FACTORY AUTOMATION. Manual. Speed Monitor KHU8-DW-1.D



Similar documents
PROCESS AUTOMATION MANUAL OVERSPEED/UNDERSPEED MONITOR KF**-DWB-(EX)1.D ISO9001

Short information Parameters are programmed via front-side membrane keypad

Speed Control Relays SX2

Multifunction devices

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

SYSTEM DESCRIPTION Termination Boards

FACTORY AUTOMATION MANUAL ID-NET SETUP PROCEDURE USING PROGRAMMING BARCODES

Preset Counter signo 721

SAFETY MANUAL SIL Switch Amplifier

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

Modular I/O System Analog and Digital Interface Modules

AUTOMOTIVE EXCELLENCE

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

SAFETY MANUAL SIL RELAY MODULE

Control Devices Catalogue. Control Devices. Preferred and Standard Products

Installation manual. Generator Paralleling Controller GPC multi-line C

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Quick Connect. quick - simple - efficient.

TLK 48 MICROPROCESSOR-BASED DIGITAL ELECTRONIC REGULATOR

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

PROCESS AUTOMATION REMOTE I/O SYSTEMS RPI REMOTE PROCESS INTERFACE IN THE SAFE AREA OR IN ZONE 2

ABB i-bus EIB Logic Module LM/S 1.1

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Description. Dimensions. Features. precision works better

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

Panel Meters and Controllers Modular Panel Meter Type EDM 35

How To Use A Network Card With A Network Box (Ios) On A Microsoft Powerbook 2.5 (I2) (I3) (Io2) And I2 (Io) (Net) (Ipo) (

Process Alarm Solutions

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

FACTORY AUTOMATION EXPERTISE AND SERVICE OPEN DOORS RADAR SENSORS FROM PEPPERL+FUCHS

FACTORY AUTOMATION INTELLIGENT CLAMP MONITORING FOR MACHINE TOOL SPINDLES WITH INDUCTIVE POSITIONING SYSTEMS

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

GAE953 Electrical Alarm Unit 19" with Indicator

ABB Drives. User s Manual HTL Encoder Interface FEN-31

Centro-Matic Automatic Lubrication Systems System Controls

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

FACTORY AUTOMATION LGS SERIES INTELLIGENT

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

OPERATING PRINCIPLES FOR PHOTOELECTRIC SENSORS

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

PNOZsigma - Base units

Polyphase kwh Electricity Meter

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

HERZ-Thermal Actuators

Product and functional description

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

ALARM ANNUNCIATOR ME INSTRUCTION MANUAL

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

SAFETY MANUAL SIL SWITCH AMPLIFIER

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

Duct Humidity Transmitter

Electronic Pressure Switch EDS 3000

38 Series - Relay interface modules A

Electrical connection

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

38 Series - Relay interface modules A

How To Make An Ultrasonic Sensor

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Data Sheet. Electro-mechanical counters Hengstler 800 series

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Electronic Pressure Switch EDS 300

Operation Manual. Plasma torch height controller. Model: Compact THC Controller 150

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Single Channel Loop Detector

GT Sensors Precision Gear Tooth and Encoder Sensors

Isolating Barriers for our sensors A5S1 in Ex-areas Series D461

80 Series - Modular timers 16 A. Features

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Power source. Input. Contact / Open collector Voltage input (SELECTABLE) AC V DC12-24V AC V. Output indicator

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

FACTORY AUTOMATION MANUAL USB VIRTUAL COM PORT DRIVER INSTALLATION UNDER WINDOWS XP/WINDOWS 2000

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

Flexible Counter Series in DIN size 24 x 48 mm

FLOW CALCULATOR INSTRUCTION MANUAL MESURES BAMOPHOX M1 02 E MES FLOW CALCULATOR /1

RS - SPM. Serial parallel translator module

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Solid State Timers Type F

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Safety technique. Emergency stop module BO 5988 safemaster

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

Throughbeam photoelectric sensors. Dimensioned drawing. Electrical connection

THE INPUT/OUTPUT SYSTEM. Key Points

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

is then retained absolutely without interruption.

