In recent years there has been remarkable progress



Similar documents
Implant therapy using osseointegrated implants has

Resistance to dislodgement of zirconia copings cemented onto titanium abutments of different heights

Retention of maxillary implant overdenture bars of different designs

Choosing Between Screw-Retained and Cement-Retained Implant Crowns

The inability to consistently achieve a passive fit with

Clinical and Laboratory Procedures for Fixed Margin Implant Abutments

The total occlusal convergence of the abutment of a partial fixed dental prosthesis: A definition and a clinical technique for its assessment

Survey of United States dental schools on cementation protocols for implant crown restorations

Osseointegrated implant connected with natural tooth using a semiprecision attachment: A clinical report

While the prosthetic rehabilitation of

THE INFLUENCE OF COMPRESSIVE CYCLIC LOADING ON THE RETENTION OF CAST CROWN COPINGS CEMENTED TO IMPLANT ABUTMENTS

Supervisors: Dr. Farhan Raza Khan

Contents. Cement retained restoration. Screw retained restoration. Overdenture retained restoration. TS Implant System. 70 ComOcta Gold Abutment

THE PROFILE PROSTHESIS: AN AESTHETIC FIXED IMPLANT- SUPPORTED RESTORATION FOR THE RESORBED MAXILLA

Retention of CAD/CAM All-Ceramic Crowns on Prefabricated Implant Abutments: An In Vitro Comparative Study of Luting Agents and Abutment Surface Area

Ideal treatment of the impaired

Full-Arch Fixed Screw-Retained PFM Implant Restoration

IMPLANT DENTISTRY EXAM BANK

THE EVOLUTION OF EXTERNAL AND INTERNAL IMPLANT/ABUTMENT CONNECTIONS

Screw versus Cement Retained Prosthesis: A Review Ritesh Modi 1, Rashmi Mittal 2, Shivani Kohli 3, Ankit Singh 4, Iram Sefa 5

A Review of Implant Abutments - Abutment Classification to Aid Prosthetic Selection

SCD Case Study. Treatment Considerations for Implant Rehabilitation

Dental Implant Restoration

Straumann. Time-tested

Removing fixed prostheses using the ATD automatic crown and bridge remover

Abutment fracture in a bridge supported by natural teeth and implants

Long-term success of osseointegrated implants

The rate of success of implants in the edentulous

Ridge Reconstruction for Implant Placement

Prosthetic treatment planning on the basis of scientific evidence.

Regular C/X Prosthetics. Prosthetics

Full Mouth Restoration with Screw-Retained Zirconia Bridges

All-on-4 treatment concept with NobelSpeedy Groovy

portion of the tooth such as 3/4 Crown, 7/8Crown.

Maximum Dislodging Forces of Implant Overdenture Stud Attachments

The preservation or reproduction of a natural

Managing a Case of Sensitive Abutment Situations through Use of a Fixed Movable Prosthesis A Clinical Report

Taking the Mystique out of Implant Dentistry. Dr. Michael Weinberg B.Sc., DDS, FICOI

The importance of uniform terminology and

Khaldoon G. Abu Afifeh, B.D.S, M. Sc in Prosthodontics

Implant Bar Overdenture Utilizing Locator Attachments

The Transition from Teeth to Implants and the Use of Post-ceramic Soldering

Treatment planning for the class 0, 1A, 1B dental arches

ATLANTIS ISUS the benchmark for CAD/CAM suprastructures. For all major implant systems

procedures & products NOBELESTHETICS including Procera

Attachments And Their Use In Removable Partial Denture Fabrication

Implant Replacement of the Maxillary Central Incisor Utilizing a Modified Ceramic Abutment (Thommen SPI ART) and Ceramic Restoration

CHAPTER 10 RESTS AND PREPARATIONS. 4. Serve as a reference point for evaluating the fit of the framework to the teeth.

