SBR FIRE RISK ASSESSMENT



Similar documents
Fire Safety Risk Assessment

FIRE SAFETY RISK ASSESSMENT

Grasshoppers Rugby Football Sports and Social Club. The Fire Risk Assessment

1.1. EMERGENCY PROCEDURE On discovering a fire or being informed of an emergency;

FIRE RISK ASSESSMENT

Fire Policy and Procedures. Cañada Blanch Spanish School

Fire Evacuation Procedures Network Building, 97 Tottenham Court Road, London, W1

Fire Risk Assessment Safety Checklist

CITY OF LONDON SCHOOL FOR GIRLS FIRE SAFETY, PROCEDURE AND RISK ASSESSMENT POLICY

Action required (Please tick) If you answered YES, record Action Points at STEP 4

Fire Risk Assessment For Simple Premises

How To Write A Fire Risk Assessment

Fire Safety Risk Assessment Checklist for Residential Care Premises

Fire Safety Challenges and Solutions. Claire Guise Health and Safety Manager

Bastille Court 2 Paris Garden London SE1 8ND Telephone: Fax: training@thefpa.co.uk Web:

Healthcare Help Supporting Health Providers. Module 2 Resources for Fire Warden Refresher Training HH.NET LTD

RESIDENTS FIRE SAFETY INFORMATION PACK

RESIDENTS FIRE SAFETY INFORMATION PACK

FIRE RISK ASSESSMENT WORKED EXAMPLE

1.0 APPOINTMENTS 2.0 FIRE RISK ASSESSMENTS

NORTH BIRMINGHAM ACADEMY

Fire Safety Log Book

Fire Risk Assessment for Simple Premises Guidance Notes

Site Induction Presentation

EMERGENCY ACTION AND FIRE PREVENTION PLAN

Waterloo Campus Directorate of Estates & Facilities - Document No. HS14 V4.1 Dated January 2015

FIRE RISK ASSESSMENT. The Workplace Fire Precautions Legislation

Fire Risk Assessment

1.1.4 The findings from Fire Risk Assessment must be incorporated into the FRAMS Action Plan to manage fire safety at each premise.

Introduction Management Tenancy terms Applying Licence agreement Payment of fees Insurance Moving in...

1. Fire Safety Policy and Responsibilities. Consult the Employer s Fire Safety Policy and establish responsibilities of staff for fire safety.

(Sample) Building Emergency Plan

Safety and Health Office WORKPLACE SAFETY CHECKLIST

Buildings used for locations or temporary studios in film and television

RESIDENTS FIRE SAFETY INFORMATION PACK

Fire alarm bells (and associated fire detection equipment) are tested on Wednesday mornings between

FIRE AND LIFE SAFETY TRAINING

FIRE SAFETY MANUAL. Table of contents can be found on the left side of this document.

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

The terms hazard and risk are often used, which we define as the following:

LANCASTER UNIVERSITY. MANUAL OF SAFETY Section 29 POLICY ON FIRE RISK ASSESSMENTS

Strand Campus London Directorate of Estates & Facilities - Document No. HS13 V4 Dated January 2014

Fire safety advice for landlords

Gatehouse School. Fire Risk Assessment

Fire risk assessment a guide for businesses

FLA S FIRE SAFETY INITIATIVE

Quorn Hall International Centre Visitor Risk Assessment

Your responsibilities if you have an automatic fire alarm. A handy guide for owners and responsible persons

ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website

For use by landlords of small premises Premises Address

The Imperial College Healthcare NHS Trust. A guide to your onsite key worker accommodation

FIRE SAFETY SIGNAGE - UCL FIRE SAFETY STANDARD

The Occupant Handbook

FIRE SAFETY FOR OFFICE WORKERS

MINNESOTA HEALTH CARE ENGINEERS IN ASSISTED LIVING FACILITIES

For use by landlords of small premises Premises Address

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

An inventory of hazardous materials used in your workplace will prove useful.

