Acoustical proprieties of light brick walls and its effects on flanking transmission



Similar documents
Lightweight Partition Design for Residential and Commercial Buildings

Acoustic performance of dwellings and specifics for lightweight constructions Professor Eddy Gerretsen

Tools for building acoustics design and experimental performances

VIPAC ENGINEERS & SCIENTISTS

PAGE 2. Figure 1: Difference between PWL ins and SPL 1m

ENVIRONMENTAL INFORMATION APR 1200 products are made from glass mineral wool, one of the most environmentally friendly insulants available.

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

The Role of Acoustics in Curtain Wall Design:

Building Design for Advanced Technology Instruments Sensitive to Acoustical Noise

EVERYTHING YOU WANTED TO KNOW ABOUT SOUND BUT WERE AFRAID TO HEAR.

Rockwool Flexi Insulation Application Guide

Acoustic Terms, Definitions and General Information

Section 4.3. Separating Floors. Timber frame floor with I-Beams. Upgrading existing timber floor with new ceiling. Timber frame floor with

ASTM E 90: Laboratory Measurement of Airborne Sound Transmission of Building Partitions and Elements

Statistical Energy Analysis software

Leeds Metropolitan University - Design and Build of new Acoustic Laboratory Suite

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

Sound Attenuation INTRODUCTION

Airborne Sound Insulation

A COMPUTATIONAL METHOD FOR ANALYSIS AND DESIGN OF ACOUSTIC ABSORBERS AND LOW FREQUENCY TRANSMISSION LOSS

LIGHTWEIGHT SCREEDS MADE OF CONCRETE AND RECYCLED POLYMERS: ACOUSTIC, THERMAL, MECHANICAL AND CHEMICAL CHARACTERIZATION

Controlling the Transmission of Impact Sound through Floors

ROOM ACOUSTICS DESIGN. Room Acoustics Design Intent: Appropriate Articulation

Fluid structure interaction of a vibrating circular plate in a bounded fluid volume: simulation and experiment

ACOUSTIC PERFORMANCES OF AN HEMIANECHOIC ROOM FOR ELECTROMAGNETIC COMPATIBILITY TESTS

INTER-NOISE DECEMBER 2006 HONOLULU, HAWAII, USA

ONLINE VERSION. The Building Regulations 2010 The Building (Approved Inspectors etc) Regulations 2010 ONLINE VERSION

Acoustic. Publication date June

Relationship between Sound Pressure and Sound Power Levels

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

An Experimental Study of the Sound Insulation Performance and Sound Defect Using Sound Intensity According to the Composition of Balcony Windows

E R0 ACOUSTICAL PERFORMANCE TEST REPORT ASTM E90. Rendered to: TREX COMPANY, LLC. Series/Model: Trex Seclusion

Acoustic Porous Materials and Their Characterisation

Free vibration of CLT plates

Mass Loaded Vinyl A review of the performance and cost in acoustical applications

3.0 Exhaust Muffler Design Principles. 3.1 Basic Concepts

! n. Problems and Solutions Section 1.5 (1.66 through 1.74)

Module 3.7. Thermal bridging

Practice Test SHM with Answers

Dubai Municipality Standard DMS 1: Part 5: 2004

Acoustic analysis by computer simulation for building restoration

Optimal Design of an Enclosure for a Portable Generator

P. D Antonio. RPG Diffusor Systems, Inc. Contact: pdantonio@rpginc.com

DEVELOPMENT AND APPLICATIONS OF TUNED/HYBRID MASS DAMPERS USING MULTI-STAGE RUBBER BEARINGS FOR VIBRATION CONTROL OF STRUCTURES

BNAM 2008 BERGEN BYBANE NOISE REDUCTION BY TRACK DESIGN. Reykjavik, august Arild Brekke, Brekke & Strand akustikk as, Norway

Understanding BS EN 771-3: Aggregate concrete masonry units

Schindler 3300 / Schindler 5300 Information on noise and vibration.

