SKAC222 (SQA Unit Code - DD38 04) Carry out basic glazing and carpentry repairs



Similar documents
Unit title: Carpentry and Joinery: Second Fixing (SCQF level 6)

ASTCCR2 - SQA Unit Code H Carry out and complete clean-room cleaning operations

Standard Door Specification

ISSUE 2. Installation Guide

SEMFWE232 SQA Unit Code H2BN 04 Cutting plate and sections using shearing machines

ABOUT US... With a continued investment in machinery, the company now produces the following:

PROOF ONLY. Police and Fire Service Home Security & Fire Safety Checklist. Student Accommodation Security Checklist

Approved Document Q: Security

anatomy of a window lintel architrave inner staff bead top rail lintel upper sash glazing bar meeting rails horn pane lower sash reveal

TRADITIONAL CASEMENT WINDOWS

ASTFFL2 - SQA Unit Code H54D 04 Assess and estimate work required to limit damage to structures post fire

Energy Efficient Windows

Window Installation Instructions

Chelsea Loft Bed WARNING:

Advice Note on Windows in Listed Buildings

Description of the Task/Activity: General door/window fitting/replacement. Start Date/Time: Site Address/ Location: Finish Date/Time:

Replacement Window Installation Guide Non-Impact & Impact Resistant Windows without Nailing Fin

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

Design and Access Statement for replacement of windows and doors at. Blacksmiths Cottage Sutton Road Mount Pleasant Derbyshire DE65 5DE

Product Management - Glass ALEXA PRODUCT PRESENTATION. Region SAARC Nitin Lloyd, Product Management. Chennai, FY 2013 / 2014

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

Installation Instructions Double-Hung, Single-Hung, Casement, Awning, Sliding, Picture & Shapes Non-Impact & Impact Resistant Nailing Fin Windows

Guidance on Replacement Windows in Listed Buildings and Conservation Areas

Check Your Home Security

SECURITY LATCH TM SIMPLE, SAFE & SECURE

SKACH11 Hair colour correction services

Window Repair & Replacement in Conservation Areas

REDI-EXIT COMMERCIAL FIRE DOOR AND EXTERIOR DOOR KITS INSTALLATION GUIDELINES

SFHCHS8 Insert and secure urethral catheters and monitor and respond to the effects of urethral catheterisation

Tested to BS 6375: Part 1: 1989 and achieved a weathertightness classification of 2000 Pa (Special)

Installation Instructions

Sash Window Specialist

Code of Practice for fire resisting metal doorsets

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

How to Measure for Exterior Shutters

COSVR404 Erect and dismantle plant (cranes and rigs)

Fire Doors Basic Guidance & Checklist

CDW Systems Ltd Contemporary Doors & Windows

The London Sash Window Company provided me with a truly professional service from beginning to end. I would highly recommend their services.

SCDHSC0032 Promote health, safety and security in the work setting

Installation instructions of the MIDI-Heki roof light with operating bar, with crank or electrical version

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

SKAD462 (SQA Unit Code - FG6J 04) Apply the principles of nutrition to support client goals as part of an exercise and physical activity programme

Fire-Rated Doors and Hardware. A Guide to Field Inspection

ASTFFL1 - SQA Unit Code H54C 04 Respond to requests for fire damage limitation work

Restoring Replacing Creating

to encourage high quality tropical vernacular Queensland architecture throughout the Shire;

Basement Window Installation Guide Hopper and Sliding

City of San Diego, CWP Guidelines

Working at Height. Procedure

Homeowner s Handbook

Can you design a frameless shower enclosure that doesn't leak?

Universal systems for frameless doors

pottery barn kids MADELINE BUNK BED

Fire-rated Aluminum Doors

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

CLAIM FORM APPENDIX. I. Photographs Identifying The Windows

IQ Level 3 Certificate in Principles of Glass Related Operations (QCF) Specification

MEANS OF EXIT / ESCAPE / EGRESS SELF INSPECTION CHECKLIST

Stylish energy-efficient windows and doors. for ideal homes.