Stawell Health & Community Centre

Lee Baron FIRE RISK ASSESSMENT

To promote and protect the private residential landlord. Fire Safety Logbook. Information. Advice. Support. Services START DATE:

NY Fire Safety Institute

Carrying Out and Recording a Fire Risk Assessment

exit routes and fire protection

Restaurant & café guide

Core & Shell Construction. Rules and Regulations

Dennis Fire Department Fire Prevention Mark Dellner Fire Chief

Managing fire safety in the workplace

Beth Israel Deaconess Medical Center Environment of Care Manual

FIRE SAFETY PRECAUTIONS

BS5839 Part 1:2002 Overview

HYDE PARK SCHOOL, Marble Arch CRISIS MANAGEMENT PLAN

FIRE DETECTION AND ALARM SYSTEMS

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

Emergency Evacuation Plan: 232 King St.

Room Booking Agreement

Berkeley Castle. Occupant Fire Safety

Fire detection in kitchens

Hotel Fire Safety for staff

Introduction. Pre-Arrival. Arrival & Car Parking Facilities. Main Entrance, Reception & Ticketing Area

Name Of Occupancy Date. Yes No Describe

BRITISH SCHOOL OF GENEVA HEALTH AND SAFETY POLICY

ROYAL HOLLOWAY, UNIVERSITY OF LONDON: GENERAL RISK ASSESSMENT FORM

BRO Roles & Responsibilities Form Page 1 of 9

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

Workplace Safety Inspections Adopt a systematic approach by inspecting 8 areas of safety:

A. OCCUPANT FIRE PROCEDURES... 3 B. THE TENANT FIRE SAFETY TEAM... 6 C. SENIOR FIRE WARDEN... 7 D. DEPUTY FIRE WARDEN... 8

FIRE SAFETY REGISTER. Premises Name: Premises Address: Fire Safety Manager: Contact No. Kerry County Fire Service

Workplace Fire Safety

Student House Australia Rules and Procedures

Fire Safety. Workbook Second Edition, 2004

POLICY ON HEALTH AND SAFETY (GENERAL)

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

ESTABLISHMENT OF A NEW BUSINESS

Transcription:

SBR FIRE RISK ASSESSMENT Report of audit and inspection Premises Details Occupier Premises Address Premises Description Times premises are in use Use and maximum no. people present The British School of Osteopathy 98-118 Southwark Bridge Road, London SE1 0BQ Ground floor clinic in a multi-use building Monday-Thursday: 8am 8.30pm Friday: Saturday: 8am 6.30pm 8am - 1pm The building is used as a clinical centre for student osteopaths. Date February 2015 Review Date February 2016 Page 1 of 6

1. Fire Hazards 1.1. Sources of Ignition Hazard Control Measures Action required Progress Electrical equipment Wiring and electrical sockets Smoking Gas fired boilers 1.2. Sources of Fuel All electrical equipment is PAT Tested. The building has a Periodic Inspection of the wiring every 5 years. Smoking is not allowed near the building. Maintenance contract on boilers carried out by a registered contractor includes servicing of flue and pipework Due to be carried out August 2016 Hazard Control Measures Action Required Progress General office equipment Paper Rubbish Cleaning products 1.3. Sources of Oxygen Room users are encouraged to keep rooms tidy and remove any redundant items. Annual Health and Safety walk rounds Paper is not stored near sources of ignition wherever possible. Posters near corridors and fire escapes are either displayed in covered notice boards or laminated Bins are emptied daily and waste is stored in the central rubbish area on Store Street for collection Cleaning products stored securely in cleaners cupboard away from sources of ignition. Cleaners trained in COSHH Regulations before commencing work on site. COSHH safety data sheets available for all products. There are no sources of oxygen other than the air. 1.4. Hazards from Work Processes Consider ways of reducing the amount of paper used/stored in the building No processes carried out by internal staff produce fire hazards. Occasionally contractors are employed to carry out a task which involves hot works. In these cases, a hot works permit is issued to the contractor by the Facilities Department before any work is carried out. Page 2 of 6