Prosthetic Manual. Implant System. Contact Us: Smarter thinking. Simpler design. Phone: Fax:

Telescopic Denture A Treatment Modality for Minimizing the Conventional Removable Complete Denture Problems: A Case Report

Long-Term Outcome of Cemented Versus Screw-Retained Implant-Supported Partial Restorations

Ceramics on Implants Fixed Zirconium Dioxide-Based Restorations in the Rehabilitation of the Edentulous upper Jaw

Procedures & Products. NobelEsthetics

RESTORING STRAUMANN IMPLANTS WITH LOCATOR ABUTMENTS

screw-retained single crowns using custom-cast abutments

Leslie Laing Gibbard, BSc, BEd, MSc, PhD, DDS George Zarb, BChD, DDS, MS, MS, FRCD(C)

Flexible dentures an alternate for rigid dentures? Volume 1 Issue 1

2016 Buy Up Dental Care Plan Procedure List

Full Crown Module: Learner Level 1

BASIC INFORMATION ON THE STRAUMANN VARIOBASE ABUTMENT. Straumann Variobase Abutment

Dental Updates. Excerpted Article Why Implant Screws Loosen Part 1. Richard Erickson, MS, DDS

Contact: Steve Hurson VP, R & D Nobel Biocare Savi Ranch Pkwy Yorba Linda, CA (714) steve.hurson@nobelbiocare.

PROSTHETIC PROCEDURE. for HG IMPLANT SYSTEM

Implants for life? A critical review of implant-supported restorations

Implants in your Laboratory: Abutment Design

1- Fatigue-Resistance and Microleakage of CAD/CAM Ceramic and Composite Molar crowns

LEBENSLAUF Dent. Dr. ÖZGE ÖZTÜRK

ADA Insurance Codes for Laboratory Procedures:

Another Implant Option for Missing Teeth with Challenging Symmetry Patrick Gannon, DDS and Luke Kahng, CDT

education Although demographic factors and growing patient awareness of the benefits of dental implants

Accelerated Patient Rehabilitation

INTRODUCTION. most popular stud attachment available to the dental profession to increase the retention of implant complete

Dr. Abhinav Gupta M.D.S., Certificate D.G.O.I.( Implants) Assistant Professor(Prosthodontics) Dental College, A.M.U., Aligarh.

BICON DENTAL IMPLANTS

Replacement of the upper left central incisor with a Straumann Bone Level Implant and a Straumann Customized Ceramic Abutment

NARROW DIAMETER implant

IMPLANTS IN FOCUS. Endosseous dental implant restorations PLANNING FOR IMPLANT RESTORATIONS

Dr. Little received his doctorate degree in dentistry from UT Health at San Antonio Dental

PROSTHETICS. Crown and Bridge Restorations with the synocta Prosthetic System DENTAL IMPLANT SYSTEM

STEP-BY-STEP INSTRUCTIONS ON THE PROSTHETIC PROCEDURES. Straumann Anatomic IPS e.max Abutment

Retrospective study on the survival rate of IBS implant

IMPLANT DENTISTRY CLINICAL SYLLABUS

IMMEDIATE CUSTOM IMPLANT PROVISIONALIZATION: A PROSTHETIC TECHNIQUE

One Abutment - One Time

ATLANTIS abutments design guide CAD/CAM patient-specific abutments

Teeth in a Day for the Maxilla and Mandible: Case Report

STEP BY STEP INSTRUCTIONS ON TEMPORARY ABUTMENTS. Straumann Temporary Abutments, VITA CAD-Temp

PROSTHETICS. Crown and bridge restorations with the synocta prosthetic system.

ATLANTIS crown abutment. Patient-specific CAD/CAM abutments for single-tooth, screw-retained restorations

Choosing the right type of abutment

THE SINGLE-TOOTH IMPLANT TREATMENT FOR MAXILLARY CENTRAL INCISORS LOSS AFTER TRAUMA: CASE REPORTS

Ando A., Nakamura Y., Kanbara R., Kumano H., Miyata T., Masuda T., Ohno Y. and Tanaka Y.

Dental Implant Treatment after Improvement of Oral Environment by Orthodontic Therapy

Accurate Transfer of Peri-implant Soft Tissue Emergence Profile from the Provisional Crown to the Final Prosthesis Using an Emergence Profile Cast

Restorative Guidelines

Multi-unit abutment bar overdenture

ERA. Attachment Systems. A SNAP to Use and Maintain

Improving Esthetics with Sequential Treatment Planning and Implant-Retained Dentures

Restoring the Endodontically Treated Tooth:Post and Core Design and Material 根 管 治 療 後 牙 齒 的 修 復 :Post and Core 的 設 計 與 材 料