The Role of Fire Doors. BWF-Certifire Fire Door and Doorset Scheme

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Manual on Door and Window Details for Residential Buildings. Volume-1. Govt. of India Central Public Works Department

STAIRCASES I DOORS I WINDOWS

A Complete Solution CREATING WALLS THAT DEFINE SPACE

Preparing a maintenance plan

BAKA Protect Series 2000 / Protect. The adjustable hinge system for timber entrance doors

Level 2 NVQ Diploma in Trowel Occupations (Construction) ( ) May 2014 Version 2.0

SFJPE1.3 Evaluate the effectiveness of the operational delivery business process

Total doorset solutions, architectural ironmongery, access control and washroom fittings

7. Installation. installation CAST-IN WINDOW SYSTEM 7.1. INSTALLATION OF WINDOW MAIN FRAME

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

Scope of works. Name Job# TBA -1. Project: Bathroom Renovation

Size & Range. for windows & doors. Company

Why buy Nimbus? Nimbus Why Buy?

SOMERSET LEADING WINDOW COMPANY

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

Guidance Note: Windows in Historic Buildings

WASHROOM UPGRADE SIR CHARLES TUPPER BUILDING 2250 RIVERSIDE DRIVE, OTTAWA, ON SIR CHARLES TUPPER BUILDING A0.0 COVER SHEET / DRAWING LIST

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

Relevant British, European and International standards

DOMESTIC WINDOW SECURITY

ATTACHMENT A STRUCTURAL INTERIOR DESIGN (SID) REQUIREMENTS

Make it Difficult for the burglar. Contents. Look at your home through a burglar s eyes: Alarms 4_5. Distraction burglary 6 _ 7.

Energy Company Obligation (ECO): Technical Monitoring Questions

The repair or replacement of timber sash and case windows

ASTFFL6 - SQA Unit Code H54H 04 Prepare for flood damage emergencies

PANEL CONCEPTS LLLP.

Installer Training and Certification Overview

Portable Ladder Safety

SECTION COLD-FORMED METAL DECK FRAMING Elevations Steel Deck Framing by Trex

Droveway ARCHITECTURAL SERVICES. Disability Access Audit. Sample Gospel Hall. 22 September For

Installation Guide. Bath and Wall Surrounds SERIES B

Reachout Lock Replacement for Andersen 2-Panel and 4-Panel 400 Series Frenchwood Gliding, 200 Series Narroline, and Perma-Shield Gliding Patio Doors

Not all windows are the same...

Transcription:

Overview This unit is about carrying out basic repairs to windows, doors and carrying out other carpentry repairs. Manual and power operated tools are used. The purpose of the repair could be to: 1. repair single glazing 2. repair double sealed units 3. fit door furniture (such as mortise locks, rim locks, hinges, handles, door closers, casement stays and fasteners) 4. maintain wooden fixtures 5. maintain wooden fittings The unit is divided into three parts. The first part describes the four things you have to do. These are: 1. use step ladders to gain access beyond hand reach height 1. replace broken glazing 2. fit door and window furniture 3. carry out basic carpentry maintenance The second part describes the knowledge and understanding you must have. The third part gives examples and explanations of some words we use in the unit. This unit is for people who carry out basic glazing and carpentry repairs as part of their normal work duties. SKAOSC222 (SQA Unit Code - DD38 04) 1

Performance criteria You must be able to: You must be able to: You must be able to: Use step ladders to gain access beyond hand reach height P1 check that the step ladders are safe for use P2 label unsafe step ladders clearly to prevent them being used P3 report unsafe step ladders to the right person promptly P4 erect and secure step ladders correctly P5 position step ladders on a firm and level base P6 meet the relevant health and safety requirements when working with and from step ladders P7 return the step ladders to the right place after use and store them properly Replace broken glazing P8 use approved safe working practices throughout the repair P9 make the opening safe until the broken glazing is replaced P10 replace broken glazing at the earliest opportunity P11 get the right type and size of replacement glazing P12 remove, without damage to the frame, all broken glass, old bedding and fixings P13 fix replacement glazing, beddings and fixings correctly P14 leave the glazing, the frame and the immediate surrounding area clean and free from waste materials P15 dispose of all broken glass and other waste materials safely P16 report any broken glazing that you are not competent to replace to the relevant person Fit door and window furniture P17 use approved safe working practices throughout the repair P18 choose door and window furniture that is the most suitable in terms of appearance and use P19 prepare door and window surfaces correctly for the fitting of furniture P20 you fit the furniture correctly P21 you check that the newly fitted furniture is working properly You must be able to: Carry out basic carpentry maintenance P22 use approved safe working practices throughout maintenance P23 correctly identify the items that need maintenance and the maintenance that they need P24 choose the hand tools and equipment that are most appropriate for the maintenance that is needed P25 make sure that your maintenance does not have an adverse effect on SKAOSC222 (SQA Unit Code - DD38 04) 2

