ENERGY SAVING OF OIL HYDRAULIC PUMP UNIT BY IDLING STOP METHOD USING AN ACCUMULATOR

Similar documents
Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

6. VVT-i (Variable Valve Timing-intelligent) System

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Example. Fluid Power. Circuits

Material taken from Fluid Power Circuits and Controls, John S. Cundiff, 2001

Motors and Inverters for Environmentally Friendly Industrial Equipment

Energy Recovery System for Excavators Meng (Rachel) Wang, Chad Larish Eaton Corporation

Schematic Symbols Chart (Design Hydraulic and Pneumatic circits)

Centrifugal Fans and Pumps are sized to meet the maximum

HYDRAULIC CIRCUIT DESIGN AND ANALYSIS

ACCUMULATOR INSTALLATION

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

With the background of fulfilling public commitments for ECONO-PILOT ENERGY-SAVING SYSTEM FOR WATER PUMPS

Introduction to Process Control Actuators

Unit 24: Applications of Pneumatics and Hydraulics

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Unit 24: Applications of Pneumatics and Hydraulics

TECHNICAL INFORMATION Bulletin

ADVANCED CONTROL TECHNIQUE OF CENTRIFUGAL COMPRESSOR FOR COMPLEX GAS COMPRESSION PROCESSES

Unit 24: Applications of Pneumatics and Hydraulics

The Secret of Hydraulic Schematics. BTPHydraulics

Hydraulic Troubleshooting PRESENTED BY

Electric Coolant Pumps. Always at the Correct Temperature

understanding medium frequency induction melting furnace and its components

HYDRAULIC ACCUMULATOR. Energy buffering applications APPLICATIONS OSP 035. Applications with short term high quantity oil requirements

OUTCOME 1 TUTORIAL 1 - MECHATRONIC SYSTEMS AND PRODUCTS

Guidelines for operation of minimum flow control valves

THE THERMAL FLOW METER, A GAS METER FOR ENERGY MEASUREMENT

Radial piston pumps type R and RG

When looking at machine tools, the details of the installed drive technology usually

Recognizing and understanding schematic symbols will enable you to comprehend a circuit s function.

CENTRIFUGAL PUMP SELECTION, SIZING, AND INTERPRETATION OF PERFORMANCE CURVES

Basic Symbols. Lines. Circular. Square. Diamond. Miscellaneous Symbols. -continuous line - flow line. -dashed line - pilot, drain

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

Unit 24: Applications of Pneumatics and Hydraulics

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

Fault Diagnosis and Maintenance for CNC Machine. Based on PLC

P = n M 9550 [kw] Variable Intake Manifold in VR Engines. Self-study programme 212. Principles and Description of Operation. Service.

1. EXTERNAL ALARM MESSAGE

Introduction to Electronic Signals

MECHANICAL ENGINEERING EXPERIMENTATION AND LABORATORY II EXPERIMENT ENGINE PERFORMANCE TEST

Introduction of Duplex Pump HPD71+71 and Short-Stroke Pump HPV

Development of Combined Automatic Blade Control for Snow-Removing Grader

CIM Computer Integrated Manufacturing

RECYCLED MICRO HYDROPOWER GENERATION USING HYDRAULIC RAM PUMP (HYDRAM)

Section IV VACUUM PUMPS. Vacuum Pumps: Basic Operation

UNIVERSITY OF WATERLOO ELECTRICAL & COMPUTER ENGINEERING DEPARTMENT ME269 ELECTROMECHANICAL DEVICES AND POWER PROCESSING.

Asset Management and Condition Monitoring

Water hammering in fire fighting installation

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Development of Power Supply System with Hybrid Turbocharger for Marine Application

Pressure Relief and Regulating Valves

NO LOAD & BLOCK ROTOR TEST ON THREE PHASE INDUCTION MOTOR

Test Report issued under the responsibility of:

SIMPLIFIED VALVE CIRCUIT GUIDE

Basic Hydraulics and Pneumatics

Thermodynamic efficiency of an actuator that provides the mechanical movement for the driven equipments:

8.1 HPC for improved efficiency on standard machine tools by using new fluid-driven spindles

CNC MILLING MACHINE TROUBLE SHOOTING. 1. Trouble Shooting. No Trouble Solution. 1.Check the air pressure

Development and testing of a multi-type air conditioner without using AC inverters

Series TMM Axial Piston Motor. Technical Information

Irrigation Pump Variable Frequency Drive (VFD) Energy Savings Calculation Methodology. Public Utility District No. 1 of Chelan County

