The Warm Edge for insulating glass



Similar documents
Linear thermal transmittance of the assembly of the glazing and the frame in windows

Choosing better, more energy efficient windows. A homeowners guide

WOODEN WINDOWS CATALOGUE.

SL30-ISO PROFILE SYSTEM

Energy Efficient Windows

because it s personal

Dow Corning PROPRIETARY. Dow Corning. A Thermal Modelling Comparison of Typical Curtain Wall Systems

Sealing & Bonding Sika solutions for Window Installation

FederalDemocratic RepublicofEthiopia

Garage Sectional Doors

Unbeatable energy efficient glass curtain wall system

WINDOWS THE HEAT TRANSFER COEFFICIENT IN DIFFERENT TYPES OF WINDOWS

Energy efficient windows, doors and conservatories. Make a better choice

Glass partitions SFB 3074

Advice Note on Windows in Listed Buildings

Specification Guide. SmartSash. Fenestration Solutions for Public Sector & Commercial Applications ARCHITECTURAL. D11 +D13:X725 CI/SfB (31.4)+(31.

AND MEMBRANES ROOFING UNDERLAYS.

Profiles in stock Standard catalogue. Discover the possibilities with aluminium profiles from Sapa

Selecting Energy-Efficient Windows

Multi-layer Insulation Blanket for Roofs

Confort 26. Sliding Systems. Sapa Building System

Rockwool Flexi Insulation Application Guide

What is Solar Control?

Double Glazing Glass. Energy Saving Solutions. Harris Silicones & Glass (Pvt.) Ltd.

Fire Resistant Systems

Not all windows are the same...

TOPLIGHTS. NOTE: 2.4m high sliding doors are only available in certain configurations and sizes.

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

RPV - RP - RA air handling units

ENERGY EFFICIENT WINDOWS & DOORS A GUIDE TO THERMAL PERFORMANCE. Building Solutions Automotive Industry

Windows are one of the most important components of a

The answer. Cost-Benefit Ratio of different construction depths. Comparison of U f -values. profine GmbH Kömmerling Kunststoffe

Q-Lon foam weatherseal: for PVC, timber and aluminium applications THE WORLDS BEST WEATHERSEAL

Light Architecture. Colors Sweden. Light

building applications copper - redefined

Evaluation of inside surface condensation in double glazing window system with insulation spacer: A case study of residential complex

CE66. Windows for new and existing housing

High-speed spiral doors for deep-freeze applications. TK Series

Product Data Sheet ROCKPANEL Rockclad

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

In the Fall 2002 issue of HHE News I examined

Prefabricated building PVC vertical sliding window

Advice to consumer Reference 50.1 May Condensation. Some causes, some advice.

Confort 160. Sliding Systems. Sapa Building System

DOMUS & ALDUS THE WINDOW CONCEPT WITH A STUNNINGLY MODERN APPEARANCE

ponto trasso DESCRIPTION CHARACTERISTICS - FLOODLIGHTS ADVANTAGES VERSIONS

High-efficient gas boiler CompactGas

Removing Moisture within Large Double Glazed Windows

new Twine & Pinch A tribute to the traditional column radiator Eyecatchers From design to art 2009 Ex

PYROSWISS VETROFLAM CONTRAFLAM

UniPlate. Solar Collectors SOLAR SYSTEMS.

Requirements on secondary insulating glass sealants

Installation Detailed installation instructions are provided which should be strictly followed.

Self-Cleaning. The forecast will always be clear and cool. Pilkington Activ Range Self-cleaning and solar control glass for conservatories.

Selecting Energy Efficient New Windows in Florida

Side Hinged Doors GSW 40-L

ENERGY LABELLING OF GLAZINGS AND WINDOWS IN DENMARK: CALCULATED AND MEASURED VALUES

Rockwool Cladding Roll

Plaisance 24. Sliding Systems. Sapa Building System

FACADE DESIGN & EXECUTION

BYG DTU. Thermal properties of window frame Type 1 Sheet: 1. Type: Side, top and bottom profile. Source file: Format: dwg/dxf bmp

Insider Tips for Purchasing Replacement Windows

FIXIT.CH. Aerogel Insulating Plaster System. Handling Guidelines. Easy to use. Mineral based W/mK BAUSTOFFE MIT SYSTEM

Clinic Washer-Disinfectors. Washer-Disinfector Line

AUSTENITIC STAINLESS DAMASCENE STEEL

Energy efficiency - Always compare whole window performance and not just the individual components.