P26 P27 the finished appearance of the items check that the items function properly following maintenance report any carpentry maintenance requirements that you are not competent to undertake to the relevant person SKAOSC222 (SQA Unit Code - DD38 04) 3

Knowledge and understanding You need to know and Yu need to know and You need to know and You need to know and For the whole unit K1 why it is important to use approved safe working practices throughout, what these practices are and the possible consequences of failing to use them Use step ladders to gain access beyond hand reach height K2 the safety checks that you must carry out on step ladders before use and what might happen if you do not carry these out K3 what might happen if you do not label unsafe step ladders K4 why it is important to report unsafe step ladders promptly and who you should report these to K5 examples of work and working heights for which step ladders are suitable and unsuitable K6 how to erect and secure step ladders correctly and what might happen if you do not do this K7 why step ladders must be positioned on a firm and level base K8 what are the relevant health and safety requirements that you must meet when working with and from step ladders K9 the reasons why step ladders must be returned to the right place after use, and where this is Replace broken glazing K10 why it is important to make the opening safe until broken glazing can be replaced, and how this should be done K11 why it is important to replace broken glazing at the earliest opportunity K12 where, or from whom you can get details of the type and size of glazing required, and the possible consequences of getting incorrect glazing K13 methods of removing, without damage to the frame, broken glass, old bedding and fixings from different types of frames K14 how to fix replacement glazing, bedding and fixings correctly into the different types of frames repairs K15 why it is important to leave the work area clean and free from waste materials K16 how and where to dispose of broken glass and other waste materials safely Fit door and window furniture K17 the factors that need to be considered when choosing door and window furniture that is the most suitable in terms of appearance and use (e.g in keeping with the door/window style; security needs.) K18 how door and window surfaces should be prepared for the fitting of each SKAOSC222 (SQA Unit Code - DD38 04) 4

of the stated items of door and window furniture K19 how to fit the stated items of door and window furniture correctly K20 why it is important to check that newly fitted furniture is working properly You need to know and Carry out basic carpentry maintenance K21 the hand tools and equipment that are appropriate for the different types of maintenance K22 how to carry out maintenance in a way that does not have an adverse effect on the finished appearance of the items K23 why it is important to check that items are functioning properly following maintenance SKAOSC222 (SQA Unit Code - DD38 04) 5

Additional Information Scope/range related to performance criteria 1. glazing 1.1. single 1.2. double sealed unit 2. frames 2.1. timber 2.2. metal 2.3. UPVC Glazing must be undertaken so that the thickness of internal bedding material is approximately 3mm and is even in the rebated when glazing is complete. Internal or external bedding material must not encroach into sight lines. 3. furniture 3.1. Mortise locks 3.2. Rim locks 3.3. Hinges 3.4. Handles 3.5. Door closers 3.6. Casement stays and fasteners Door and window furniture must be fixed so that: 1. they are positioned to within 4mm 2. they are fixed parallel/level to within 1mm 3. any recessed parts have no gaps exceeding 1mm 4. maintenance 4.1. easing 4.2. adjusting 4.3. splicing 4.4. fixing to walls 5. hand tools and equipment 5.1. manually operated hand tools and equipment 5.2. power operated hand tools and equipment In relation to splicing and fixing to walls the following tolerances are to be applied: 1. spliced items are to have no gaps exceeding 1mm 2. items fixed to walls are to be level to +3mm/metre SKAOSC222 (SQA Unit Code - DD38 04) 6

Glossary Beddings For example, putty Door and window furniture Mortise locks, rim locks, hinges, handles door closers or casement stays and fasteners Frames Made of timber, metal or UPVC Glazing Single and double glazing Waste materials For example, broken glass, used putty Links to other NOS This unit links closely with SKAOSC13 and SKAOSC221 SKAOSC222 (SQA Unit Code - DD38 04) 7

Developed by SkillsActive Version number 1 Date approved June 2009 Indicative review date Validity Status Originating organisation Original URN Relevant occupations Suite Key words June 2014 Current Original SkillsActive SA44NC222 Associate Professionals and Technical Occupations; Leisure, travel and tourism; Sport, leisure and recreation; Sports and Fitness Occupations Operational Services carry, out, basic, glazing, carpentry, repairs SKAOSC222 (SQA Unit Code - DD38 04) 8