Flow divider (flow distributor), type TQ

HRB Hydrostatic Regenerative Braking system from Rexroth for commercial vehicles:

Physics 41, Winter 1998 Lab 1 - The Current Balance. Theory

Electronic Diesel Control EDC 16

Ship Propulsion/Electric Power Hybrid System Recovering Waste Heat of Marine Diesel Engine

Experiment 3 Pipe Friction

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

Chapter 11 SERVO VALVES. Fluid Power Circuits and Controls, John S.Cundiff, 2001

Real Time Simulation for Off-Road Vehicle Analysis. Dr. Pasi Korkealaakso Mevea Ltd., May 2015

General Background. Closed Circuit Hydraulic Systems. Closed Circuit Hoisting. Safety Problems with Closed Circuit Hoisting

OPERATING FANS IN PARALLEL IN VIEW OF VARIABLE FLOW RATE OUTPUT

ngenieros Ingenieros Asociados De Control S.L.

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

PROGRAMMABLE LOGIC CONTROL

Delta Power Company 4484 Boeing Drive - Rockford, IL 61109

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

How To Install A Mazzei Injector

Learning Systems Software Simulation

DIRECT MATCHING TO GRID WITHOUT INVERTER VARIABLE PITCH. 20/24/30 mt TOWER WITH HYDRAULIC SYSTEM YAWING SYSTEM SAFETY LEVELS PLC CONTROL

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype INVERTER SPLIT TYPE ROOM AIR CONDITIONER. Models Indoor unit Outdoor unit

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Rexroth Hydraulic Pump A10VO Series User Manual

ROTARY GEAR FLOW DIVIDERS

Hydraulic Control Technology for Wind Turbine Generators

ELECTRIC CENTRAL HEATING FLOW BOILER

Lithium-Ion Battery Pack for Stop & Start System *

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

APPENDIX A CONTROL VALVE TESTING PROCEDURES AND EQUATIONS FOR LIQUID FLOWS

Series description: Wilo-Drain TC 40

CNC Machine Control Unit

Electrical Systems - IQAN Digital Control System. IQAN Control System Components

Electronic Manual Gearbox

Energy efficiency and fuel consumption of fuel cells powered test railway vehicle

Closed-Loop Motion Control Simplifies Non-Destructive Testing

Advance Electronic Load Controller for Micro Hydro Power Plant

Fluid Power Formula. These Formula Cover All Fluid Power Applications In This Manual

Pneumatic control for robotics and industrial automation Author: Naresh Raghavan

Transcription:

ENERGY SAVING OF OIL HYDRAULIC PUMP UNIT BY IDLING STOP METHOD USING AN ACCUMULATOR Katsumasa Suzuki 1, Yoshitaka Niimura 1, Kazutoshi Akitani 1 and Ken Sugimura 2 ABSTRACT In recent years, energy saving has advanced in various fields due to the shortage of energy resources such as oil and the need to protect the earth s environment. Energy saving is also very important in the hydraulic industry field. If an accumulator is used for a hydraulic pump unit, intermittent operation of the electric motor for the pump drive, called "idling stop type operation," is attained by using the pressure holding function of the accumulator. Consequently, a reduction of useless power consumption can be realized. In this research, a hydraulic pump unit of the intermittent operation with an accumulator (called "ACC pump unit"), a hydraulic pump unit of an inverter control type ("INV pump unit"), and a hydraulic pump unit with a variable displacement pump ("VD pump unit") are tested. The power consumption, pump output pressure, pump rotation speed, and energy efficiency in one cycle of each pump unit were measured when the same work was done. As a result, the energy efficiency was 4% for the ACC pump unit, 15% for the INV pump unit, and 11% for the VD pump unit. Therefore, the ACC Pump Unit was shown to have the most excellent energy-saving effect. Keywords: Energy Saving, Oil Hydraulic Pump, Efficiency, Accumulator, Idling Stop 1. INTRODUCTION In recent years, energy saving has advanced in various fields due to the shortage of energy resources such as oil and the need to protect the earth s environment. Energy saving is an important subject in the hydraulic field. As an example, if an accumulator is used for a hydraulic pump unit, intermittent operation of the electric motor for the pump drive, called "idling stop type operation," is attained by using the pressure holding function of the accumulator, and useless power consumption is reduced. 1 Department of Mechanical systems Engineering, Tokyo City University (former name: Musashi Institute of Technology), Tamazutsumi, Setagaya, Tokyo 158-8557, Japan, Email:ksuzuki@sc.musashi-tech.ac.jp 2 Nippon Accumulator CO., LTD.