SERIES 3000/4000 DOUBLE SLIDER AND DOUBLE HUNG WINDOWS. Craftsmanship. Style. Performance.

ENERGY SMARTS: ENERGY EFFICIENT WINDOWS

Energy efficiency of windows in historic buildings

Why compromise when you can have Windows for Life?

A few good reasons to have a conservatory. The conservatory structure

EcoRange W I N D O W S & D O O R S

The Garador Range Price List

WALLS Three common wall types are described below, with their insulation solutions.

Selecting Energy Efficient New Windows in California

iku windows the intelligent self cleaning window AUTOMATIC system

PYRAN PYRANOVA. Special-purpose glass products for fire resistant glazing

Pilkington Activ self-cleaning glass. The clear choice for your conservatory.

Brochure EX

Thermal Breakage Prediction

Improving thermal insulation of concrete sandwich panel buildings

SCHOTT PYRANOVA Planline System

Only by learning from the past, we can meet the demands of the future. Rhepanol fk

Adhesives. Sticking to what we know best! Bonding and cleaning Window and door construction PVC, aluminium and wood. 33/08 made by Weiss

Plaisance 50. Windows and doors. Sapa Building System

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

Unique customised facade solutions

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

SEAC's new generation of glazing packer 3-4. General/Colour codes 5. Definition 6. Glazing-in process 7. Glazing Procedure 8-9

The BASA Guide to the ISO Classification of Sealants for Building Construction

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Life Cycle Assessment of zero- emission façade construction

BER Assessors Dwellings Technical Bulletin

Suitable for large-area facades, commercial properties, conservatories, extensions plus detached, semi-detached and terraced houses.

Technical data sheet PVC Bi-fold doors

Mechanical insulation to increase building efficiency. Saving money, energy and the planet.

CHOOSE THE RIGHT DOOR FOR YOUR HOME

Concepts. Products. Service. Lindner Plus Organisation

WATERPROOF PHOTOVOLTAIC SYSTEM

Transcription:

The Warm Edge for insulating glass

1. 3. SGGSWISSPACER 2. 4. The best product on the market by quite an edge Energy saving Lower heating costs through better insulation: the thermally improved spacer SGG SWISSPACER V excels with an optimised heat transfer resistance. The heat transmission coefficient is at least 0.1 W/m 2 K lower than that of conventional aluminium spacer bars. Reductions of up to 0.3 W/m 2 K can even be attained. The result: the high tech spacer bar SGG SWISSPACER V enables heating costs to be reduced by up to 5 %. That s easy on the wallet, and with reduced CO 2 emissions, also on the environment. Comfort Due to the superior isolation characteristics of SGG SWISSPACER V, higher temperatures are maintained at the edges of glass panes significantly reducing the risk of condensation forming. This, in turn, reduces the buildup of harmful mould and mildew on the window. Higher temperatures at the edge of the pane also mean less cold radiation, ensuring more comfort inside and a healthy indoor climate. Aesthetics The high-quality plastic of SGG SWISSPACER in combination with a unique colour range means you can design each window and any façade to perfectly suit your tastes. The attractive look brings a velvety, matt finish, without any shiny metal effects. Material Thermal conduction (W/mK) Aluminium 160 Stainless steel 15 Float glass 1 SGG SWISSPACER 0.16 Table 1 What is a Warm Edge? At the edge bonds, a gap is created between the double glazing panes with the help of spacers. This creates a space filled with inert gas or air between the glass panes, a key factor for the insulating efficiency of the glazing. The spacers create a linear thermal bridge of considerable length within the window component. When metal profiles are used, thermal heat is more or less released into the atmosphere along the entire transition area between glass and window frame. This loss is not only reflected in a building s energy balance, but also leads to a cooling of the inside surface temperature along the glass edge i.e. the edge becomes cold. If the surface temperature sinks below the dew point temperature of the surrounding air, condensation will develop a comfort and hygiene flaw which consumers frequently object to. Apart from the health risks posed to residents, long-term condensation can also cause damage to the window frame.