HEALTH SERVICES POLICY & PROCEDURE MANUAL. SUBJECT: Types of Dental Treatments Provided EFFECTIVE DATE: July 2014 SUPERCEDES DATE: January 2014

Transcription:

Cement Failure Loads of 4 Provisional Luting Agents Used for the Cementation of Implant-Supported Fixed Partial Dentures Konstantinos X. Michalakis, DDS 1 /Argiris L. Pissiotis, DMD, MS, PhD 2 / Hiroshi Hirayama, DDS, DMD, MS, FACP 3 The major disadvantage of cement-retained implant-supported fixed partial dentures (FPDs) is difficulty in retrievability. The retentive strengths of the provisional luting agents usually employed in these cases are therefore an important consideration. This study evaluated the cement failure loads of 4 provisional luting agents used for the cementation of FPDs supported by 2 implants or 4 implants. Nogenol luting agent exhibited the lowest retentive values in both types of FPD. ImProv proved to be the most retentive cement of all tested. Temp Bond NE and Temp Bond presented significantly different values (P <.05) for the 2-implant FPD, but not for the 4-implant model. On the basis of the study results, it may be concluded that Nogenol appears to be more appropriate for cementation of both 2- and 4-implant-supported FPDs when removal of the provisionally cemented superstructure is anticipated. (INT J ORAL MAXILLOFAC IMPLANTS 2000;15:545 549) Key words: dental cements, denture retention, implant-supported dental prosthesis In recent years there has been remarkable progress in the field of implant dentistry. However, many questions have arisen regarding the materials used and techniques followed in clinical practice. One of these questions is related to the method by which fixed partial dentures (FPDs) are connected to underlying implants: screw-retained or cemented? Screw-retained prostheses have the advantage of retrievability for reservicing, replacement, or salvaging of the restorations and implants necessitated by (1) need for periodic replacement of prosthodontic components, such as the intramobile elements of the IMZ System (Interpore International, Irvine, CA); (2) fracture of fastening screws; (3) fracture of abutments; (4) modification of the prosthesis after 1 PhD candidate, Department of Prosthodontics, School of Dentistry, Aristotles University of Thessaloniki, Greece. 2 Assistant Professor, Department of Prosthodontics, School of Dentistry, Aristotles University of Thessaloniki, Greece. 3 Associate Clinical Professor and Director of Graduate and Postgraduate Prosthodontics, Tufts University School of Dental Medicine, Boston, Massachusetts. Reprint requests: Dr Konstantinos X. Michalakis, 3, Greg. Palama str, Thessaloniki 546 22, Greece. Fax: +3031 272-228. loss of an implant; and (5) surgical reintervention. 1 Therefore, retrievability of implant prosthetic components is a significant safety factor. It should also be noted that removal of implant-supported FPDs is sometimes needed for better evaluation of oral hygiene. Peri-implant probing is also more accurate if the prosthesis is removed. However, screw-retained prostheses are also associated with non-passive superstructures, partially unretained restorations resulting from loosening or breakage of fastening screws, and rapid loading of the implant interface. 2 4 Cement-retained prostheses, on the other hand, allow for optimal esthetics and occlusion, 5 passive fit of superstructures, easier axial loading, use of traditional prosthetic techniques, fewer fractures of acrylic resin or porcelain, and fewer appointments. 6 It has also been advocated that the luting agent may act as a shock absorber. 7,8 The main disadvantage of cemented prostheses is their difficulty in retrievability. Although retrieval is needed less often nowadays, because of the dramatically increased survival rates for dental implants, the need for future removal of the FPD should not be overlooked. For this reason, provisional luting agents are widely used for the cementation of implant-supported restorations. The International Journal of Oral & Maxillofacial Implants 545