In this research, a hydraulic pump unit of intermittent operation type with an accumulator (ACC pump unit) is compared with an inverter control type pump unit (INV pump unit) and a variable displacement type pump unit (VD pump unit). Clarifying the energy-saving effect of the intermittent operation hydraulic pump unit with an accumulator is the primary purpose of this research. Fig. 1 Experimental equipment 2. EXPERIMENTAL DEVICE and EXPERIMENTAL METHOD A photograph of the experimental device used in this research is shown in Fig. 1. A schematic illustration of the experiment device is shown in Fig. 2. In Fig. 2, 1 shows the work portion of the equipment. It is assumed that a workpiece is gripped by a machine tool and cut with exchanging cutting tools. A pressure supply of more than 2.6 MPa is necessary. A hydraulic-pump unit (made by company A) is shown in 2. This unit has an accumulator and a pressure switch. The INV pump unit (made by company B) is shown in 3. The VD pump unit is shown in. The working fluid is supplied by, 3 or to 1. This figure shows that 1 and 2 are connected and hence the working fluid is supplied by the ACC pump unit. The parameter values for each pump unit are shown in Table 1. The contents and required time for one cycle of work are shown in Table 2. This one cycle is common to ACC pump units, INV pump units and VD pump unit. The parameters listed and the time required assume that a workpiece is held with a machine tool, cut with exchanging cutting tools, and the control is executed by a micro sequencer. Table 1 Parameter values ACC pump unit VD pump unit INV pump unit Displacement volume [cc/rev] 8. (Maximum) 5.7 (Fixed) Maximum operating pressure [MPa] 4. 4. Rated output of electrical motor [kw].75 1.5 2

Cylinder Chuck Tool Stand Pressure Switch Accumulator M ACC pump unit C/R M M INV pump unit M VD pump unit Fig. 2 Experimental circuit 3

Table 2 Details of one cycle of operation No. Contents Operation time[s] 1 Waiting 5 2 Cylinder progress 1 3 Waiting 5 4 Cylinder regress 1 5 Unclamp of Tool Stand.85 6 Rotation of Tool Stand 3.4 7 Clamp of Tool Stand 1 8 Waiting 5 9 Three times repetition from 5 to 8 3.75 Total time of 1 cycle 53 Air supply valve Bladder Poppet valve JIS Mark Hydraulic Oil Fig. 3 Accumulator 2.1 ACC Pump Unit As shown in Fig. 3, a bladder type accumulator with a capacity of 3 L is used in this experiment (Japan Accumulator, 26). The bladder is filled with nitrogen. If the pump output pressure exceeds 3. MPa as the high-limit-setting pressure, the pump drive motor of the ACC pump unit is turned OFF by the pressure switch. If the pump output pressure is less than 2.6 MPa, the pump drive motor is turned ON. The working fluid is discharged or stored by the accumulator according to the pressure change. Although the pump is variable displacement type, it works almost the same as a fixed displacement type in the pressure range of 2.6-3. MPa, since the cutoff pressure is set at higher value than these. 2.2 INV Pump Unit Inverter control is widely used for energy saving of the hydraulic pump unit. The load pressure signal detected by the pressure sensor is inputted into the inverter controller. The pressure is kept constant by changing the frequency of the electric power of the electric motor drive, changing the pump rotation speed and adjusting the flow rate. The target output pressure is 2.6 MPa, which is the minimum pressure required for operation. 4

2.3 VD Pump Unit The experiment in this study is executed on the condition that the pressure switch of the ACC pump unit is always set to the ON state. In addition, the stop valve at the accumulator entrance is shut and the accumulator does not work in the experiment of this hydraulic pump unit. 3. EXPERIMENTAL RESULTS 3.1 One Cycle of ACC Pump Unit The measured results of the power consumption, pump rotation speed, and pump output pressure in one cycle of the ACC pump unit are shown in Fig. 4. The pump is driven when the pump output pressure is less than 2.6 MPa. The pump is turned OFF when the pressure exceeds 3. MPa. Working fluid is supplied from the accumulator in the interim. The output pressure sometimes shows a spike. This is produced when the oil flow changes instantaneously with the switch of an electromagnetic valve. Electric power is consumed only at the time of pump rotation. 3.2 One Cycle of INV Pump Unit The measured results of the power consumption, pump rotation speed, and pump output pressure in one cycle of the INV pump unit are shown in Fig. 5. The pump output pressure is constant at the target pressure of 2.6 MPa. Namely, if the pump output pressure is less than 2.6 MPa, the pump rotation speed increases and the flow rate increases. The pump output pressure is held at the target pressure 2.6 MPa by lowering the pump rotation speed and decreasing the flow rate if it exceeds 2.6 MPa. However, the rotation speed does not decrease to less than 4 rpm. The power consumption changes almost proportionally to the pump rotation speed. 3 25 Output pressure 5 4 3 Electric power[w] 2 15 1 5 Rotation speed Electric power 2 1-1 -2 Pressure[MPa] -5 5 1 15 2 25 3 35 4 45 5-3 -4-5 Time[s] Fig. 4 Electric power, rotation speed and output pressure in one cycle of ACC pump unit 5

