcription:

Technical Service Bulletin October 2013 TSB 134.03 Bubble Testing and Fiber Repair. This Technical Service Bulletin provides information for locating compromised fibers within a HYDRAcap module, their isolation and repair. General Bubble Testing Once a module has been determined to have a leak, from integrity testing (see TSB133), the module must be removed from the HYDRABLOC or rack to be bubble tested. Bubble testing is used to determine location of the leak(s). When the module is properly fitted with Hydranautics bubble test apparatus (see Drawing M51181-G), it then becomes a matter of watching for bubble formation from the leak source. Continuous large bubble formation will be indicative of a compromised fiber. The following will be required to perform a bubble test: Hydranautics bubble test apparatus. Table, saw horses or other support structure. Air hose with ¼ (NPT) male pipe thread. Pressurized air (oil free) and pressure regulator set to 15 psi (1 bar). Tools for removing HYDRAcap module end caps (see TSB136). A water source to fill bubble test apparatus. A flashlight is useful for viewing the fiber ends and locating specific leaks. 1. Drain water from HYDRABLOC or rack. Remove suspect module(s) and seal manifold piping connections with caps (not supplied). 2. Disassemble module (see TSB136). 3. The module should be supported horizontally at least three feet above ground for effective usage of the apparatus. 4. Attach tension rod (PN: 11620.1000 for 40 module or 11620.0000 for 60 module) to product plug adapter (PN: 11611.1000). 5. Insert rod through the module core tube such that O-rings of the product plug adapter engage into the core tube. 6. Attach bubble test apparatus endcap encasements (PN: 11570.0000) to both module ends. Ensure that the Tygon tubing seals (PN: 11580.2000) are engaged. 7. Tighten clamping knobs (PN: 11623.0000) to secure endcap encasements. 8. Fill endcap encasements with water. Ensure that water fills the core tube and filtrate area of the module.

TSB 134.03 Page 2 9. Connect product end adapter (PN: 11568.1000) to other end of tension rod. The O-rings of the product end adapter must engage into the core tube after tightening is completed (see figure 1.). NOTE: All fibers should be completely immersed in water. Be aware that upon pressurization, this water will be pushed thru the fibers and will overflow the test apparatus. 10. Connect air source with female quick connection (provided with apparatus). 11. Slowly introduce pressurized air into the module. At this point, water should overflow the encasements. After all the water from the filtrate has been displaced by air, leaking fibers will then be evident by the presence of streaming bubbles. 12. Observe bubble formation on both sides of the module. Compromised fibers will show large continuous bubble formation. If the fiber damage is severe, extremely vigorous bubbling will obscure vision. If this occurs, reduce the pressure and proceed. NOTE: Small bubbles are common and a result of air diffusion through membrane pores. Diffusion rates are proportional to air pressure so initial bubble testing at lower pressure (i.e., 5 psi) may be beneficial. 13. If a compromised fiber is located, it must be marked by plugging it with a fiber repair pin (PN: 11612.0000). 14. Once all suspected leaking fibers have been marked, shut off air supply and bleed air from the module. 15. Loosen clamping knobs and disengage O-ring on endcap encasements such that the water is drained from the module. 16. Remove endcap encasements from the module. Fiber Repair To restore integrity ( membrane barrier ) of the module, all leaking fibers should be isolated or rendered inactive by permanently plugging them with Hydranautics repair pins. The polysulfone pins are permanently bonded to the inside fiber wall by first applying Loctite 4061 adhesive to the pins and then pressing them into the leaking fiber. The following items are required for fiber repair: Hydranautics repair pins (PN: 11612.0000) 6 pins per assembly Loctite cyanoacrylate 4061 adhesive. Utility knife or razor blade. 1. At this point the module should be depressurized, drained of all water and the marker repair pins should be inside suspect fibers. Apply the Loctite adhesive to a new pin, immediately remove a marker pin, and replace it with the new pin. Repeat as necessary. 2. The bonding of the pins should take no more than one minute. Carefully remove any residual length of pin with a utility knife or blade. 3. Repeat bubble test, with special care to check at low pressure 0.5psi and slowly up to 15psi to verify no leaks are present. 4. Reassemble module (see TSB136). 5. When all modules are completed, verify Integrity by performing an integrity test (see TSB133).

TSB 134.03 Page 3 Encasement end view Bubble test apparatus during bubble testing.

TSB 134.03 Page 4

Hydranautics 401 Jones Rd. Oceanside, CA 92058 Tel: (760) 901-2500 Fax: (760) 901-2578 email: info@hydranautics.com TSB 134.03 Page 5