ISOLATE II PCR and Gel Kit. Product Manual

Similar documents
PCR and Sequencing Reaction Clean-Up Kit (Magnetic Bead System) 50 preps Product #60200

TIANquick Mini Purification Kit

Plant Genomic DNA Extraction using CTAB

UltraClean PCR Clean-Up Kit

Wizard SV Gel and PCR Clean-Up System

UltraClean Soil DNA Isolation Kit

NimbleGen DNA Methylation Microarrays and Services

Genomic DNA Extraction Kit INSTRUCTION MANUAL

50 g 650 L. *Average yields will vary depending upon a number of factors including type of phage, growth conditions used and developmental stage.

Genomic DNA Clean & Concentrator Catalog Nos. D4010 & D4011

PCR clean-up Gel extraction

MinElute Handbook. Sample & Assay Technologies. March 2008

GRS Plasmid Purification Kit Transfection Grade GK (2 MaxiPreps)

The fastest spin-column based procedure for purifying up to 10 mg of ultra-pure endotoxin-free transfection-grade plasmid DNA.

Troubleshooting Guide for DNA Electrophoresis

AxyPrep TM Mag PCR Clean-up Protocol

ELUTION OF DNA FROM AGAROSE GELS

Wizard DNA Clean-Up System INSTRUCTIONS FOR USE OF PRODUCT A7280.

Application Guide... 2

FOR REFERENCE PURPOSES

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

Procedure for RNA isolation from human muscle or fat

UltraClean Forensic DNA Isolation Kit (Single Prep Format)

An In-Gel Digestion Protocol

Troubleshooting Sequencing Data

ExpressArt Bacterial H-TR cdna synthesis kit. With extreme selectivity against rrnas

First Strand cdna Synthesis

ab Hi-Fi cdna Synthesis Kit

PowerFecal DNA Isolation Kit

MICB ABI PRISM 310 SEQUENCING GUIDE SEQUENCING OF PLASMID DNA

HiPer RT-PCR Teaching Kit

Classic Immunoprecipitation

QIAGEN Supplementary Protocol

Southern Blot Analysis (from Baker lab, university of Florida)

Genomic DNA clean-up

DNA Isolation Kit for Cells and Tissues

PicoMaxx High Fidelity PCR System

Detailed protocol: Combined method for RNA isolation. from cartilage

TECHNICAL BULLETIN. HIS-Select Nickel Affinity Gel. Catalog Number P6611 Storage Temperature 2 8 C

Kevin Bogart and Justen Andrews. Extraction of Total RNA from Drosophila. CGB Technical Report doi: /cgbtr

Amplicon Template Preparation and Sequencing

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

HighPure Maxi Plasmid Kit

RevertAid Premium First Strand cdna Synthesis Kit

MagExtractor -Genome-

LAB 11 PLASMID DNA MINIPREP

Contents. XI. Materials and Equipment Needed But Not Provided 5. DNA Extraction from Small Amount of Tissue 10

Electrophoresis, cleaning up on spin-columns, labeling of PCR products and preparation extended products for sequencing

Maxwell 16 Blood DNA Purification System

ZR DNA Sequencing Clean-up Kit

HiPer Ion Exchange Chromatography Teaching Kit

Whole genome Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

Reduced Representation Bisulfite Sequencing for Methylation Analysis Preparing Samples for the Illumina Sequencing Platform

HiPer Total RNA Extraction Teaching Kit

CompleteⅡ 1st strand cdna Synthesis Kit

BacReady TM Multiplex PCR System

STA DARD OPERATI G PROCEDURE FOR THE DETECTIO OF AFRICA SWI E FEVER VIRUS (ASFV) BY CO VE TIO AL POLYMERASE CHAI REACTIO (PCR)

How To Get Rid Of Small Dna Fragments

U.S. Patent No. 9,051,563 and other pending patents. Ver

ZR-96 DNA Sequencing Clean-up Kit Catalog Nos. D4052 & D4053

Aurora Forensic Sample Clean-up Protocol

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Genolution Pharmaceuticals, Inc. Life Science and Molecular Diagnostic Products

