PS1800 Centrifugal Pumping Systems



Similar documents
The conditions below apply to the curves shown on the following pages.

CRK A-W-A-BUBV

Installation Instructions for Solar Pumps USER MANUAL FOR SPS, SPC, SPSC SPQB, SPGJ SERIES SOLAR PUMPS AND PUMP CONTROLLERS

Cable Plug acc. to DIN EN , Form A

CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page - CONTENTS 100

Multistage high-pressure multistage centrifugal pumps

CRN A-F-G-E-HQQE 3x400D 50 HZ

Series description: Wilo-Drain TC 40

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

2CP. Twin-impeller pumps PERFORMANCE RANGE INSTALLATION AND USE APPLICATION LIMITS OPTIONALS AVAILABLE ON REQUEST CONSTRUCTION AND SAFETY STANDARDS

SANITARY & WASTE WATER PUMPING SYSTEMS. Now you can install kitchen, bathroom, laundry and commercial facilities almost anywhere.

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

WATER pressure. Issue 3 / Clear water pumps for domestic and commercial applications

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Conlift1, Conlift2, Conlift2 ph+

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Thyristor-controlled power supplies and battery chargers

Digital inductive conductivity transmitter

4" SUBMERSIBLE PUMPS

BB800 Off-Grid Solar System

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Valve Proving System VPS 504 Series S06 (120 VAC) Series S05 (24 VDC)

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water supply systems 50/60 Hz

INTRODUCTION WARNING S!!! VOC SHOULD BE BETWEEN MUST NOT EXCEED 96 VOC USE DC CIRCUIT BREAKER/ISOLATOR BETWEEN SOLAR PANELS & CONTROLLER

Heating, air-conditioning, cooling

Electric Flow Boiler

HYDRUS ULTRASONIC METER

SunMaxx Solar Filling Station Operating Instructions

KESSEL KTP 500 Submersible Pump with lateral and vertical outlet connection Order Numbers 28710, 28810, 28850

Fire Pump Plan Review March 2010

Operators manual Basic water heater

Ministry of New and Renewable Energy. Jawaharlal Nehru National Solar Mission SOLAR PHOTOVOLTAIC WATER PUMPING SYSTEMS ( )

CADB and CADT-D / DI / DC Series

LC/LCD ranges level controllers

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Condensing unit type EPSILON-ECHOS LE Technical information manual

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

How To Use A Corona Mdi 110

PRO-CLEAN. Technical Description. Specifications. Space-saving design with minimum heat loss (melamine resin insulation)

HP switch LP switch Discharge thermo Comp. Surface thermo

ECOCIAT. Domestic hot water heat recovery unit

Refrigeration Compressed Air Dryer Buran Ultrapulse

Laing industrial pumps

1x90 TONS TENSIONERS TECHNICAL PROPOSAL. 1 X 90 Tons 30 m/min Tensioners TECHNICAL PROPOSAL JOB 08/ /02/2008 Basic proposal PP GM SB

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Product catalogue, pipe and sewer cleaning systems

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

HERZ-Thermal Actuators

FLOAT SWITCHES FLOW SWITCHES FOR LIQUIDS PRESSURE SWITCHES

is then retained absolutely without interruption.

Oil and Coolant Circulating Heating System. Model - OCSM

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Digital pressure gauge for industrial applications Model DG-10-S, Standard version Model DG-10-E, Enhanced version

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

Pressure Relief Valves SPV, SPVF

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Technical Specification. Generating Set with Waukesha engine burning natural gas

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Linear Luminaire with LED Series EXLUX 6402/2

Solenoid valves Type EVU

Freezers - Ultrafreezers. Platilab & Irilab Series

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

8146/5 Series Breaker Panelboards

Explosion-Proof Electric Unit Heaters

Operation manual and Spare parts list EL PUMP. November

Material test chamber with mechanical convection

Series description: Wilo-Star-Z

Series 8146/5-V37 and Series 8150/5-V37

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

FP2 Relay. The Best Relaytion

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

GRUNDFOS DATA BOOKLET. SQFlex. Renewable-energy-based water supply systems. 50/60 Hz

BlueSolar Pro Remote Panel For BlueSolar PWM-Pro charge controllers 12/24V 5, 10, 20, 30A Article number SCC

Wind Sensor W-RS485 with RS485 Interface

BASIS RANGE TMB SERIES

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Single-Phase AC Synchronous Generator

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

400W AUTOMATIC STAINLESS STEEL SUBMERSIBLE CLEAN WATER PUMP

SOLAR PUMPING SYSTEM

Max. Head (m) LVR V , Hz ~ 220 V Oval Flange G1. LVR V , Hz ~ 380 V Oval Flange G1

sealed close coupled pumps

EFC Frequency converters

V47 Series Temperature Actuated Modulating Water Valves

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

P/N: DEF-0613A. Diesel Exhaust Fluid (DEF) Pumps

Mounting instruction Read instructions carefully!

