Installation guide H-5500-8554-03-A HSI hardwired system interface
2008-2011 Renishaw plc. All rights reserved. This document may not be copied or reproduced in whole or in part, or transferred to any other media or language, by any means, without the prior written permission of Renishaw plc. The publication of material within this document does not imply freedom from the patent rights of Renishaw plc. Renishaw part no: H-5500-8554-03-A First issued: November 2008 Revised: March 2010 September 2011
Contents i Contents Before you begin... 1.1 Before you begin....1.1 Disclaimer...1.1 Trademarks...1.1 Warranty....1.1 Changes to equipment....1.1 CNC machines....1.1 Care of the interface....1.1 Patents....1.2 EC declaration of conformity....1.3 WEEE directive....1.3 FCC information to the user (USA only)....1.3 Safety...1.4 HSI basics... 2.1 Introduction....2.1 HSI components....2.2 Rengage probe connector (3-way)... 2.3 Standard probe connector (3-way)....2.3 Controller connector (12-way)... 2.3 'ERROR' LED.... 2.3 'STATUS' LED.... 2.3 'PROBE TYPE' LED.... 2.3 Remote device....2.3 Solid-state relay (SSR).... 2.4 Probe inhibit function....2.5 12 V - 30 V M-code connected directly to the HSI....2.5
HSI installation guide 0 V M-code connected directly to the HSI...2.5 M-code driven relay contact...2.6 M-code driven open collector...2.6 Contents ii HSI dimensions...2.7 HSI specification...2.8 System installation... 3.1 Installing the HSI...3.1 Typical HSI installation...3.1 Mounting the HSI to a DIN rail...3.2 Connecting the HSI to a Rengage probe and the CNC controller...3.3 Connecting the HSI to a standard probe and the CNC controller...3.4 Parts list... 4.1
Before you begin 1.1 Before you begin Disclaimer RENISHAW HAS MADE CONSIDERABLE EFFORTS TO ENSURE THE CONTENT OF THIS DOCUMENT IS CORRECT AT THE DATE OF PUBLICATION BUT MAKES NO WARRANTIES OR REPRESENTATIONS REGARDING THE CONTENT. RENISHAW EXCLUDES LIABILITY, HOWSOEVER ARISING, FOR ANY INACCURACIES IN THIS DOCUMENT. Trademarks Changes to equipment Renishaw reserves the right to change equipment specifications without notice. CNC machines CNC machine tools must always be operated by fully trained personnel in accordance with the manufacturer's instructions. Care of the interface Keep system components clean. RENISHAW and the probe emblem used in the RENISHAW logo are registered trademarks of Renishaw plc in the UK and other countries. apply innovation and of Renishaw plc. are trademarks All other brand names and product names used in this document are trade names, service marks, trademarks, or registered trademarks of their respective owners. Warranty Equipment requiring attention under warranty must be returned to your equipment supplier. No claims will be considered where Renishaw equipment has been misused, or where repairs or adjustments have been attempted by unauthorised persons. Prior consent must be obtained in instances where Renishaw equipment is to be substituted or omitted. Failure to comply with this requirement will invalidate the warranty.
HSI installation guide Before you begin 1.2 Patents Features of the HSI hardwired system interface and related products, are subject of one or more of the following patents and/or patent applications: EP 0695926 US 5,669,151
EC declaration of conformity C Renishaw plc declares that the HSI interface complies with the applicable standards and regulations. Contact Renishaw plc at www.renishaw.com/hsi for the full EC declaration of conformity. WEEE directive FCC information to the user (USA only) FCC Section 15.19 This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. Before you begin 1.3 The use of this symbol on Renishaw products and/or accompanying documentation indicates that the product should not be mixed with general household waste upon disposal. It is the responsibility of the end user to dispose of this product at a designated collection point for waste electrical and electronic equipment (WEEE) to enable reuse or recycling. Correct disposal of this product will help to save valuable resources and prevent potential negative effects on the environment. For more information, please contact your local waste disposal service or Renishaw distributor. FCC Section 15.21 The user is cautioned that any changes or modifications not expressly approved by Renishaw plc, or authorised representative could void the user s authority to operate the equipment. FCC Section 15.105 This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case you will be required to correct the interference at your own expense.