Inductive Proximity Sensors

Transcription:

FACTORY AUTOMATION Manual Speed Monitor KHU8-DW-.D

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, as published by the Central Association of the 'Elektrotechnik und Elektroindustrie (ZVEI) e.v.', including the supplementary clause "Extended reservation of title" We at Pepperl+Fuchs recognise a duty to make a contribution to the future. For this reason, this printed matter is produced on paper bleached without the use of chlorine.

Speed Monitor KHU8-DW-.D Speed Monitor KHU8-DW-.D Technical description page. Technical description... 2. Operation 2. Operating mode... 2 2.2 Setting mode... 3 3. Technical data... 4. Terminal allocation... 8 5. Connection diagram... 9 6. Dimensions, description of controls and indicators.... Operation - overview... fold-out page. Technical description The KHU8-DW-.D is a device used to indicate and monitor periodic signals which occur in almost all areas of automation and process engineering, i.e. frequencies in general and rotational speeds in particular. The input signals are evaluated using the cycle method, i.e. by measuring the duration of a period, and then converted by a very fast µ-controller to frequency, or rotational speed. The frequently occuring special case of rotational speed measurement was given particular attention. For this reason, indications and inputs can be either in Hz or in rpm. In addition, the possibility exists, on applications involving lengthy processes, whose sensors provide a number of pulses per revolution, to operate automatically with the actual rotational speed of the drive, by presetting the number of pulses. Indication of the measured value is achieved by means of a 4-digit -segment-led-display on the front of the device, with up to 3 places following the decimal point. The monitoring function is actuated by a limiting value, whose upper and lower hysteresis values can be selected within the appropriate measuring and indicating range. The output signal is generated by a change-over relay when the hysteresis limits are either exceeded or fallen below. Due to its high switching capability, the relay output can be used to directly drive an actuator, or as an input signal to a higher level control. In addition, the switching state of the relay is indicated by a yellow LED on the front face of the device. A function block is connected in line with the output relay, which enables different timer functions to be employed; thus there is no need to connect a separate timer relay in series. In addition to ON delay and OFF delay, defined ON time and pulse lengthening, the direction of operation of the relay, i.e. to monitor underspeed or overspeed, can also be selected. The built-in start-up bypass, triggered by switching on the supply voltage, or by an external signal, prevents false signals from occuring during the start-up of the monitored system. Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Technical description / Operation The speed monitor may be supplied with 5 V AC, 23 V AC or 24 V DC. When an alternating voltage is connected, a 24 V DC source is available for the signal transducer. All currently available two-, three- or four-wire proximity switches and incremental rotary encoders are accepatable as the sensor. Moreover two terminals are reserved for the connection of proximity switches to DIN 9234 (NAMUR). Safety notes: Insulation co-ordinates for specifying data on galvanic/electrical isolation are in accordance with DIN EN 5 8: The KHU8-DW-.D device is intended for use in enclosed electrical operating areas, to which only competent electrical personnel or properly instructed electrotechnical personnel have access or entry. The device is rated for use in conditions of pollution severity class 2, overvoltage category II in accordance with EN 5 8. The device comprises 3 galvanically isolated circuits: 23 V, 5 V voltage supply circuit, connections: 6,, 8 Signal circuit 24 V voltage supply, connections: 4, 5 Sensor/signal, connections:, 2, 3,, 8, 9, 3, 4, 5 Relay output circuit, connections:,, 2 There is no isolation between the signal circuit connections and the exposed/contactable surfaces. 