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

LECTURE 28 to 29 ACCUMULATORS FREQUENTLY ASKED QUESTIONS

Aerona Air Source Heat Pumps

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

The space saving solution.

Transcription:

PS1 Centrifugal Pumping Systems General Data and Sizing Tables The curve show the performance range of 4 models at 1Wp solar array - irradiation of 6kWh/m² on a tilted surface - ambient temperature 3 C Solar tracking will improve performance by aprox 4% in summer month s Application: - drinking water supply - livestock watering - pond management - irrigation - village water supply meter head 9 7 6 5 4 3 2 Solar Pumping System / Capacity Diagram 6kWh/m²/day, 1Wp solar array SJ1-25 SJ5-12 SJ-7 Pump SJ17-2 SJ12-4 SJ-7 SJ5-12 SJ1-25 Lift Range -15m /5 ft 5-15m / 5ft 15-3m / 3ft 3-65m / 215ft 7-9m / 3ft Curve is based on Irradiation 6kWh/m² day, tilted surface Pump ends: SJ-xx = centrifugal pump Motor: brushless DC, maintenance free, max water temp. 25 C (F) 3 C (9F)for systems below 12Wp solar array LORENTZ offers standard solar pump solutions up to 23m (76ft) head and special solutions up to 75m (25ft) head. Ask for charts SJ12-4 1 1 USG = 3,L 1 I mpg = 4,5L --> larger flow = SJ17-2 15 35 55 75 95 115 135 155 Ver. 24 m³/day Controller PS1 controlling of the pump system and monitoring of the operating states mounted at surface (no submerged electronic parts) two control inputs for well probe (dry running protection), float or pressure switches, remote control etc. automatic reset 2 minutes after well probe turns pump off protected against reverse polarity, overload and high temperature speed control, max. pump speed adjustable to reduce flow rate to approx. 3 % solar operation: integrated MPPT (Maximum Power Point Tracking) battery operation: low voltage disconnect and restart after battery has recovered max. efficiency 92 % (motor + controller) enclosure: IP 54 (sealed, weatherproof) Motor ECDRIVE 12 HR / C brushless DC motor no electronics inside motor water filled IP6, pressure balanced, max. submersion unlimited dynamic slide bearings, material: carbon/ceramic wetted material: stainless steel (AISI 316), POM, rubber, cable drinking water approved Pump End (PE) high life expectancy none-return valve dry running protection (optional) material: stainless steel (AISI 316) Errors excepted and possible alterations without prior notice

Direct operated PV-Pump System : Solar Pump System PS1 C-SJ1-25 C-SJ1-25 Calculation of system performance is based on: US GPD m³/day 26 - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 3 C - 13,3% Generator efficiency - 1% cable loss Head Metres /Ft. 65 6 55 5 45 4 35 3 25 24 22 2 1 16 14 12 1 7/23 /263 9/295 6 4 5 2 Wp 7 9 11 12 13 14 16 17 1 19 21 2 3 4 5 6 7 9 22 Irradiation on a tilted surface kwh/m²/day BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 2455 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Internet: www.lorentz.de Tel: +49 4193 754- Fax: +49 4193 754-29 File: Auslegungschart_LORENTZPUMP_C-SJ1-25.dwg Rev. Oct. 27

PS1 C-SJ1-25 (Item No. 1156 ) for Solar Operation (Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 2V DC) 3, 2,5 Average Values 7 m / 23 ft m / 263 ft 9 m / 295 ft 7 6 2, 5 flow rate [m³/h] 1,5 1, 4 3 flow rate [US gal/h] 2,5 1, 2 4 6 12 14 16 1 DC power [W] Dimensions [mm] Minimum Internal Diameter Pump Type Weight A B C D Emax BSP of Borehole SJ 1A-25 2 16 696 96 9 1 1/4" 4" (14mm) 16 kg System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included. Motor The LORENTZ submersible motor, type EC 12-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 1V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 3% to full LED indicate status, pump speed water level, overload etc. 6 to standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 2V. For Systems above 12Wp Solar array size min. 7 or panels have to be wired in series. www.lorentz.de Rel. 14