3 25 Output pressure 5 4 3 Electric power[w] 2 15 1 Rotation speed Electric power 2 1-1 -2 Pressure[MPa] 5-3 -4 5 1 15 2 25 3 35 4 45 5 Time[s] -5 Fig. 5 Electric power, rotation speed and output pressure in one cycle of INV pump unit Electric power[w] 3 25 2 15 1 5 Output pressure Electric power Rotation speed 5 1 15 2 25 3 35 4 45 5 7 6 5 4 3 2 1-1 -2-3 -4-5 -6-7 Pressure[MPa] Time[s] Fig. 6 Electric power, rotation speed and output pressure in one cycle of VD pump unit 6

3.3 One Cycle of VD Pump Unit This experiment was conducted by using the ACC pump unit keeping the pressure switch set at the ON state. The measured result is shown in Fig. 6. Since the pressure switch is not turned off in this case, the pressure rises to more than 3 MPa. Because the variable displacement pump is used, the amount of pump discharge decreases when the output pressure becomes more than the set value. Thus, pressure regulation is carried out. The pump full-cutoff pressure is set at 3.8 MPa. The pump rotation speed is approximately 148 rpm. The power consumption is similar to that of the INV pump unit in Fig. 5. Although this experiment differs in the method of energy saving, both pump units use energy slightly exceeding the necessary work. When the same work is done, the change of power consumption becomes similar in shape. 3.4 Consumed Electricity and Energy Efficiency of Each Hydraulic Pump Unit The consumed electricity in one cycle of each hydraulic pump unit is shown in Fig. 7. In the idling stop operation of the ACC pump unit, a reduction of approximately 63% of the power consumption is made in comparison with that of the INV pump unit. Next, the energy efficiency in one cycle of each hydraulic pump unit is computed. First, the consumption power of the load side in one cycle is computed by equation (1). E 1 cycle PL V1cycle = (1) Here, E 1cycle [J] is the consumption energy of the load side in one cycle, P L [Pa] is the necessary load pressure, and V 1cycle [m 3 ] is the output flow volume in one cycle. In this experiment, P L = 2.6x1 6 Pa, V 1cycle =1.27x1-3 m 3, and so E 1cycle =3.31 kj. From the consumed electricity in one cycle of each hydraulic pump unit and the load side consumption energy E 1cycle, the energy efficiency of each hydraulic pump unit is computed and shown in Fig. 8. The energy efficiency is 11% in the VD pump unit, 15% in the INV pump unit and 4% in the ACC pump unit. 3.5 Measurement of Static Characteristics of the Hydraulic Pump 3.5.1 Static characteristics of ACC pump unit To measure the static characteristics of the pump of the ACC pump unit, a flow meter and a flow metering valve are connected to the ACC pump unit, as shown in Fig. 9. The pressure switch is kept ON. This result is also a measurement of the static characteristics of the VD pump unit. The flow metering valve is adjusted, output pressure is changed, and then flow rate Q [m 3 /s], electric motor power consumption for pump drive L N [W] and pump output pressure P [Pa] are measured. Output power L [W] and pump efficiency [%] are computed from equations (2) and (3) using these values. L = Q P (2) o o o L η = 1 (3) L N 7