THE ACOUSTIC DESIGN OF THE NEW DRAMA HOUSE FOR THE ROYAL THEATRE IN COPENHAGEN

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR1 Teutonic Outswing Vinyl Entrance Door

TOP 10 NOISE CONTROL TECHNIQUES

SOUND TRANSMISSION CLASS TEST REPORT Series/Model: T-DR2 Teutonic Outswing Vinyl Entrance Door

Wardle Storeys. Reducing Rain Noise on Profiled Metal Roofing Systems Using DEDPAN DS2020 RDV

Fluid-Structure Acoustic Analysis with Bidirectional Coupling and Sound Transmission

Sound Power Measurement

A simple method to compute aircraft noise inside dwellings

Energy and Buildings

Office acoustics. How to effectively design the room acoustics of offices. AN INFORMATION BROCHURE OF

European Technical Approval ETA 13/0526

ProRox Slabs (formerly known as RW slabs)

CHAPTER 4 ACOUSTIC DESIGN OF LIGHTWEIGHT TIMBER FRAME CONSTRUCTIONS

Color logos Reverse logos Acoustics Black only logos

THE DEVELOPMENT OF DESIGN METHODS FOR REINFORCED AND UNREINFORCED MASONRY BASEMENT WALLS J.J. ROBERTS

RANDOM VIBRATION AN OVERVIEW by Barry Controls, Hopkinton, MA

CASE STUDY. Sarakasi Theatre Nairobi, Kenya Room Acoustical Measurements and Modelling. Africa Room Acoustics DIRAC and ODEON

Sound absorption and acoustic surface impedance

STANDARD DEVIATIONS IN FIELD MEASUREMENTS OF IMPACT SOUND INSULATION. Mikko Kylliäinen

Acoustical Design for Concert Hall in the Science and Art Centre of Xiamen University

Annex of the certificate (Page 1/6) Accreditation Scope

STUDY OF DAM-RESERVOIR DYNAMIC INTERACTION USING VIBRATION TESTS ON A PHYSICAL MODEL

Characterization of acoustics in open offices - four case studies

Development and optimization of a hybrid passive/active liner for flow duct applications

Built to Last. Built for Beauty. Good. Solid. Logix. TM

Shielding Effectiveness Test Method. Harbour s LL, SB, and SS Coaxial Cables. Designs for Improved Shielding Effectiveness

ROCKWOOL Rigid, Semi-rigid and Flexible Slabs are high quality resin bonded slabs that can be used for thermal, acoustic and fire insulation.

If stepping is required, step at 180mm as seen in this picture.

Prediction of Transmission Loss using an improved SEA Method

Direct and Reflected: Understanding the Truth with Y-S 3

The Acoustical Properties of Wool Carpet

Welcome Contents Back 1

NVH TECHNOLOGY IN THE BMW 1 SERIES

Noise Control Solutions For Standby Power Generators

Minimizing noise levels so future engineers can focus Classroom Acoustic Technical Reference Guide

Building envelope and heat capacity: re-discovering the thermal mass for winter energy saving

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

ASTM E 90 SOUND TRANSMISSION LOSS TEST REPORT. Rendered to: MGM INDUSTRIES SERIES/MODEL: TYPE: Single Hung Window

ANSI/ASHRAE Standard Building Thermal Envelope and Fabric Load Tests

Effects of Different Diffuser Types on the Diffusivity in Reverberation Chambers

Infrared Spectroscopy: Theory

Active noise control in practice: transformer station

Investigation of sound insulation for a Supply Air Window field measurements and occupant response

ACOUSTIC CAVITIES DESIGN PROCEDURES

Acoustic Design Guide

SPEECH INTELLIGIBILITY and Fire Alarm Voice Communication Systems

FIREPROOF Panels Trimoterm

Test Report. Nr dated Sound Absorption Coefficient in the Reverberation Room. Lammengatan 2 SE Lammhult Sweden

Manual Analysis Software AFD 1201

Vibration measurements on future supports of mirrors M3 and M4 (ver. 1.0)