HSI installation guide Before you begin 1.4 Safety Information to the machine supplier/ installer It is the machine supplier's responsibility to ensure that the user is made aware of any hazards involved in operation, including those mentioned in Renishaw product literature, and to ensure that adequate guards and safety interlocks are provided. Under certain circumstances, the probe signal may falsely indicate a probe seated condition. Do not rely on probe signals to halt the movement of the machine. Information to the equipment installer All Renishaw equipment is designed to comply with the relevant EEC and FCC regulatory requirements. It is the responsibility of the equipment installer to ensure that the following guidelines are adhered to, in order for the product to function in accordance with these regulations: any interface MUST be installed in a position away from any potential sources of electrical noise, i.e. power transformers, servo drives etc; all 0V/ground connections should be connected to the machine 'star point' (the 'star point' is a single point return for all equipment ground and screen cables). This is very important and failure to adhere to this can cause a potential difference between grounds; all screens must be connected as outlined in the user instructions; cables must not be routed alongside high current sources, i.e. motor power supply cables etc, or be near high speed data lines; cable lengths should always be kept to a minimum.
HSI basics 2.1 Introduction CNC machine tools, or grinding machines using Rengage or standard probes for workpiece inspection, require an interface unit to convert the signals from the probe into voltage-free solid state relay (SSR) outputs for transmission to the CNC machine controller. The maximum SSR output operating current is 50 ma. Typically installed within the CNC machine controller cabinet, and located away from sources of interference such as transformers and motor controls, the HSI can draw its power from the machine's nominal 12 Vdc to 30 Vdc supply. Where such a supply is not available, the HSI can be powered using any 12 Vdc to 30 Vdc (minimum 0.5 A) power supply. The supply is protected by a 140 ma self-resetting fuse (its nominal current, when connected to an inspection probe, is either 40 ma@12 V or 23 ma@24 V). To reset the fuse, remove the power then identify and rectify the cause of the fault.
HSI installation guide HSI components HSI basics 2.2 The following components are housed within the front face of the HSI (as shown in the figure below): Rengage probe connector block (3 way); Standard probe connector block (3 way); Control connector block (12 way); 'ERROR' LED; 'STATUS' LED; 'PROBE TYPE' LED. Standard probe connector block (3 way) Controller connector block (12-way) Rengage probe connector block (3 way) 'ERROR' LED 'STATUS' LED 'PROBE TYPE' LED
Rengage probe connector (3-way) The Rengage probe connector is three pin and is designed to connect to a Renishaw Rengage probe. Standard probe connector (3-way) The standard probe connector is three pin and is designed to connect to Renishaw standard probes. Controller connector (12-way) The controller connector is 12 pin and is designed to connect the HSI to the CNC machine controller and appropriate power supply as follows: Terminals 1-3 Used to connect the inhibit function. For more information about the inhibit function, please refer to page 2.5. Terminals 4 and 5 If the HSI is installed where it cannot be easily seen, an output is provided so that a remote device (such as an LED or buzzer (not supplied)) can be connected to the HSI and positioned near to the machine operator. This is an open drain pull-up output at a nominal 10 ma. Terminals 6-8 These are the SSR probe trigger outputs: terminal 6 is normally open (N/O); terminal 7 is the common connection; terminal 8 is normally closed (N/C). The current output from any of these terminals is limited to 60 ma. Terminal 9 Used to connect the inhibit functions to 12 V - 30 V. It is fused at 100 ma. Terminals 10-12 These are used to supply power to the interface. The supply is fused at 140 ma. 'ERROR' LED The 'ERROR' LED flashes red to indicate that an error condition has occurred. This happens when too much current is supplied to the probe or to the SSR output. 'STATUS' LED The 'STATUS' LED displays: a constant green when the probe is seated; a constant red when the probe is triggered or no probe is connected. If the LED is unlit then there is no power supply to the HSI. 'PROBE TYPE' LED The 'PROBE TYPE' LED displays: a constant green when the interface is connected to a Rengage probe; a constant orange when the interface is connected to a standard probe or when no probe is connected; a flashing red when a probe inhibit function is active. If the LED is unlit then there is no power supply to the HSI. Remote device The remote device circuit provides: a closed output to indicate that the probe is seated (maximum current is 10 ma); an open output to indicate that the probe is triggered, that no probe is connected or that the power is off. HSI basics 2.3