2. Operation 2. Operating mode Signal frequency The speed monitor processes input signals from. Hz... 5 Hz, over 4 measuring ranges, i.e., cycle durations of.2 s to s are evaluated. Signals not having a duty rate of : must have a minimum pulse pause or pulse duration of 2 µs in order to be detected with certainty behind the input filter. Signal has fallen below the measuring range, message This message appears either when no input signal is detected, or if the displayed value would be zero, due to the selection of a measurring range which is too high. Example: The device receives a signal of. Hz in the Hz to 5 Hz measuring and display range. This implies that the display would indicate zero and an observer might presume that the machine had stopped. Signal is above the measuring range, message The set display and measuring range has been exceeded. Solution: Select a larger measuring range. XXX Very low signal frequencies, displayed value is not valid, message During the measurement of very low signal frequencies, the measuring system has detected that the signal has fallen below the last computed frequency, i.e., the time between the last two signal edges has already elapsed. The unit is now waiting for the next positive signal edge, in order to be able to compute the next measured value. Here, 'XXX' represents the positions of the first three digits of the last measured value. 2 Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Operation Self test, message When the supply voltage is switched on, the speed monitor carries out a self test. The message appears when it is established that there is an error, for example during the check summation of the EEPROM data; in this state, the output relay behaves as if there has been a power failure. The error message can be cleared by switching the supply voltage off and then on again. If, on switching on again, the error message U- appears, then the factory presets were loaded, i.e., the parameters must be newly entered. In order to restore the normal function of the output relay, the speed monitor must once again be switched off and then on. 2.2 Setting mode (see also the operating summary on the fold-out page) Password protection The password protection function is not active. The password can be displayed, but not changed. Function selection Two measuring functions are available:. Frequency measurement in Hz The period of duration of the input signal, as determined, is converted to a frequency in Hz by forming the reciprocal value and then displayed. The hysteresis limits of the switch point are also specified in Hz. 2. Rotational speed measurement in rpm (preset at the factory) The signal frequency, derived from the period of duration, is multiplied by 6 and displayed as rpm. The hysteresis limits are likewise specified in rpm. Pulse divider (Preset at the factory: pulse/revolution) Applications involving slow processes are frequently equipped with sensors which provide several pulses per revolution. In the rotational speed measuring function, the device undertakes the conversion to the actual value of rpm by inputting the numerical value (of pulses/revolution), i.e. both the indication and the input of the hysteresis limits are directly obtained from the actual rate of rotation of the drive. Example: In normal operation, a machine rotates at 45 rpm. An incremental rotary encoder providing pulses per revolution is used as the rate of rotation sensing element. The input frequency is 45 rpm x pulses per revolution 6 s/min = 5 Hz A rate of rotation of 45 rpm x pulses/revolution = 45 rpm would be displayed in the rotational speed measuring function. By programming the pulse divider to pulses/revolution, the display would indicate the actual drive speed of 45 rpm. Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com 3