MLX BCG Buccal Cell Genomic DNA Extraction Kit. Performance Characteristics

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

All-in-One First-Strand cdna Synthesis Kit

SOLIDscript Solid Phase cdna Synthesis Kit Instruction Manual

Technical Manual No Update Date

ab Protein Sumoylation Assay Ultra Kit

Protocol v001 Page 1 of 1 AGENCOURT RNACLEAN XP IN VITRO PRODUCED RNA AND CDNA PURIFICATION

RESTRICTION ENZYME ANALYSIS OF DNA

Preparing Samples for Sequencing Genomic DNA

Blood Collection and Processing SOP

Lab 10: Bacterial Transformation, part 2, DNA plasmid preps, Determining DNA Concentration and Purity

Olympic B3 Summer Science Camp 2015 Weller, Smith, Putnam L3

How To Use An Enzymatics Spark Dna Sample Prep Kit For Ion Torrent

Chromatin Immunoprecipitation (ChIP)

ABSTRACT. Promega Corporation, Updated September Campbell-Staton, S.

TransformAid Bacterial Transformation Kit

Sequencing Guidelines Adapted from ABI BigDye Terminator v3.1 Cycle Sequencing Kit and Roswell Park Cancer Institute Core Laboratory website

EZ Load Molecular Rulers. Catalog Numbers bp bp bp PCR bp kb Precision Mass

Sanger Sequencing: Sample Preparation Guide

RiboZol RNA Extraction Reagents

Objectives: Vocabulary:

The Techniques of Molecular Biology: Forensic DNA Fingerprinting

All-in-One mirna qrt-pcr Reagent Kits For quantitative detection of mature mirna

AxyPrep Blood Genomic DNA Maxiprep Kit

Terra PCR Direct Polymerase Mix User Manual

DNA SPOOLING 1 ISOLATION OF DNA FROM ONION

How To Shear Chromatin

Running protein gels and detection of proteins

GenScript BloodReady TM Multiplex PCR System

DNA: A Person s Ultimate Fingerprint

RT-PCR: Two-Step Protocol

Arcturus PicoPure RNA Isolation Kit. User Guide

DNA SEQUENCING (using an ABI automated sequencer)

Section XIII: Protein Separation in Agarose Gels

Sequencing Library qpcr Quantification Guide

Transformation Protocol

Transcription:

ISOLATE II PCR and Gel Kit Product Manual

2 Product Manual www.bioline.com/isolate

PCR and Gel Kit ISOLATE II PCR and Gel Kit ISOLATE II PCR and Gel Kit 1 Kit contents 04 2 Description 04 3 Storage 04 4 Safety information 04 5 Product specifications 05 6 Equipment and reagents to be supplied by the user 07 7 Important notes 07 7.1 Removal of small DNA fragments and primerdimers 7.2 ph indicator 07 7.3 Factors affecting DNA recovery 08 7.4 Salt carry-over 08 7.5 Buffer preparation and parameters 08 8 Protocols 09 8.1 PCR clean-up 09 8.2 DNA extraction from agarose gels 10 8.3 DNA extraction from polyacrylamide gels 10 9 Troubleshooting guide 11 General Information A. Technical support 14 B. Ordering information 14 C. Associated products 14 D. Product warranty and disclaimer 14 07 3

1. Kit contents component 10 preps 50 preps 250 preps ISOLATE II PCR and Gel Columns (yellow) 10 50 250 Collection Tubes (2ml) 10 50 250 Binding Buffer CB 10ml 2 x 25ml 2 x 120ml Wash Buffer CW (concentrate) 6ml 20ml 2 x 50ml Elution Buffer C 5ml 15ml 50ml Product Manual 1 1 1 Bench Protocol Sheet 1 1 1 Before use, add indicated volume of 96-100% ethanol and mark wash buffer bottle label. 2. Description The ISOLATE II PCR and Gel Kit is a simple, reliable and fast method for the isolation of high-quality DNA fragments from enzymatic reactions, such as PCR, as well as from agarose gels. It uses a binding buffer and collection tube for silica-membrane-based binding of DNA fragments, in the presence of chaotropic salt. Contaminants are removed by simple washing steps and pure DNA is eluted under low salt conditions. The isolated DNA is suitable for use with all downstream molecular biology applications. Please read this manual carefully to familiarise yourself with the ISOLATE II PCR and Gel protocol before starting (also available on www.bioline.com). More experienced users can refer to the bench-top protocol for quick referencing during the procedure. 3. Storage All kit components should be stored at room temperature (18 25 C) and are stable for up to 1 year. 4. Safety information When working with chemicals, always wear a suitable lab coat, gloves and safety glasses. Binding Buffer CB contains chaotropic salt. For detailed information, please consult the material data safety sheets (MSDSs) available on our website at www.bioline.com. 4 Product Manual www.bioline.com/isolate