Environmental protection Lower heat requirements through better insulation SGG SWISSPACER saves energy. This benefits the environment in several ways. Unneeded energy must not be extracted, transported, supplied and processed. This not only saves resources but also decreases the level of CO 2 emissions in these areas. Moreover, by being 100 % recyclable, SGG SWISSPACER benefits not only the environment in terms of production but also later, in terms of disposal. Cost-effectiveness SGG SWISSPACER is cost-effective in two ways. On the one hand, no investment (or only minor investments) is necessary for processing. On the other hand, the consumer s pay-back time is only 5 years or so on average. With rising energy costs, this time period is reduced even further. Thus the use of SGG SWISSPACER represents a very sensible investment in terms of energy conservation, comfort, aesthetics and environmental protection. ENERGY SAVING BEST THERMAL VALUES COMFORT HIGHEST SURFACE TEMPERATURES AESTHETICS PERFECT DESIGN with SGG SWISSPACER without SGG SWISSPACER At low temperatures, condensation develops on windows along the edges of the glass panes. By using SGG SWISSPACER or SGG SWISSPACER V, the risk of condensation building up is significantly reduced as compared to the use of aluminium spacer bars. Taking wooden windows as an example: when aluminium spacers are used and with an outside temperature less than -1 C under consistent temperature boundary conditions, condensation begins to form. By integrating SGG SWISSPACER V, condensation only forms when outside temperatures drop to less than -10 C.

Product variety SGG SWISSPACER sets optimal visual accents from bold yellow to discreet grey. Titanium grey RAL 9023 Black RAL 9005 White RAL 9016 Sapphire blue RAL 5003 Light brown RAL 8003 Light grey RAL 7035 Dark brown RAL 8014 Sulphur yellow RAL 1016 Yellow-green RAL 6018 Opal green RAL 6026 Brown green RAL 7013 Beige RAL 1001 Beige brown RAL 1011 Pastel yellow RAL 1034 Grass green RAL 6010 Light ivory RAL 1015 Red brown RAL 8012 Further colours available upon request Similar to RAL tones Technology You have the choice Physical characteristics SGG SWISSPACER is a thermally optimised spacer bar made from a highly insulating composite plastic. Extremely thin metal membranes, consisting of either aluminium or stainless steel, guarantee both leak tightness for the filling gases and water vapour and an excellent adhesion for all insulation glass sealing compounds. SGG SWISSPACER is mechanically and thermally resistant up to constant temperatures of 100 C. Bended corners With the new bending system for our SGG SWISSPACER, you now have the opportunity to combine automation and aesthetics in insulation glass production for just a low investment. Plugged corners With corner keys, you can immediately begin using the SGG SWISSPACER without any investment whatsoever. Models with flexible corner keys are always possible. With the pre-butylated corner, you attain maximum economic production and security. with SGG SWISSPACER without SGG SWISSPACER Types SGG SWISSPACER product range SGG SWISSPACER SGG SWISSPACER V Georgian with aluminium membrane with stainless steel membrane bars Dimensions Widths for double glazing cavity: 11.5 mm x 20 mm 8, 10, 11, 12, 14, 15, 16, 18, 20, 22, 24 and 27 mm 11.5 mm x 24 mm 11.5 mm x 30 mm Overall height: 6.5 mm Length: 5.1 m, 6 m Corner keys (90 or flexible) in the same colour as the profile type, all widths, also available as pre-butylated model Cross connectors for Georgian bars With SGG SWISSPACER V, you achieve a temperature difference of up to 5.3 C at the edge of the glass under the same temperature conditions as without, and even with Georgian bars. Accessories Table 2 Stoppers for Georgian bars Steel longitudinal connectors: 8, 10, 12, 14, 15, 16, 18 and 20 mm Corner keys for manual gas filling: 12, 14, 16, 18 and 20 mm