HSI installation guide Solid-state relay (SSR) The SSR relay is configured as follows: HSI basics 2.4 Normally closed (N/C) or Normally open (N/O) Maximum current is ±50 ma. Maximum voltage is 30 V. NOTE: Change of state debounce time is 25 ms ±5 ms. Debounce time is the time delay between the HSI responding to a probe trigger and the point at which the probe can be used again. SSR OUTPUT OPTIONS Stylus contact bounce PROBE STATUS Trigger point Reseat Move clear At rest Deflected At rest Status N/C Closed Open Status N/O Closed Open
Probe inhibit function The inhibit function is used to switch off the Rengage probe and is activated by an M-code. It is recommended that the Rengage probe is switched off using the inhibit function whenever it is not in use, and only switched on immediately before it is required. This will ensure that the Rengage probe is initialised just before measurement commences to ensure optimum performance. When the Rengage probe is switched on, it will take a minimum of 0.4 seconds before it is ready to measure and must remain stationary during this period. The standard probe may also be inhibited using this function, if required. When the probe is inhibited the status output is forced into the non-triggered (seated) state, irrespective of actual probe status. There are several alternative methods of selecting the inhibit function, each of which is listed below: HSI basics 2.5 12 V - 30 V M-code connected directly to the HSI When using this method, it is recommended that the HSI is connected as shown in the following diagram. Alternatively pin 2 (INHIBIT RETURN) may be linked to pin 1 (0 V) on the HSI 12-way connector, rather than to the 0 V circuit within the machine's CNC controller. An M-code is used to activate the inhibit function. The M-code must supply a constant voltage of between 12 V and 30 V to pin 3 (INHIBIT) on the HSI 12-way connector. To deactivate the inhibit function, the 12 V to 30 V supply must be removed from pin 3 (INHIBIT) of the HSI 12-way connector. CNC CONTROLLER HSI CONTROL CONNECTIONS 1 0 V 0 V 12 V to 30 V M-code 2 INHIBIT RETURN 3 INHIBIT 0 V M-code connected directly to the HSI When using this method, it is recommended that the HSI is connected as shown in the following diagram. Alternatively, pin 3 (INHIBIT) may be linked to pin 9 (12-30 V OUT (FUSED 100mA)) on the 12-way connector, rather than to the 12 V to 30 V circuit within the machine's CNC controller. An M-code is used to activate the inhibit function. The M-code must supply a constant 0 V to pin 2 (INHIBIT RETURN) on the HSI 12-way connector. To deactivate the inhibit function, a constant voltage of 12 V to 30 V must be applied to pin 2 (INHIBIT RETURN) on the HSI 12-way connector. CNC CONTROLLER 0 V M-code 12 V to 30 V HSI CONTROL CONNECTIONS 2 INHIBIT RETURN 3 INHIBIT 9 12-30 V OUT (FUSED 100 ma)
HSI installation guide M-code driven relay contact HSI basics 2.6 When using this method, it is recommended that the HSI is connected as shown in the following diagram. Shorting together pin 1 (0 V) and pin 2 (INHIBIT RETURN) of the HSI 12-way connector (less than 100 ohms) will force the output into a seated state, irrespective of actual probe status, and remove power from the probe. Breaking contact between pin 1 and pin 2 (greater than 50 K ohms) will remove the inhibit function. HSI CONTROL CONNECTIONS M-code driven 1 0 V 2 INHIBIT RETURN Relay contact 3 INHIBIT 9 12-30 V (FUSED 100 ma) M-code driven open collector When using this method, it is recommended that the HSI is connected as shown in the following diagram. An M-code is used to activate the inhibit function. HSI CONTROL CONNECTIONS M-code driven 1 0 V 2 INHIBIT RETURN Open collector 3 INHIBIT 9 12-30 V (FUSED 100 ma)
HSI dimensions 98 (3.86) 134 (5.28) HSI basics 2.7 34.6 (1.36) Dimensions given in mm (in)
HSI installation guide HSI specification HSI basics 2.8 Principal application Dimensions Supply voltage Supply current Output signal Mounting Input/output protection Diagnostic LEDs The HSI processes signals from Rengage probes or standard probes and converts them into voltage-free SSR output, which is then transmitted to the CNC machine controller. Width: Height: Depth: 11 Vdc to 30 Vdc 40 ma @ 12 V, 23 ma @ 24 V 134 mm (5.28 in) 34.6 mm (1.36 in) 98 mm (3.86 in) Voltage free solid-state (SSR) output, configurable normally open or normally closed. DIN rail. Alternative mounting using screws. SSR output is protected by an electric circuit which limits the current to 60 ma. Power input is protected by a 140 ma resettable fuse. Error, status and probe type. Connection provided for remote device (LED or buzzer). Environment Storage temperature -25 C to +70 C (-13 F to +158 F) Operating temperature +5 C to +55 C (+41 F to +131 F)
System installation 3.1 Installing the HSI Typical HSI installation HSI interface Cable Rengage probe Cable CNC machine control Stylus Standard probe Optional power supply unit Workpiece NOTE: Only one probe can be connected at a time. Rengage probe compatible with the HSI MP250 Standard probes compatible with the HSI LP2 MP11 MP15 TS27R TS34 TS20 RP3 NOTE: The connection between the probe socket and the HSI interface must be screened and connected to ground at the interface.