PCR and Gel Kit 5. Product specifications The ISOLATE II PCR and Gel Kit is specially designed for the rapid and efficient isolation of extremely pure DNA from enzymatic reactions, as well as TAE or TBE agarose gels. The kit offers very high DNA binding capacity of up to 25µg and ensures complete removal of contaminants such as nucleotides, primers, enzymes, mineral oil, PCR additives (e.g. salts, betaine, DMSO), commonly used detergents (Tween 20 or Triton X-100), dyes (e.g. ethidium bromide, crystal violet) and unbound labels or tags. ISOLATE II PCR and Gel Kit Specifications Binding capacity Sample material Optimal recovery Elution volume Fragment length 25μg Up to 200μl of PCR product or 200mg of gel <15μg 100 500bp 30μl 15-30μl 50bp to 20kb PCR primers from reactions are eliminated while small DNA fragments are still bound and purified with high recovery. The cut-off for small DNA fragments can be shifted from <50bp to several hundred base pairs by diluting Binding Buffer CB to remove primer-dimers from target PCR products. A yellow ph indicator in Binding Buffer CB ensures optimal binding conditions and makes it easier to identify undissolved agarose during DNA gel extraction. The preparation time is 10 min for 6 PCR purifications, or 20 min for 6 gel extractions. The purified DNA is suitable for applications such as hybridization, sequencing, PCR, restriction, digestion, ligation, in vitro transcription, labeling or many kinds of enzymatic reactions. 5

PCR and Gel Clean-up PCR clean-up Add 200µl Binding Buffer CB per 100µl of PCR product Mix Gel extraction Excise DNA fragment Gel solubilization Add 200µl Binding Buffer CB per 100mg gel Incubate 50 o C, 5-10 min and vortex Bind DNA Load sample 11,000 x g, 30s Wash silica membrane 1 st wash 700µl Wash Buffer CW 2 nd wash 700µl Wash Buffer CW (recommended) 1 st and 2 nd 11,000 x g, 30s Dry silica membrane 11,000 x g, 1 min Elute DNA Add 15-30µl Elution Buffer C Incubate RT, 1 min 11,000 x g, 1 min Isolated DNA 6 Product Manual www.bioline.com/isolate

PCR and Gel Kit 6. Equipment and reagents to be supplied by the user When working with chemicals, always wear a suitable lab coat, protective goggles and disposable gloves. 96-100% ethanol Microcentrifuge tubes (1.5ml) Sterile DNase-free tips Pipettes Microcentrifuge (capable of 11,000 x g) Vortex mixer Thermal heating block Scalpel to cut agarose gels Diffusion buffer (500mM ammonium acetate, ph 8.0, 0.1% SDS, 1mM EDTA, 10mM magnesium acetate) if extracting DNA from polyacrylamide gels Molecular biology grade ethanol is recommended. Do not use denatured alcohol which contains unwanted additives such as methanol and acetone. 7. Important Notes 7.1 Removal of small DNA fragments and primer-dimers Removal of double stranded DNA >50bp can be achieved by diluting an aliquot of Binding Buffer CB with sterile water in an appropriate ratio and then proceeding with the standard PCR clean-up protocol. Diluting Binding Buffer CB lowers the binding efficiency for small fragments without compromising the recovery of larger PCR products; however, the dilution ratio will depend on the fragment size as well as detergents and additives. In general, if a PCR buffer system without special additives is used, adding 3 to 5 volumes of water to 1 volume of Binding Buffer CB will lead to removal of small fragments up to 100bp, otherwise adding 1 to 3 volumes of water to 1 volume of Binding Buffer CB will be sufficient. 7.2. ph indicator The Binding Buffer CB is sufficiently buffered to maintain an optimal ph of 5.0 6.0. It will even bind small DNA fragments to the silica membrane of the ISOLATE II PCR and Gel Columns, for all standard PCR reaction buffers or agarose gel buffer systems. In addition, the colored binding buffer helps identify undissolved agarose during DNA gel extraction. A yellow color indicates the optimal ph <6.0. If the ph increases to about 7.0 after adding the sample, the solution will turn green and above 7.0 the solution turns blue. If a change in color is observed, the ph should be corrected by adding more Binding Buffer CB or by titrating the ph back to <6.0 with 4M sodium acetate (ph 5.0) or small amounts of hydrochloric acid (HCl). 7