5. 1. SWISS RE Tower in London with SGG SWISSPACER V, built in 2003 2. Turning Torso in Malmö with SGG SWISSPACER, built in 2005 3. BV Heiligendamm in Rostock with SGG SWISSPACER, built in 2002 4. Ilot M1G in Paris with SGG SWISSPACER, built in 2003 5. SGG SWISSPACER bending system 6. Forming process using the SGG SWISSPACER bending system 6. Thermotechnical data SGG SWISSPACER thermic performance in different types of window Double glazing Triple glazing Spacer system Aluminium Stainless steel SGG SWISSPACER SGG SWISSPACER V Aluminium Stainless steel SGG SWISSPACER SGG SWISSPACER V Wooden frames: Frame value: U f = 1.4 W/m 2 K 1.4 W/m 2 K Psi value [W/m 2 K] 0.081 0.053 0.047 0.032 0.086 0.052 0.046 0.031 Window, U w 1-sash [W/m 2 K] 1.4 1.3 1.3 1.3 1.1 1.0 1.0 1.0 Window, U w 2-sash [W/m 2 K] 1.5 1.4 1.4 1.3 1.3 1.2 1.1 1.1 Minimal surface temperature* [ C] 6.5 9.2 10.0 11.2 8.2 11.2 11.7 13.2 PVC windows: Frame value: U f = 1.2 W/m 2 K 1.2 W/m 2 K Psi value [W/m 2 K] 0.077 0.051 0.045 0.034 0.075 0.048 0.042 0.032 Window, U w 1-sash [W/m 2 K] 1.3 1.3 1.2 1.2 1.0 1.0 1.0 0.9 Window, U w 2-sash [W/m 2 K] 1.4 1.3 1.3 1.3 1.2 1.1 1.0 1.0 Minimal surface temperature* [ C] 7.7 10.2 10.7 12.0 9.0 11.5 12.0 13.0 Wood-aluminium windows: Frame value: U f = 1.4 W/m 2 K 1.4 W/m 2 K Psi value [W/m 2 K] 0.092 0.058 0.052 0.035 0.097 0.058 0.051 0.033 Window, U w 1-sash [W/m 2 K] 1.4 1.3 1.3 1.3 1.2 1.1 1.0 1.0 Window, U w 2-sash [W/m 2 K] 1.6 1.4 1.4 1.3 1.3 1.2 1.2 1.1 Minimal surface temperature* [ C] 5.0 8.2 9.0 10.5 7.2 10.5 11.0 12.5 Aluminium windows: Frame value: U f = 1.6 W/m 2 K 1.6 W/m 2 K Psi value [W/m 2 K] 0.111 0.068 0.060 0.039 0.111 0.063 0.056 0.034 Window, U w 1-sash [W/m 2 K] 1.5 1.4 1.4 1.3 1.2 1.1 1.1 1.1 Window, U w 2-sash [W/m 2 K] 1.7 1.5 1.5 1.4 1.5 1.3 1.3 1.2 Minimal surface temperature* [ C] 7.2 10.2 10.7 12.0 9.2 12.2 12.7 14.0 The technical values were determined in accordance with ift guideline WA-08/1 Thermally Optimised Spacers Part 1: Determining the Representative Psi Value for Window Frame Profiles. Psi value: linear heat conductivity at edge of glass [W/m 2 K] to satisfy EN ISO 10077-2, 10/2003 * corresponds to the edge conditions set out in EN 10077 Outside temperature Ta: -5 C Inside temperature Ti: +20 C Table 3 Window geometry window, 1 sash: window, 2 sashes: Total surface: (1.23 x 1.48 m) Aw = 1.82 m 2 Aw = 1.82 m 2 Frame surface: Af = 0.55 m 2 Af = 0.69 m 2 Length of glass edge: lg = 4.54 m lg = 6.84 m

Contact SWISSPACER Saint-Gobain Glass Solutions Sonnenwiesenstr. 15 CH-8280 Kreuzlingen Tel.: +41 71 686 9270 Fax: +41 71 686 9275 E-Mail: info@swisspacer.com www.swisspacer.com The company A company of the Saint-Gobain Group As a company of Saint-Gobain Glass Solutions, the leading network of glass fabricators in Europe, SWISSPACER has access to global knowledge transfer and innovations on an international level. Since the firm s establishment in 1998, our products have been convincing consumers due to outstanding technical and aesthetic characteristics. With the SGG SWISSPACER spacer system, we are your high-performance partner for the future. By offering these products, we not only contribute our part to climate protection but are also able to lower heating costs. New version Caluwin 4.0 With Caluwin 4.0, we provide you with a high-quality calculation program absolutely free of charge! You can use it not only to compute the thermal conductivity coefficient U w, of a window based on the latest standards, glass data and technical specifications, but also the dew point for double as well as for triple glazing. The latest version for façades will also be available by the summer of 2008. The computation is carried out an affiliate of in accordance with EN 13947: 2007, and along with the component method now also offers the simplified computation method. Updated Psi values, calculated by Prof. Franz Feldmeier (UAS Rosenheim) in accordance with EN 10077, allow calculations for façade post-and-beam systems, as well as special designs, e.g. glass butts or structural glazing constructions. This enables you to compute the most current U cw values for nearly any type of façade. Cologne 03.2008 Data subject to change. SGG SWISSPACER is a registered trademark.