Speed Monitor KHU8-DW-.D Operation Display and measuring range (Preset at the factory:... 999.9) Four measuring and display ranges are available for frequency measurement and three measuring and display ranges are available for speed measurement, as follows: Display in Frequency range Rotational speed Number of parameter editor in Hz in rpm decimal places... 5... 9999..... 999.9.2.... 99.99 2.3.... 9.999 3 Example (continued from above): The maximum permissible rotational speed of the drive is 6.5 rpm. The first two measuring ranges can be selected. However, in order to fully utilise the accuracy of the display, it is recommended that the second measuring range is used. Message This message appears when an attempt has been made to change the range in such a way, that previously input limiting values lie outside the display and measuring range, or the respective places following the decimal point would be cut off. Example (continued from above): The maximum permissible value of 6.5 rpm has already been input as the upper hysteresis limit, and an attempt is being made to change the range to. rpm to 99.99 rpm (the limiting value is outside the display and measuring range), or an attempt is being made to change the range to rpm to 9999 rpm (places following the decimal point would be cut off). Output relay switch points (Preset at the factory: and 2) The output relay switch points are defined by the upper and lower hysteresis limit. When the upper hysteresis limit O_Gr is exceeded, switching is triggered and on falling below the lower hysteresis limit U_Gr, switch back occurs. If no hysteresis limit is desired, i.e., the output relay is required to switch both on and off at a defined rpm, the same value has to be input for both parameters. Example (continued from above): On exceeding the maximum permissible rotational speed of 6.5 rpm, a signal should be activated in the control room. The alarm message should then extinguish when the speed drops again to 5 rpm. The upper hysteresis limit is to be set at 6.5 rpm, the lower at 5 rpm. Message The message GrU? appears if an attempt is made to set a value for the upper hysteresis limit which is lower than the lower hysteresis limit and GrO? is displayed on an attempt to programme a value for the lower hysteresis limit which is larger than the upper hysteresis value. 4 Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Operation Timer functions, reversal of direction of operation of the output relay Time base for the timer functions (Preset at factory:. s) A time between. s and 999.9 s can be set for the timer function of the output relay. Timer functions and reversal of direction of operation (Preset at factory: ) The KHU8-DW-.D speed monitor can be adjusted to any one of different settings, in association with the reversal of direction of operation, in order to modify the switching behaviour of the output relay. In functions to 4, the output relay is active according to the selected time function, when the upper hysteresis value is exceeded. In functions 5 to 9 the sense of operation is inverted, i.e., the relay is active below the lower hysteresis limit. No. Function No. Function no timer function 5 no timer function, inverted ON delay 6 ON delay, inverted 2 OFF delay OFF delay, inverted 3 Defined ON time 8 Defined ON time, inverted 4 Pulse lengthening 9 Pulse lengthening, inverted The ON delay has the effect of causing the timer to start when the upper hysteresis limit is exceeded and the relay to be triggered (retriggerable) when the timer has run out. The OFF delay causes the relay to operate immediately when the upper limiting value has been exceeded. Each time the measured parameter falls below the lower limit the timer is started and as soon as the timer has run out the relay drops out (retriggerable). Defined ON time implies that the relay pulls in when the upper hysteresis limit is exceeded and drops out again after the set time (not retriggerable), independently of further variations in rpm. Pulse lengthening is the means of providing that the relay pulls in when the upper limit is exceeded and drops out as soon as possible when the set time has elapsed (not retriggerable). (See also the graphical representation on page ). Start-up bypass (Preset at factory: 3 s) A start-up bypass time between. s and 999.9 s can be programmed in order to avoid false signals on the start-up of a drive which is to be monitored for underspeed. During this time the device and the output relay behave as if the machine had already exceeded the upper hysteresis limit. The start-up bypass time is started by a positive signal on terminal 2; the positive signal must be at least as long as the bypass time. The start signal can originate from a higher order control, or be generated by the connection of the supply voltage to the speed monitor. In the latter case, terminals 2 and 3 have to be bridged. Example: In normal operation, a machine requires a maximum of 5 s to run up to a nominal speed of 5 rpm. The start-up bypass time has to be set to a value greater than 5 s. When the period of 5 s has elapsed the rpm underspeed monitoring function is active (relay function 5). If the start-up is as scheduled during this time, the relay will not have actuated. If the start-up takes longer than anticipated, then the relay will switch after commencement of the start-up bypass, until the upper hysteresis limit has been reached. Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com 5