7.3 Factors affecting DNA recovery DNA fragment size Upon completion of the wash steps with Wash Buffer CW, the DNA will adhere to the silica membrane. The standard elution buffer volume is 15 30μl which is best for high DNA recovery and high DNA concentration for fragments <1000 bp. Large DNA fragments bind much more tightly and are much more difficult to elute than small DNA fragments. The ISOLATE II PCR and Gel Kit is recommended for DNA up to 10 15kb. Longer fragments can be purified but recovery may be low and above 20kb they may be damaged by centrifugation (mechanical shearing through the membrane). Agarose gel extraction Although TBE agarose gels can be used with the ISOLATE II PCR and Gel Kit, TAE is preferred as it gives better resolution (especially when run at a lower voltage and only long enough to separate the band of interest) and does not interact with the agarose, resulting in higher DNA yields. When extracting the gel slice, exposure to UV light should be minimized and only up to 200mg of gel per 400μl of Binding Buffer CB used. Virtually unlimited amounts of gel can however, be loaded without clogging the column, by increasing Binding Buffer CB proportionally and using multiple loading steps. If higher DNA concentrations are required, elute in less than 30μl (although concentration can be more than doubled, total DNA recovery will be significantly reduced for volumes less than 15μl). 7.4 Salt carry-over Salt carry-over into the eluate always happens with chaotropic salt. Although this can only be minimized by extensive washing, this is unnecessary, since the final concentration of chaotropic salt in eluates is far too small to have any negative effect. 7.5 Buffer preparation and parameters Preparing Wash Buffer CW Add 96 100% ethanol (not supplied) to Wash Buffer CW Concentrate: 24ml for the 10 prep kit, 80ml for the 50 prep kit and 200ml x 2 for the 250 prep kit. Elution buffer We highly recommended eluting DNA with Elution Buffer C (ph 8.5), which is provided with 8 Product Manual www.bioline.com/isolate

PCR and Gel Kit the kit. A standard TE buffer may also be used, however the EDTA in the buffer may cause problems in subsequent enzymatic reactions. Do not use deionized water since its ph is usually too acidic, instead dilute Elution Buffer C with distilled water and make sure the ph is still >7.0. Unbuffered elution buffer should not be used. Elution after gel extraction is 10 20% less efficient than elution of purified PCR products. In addition, elution of several kb long DNA fragments is 10 30% less efficient than elution of 500bp fragments. To improve the DNA recovery after gel extraction, or for large DNA fragments, the following modifications can be applied to the standard elution procedure: Heat Elution Buffer C to 70 C and incubate on the column at 70 C for 5 min. Apply Elution Buffer C to the column and centrifuge at 30 50 x g for 1 min and then at 11,000 x g for 1 min. Perform up to 3 elution steps with 20 or 30μl fresh Elution Buffer C. 8. Protocols 8.1 PCR clean-up Suitable for PCR clean-up, DNA concentration and removal of salts, primers, enzymes, detergents, dyes, additives and other contaminants (see section 5). Before you start: Make sure Wash Buffer CW is prepared (see section 7.5). 1 Sample preparation For volumes <30μl, adjust the volume to 50 100μl with water (removal of mineral oil is unnecessary). Mix 1 volume of sample with 2 volumes of Binding Buffer CB. Note: For removal of small fragments like primer-dimers, dilutions of Binding Buffer CB can be used instead of 100% Binding Buffer CB. See section 7.1. 2 Bind DNA For each preparation, place one ISOLATE II PCR and Gel Column in a Collection Tube (2ml) and load sample. Centrifuge for 30s at 11,000 x g and discard flow-through. Reuse the Collection Tube for step 3. 3 Wash silica membrane Add 700μl Wash Buffer CW to the ISOLATE II PCR and Gel Column and centrifuge for 30s at 11,000 x g. Discard the flow-through and place the column back into the collection tube. Recommended: Repeat washing step to minimize chaotropic salt carry-over. 9