REHABILITATION OF THE FIGUEIRA DA FOZ BRIDGE

Transcription:

Acoustical proprieties of light brick walls and its effects on flanking transmission G. Semprini a and L. Barbaresi b a University, DIENCA Dept. Facoltà di Ingegneria, Viale Risorgimento, 136 Bologna, Italy b DIENCA - Univ. of Bologna, Viale Risorgimento, 136 Bologna, Italy giovanni.semprini@mail.ing.unibo.it 79

Light brick walls 8- cm thick are typical structures frequently used in Italian building constructions as a internal partitions between dwellings and as internal layer of double façade walls. Due to low surface mass and rigid connection to other horizontal and vertical structures, light brick walls are often responsible of high flanking transmission. The simplest acoustic modelling of this structure for the evaluation of sound transmission in buildings, is the approach proposed by the EN 14 standards, where the brick wall can be considered as a homogeneous structure and required main acoustic parameters are the sound reduction index and the vibration reduction index Kij. The aim of this paper is to analyse results of physical and acoustical properties (like sound reduction index, structural reverberation time, longitudinal wave velocity) of a typical 8 cm thick brick wall measured in laboratory testing facility. 1 Introduction Hollow brick walls are widely used in Italian buildings as a simple partition between rooms or as internal layer of an external multi-layer wall. In the first case the structure is plastered on both sides, while in the latter is one-side plastered. Acoustic parameters for both configurations are expected widely different due to important effect of the cement plaster layer on both surface mass and internal damping of the wall. The effect of this kind of structure as a lateral wall connected to an heavy partition has also been tested in laboratory test facility, in order to evaluated the effect of T junction flanking transmission. Experimental data have then been compared with calculation method of the EN 14-1 [1] standard. Figure : wall A test configuration. Afterwards the wall (named B) has been plastered on the other side, giving a wall surface mass of 97 kg/m. 3 Experimental results The laboratory apparent sound reduction index, R W, have been calculated according to EN ISO 1-3 [] e EN 717-1 [3], giving the value of R W =33 db for the test wall A and R W =37 db for the test wall B. Frequency results of the sound reduction index for both configuration is showed in figure 3. Sound reduction index -R [db] 5 0 Sound reduction index - R Test specimen 15 63 80 0 15 1 00 315 0 0 6 800 00 1 10 000 0 31 00 00 Wall "A" with singol cement plastering Wall "B" with double cement plastering The light hollow brick wall was built in a laboratory test facility. Block dimensions are 8x5x5 cm; inside these bricks there are holes of 4.5x.7x5 cm dimensions. The first configuration of the wall (named wall A ) has been built connecting horizontally and vertically bricks with cement mortar and finished on only one side with cement plastering (1700 kg/m 3 ) of 1.5 cm thick. The wall surface mass, measured on a 1 m specimen is 7 kg/m. Time [s] 5,5 5,0 4,5 4,0 3,5 3,0,5,0 Figure 3: Sound reduction index R of both test walls Structural reverberation time - Ts, lab 1,5 1,0 0,5 0,0 63 80 0 15 1 00 315 0 0 6 800 00 1 10 000 0 31 00 00 Wall "A" with singol cement plastering Wall "B" with double cement plastering Figure 1: Hollow brick Figure 4: Structural reverberation time T s,lab of both test walls. 80