Direct operated PV-Pump System : Solar Pump System PS1 C-SJ5-12 C-SJ5-12 Calculation of system performance is based on: US GPD m³/day 13 5 - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 3 C - 1% cable loss 4/132 Head Metres /Ft. 1 1 9 7 6 5 4 3 45 4 35 3 25 2 15 1 5 5/165 6/197 7/23 Wp 7 9 11 12 13 14 16 17 1 19 21 22 2 3 4 5 6 7 Irradiation on a tilted surface kwh/m²/day 9 BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 2455 Henstedt-Ulzburg, Germany e-mail: Info@Lorentz.de Internet: www.lorentz.de Tel: +49 4193 754- Fax: +49 4193 754-29 File: Auslegungschart_LORENTZPUMP_C-SJ5-12.dwg Rev. Jul. 27

PS1 C-SJ5-12 (Item No. 1163) for Solar Operation (Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 2V DC) 6,5 6, 5,5 5, 4,5 System Performance Average Values 3 m / 1 ft 4 m / 131 ft 5 m / 164 ft 6 m / 197 ft 16 14 12 flow rate [m³/h] 4, 3,5 3, 2,5 2, 1,5 7 m / 23 ft 6 4 flow rate [US gal/h] 1,,5 2, 2 4 6 12 14 16 1 DC Power [W] Dimensions [mm] Minimum Internal Diameter Pump Type Weight A B C D Emax BSP of Borehole SJ 5A-12 612 16 426 96 9 1 1/2" 4" (14mm) 13,5 kg System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included. Motor The LORENTZ submersible motor, type EC 12-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 1V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 3% to full LED indicate status, pump speed water level, overload etc. 6 to standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 2V. For Systems above 12Wp Solar array size min. 7 or panels have to be wired in series. www.lorentz.de Rel. 1114

Direct operated PV-Pump System : Solar Pump System PS1 C-SJ-7 C-SJ-7 Calculation of system performance is based on: US GPD m³/day 13 12 3 11 - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 3 C - 1% cable loss Head Metres /Ft. 1/33 15/49.5 25 5 1 9 7 6 5 4 3 2 1 2/66 25/2.5 3/9 Wp 7 9 11 12 13 14 16 17 1 19 21 22 2 3 4 5 6 7 Irradiation on a tilted surface 9 kwh/m²/day BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 2455 Henstedt-Ulzburg, Germany Tel: +49 4193 754- Fax: +49 4193 754-29 File: Auslegungschart_LORENTZPUMP_C-SJ-7.dwg Rev. Aug. 27 Internet: www.lorentz.de

PS1 C-SJ-7 (Item No. 1169) for Solar Operation (Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 2V DC) 14 Average Values 1 m / 33 ft 35 12 15 m / 49 ft 2 m / 66 ft 3 1 25 m / 2 ft 3 m / 9 ft 25 flow rate [m³/h] 6 flow rate [US gal/h] 4 2 5 2 4 6 12 14 16 1 DC power [W] Dimensions [mm] Minimum Internal Diameter Pump Type Weight A B C D Emax BSP of Borehole SJ A-7 65 16 415 96 9 2" 4" (14mm) 13,5 kg System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included. Motor The LORENTZ submersible motor, type EC 12-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 1V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 3% to full LED indicate status, pump speed water level, overload etc. 6 to standard 12V modules can be connected in series. e.g. nom. Voltage 72 to 96V, max system Voltage Umax= 2V. For Systems above 12Wp Solar array size min. 7 or panels have to be wired in series. www.lorentz.de Rel. 72

Direct operated PV-Pump System : Solar Pump System PS1 C-SJ12-4 C-SJ12-4 Calculation of system performance is based on: US GPD m³/day 5 45 4 35 2 1 16 14 - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 3 C - 1% cable loss Head Metres /Ft. 7.5/25 1/33 12.5/41 15/49.5 3 25 5 12 1 6 4 2 Wp 7 9 11 12 13 14 16 17 1 19 21 22 2 3 4 5 6 7 Irradiation on a tilted surface kwh/m²/day BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 2455 Henstedt-Ulzburg, Germany Internet: www.lorentz.de Tel: +49 4193 754- Fax: +49 4193 754-29 File: Auslegungschart_LORENTZPUMP_C-SJ12-4.dwg Rev. Aug. 27 9