4 Dry silica membrane Centrifuge for 1 min at 11,000 x g, to remove residual ethanol. Place the ISOLATE II PCR and Gel Column in a 1.5ml microcentrifuge tube (not supplied). Note: Residual ethanol might inhibit enzymatic reactions. Total removal of ethanol can be achieved by incubating the columns at 70 C for 2 5 min prior to elution. 5 Elute DNA Add 15-30μl Elution Buffer C directly onto the silica membrane. Incubate at room temperature for 1 min. Centrifuge 1 min at 11,000 x g. Note: For alternative elution procedures see section 7.3. 8.2 DNA extraction from agarose gels Before you start: Make sure Wash Buffer CW is prepared (see section 7.5). 1 Excise and dissolve gel slice Using a clean scalpel excise the DNA fragment from the gel. Remove excess agarose, determine the weight of the slice and transfer into a clean tube. Add 200μl Binding Buffer CB per 100mg of 2% agarose gel*. * For gels containing >2% agarose, double the volume of Binding Buffer CB. Incubate sample at 50 C for 5 10 min, vortexing the sample briefly every 2 3 min until the gel slice is completely dissolved. 2 Bind DNA Proceed with step 2 of the PCR clean-up protocol (see section 8.1). 8.3 DNA extraction from polyacrylamide gels Polyacrylamide gels cannot be dissolved like agarose gels to extract the trapped DNA, instead the gel is crushed and soaked in a Diffusion buffer (not supplied). Before you start: Make sure Diffusion buffer is prepared (see section 6). 1 Preparation of gel Using a clean scalpel excise the DNA fragment from the gel. Remove as much excess polyacrylamide as possible and transfer into a clean 1.5ml microcentrifuge tube (not supplied). Crush the gel slice using a heat sealed disposable pipette tip to act as a pestle. The smaller the pieces, the better the DNA recovery. 10 Product Manual www.bioline.com/isolate

PCR and Gel Kit 2 Extract DNA Add 200μl of Diffusion Buffer to each 100mg of crushed gel. Ensure all gel pieces are submerged and incubate for 30 60 min at 50 C or overnight at 37 C. 3 Remove polyacrylamide Transfer to an ISOLATE II PCR and Gel Column and centrifuge for 1 min at 11,000 x g. Keep flow-through containing the DNA. Optional: Steps 2 and 3 can be repeated to increase yield. 4 Sample preparation Mix 1 volume of sample with 2 volumes of Binding Buffer CB. Note: For removal of small fragments like primer-dimers dilutions of Binding Buffer CB can be used instead of 100% Binding Buffer CB. See section 7.1. Small amounts of precipitated SDS does not affect the purification and can be ignored. 5 Bind DNA Proceed with step 2 of the PCR clean-up protocol (see section 8.1). 11

9. troubleshooting GUIDE Incompletely dissolved gel slice Possible cause Insufficient time and temperature Recommended solution Check incubation temperature and volume of Binding Buffer CB. Increase incubation time, vortex every 2 min and check the integrity of the gel slice. Very large gel slices can be crushed before addition of Binding Buffer CB to shorten the melting time. Appearance of additional bands on agarose gel after gel extraction Possible cause DNA denatured during purification Recommended solution If water is used for elution or agarose with low ion content is used for agarose gel electrophoresis, the formation of denaturated (single-stranded) DNA might be promoted. To reanneal the DNA, simply add all components of the subsequent enzymatic reaction omitting the enzyme. Incubate at 95 C for 2 min and let the mixture cool slowly to room temperature. Add the enzyme and continue with downstream application. Use fresh running buffer and run at low voltage to lower the temperature. High temperatures can promote DNA denaturation during electrophoresis. Low DNA yield Possible cause Incompletely dissolved gel slice Insufficiently dried silica membrane Incomplete elution Reagents not prepared properly Recommended solution Increase time or add another two volumes of Binding Buffer CB and vortex the tube every 2 min during incubation at 50 C. Centrifuge 5 min at 11,000 x g or incubate column for 2 5 min at 70 C before elution to remove ethanol completely. Remove the spin column carefully from the Collection Tube and avoid contact of spin column with flow-through. Particularly for larger DNA amounts (>5µg), long DNA fragments (>1kb), or after gel extraction, perform multiple elution steps with fresh buffer, heat to 70 C and incubate for 5 min, (See section 7.3). Ensure Wash Buffer CW Concentrate is prepared with the correct volume of 96-100% ethanol and mix well before use (see section 7.5). 12 Product Manual www.bioline.com/isolate