2. People at Risk Core hours of the building: Monday to Friday 08:00-17:30 Additional opening hours: Monday to Thursday 17:30-20:30 Saturday 08.00-13.00 The building is used by staff and students as well as patients and visitors. Evening and Saturday clinic runs at a lower capacity than the general weekday clinic and therefore there are significantly less people in the building out of core hours. The building occupies the ground floor of the building at 98-118 Southwark Bridge Road. In the event of an emergency there are four exits to the building. These are clearly marked on the evacuation plans which are located at strategic points in the clinic. New staff and students are given an introduction to Health & Safety as part of their induction and are shown the location of the fire escapes and given a copy of the Health & Safety Policy and the Evacuation Procedures. Patients are never left unattended and therefore always have a student or staff member nearby to direct them to the nearest fire exit. Signage is up around the building and building users are encouraged to locate the nearest fire exit. Page 3 of 6

3. Detection and Prevention The building is fitted with a fire alarm system to alert people to evacuate the building in the event of a fire. The system consists of: 1 x Ziton Control Panel (installed April 2008) + 1 repeater unit 64 x Smoke detectors 4 x Heat Detectors 5 x Call points 68 x Sounders The detectors are grouped into two zones which are displayed next to the Fire Alarm Panel and the repeater panel. The system is either triggered automatically by the smoke detectors or manually by the call points within the clinic or by the activation of the alarm system for the commercial units above. Fire drills are carried out bi-annually in January and July. In the event of a power failure, emergency lighting will illuminate the rooms and corridors. There are 103 emergency lights distributed throughout the building providing ample lighting. There are sufficient fire extinguishers throughout the building. For locations see Appendix 1. Type of extinguisher Use Quantity Water Organic solid materials such as wood, cloth, paper, 2 plastics etc. Do not use on electrical appliances Carbon Dioxide Electrical equipment 7 Foam Burning liquids 4 Fire Blanket Small solid or liquid fires mainly in kitchens 2 During core hours and timetabled weekend teaching hours, trained fire wardens are in the building to ensure everyone follows the procedures and evacuates in a timely and orderly fashion. There are fire wardens based throughout the building. Procedures are given to each fire warden detailing their role and responsibilities in the event of a fire. Fire doors are marked with signs and are kept closed at all times. All doors are fitted with thumb turn latches to ensure they can be opened from inside in the case of an emergency. All magnetically locked doors are fitted with green break glass units. By breaking the glass, the magnets will automatically release allowing the doors to remain unlocked. Page 4 of 6

4. Records and Training The fire alarm is tested weekly on Tuesday mornings. Weekly building inspections are carried out to ensure fire exits are clear and no hazards have arisen. Records are kept in the Fire Log Book. Annual reviews are carried out of the Fire Risk Assessment and Health & Safety Risk Assessment unless changes are made and the review is brought forward. The School s Fire Safety contractor services and inspects the Emergency Lights, Fire Extinguishers and Alarm System at the following frequencies: Service Frequency (per annum) Month due Fire Alarm Maintenance 2 October, April Emergency Lights 1 October Fire Extinguishers 1 April Records of their visits are kept in the Fire Log Book. Fire Warden training lasts for two years. Regular reviews are carried out of the number of fire wardens available and training is carried out as necessary. Page 5 of 6

Appendix 1: Fire Extinguisher Locations Site Floor Location Type SBR Sth Exit to Res lobby Foam SBR Sth Exit to Res lobby CO2 SBR Sth Locker room CO2 SBR Sth Rear Fire Exit H2O SBR Sth Rear Fire Exit CO2 SBR Sth Tea point Blanket SBR Nth Fire Exit Rm 11 Foam SBR Nth Fire Exit Rm 11 CO2 SBR Nth Back Office Blanket SBR Nth Exit to Res lobby Foam SBR Nth Exit to Res lobby CO2 SBR Nth O/s Rm 2 Foam SBR Nth O/s Rm 2 CO2 SBR Nth Plant Rm CO2 SBR Nth Reception H2O SBR Nth Reception CO2 SBR Nth Boiler Rm (Ext) CO2 Page 6 of 6