PS1 C-SJ12-4 (Item No. 1217 ) for Solar Operation (Solar generator: Nominal voltage 72 to 96 V DC, open circuit voltage max. 2V DC) 22 2 1 16 Average Values 7,5m / 25 ft 1 m / 33 ft 12,5 m / 41 ft 15 m / 49 ft 55 5 45 4 flow rate [m³/h] 14 12 1 2 m / 66 ft 35 3 25 flow rate [US gal/h] 6 4 2 5 2 4 6 12 14 16 1 DC power [W] Dimensions [mm] Minimum Internal Diameter Pump Type Weight A B C D Emax BSP of Borehole SJ 12A-4 666 16 4 96 9 2" 4" (14mm) 13 kg System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) Or the other way: By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included. Motor The LORENTZ submersible motor, type EC 12-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for submergence. No electronics are inside the motor and the entire motor is water filled. Data: Voltage: 3 X 1V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 3% to full LED indicate status, pump speed water level, overload etc. 6 to standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 2V www.lorentz.de Rel. 723

Direct operated PV-Pump System : Solar Pump System PS1 C-SJ17-2 C-SJ17-2 US GPD m³/day 45 4 22 Calculation of system performance is based on: - non tracked PV-generator, (see ETATRACK for increasing performance) - 11h standard solar day - ambient average temperature of 3 C - 13,3% Generator efficiency - 1% cable loss Head Metres /Ft. 55 7.5/25 5 2 1 16 1/33 12.5/41 15/49 35 14 3 25 12 1 6 4 5 2 Wp 7 9 11 12 13 14 16 17 1 19 21 2 3 4 5 6 7 9 22 Irradiation on a tilted surface kwh/m²/day BERNT LORENTZ GmbH & Co.KG, Heidekoppel 16, 2455 Henstedt-Ulzburg, Germany Internet: www.lorentz.de Tel: +49 4193 754- Fax: +49 4193 754-29 File: Auslegungschart_LORENTZPUMP_C-SJ17-2.dwg Rev. Aug. 27

PS1 C-SJ17-2 (Item No. 116 ) for Solar Operation (Solar generator: Nominal voltage 96 V DC, open circuit voltage max. 2V DC) 24 22 Average Values 7,5m / 25 ft 1 m / 33 ft 6 2 12,5 m / 41 ft 55 1 16 15 m / 49 ft 5 45 4 flow rate [m³/h] 14 12 1 35 3 25 flow rate [US gal/h] 6 4 2 5 2 4 6 12 14 16 1 DC power [W] Pump Type Dimensions [mm] A B C D Emax BSP SJ 17-2 57 16 392 9 12 2 1/2" 5" (13mm) 15,5 kg Motor System Performance An irradiation value and the required head in meters are given for a certain solar pumping system. By connecting the point for the power output in Wp of the solar array with an irradiation value, move vertical upwards to the intersection with the required head curve, then horizontal to the left to find the daily quantity of water that can be pumped ( m³/day) The LORENTZ submersible motor, type EC 12-C is a 2 pole synchronous brushless DC motor. Slide ring bearing and ceramic trust bearings are water lubricated. The motor raw earth magnets are hermetically sealed in stainless steel and encapsulated in synthetic resin. The motor is pressure compensated and there are no practical depth limitations for Or the other way: submergence. No electronics are inside the motor and the entire motor is water filled. By starting from the daily required water amount horizontally to the intersection of the required head, then vertically down to the intersection with the expected solar irradiation, then horizontally to the left to find the required output of the solar array. From the above curves, the maximum quantity of water in m³/h for a given solar array size in Wp and head in meters / ft can be found. Add at least 25% to the DC power to account for dirt, heat and other losses of the solar array. Pump Centrifugal multistage direct coupled on a LORENTZ brushless submersible motor. The pump is made from stainless steel with water lubricated rubber bearings. A non return valve is included. Minimum Internal Diameter of Borehole Data: Voltage: 3 X 1V electronically commutated Power: 1,6kW / 2,2HP Efficiency: 92% max Controller Mounted at surface, Well probe and float switch terminals MPPT ( max. power point tracking) Overload, temperature and reverse polarity protected Pump Speed control from 3% to full LED indicate status, pump speed water level, overload etc. 6 to standard 12V modules can be connected in series. E.g. nom. Voltage 72 to 96V, max system Voltage Umax= 2V Systems above 12Wp require panels wired in series for nom 96V Weight www.lorentz.de Rel. 121

Tank Height Well to Basin Trans. Pipe Diameter Cable Length Trans. Pipeline Length Riser Pipe Diameter Static Level Drawdown Pump Intake Depth Well Diameter Depth of Well