Electric energy consumption[kj] 35 3 25 2 15 1 5 29.2kJ 22.2kJ 8.23kJ VD pump unit INV pump unit ACC pump unit Fig. 7 Electric energy consumption of ACC pump unit, INV pump unit and VD pump unit during one cycle E 1cycle =3.31[kJ] E 1cycle =3.31[kJ] E 1cycle =3.31[kJ] 4% 15% 11% 6% 85% 89% ACC pump unit INV pump unit VD pump unit Out put energy Loss of energy Fig. 8 Energy efficiency during one cycle of ACC pump unit, INV pump unit and VD pump unit The measured results are shown in Fig. 1. The pump rotation speed is almost constant. The measured flow rate begins to decrease suddenly at approximately 3 MPa and becomes zero at 3.8 MPa. Because the ACC pump unit uses the variable displacement vane pump, the displacement decreases, and the pump discharge changes when the discharge pressure becomes high. However, the pump is turned OFF by the pressure switch if the pressure is more than 3 MPa in the one-cycle test. It is turned ON if the pressure is less than 2.6 MPa. Therefore, it can be regarded as a fixed displacement pump in this operating condition. The pressure at which the flow rate becomes is called the full-cutoff pressure. The pressure where the flow rate begins to decrease is called the cutoff pressure. The power consumption and output power increase when the output pressure increases until the cutoff pressure, but they decrease with the reduction in flow rate after the cutoff pressure is exceeded. Since the drive range of the ACC pump unit is set to 2.6 3 MPa, the pump efficiency is approximately 53% in this range. 8

Throttle valve Flow meter M Fig. 9 Measurement circuit for ACC pump unit 16 1 Electric power[w] Output power[w] 14 12 1 8 6 4 2 Rotation speed Electric power Pump efficiency η 53% Output power Measured flow rate.5 1 1.5 2 2.5 3 3.5 4 Output pressure[mpa] Fig. 1 Static characteristics of ACC pump unit measured by keeping the pressure switch ON 9 8 7 6 5 4 3 2 1 Flow rate[l/min] Pump efficiency[%] 9

45 4 Rotation speed 1 9 Electricpower[W] Output power[w] 35 3 25 2 15 Measured flow rate Electric power Pump efficiency 8 7 6 5 4 3 Flow rate[l/min] Pump efficiency[%] 1 2 5 Output power.5 1 1.5 2 2.5 3 Output pressure[mpa] 1 Fig. 11 Static characteristics of INV pump unit 1 ] Electric power[w] Output power[w] Flow rate[.1l/min] η % 16 14 12 1 8 6 4 2 Consumption 26W Electric power Pump efficiency Output power Measured flow rate 5 1 15 2 25 3 35 4 45 1 9 8 7 6 5 4 3 2 1 Pump efficiency[%] Fig. 12 Static characteristics of INV pump unit 2 1

3.5.2 Static characteristics of INV pump unit To measure the static characteristics of the pump of the INV pump unit, the flow metering valve and the flow meter were attached to the INV pump unit and the characteristics were measured in the same way as the ACC pump unit shown in Fig. 9. The measured results of this pump s characteristics are shown in Fig. 11. In this figure, all the curves are perpendicular at 2.6 MPa. This is because the target pressure of the inverter controller is 2.6 MPa. The flow rate and pump rotation speed show similar changes at less than 2.6 MPa. They decrease gently until the target pressure. The electric power consumption, output power, and pump efficiency show similar changes. They increase gently when the output pressure increases. Since the data are concentrated at 2.6 MPa, the details are not understood. Therefore, in Fig. 12, the horizontal axis shows the pump rotation speed and the vertical axis shows the flow rate, power consumption, output power, and pump efficiency. At the experiment of one cycle, described in Section 3.2, the INV pump unit is driven at a low speed of approximately 4 rpm in 49 seconds, which is 79% of the one-cycle time. At this time, the work of the load side is on standby, as shown in Table 2. The actuator is in the stopping state. This rotation state of 4 rpm is a big problem in the INV pump unit. The electric power of approximately 26 W is always consumed and the efficiency is %. This is an example of useless power consumption. In other words, it is shown that electric power is wasted for 79% of the period during one cycle. 4. Conclusion The relation among the power consumption, pump output pressure and pump rotation speed in one cycle of the ACC pump unit, INV pump unit, and VD pump unit was clarified. From comparisons of the consumed electricity per one cycle of the INV pump unit, it was shown that the ACC pump reduced power consumption by approximately 63%. The energy efficiencies per one cycle were 11% in the VD pump unit, 15% in the INV pump unit and 4% in the ACC pump unit. In addition, the static characteristics of each hydraulic pump unit were measured. REFERENCES [1] Japan Accumulator, Product catalog NACCOL Accumulator (26) (in Japanese) [2] The Japan Fluid Power System Society, The world of oil hydraulic drive (23) (in Japanese) [3] The Japan Hydraulics and Pneumatics Society, Hydraulic and Pneumatics, New edition, Ohm-sha (1989) (in Japanese) [4] Fujikoshi hydraulics research group, New oil hydraulics wishing to know, basic edition, Japan Machinist (1993) (in Japanese) 11