HSI installation guide Mounting the HSI to a DIN rail System installation 3.2 34.6 (1.36) Dimensions given in mm (in) 134 (5.28) 98 (3.86) Standard DIN rail mounting M4 (x2) Alternative mounting
Connecting the HSI to a Rengage probe and the CNC controller For further information on Rengage probes, compatible with HSI, please refer to page 3.1. Probe holder fixed socket for Rengage probe Inner spring pin, Blue Outer spring pin, Green Green/Yellow HSI Rengage probe connector (3-way) 1 Probe input 0 V 2 Probe input 5 V 3 Screen Controller connector (12-way) System installation 3.3 CNC CONTROLLER Connect either pin 6 or pin 8, but do not connect both wires Probe input I/O supply skip input Controller protective earth (also referred to as PE starpoint or earthplate) Screen 0 Vdc 12-30 Vdc Probe inhibit function. Refer to page 2.5 for connection information. 1 0 V 2 Inhibit return 3 Inhibit 4 External LED 0 V 5 External LED 10 V 6 N/O* 7 Common 8 N/C** 10 Screen 11 Supply 0 V 12 Supply 12-30 V Status output SSR 9 12-30 V out (fused 100 ma) Power input Controller reference ground Status *Normally open (N/O) **Normally closed (N/C) Probe triggered Closed Open Probe seated Open Closed NOTE: When the SSR output is connected as normally open (N/O), the Rengage probe will remain in the non-triggered (seated) state if the power supply is interrupted or if the probe is damaged.
HSI installation guide System installation 3.4 Connecting the HSI to a standard probe and the CNC controller For further information on standard probes compatible with HSI, please refer to page 3.1. Inner spring pin Outer spring pin HSI Standard probe connector (3-way) 1 Probe input + 2 Probe input - 3 Screen Probe holder fixed socket for standard probe Controller connector (12-way) CNC CONTROLLER Connect either pin 6 or pin 8, but do not connect both wires Probe input I/O supply skip input Controller protective earth (also referred to as PE starpoint or earthplate) Screen 0 Vdc 12-30 Vdc Probe inhibit function. Refer to page 2.5 for connection information. 1 0 V 2 Inhibit return 3 Inhibit 4 External LED 0 V 5 External LED 10 V 6 N/O* 7 Common 8 N/C** 10 Screen 11 Supply 0 V 12 Supply 12-30 V Status output SSR 9 12-30 V out (fused 100 ma) Power input Controller reference ground Status *Normally open (N/O) **Normally closed (N/C) Probe triggered Closed Open Probe seated Open Closed NOTE: When the SSR output is connected as normally open (N/O), the standard probe will remain in the non-triggered (seated) state if the power supply is interrupted or if the probe is damaged.
Parts list 4.1 Interface Type Part number Description A-5500-1000 Terminal block P-CN25-0008 3-way terminal block. Terminal block P-CN47-0032 12-way terminal block. HSI probe system interface with DIN rail mounting and three terminal blocks, quick-start guide and packaging. Publications. These can be downloaded from our web site at www.renishaw.com MP250 HSI A-5500-8500 A-5500-8550 Quick start guide: for rapid setup of the MP250 probe, includes CD with installation guides. Quick start guide: for rapid setup of the HSI interface, includes CD with installation guides. MP11 H-2000-5007 Installation and user's guide: MP11. TS20 H-2000-5010 Installation and user's guide: TS20. TS27R H-2000-5018 Installation and user's guide: TS27R. LP2 H-2000-5021 Installation and user's guide: LP2. RP3 H-2000-5187 Installation and user's guide: RP3. TS34 H-2197-8500 Installation and user's guide: TS34.
HSI installation guide Parts list 4.2 This page left intentionally blank
Renishaw plc New Mills, Wotton-under-Edge, Gloucestershire, GL12 8JR United Kingdom T +44 (0)1453 524524 F +44 (0)1453 524901 E uk@renishaw.com www.renishaw.com For worldwide contact details, please visit our main website at www.renishaw.com/contact *H-5500-8554-03* 2008-2011 Renishaw plc Issued September 2011 Part no. H-5500-8554-03-A