Speed Monitor KHU8-DW-.D Operation Figure: Timer functions, reversal of direction of action of the output relay " tstart-up 2 3 4 5 6 8 9 6 Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Operation / Technical data Display rate (Preset at factory:.33 s) In order to ensure good readability of the display, the time taken to indicate the current measured value in the display can be selected between. s and 2.5 s. Software version number The number of the software version can be read only. 3. Technical data Supply voltages 23 V AC ± %, 4 Hz... 63 Hz, < 5 VA (Terminal 6, 8) 5 V AC ± %, 4 Hz... 63 Hz, < 5 VA Terminal, 8) 24 V DC +5/- %, u ss %, < 5 W (Terminal 4, 5) Signal inputs Frequency. Hz... 5 Hz Minimum pulse length/duration: 2 µs NAMUR Switch points:.2 ma; 2. ma (Terminal 8, 9) No load voltage: 8.2 V; Short circuit current: 6.5 ma Impedance:.2 kω PNP-sensor Switch point: 2 V (Terminal 5) Max. input voltage: 3 V Impedance: 2.8 kω NPN-sensor Switch point: 2 V (Terminal 4) Impedance: 3.3 kω Triggerinput Switch point: 2 V (Terminal 2) Max. input voltage: 3 V Impedance: 2.8 kω Output relay Switch state indicator Timer functions Direction of operation Terminal : NO;Terminal : NC; Terminal 2: COM 25 VAC, 2 A, cos ϕ. 4 VDC, 2 A ON/OFF delay (incl. computation time) 2 ms Mechanical life 3 switch cycles 3 mm - yellow LED ON/OFF delay, defined ON time, pulse lengthening Timer period: s... 999.9 s reversible Sensor power supply Terminal 3, 3: L+; Terminal, : L- 24 VDC ± %, U ss %, 3 ma short circuit protected Start-up bypass Triggered by external signal (Terminal 2) or by switching on the supply voltage (Terminal 2 and Terminal 3 bridged) Bypass time:. s... 999.9 s Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Technical data / Terminal allocation Error of measurement. Hz... Hz:. % Hz... khz:.3 % khz... 5 khz:.5 % Display: ± digit Ready delay Display rate of rotation and frequency Design Mounting Terminal connections 4 ms 4-digit -segment-led-display, red, digit height: mm Modular terminal housing of Makrolon By clipping onto 35 mm standard rail according to DIN EN 522 or srew mountable by pull-out clip with 9 mm grid Self-opening instrument terminals cross sectional area: 2 x 2.5 mm 2 Operating temperature -25 C... + C Storage temperature -4 C... +85 Pollution severity class 2 Protection class IP 2 EMC to EN 58-2, EN 582-2 Overvoltage category II in accordance with EN 5 8. 4. Terminal allocation Term. : Sensor power supply, GND Term. 2: Trigger input for start-up bypass Term. 3: Sensor power supply, 24 V DC Term. 4: Power supply, 24 V DC Term. 5: Power supply, GND Term. 6: Not connected Term. : Sensor power supply, GND Term. 8: NAMUR input L- Term. 9: NAMUR input L+ Term.: Relay normally open contact, NO Term.: Relay normally close contact, NC Term.2: Relay root, COM Term.3: Sensor power supply, 24 V DC Term.4: for NPN-sensor Input Term.5: for PNP-sensor Input Term.6: Power supply L, 23 V AC Term.: Power supply L, 5 V AC Term. 8: Power supply N 8 Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Connection diagram 5. Connection diagram Bridge fitted: start-up bypass triggered by switching on the power supply. External trigger signal Power supply 24 V DC or Power supply 23 V AC or Power supply 5V AC Relay output 3 2 6 4 5 6 8 2 Sensor power supply 24 V DC Trigger input for start-up bypass Sensor power supply GND Not connected L+ L L (23 V~) N L (5 V~) COM NC NO yellow NAMUR + NAMUR Sensor power supply 24 V DC Input for PNP Output circuit Input for NPN Output circuit Sensor power supply GND 9 8 3 5 4 NAMUR Sensor 9 8 L+ L- DC-3 wire sensor PNP 3 L+ 5 L- DC-2 wire sensor 3 L+ 5 Rotary encoder, Push-pull output stage 3 L+ 5 L- TX NAMUR Rotary encoder 9 8 L+ TX L- DC-3 wire sensor NPN 3 L+ 4 L- DC-2 wire sensor 4 L- Rotary encoder, Push-pull output stage 3 L+ 4 L- TX Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com 9