Fig 1 The 4 Brånemark implants embedded in the block of transparent resin, with the UCLA hex abutments on top. Fig 2 The 4-unit FPD. Previous researchers 9 12 have studied the tensile as well as the compressive strength of provisional luting agents and zinc phosphate cements for single-implant restorations. However, the single-unit implant restoration is usually not a problem. Passive fit of the superstructure is more important and more difficult to achieve using screw-retained prostheses in multiple-implant restorations. These situations would more likely make a clinician skeptical about the ease of retrievability of implant-supported FPDs. For this reason, it was decided to evaluate the retentive strengths of 4 provisional luting agents used to cement restorations supported by 2 or 4 implants 24 hours after cementation. MATERIALS AND METHODS Two blocks (4 8 2 cm) of autopolymerizing transparent resin were constructed. Two 3.75 15- mm Brånemark System implants (Nobel Biocare, Göteborg, Sweden) were placed in one of the blocks (block A). Four 3.75-mm Brånemark System implants were placed in the other block (block B). The implants were placed into the resin blocks after preparing the implant sites by means of a slowspeed handpiece mounted on a milling machine. This was done to assure that the implants were parallel to each other. The distance between the 2 implants in block A was 14 mm, which is approximately the distance between a maxillary first premolar and a maxillary first molar. The 4 implants in block B were placed in a straight line with 7 mm between each implant. Plastic UCLA hex abutment patterns (Lifecore Biomedical Inc, Chaska, MN) were sprued, invested, and cast in a high gold-palladium content alloy (Olympia, Jelenko, Armong, NY). Each fitted abutment casting was paired with an implant. Then each abutment was cut with a separating disc to a height of 5 mm. After the fastening screws were tightened, the screw access opening was filled with light-curing resin flush with the top of the abutment shoulder (Fig 1). Then a 2-unit FPD was waxed to fit the 2 UCLA abutments in block A, and a 4-unit FPD was waxed to fit the 4 UCLA abutments in block B in the same manner. To keep the cement space consistent, the plastic prefabricated waxing sleeves accompanying each abutment were used for fabrication of the FPD sleeves. A 3-mm-diameter cylindric plastic rod was used for connection of the sleeves (Fig 2). A wax loop was incorporated at the upper part of each FPD. Then the FPDs were sprued, invested, and cast using the same high gold-paladium alloy that was used for fabrication of the UCLA abutments (Fig 2). The provisional luting agents used for this study were: (1) ImProv (Steri-Oss, Yorba Linda, CA), (2) Nogenol (GC America Inc, Alsip, IL), (3) Temp Bond (Kerr Manufacturing Co, Romulus, MI), and (4) Temp Bond NE (Kerr Manufacturing Co). Each provisional luting agent was mixed according to manufacturer instructions, and a quantity of 0.01 ml, measured by means of an insulin syringe, was used for each unit of the FPD. The cement was applied to the internal aspect of the abutment sleeves, as evenly as possible, by the same operator. Then the FPDs were seated immediately with finger pressure, followed by a controlled axial load of 5 kg, which was applied for 10 minutes. The restorations were then stored in 100% humidity at 37 C for another 23 hours and 50 minutes. Excess cement was removed with a curette before testing. 546 Volume 15, Number 4, 2000

Fig 3 The Ametek AccuForce III tensile testing apparatus. Fig 4 The 4-unit FPD secured to the testing machine by means of 2 C-clamps. An Ametek mechanical testing instrument (Accuforce III, Ametek, Mansfield & Green Division, Paoli, PA) applied uniaxial tensile force at a crosshead speed of 1 mm per minute by means of a hook mounted on a 500-lb load cell (Fig 3). The hook of the testing machine exerted force to the loop of the FPD, while the resin blocks were secured on the instrument by the use of 2 C-clamps (Fig 4). After each tensile test, the FPDs and the resin blocks with the UCLA abutments were placed in a cement removal solution (L&R Manufacturing Co, Brussels, Belgium) in an ultrasonic unit for 15 minutes. The specimens were dried and visually inspected to ensure complete removal of the luting agent. Ten cementations were accomplished for each luting agent, giving a total of 40 readings each for the 2- and 4-unit FPDs. RESULTS The mean tensile forces required to pull the different FPD models from the UCLA abutments are presented in Table 1. Because a significant difference was noted by analysis of variance for both the 2-unit (F = 27.14120, P =.0005) and the 4-unit (F = 26.53324, P =.0005) FPDs, a Tukey HSD test (P <.05) was also performed in both cases (Table 2). Figures 5 and 6 show the mean cement failure loads and standard deviations for the 2- and 4-unit FPDs for each experimental group (n = 10). ImProv exhibited the highest mean retentive strength for both the 2- and 4-unit FPDs (24.60 kg and 43.67 kg, respectively). The retentive strength exhibited by ImProv for the 2-unit FPD was not significantly different from that exhibited by Temp Bond NE (P <.05). However, there was a significant difference between the values of these 2 cements when compared to those of Temp Bond and Nogenol. For the 4-unit FPD there was a significant difference between the retentive values of ImProv and the other luting agents. Temp Bond NE registered mean retentive strength values of 23.25 kg and 38.21 kg for the 2- and 4-unit FPDs, respectively. Temp Bond ranked third in strength, with mean retentive values of 15.99 kg and 37.52 kg for the 2- and 4-unit FPDs. A comparison of the retentive strength values of Temp Bond and Temp Bond NE revealed a significant difference for the 2-unit FPD but not for the 4-unit FPD. The lowest values for retentive strength were exhibited by Nogenol for both experimental situations (12.46 kg and 29.51 kg, respectively). These values were significantly different from those of all other luting agents for the 4- unit FPD. However, no significant difference was noted between the values of Nogenol and Temp Bond for the 2-unit FPD. DISCUSSION Implants have been used successfully for restorative treatment for more than 20 years. Currently, there are many options for prosthetic designs that differ from those proposed by Brånemark et al. 13 These options are related not only to the materials used, but also to the method of fixation of the restorations to the implants. Many clinicians suggest that cementation offers many advantages over screw retention. The only advantage of the latter method is the ease of retrievability. Thus, it is difficult to justify the use of screws for prosthesis retention, with the exception of situations involving limited abutment height. The International Journal of Oral & Maxillofacial Implants 547