The mean structural reverberation time (obtained from 1 accelerometer position for 3 impact hammer positions) measured by the impulsive technique in accordance with Schroeder method [4] is shown in figure 4. The structural reverberation time at high frequencies (0 31 Hz) of wall A and B presents peaks due to resonance modes of the holes brick cavity. In fact using the formula determining natural mode for 3-D systems: c nx ny nz fn lx ly l = + + (1) z and inserting as input data the real dimensions of holes bricks, we obtain the first resonance frequency at f n =338 Hz. Total loss factor are: η tot = 0.013 for test wall A and η tot =0.01 for test wall B. Longitudinal wave speed are very different: c L = 314 m/s for test wall A e c L = 0 m/s for test wall B. Ff Fd Df 4 Flanking transmission effects A following test was performed in order to evaluated the structural flanking transmission of the light brick wall strong coupled with an heavy partition characterized by a double brick wall (8x5x cm), with a rock-wool panel (80 kg/m3) inside the 5 cm cavity. The total surface mass of the partition is 90 kg/m. The sound reduction index of the measured partition in the same laboratory, with flanking transmission suppressed, is R W = 5 (-1, -4) db, according to EN ISO 1-3 e EN 717-1. Thereafter a single brick wall (8 cm) plastered on one side was built perpendicularly to the partition, forming an T junction, in order to determine the vibration reduction index K ij, according to standard ISO 848:006 [5]. Both acoustical and vibration measurements were performed in order to compare different methods. The test analysed configuration was a T junction between the partition i and the 8 cm lateral wall j that was built from the source and the receiving room (figure 5). This is a typical situation that occurs in Italian buildings where the external façade is realised with a double leaf brick wall where the internal side is the light element rigidly connected to internal partitions of the building. In this way the light continuous wall (element j ) causes an high flanking sound transmission. Table 1 shows the results of the measured sound transmission index R W of the single partition without flanking transmission, and the measured apparent sound transmission index R W of the partition with the flanking transmission ( T junction). Flanking transmission effects was considerable, and the reduction of the sound transmission index was of 8 db. This results depends also on particular configuration of the lateral walls that are heavy connected only on the floor and on the partition, while the other two sides are disconnected from the laboratory test specimen. Figure 5 T junction (second test configuration) and sound transmission paths ij between two rooms Testing wall Junction R w (R w ) 5 + lateral wall (8) T (44) Table 1 (Apparent) Weighted Sound reduction index R W (R W ) 4.1 Vibration reduction index Kij and calculation of apparent sound reduction The estimation of apparent sound reduction according to CEN model specified in EN 14-1 gives the single number rating involved in the sound transmission between two rooms, with the following expression: R n RFf n R Df n R = lg + + + F= 1 f = 1 F= 1 RFd () where: R,w is the weighted sound reduction index for direct transmission, in decibels ; R Ff,w is the weighted flanking sound reduction index for the transmission path Ff, in decibels ; R Df,w is the weighted flanking sound reduction index for the transmission path Df, in decibels ; R Fd,w is the weighted flanking sound reduction index for the transmission path Fd, in decibels ; n is the number of flanking elements in a room; normally n= 4, but it can be smaller or larger depending on the design and construction of the considered situation. 81