Speed Monitor KHU8-DW-.D Dimensions 6. Dimensions, description of controls and indicators Yellow LED, Relay switch state indication segment display Control keys MODE and + : Start parameter editor + : Select parameters or Increase value of flashing number - : Select parameters or Decrease value of flashing number MODE : Display parameter value, left number is flashing or Move flashing number to the left side ENTER : Quit parameter display, now the unit is operating with the modified parameter. ENTER und + : Quit parameter editor, the parameters will be permanently memorized in the EEPROM. Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

Speed Monitor KHU8-DW-.D Operation overview Operating mode Password protection not activated. Password may not be edited. X=: frequency measurement. Hz...5 Hz X=: rotational speed measurement. r.p.m...9999 r.p.m. Preset at the factory: X= Number of pulses per revolution for rotational speed measurement (will be ignored for frequency measurement) XXXX 2 Preset at the factory: XXXX= Measuring and display range Frequency measurement: X 3 Rotational speed measurement: X 2 Preset at the factory: X= X Frequency range Rotational in Hz speed in rpm... 5... 9999..... 999.9.2.... 99.99.3.... 9.999 Lower hysteresis limit of switching point XXXX 9998 (depending on the measuring range) Preset at the factory: XXXX= Upper hysteresis limit of switching point. XXXX 9999 (depending on the measuring range) Preset at the factory: XXXX=2 Period for the timer function of switching relay. s XXX.X 999.9 s Preset at the factory: XXX.X=. s Period for the timer function of switching relay Preset at the factory: X= X Function No timer function ON delay 2 OFF delay 3 Defined ON time 4 Pulse lengthening 5 No timer function, inverted 6 ON delay, inverted OFF delay, inverted 8 Defined ON time, inverted 9 Pulse lengthening, inverted Start-up bypass. s XXX.X 999.9 s Preset at the factory: XXX.X=3. s Display rate. s XX.X 2.5 s Preset at the factory: XX.X=.33 s The number of the software version can be read only. Pepperl+Fuchs Group Tel.: Germany (6 2) 6- USA (3 3) 4 25 35 55 Singapore 9 9 9 Internet http://www.pepperl-fuchs.com

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, as published by the Central Association of the 'Elektrotechnik und Elektroindustrie (ZVEI) e.v.', including the supplementary clause "Extended reservation of title" We at Pepperl+Fuchs recognise a duty to make a contribution to the future. For this reason, this printed matter is produced on paper bleached without the use of chlorine.

One Company, Two Divisions. Factory Automation Division Process Automation Division Product Range Digital and anaogue sensors in different technologies Inductive and capacitive sensors Magnetic sensors Ultrasonic sensors Photoelectric sensors Incremental and absolute rotary encoders Counters and control equipment Identification Systems AS-Interface Areas of Application Machine engineering Conveyor or transport Packaging and bottling Automotive industry Product Range Signal conditioners Intrinsically safe interface modules Remote Process Interface (RPI) Intrinsically safe field bus solutions Level control sensors Process measuring and control systems engineering at the interface level Intrinsic safety training Areas of Application Chemical industry Industrial and community sewage Oil, gas and petrochemical industry PLC and process control systems Engineering companies for process systems Service Area Worldwide sales, customer service and consultation via competent and reliable Pepperl+Fuchs associates ensure that you can contact us wherever or whenever you need us. We have subsidiaries worldwide for your convenience. The Pepperl+Fuchs Group USA Headquaters Pepperl+Fuchs Inc. 6 Enterprise Parkway Twinsburg, Ohio 448 Cleveland-USA Tel. (33) 4 25 35 55 Fax (33) 4 25 93 85 E-Mail: sales@us.pepperl-fuchs.com Asia Pacific Headquaters Pepperl+Fuchs Pte Ltd. P+F Building 8 Ayer Rajah Crescent Singapore 39942 Tel. (65) 9 9 9 Fax (65) 8 3 6 3 E-Mail: sales@sg.pepperl-fuchs.com Worldwide Headquaters Pepperl+Fuchs GmbH Königsberger Allee 8 683 Mannheim Deutschland Tel. +49 62 6- Fax +49 62 6- http://www.pepperl-fuchs.com E-Mail: fa-info@de.pepperl-fuchs.com Subject to reasonable modifications due to technical advaces Copyright PEPPERL+FUCHS Printed in Germany Part. No. 39 8 2/99 4