Cemented implant-supported restorations have substantial advantages, as discussed earlier and reported in implant textbooks and scientific articles. Since the only major disadvantage of cemented implant-supported restorations appears to be the difficulty of retrievability, factors that influence the amount of retention are of interest. 14 16 These Table 1 Mean Cement Failure Loads (in kg) and Standard Deviations for the FPD Models Cement 2-unit model 4-unit model ImProv 24.60 ± 3.61 43.67 ± 3.74 Nogenol 12.46 ± 3.95 29.51 ± 4.12 Temp Bond NE 23.25 ± 3.39 38.21 ± 2.31 Temp Bond 15.99 ± 3.10 37.52 ± 3.87 Mean 19.08 ± 6.12 37.23 ± 6.17 include taper or parallelism, surface area and height, surface finish or roughness, and type of cement. Taper greatly influences the amount of retention provided in a cement-retained prosthesis. It has been stated that for tooth preparation, a 6-degree taper is ideal. 16,17 This is the reason why in the implant industry, most manufacturers machine their abutments to a 6-degree taper. It is evident that UCLA abutments offer more retention, because their walls are parallel thus the reason for the use of this type of abutment in this study. Results of the cement failure load test indicate the maximum retention that can be achieved for a 3.75-mm implant when the UCLA abutments have a height of 5 mm and have not been roughened or sandblasted. It is obvious that if the height of the abutments was greater or the surface was roughened, the test results would be different. Table 2 Results of Tukey Highly Significant Difference Test for Both FPD Models Model ImProv Nogenol Temp Bond NE Temp Bond 2-unit model ImProv.000159*.827211.000179* Nogenol.000159*.000159*.132294 Temp Bond NE.827211.000159*.000424* Temp Bond.000179*.132294.000424* 4-unit model ImProv.000159*.008532*.002699* Nogenol.000159*.000181*.000236* Temp Bond NE.008532*.000181*.972854 Temp Bond.002699*.000236*.972854 *Significant difference (P <.05). 35 60 Cement failure load (kg) 30 25 20 15 10 Cement failure load (kg) 50 40 30 20 5 10 0 ImProv Nogenol Temp Bond NE Cement Temp Bond 0 ImProv Nogenol Temp Bond NE Cement Temp Bond Fig 5 Mean cement failure loads and standard deviations for the 2-unit FPD. Fig 6 Mean cement failure loads and standard deviations for the 4-unit FPD. 548 Volume 15, Number 4, 2000