PCR and Gel Kit Suboptimal performance of DNA in Spectrophotometer or Bioanalyzer Possible cause Carry-over of residual silica particles Recommended solution Spectrophotometers (e.g. NanoDrop ) are particularly sensitive to any particles included in the sample material. To pellet the silica particles, centrifuge > 2 min at 11,000 x g and keep supernatant for further use. Suboptimal performance of DNA in sequencing, restriction, or ligation reactions Possible cause Recommended solution DNA damaged by UV light Reduce UV exposure time when excising a DNA fragment from an agarose gel. Carry-over of ethanol Before elution, centrifuge 5 min at 11,000 x g or incubate column for 5 10 min at 70 C to remove ethanol completely. Ethanol contamination is also indicated by gel loading problems (samples float out of gel slots). Remove the spin column carefully from the Collection Tube and avoid contact of the spin column with the flow-through. Use either a different brand of ethanol to reconstitute Wash Buffer CW or ethanol that is not denatured. The denaturing components may not evaporate as fast as ethanol and end up concentrated in the eluate, inhibiting enzymes like ligase. Carry-over of chaotropic salts Perform the optional washing step. Alternatively more Wash Buffer CW can be loaded before the drying step. (Note: This will reduce the number of preparations that you can do with the kit). Elution of DNA with buffers other than Buffer C e.g. TE buffer (Tris/ EDTA) Insufficient DNA template used for sequencing reaction EDTA might inhibit sequencing reactions. In this case it is recommended to re-purify DNA and elute in Elution Buffer C. Quantify DNA by agarose gel electrophoresis before setting up sequencing reactions. 13

A. Technical SUPPORT For technical assistance or more information on these products, please email us at tech@bioline.com b. ORDERING INFORMATION Product Pack Size Cat No. ISOLATE II PCR and Gel Kit 10 Preps BIO-52058 ISOLATE II PCR and Gel Kit 50 Preps BIO-52059 ISOLATE II PCR and Gel Kit 250 Preps BIO-52060 c. ASSOCIATED PRODUCTS Product Pack Size Cat No. Agarose 100g BIO-41026 MyTaq TM HS DNA Polymerase 250 Units BIO-21111 HyperLadder TM I 500 Lanes BIO-33026 HyperLadder TM IV 500 Lanes BIO-33030 d. Product Warranty and Disclaimer Bioline warrants that its products will conform to the standards stated in its product specification sheets in effect at the time of shipment. Bioline will replace free of charge any product that does not conform to the specifications. This warranty limits Bioline s liability only to the replacement of the product. 14 Product Manual www.bioline.com/isolate

www.bioline.com United Kingdom Bioline Reagents Ltd 16 The Edge Business Centre Humber Road London NW2 6EW Tel: +44 (0)20 8830 5300 Fax: +44 (0)20 8452 2822 email: info.uk@bioline.com Germany Bioline GmbH Im Biotechnologiepark, TGZ 2 D-14943 Luckenwalde Tel: +49 (0)3371 68 12 29 Fax: +49 (0)3371 68 12 44 email: info.de@bioline.com Australia Bioline (Aust) Pty Ltd PO Box 122 Alexandria NSW 1435 Tel: +61 (0)2 9209 4180 Fax: +61 (0)2 9209 4763 email: info.aust@bioline.com USA Bioline USA Inc. 305 Constitution Drive Taunton MA 02780 Tel: +1 508 880 8990 Fax: +1 508 880 8993 Order Toll Free: +1 888 257 5155 email: info.us@bioline.com PM0812V1.0