From apparent sound reduction (for every frequency band) is possible to determine the sound reduction index R W of the test wall according to EN ISO 717-1 method. We can obtain the terms of the expression () by the following formulas: R = R + Δ R + ΔR (3) s,situ D,situ D,situ Ri,situ + R j,situ S Rij = + Δ Ri + ΔR j + Kij + log (4) l0 lij where R i,situ ed R j,situ are sound reduction index of element i and j in the actual field situation; ΔR i e ΔR j are sound reduction index improvement by additional layers for element i and j ; K ij is vibration reduction index for each transmission path ij over a junction; S is area of separating element; l ij is common coupling length between element i and element j; l 0 is reference length (= 1 m). In this case the ΔR terms are null, while lateral transmissions path considered are only Df, Fd and Ff. The relations for vibration reduction index for each transmission path ij over a junction has been calculated as function of the surface masses (m e m ) making the junction with the following expression cited in EN 14-1: m' M = log (5) m' and with relationships included in annex E in the same standard. In this case the two expressions used for T junction are: and for Df and Fd paths and for Ff path. ij K ij = 5 7, + 5 7, * M (6) K = 5 7, + 14,1* M + 5 7, * M (7) The value of the index of reduction of the vibration K ij for a determined configuration of joint among two structures perpendicularly connected, can be nevertheless evaluated experimentally according to the methodology reported in the ISO 848 standard on the base of the following expression: K ij lij = Dv,ij + log (8) a a Dv,ij + Dv, ji where Dv,ij = (9) D v,ij and D v,jis are the differences of the average levels of vibration velocity in the two structures, respectively in the direction ij and in that ji [db]. l ij is the length of the junction under test: 3.00 [m]; i j a i and a j are, respectively, the lengths of equivalent absorption of the elements i and j [m]. The terms a i and a j are calculated with the following expression:. π Si, j fref ai, j = () c0 Tsi, j f S i is the area of the element i,. [m ]; S j is the area of the element j, 11.5 [m ]; T s is the structural reverberation times [s]; c 0 is the speed of the sound in the air, 3 [m/s]; f is the current frequency [Hz]; f ref is the frequency of reference, 00 [Hz]. The average vibration velocity levels and the structural reverberation times have been evaluated by using impulsive sources (steel hammer 0 g). [6] [7] 4. Results Experimental results related to the weighted sound reduction index are compared with those obtained by the analytical model of the EN 14-1 standard (detailed method in frequency). As input data in the formulas (3) and (4) the weighted sound reduction index measured in the laboratory of the partition and the lateral walls have been used. The surface masses have been evaluated by a direct measure on a small test wall (1 m ). The K ij values have been evaluated by means of experimental measurements determined through the (8) and of calculation according to the ratio between the masses and to the type of joint according to the expressions (6) and (7). Testing wall K ij Ts,situ/ Ts,lab + wall (8) + wall (8) + wall (8) + wall (8) + wall (8) R w measured 44 EN 14 No 47 EN 14 Yes laboratory No 47 laboratory Yes 44 Table (Apparent) Weighted Sound reduction index R W (R W ) 8

5 Acoustics 08 Paris 65 Apparent sound reduction index - R' - Kij EN 14 Bibliography Apparent sound reduction index R' [db] 0 15 1 00 315 0 0 6 800 00 1 10 000 0 31 R' (laboratory) R' (Kij EN 14) R' (Kij EN 14 -Tsitu/Tlab) Figure 6: Comparison of apparent sound reduction [1] EN 14-1:00 Building acoustics - Estimation of acoustic performance of buildings from the performance of elements - Airborne sound insulation between rooms [] EN ISO 1-3:006 Acoustics. Measurement of sound insulation in buildings and of building elements. Laboratory measurements of airborne sound insulation of building elements. [3] EN ISO 717-1:1997 Acoustics. Rating of sound insulation in buildings and of buildings elements. Airborne sound insulation. Apparent sound reduction index R' [db] 70 65 5 0 Sound reduction index - Rsitu 0 15 1 00 315 0 0 6 800 00 1 10 000 0 31 R (separating element) R () (separating element) R (lateral element) R (FD) - R (DF) (lateral element) Figure 7: Comparison of apparent sound reduction in the actual field situation [4] Schroeder M. R., New method of measuring reverberation time, Journal of the Àcoustical Society of America, 1965,. 37, p.9 [5] ISO 848-1:006 Acoustics Laboratory measurement of the flanking transmission of airborne and impact sound between adjoining rooms. Part 1 Frame document [6] De Tricauld P., Impulsive techniques for the simplification of insulation measurements between dwellings, Applied Acoustics, 1975, 8, -56 [7] Craik R.J.M., The measurement of structure-borne sound transmission using impulsive sources, Applied Acoustics, 198, 15, 3-361 5 Conclusion Typical light brick wall analyzed in this paper present some interesting results especially for acoustical performance data necessary for calculation models for the evaluation of the sound insulation in real buildings. The sound reduction index, present a great dependency with the cement plaster (+4 db with the second size plastered). Structural reverberation time and longitudinal wave speed are also dependent on second plaster in a significant way. Comparison between calculated and measured apparent sound reduction index shows the great importance of the correction term T situ /T lab, and therefore the necessity to always measure in laboratory the structural reverberation time of the partition. 83