In this study, the type of cement was considered because, as has been stated by Breeding et al, 10 this is the deciding factor in retention, if retrievability of the implants or prosthesis is the issue. The definitive cements that are used in traditional prosthodontics are not recommended, since metal abutments do not decay and, as such, are not at risk of this complication. Another reason is that these cements are too strong to ever permit access to the implants. The purpose of this study was to determine cement failure loads of a 2-unit and a 4-unit FPD luted to 2 and 4 UCLA abutments, respectively, 24 hours postcementation, by testing the null hypothesis that cement failure loads are similar regardless of the provisional luting agent employed. Statistical analysis of the results indicates that the null hypothesis should be rejected. The choice of one provisional luting agent over another significantly affected the cement failure loads. In the present study, the ImProv provisional luting agent exhibited the highest tensile strength 24 hours postcementation for both the 2- and the 4- unit implant-supported FPDs, whereas Nogenol showed the lowest tensile strength. Temp Bond NE and Temp Bond ranked second and third, respectively. Since provisional luting agents differ from each other in tensile strength values, it is very important for the clinician to select those that exhibit the lowest retentive values. Further research is needed in this area to investigate 2 additional variables: (1) the effect of petroleum jelly on the retentive values of the cements tested, and (2) the effect of thermocycling specimens. However, the clinician should be aware that with proper selection and handling of provisional cements, implant-supported FPDs can be removed with a reverse action bridge remover or with pliers. CONCLUSIONS Within the limitations of this in vitro study it was concluded that: 1. Twenty-four hours postcementation, ImProv cement exhibited higher retentive strength values than Temp Bond NE, Temp Bond, and Nogenol for both the 2-unit and the 4-unit implant-supported FPDs. 2. Nogenol provisional luting agent seems to be more appropriate for the cementation of implantsupported FPDs, if retrievability is important. REFERENCES 1. Chiche GJ, Pinault A. Considerations for fabrication of implant-supported posterior restorations. Int J Prosthodont 1991;4(1):37 44. 2. Jemt T, Linden U, Lekholm U. Failures in 127 placed fixed partial prostheses supported by Brånemark implants. Int J Oral Maxillofac Implants 1992;7:40 44. 3. Zarb GA, Schmitt A. Longitudinal effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered. J Prosthet Dent 1990; 64:185 194. 4. Kallus T, Bessing C. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 4 years. Int J Oral Maxillofac Implants 1994; 9:169 178. 5. Hebel KS, Gajjar RC. Cement-retained versus screw - retained implant restorations: Achieving optimal occlusion and esthetics in implant dentistry. J Prosthet Dent 1997; 77(1):28 35. 6. Misch CE. Contemporary Implant Dentistry. St. Louis: Mosby-Year Book Inc, 1993:651 685. 7. Singer A, Serfaty V. Cement-retained implant-supported fixed partial dentures: A 6-month to 3-year follow-up. Int J Oral Maxillofac Implants 1996;11:645 649. 8. Guichet DL. Load transfer in screw- and cement-retained implant fixed partial denture design [abstract]. J Prosthet Dent 1994;72:631. 9. Breeding LC, Dixon DL, Bogacki MI, Tietge JD. Use of luting agents with an implant system: Part I. J Prosthet Dent 1992;68(5):737 741. 10. Dixon DL, Breeding LC, Lilly KR. Use of luting agents with an implant system: Part II. J Prosthet Dent 1992; 68(6):885 890. 11. Kent DK, Koka S, Froeschle ML. Retention of cemented implant-supported restorations. J Prosthodont 1997;6(3): 193 196. 12. Koka S, Ewoldsen NO, Dana CL. The effect of cementing agent and technique on the retention of a CeraOne gold cylinder. A pilot study. Implant Dent 1995;4:32 35. 13. Brånemark P-I, Zarb GA, Albrektsson T (eds). Tissue-Integrated Prostheses: Osseointegration in Clinical Dentistry. Chicago: Quintessence, 1986:241 282. 14. Jorgensen KD. The relationship between retention and convergence angle in cemented veneer crowns. Acta Odontol Scand 1955;13:35 40. 15. Gilboe DB, Teteruck WR. Fundamentals of extracoronal tooth preparation. Part I: Retention and resistance form. J Prosthet Dent 1974;32:651 656. 16. Shillingburg HT Jr, Jacobi R, Brackett SE. Fundamentals of Tooth Preparations for Cast Metal and Porcelain Restorations. Chicago: Quintessence, 1987:17 23. 17. Rosenstiel SF, Land MF, F ujimoto J. Contemporary F ixed Prosthodontics. St. Louis: Mosby, 1988:130. The International Journal of Oral & Maxillofacial Implants 549