Owner s Manual Phoenix Solution. LGR Performance Amplifier



Similar documents
Owner s Manual Phoenix R175 LGR Dehumidifier

Lien Rd. Madison, WI Owner s Manual Phoenix R200 LGR Dehumidifier

Owner s Manual Phoenix Arctic Max

Owner s Manual Phoenix D385

Quest 105, Dry155, and 205 Dual

INSTALLER S & OWNER S MANUAL

Owner s Manual Phoenix 200 MAX

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

INSTALLER S & OWNER S MANUAL

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Owner s Manual Phoenix 300

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Owner s Manual Phoenix 1200 Desiccant Dehumidifier

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

ATS Overhead Table Shelf System INSTRUCTION MANUAL

User s Guide. Oreck Air Purifier with HEPA Filtration. Important! Read this manual carefully, and keep for future reference.

Advantium 2 Plus Alarm

Installation Instructions

USER S MANUAL HSC-24A

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

, User s Manual

Ceiling Mount Air Handler Manual

16/32 Channel 1U Rack Mount CCTV Power Supply

HI-E Dry DRY 195. quest. Read and Save These Instructions. Installation, Operation and Maintenance Instructions. HI-E Dry 195:

ACW200C / ACW200CH. Innovative AutoDrain Technology. Owner s Manual Portable Air Conditioner with Heat

Portable Evaporative Air Cooler for Indoor Use. OWNER S MANUAL Read and save these instructions before use. Model: CL25AE

Portable Evaporative Air Cooler for Outdoor, Indoor & Commercial Use. OWNER S MANUAL Read and save these instructions before use.

Air Conditioning Systems Warranty Manual. Version 1.8

WINDOW ROOM AIR CONDITIONER

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

FOXAIR 60/50 ALL MODELS

USE &CARE GUIDE. Remote Faucet Pump System. See Important Safeguards on page 2

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

WHYNTER ECO-FRIENDLY 14,000 BTU PORTABLE AIR CONDITIONER WITH HEATER

Service & Parts Manual

Electric Fryers Instruction Manual Models: 8047D, 8048D, 8049D, 8050D, 8051D 8066, 8068, 8068FL, 8073, 8073BF and 8075

Tablet 30W Tablet 92W

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Portable Air Conditioner

AIR CONDITIONER & HEAT PUMP DIGITAL CONTROL FOR DUCTED SYSTEM INSTALLATION AND OPERATING INSTRUCTIONS

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

INSTANT HOT WATER RECIRCULATING SYSTEM

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual

PORTABLE AIR CONDITIONER CLIMATISEUR PORTATIF ACONDICIONADOR DE AIRE PORTATIL

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

T15 AIR CONDITIONER INSTRUCTION MANUAL FOR: McLean Thermal Business Park Blvd. N Champlin, MN Tel: Fax:

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Dehumidifier Users manual. For Models: DH45S DH65S

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

Model: Model: Description: Voltage: Amps: Ice Type: Unit Weight:

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

FASCINATION 700 HVLP TANNING PRO SYSTEM USER MANUAL

Wine Cooler with Thermo-Electric Cooling & Heating Technology

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

ROTOR LOADER OWNER S MANUAL

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

Mini-led spotlight with magnetic base

About this Manual. Support for Your Product

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

Instructional & Operating Manual

1/3 HP Submersible Sump Pump with Vertical Float Switch

Home Owners Guide HR SERIES HEAT RECOVERY VENTILATOR (HRV) Models HR100V, HR160H & HR220H RESIDENTIAL USE ONLY HR160H & HR220H

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

PALLET JACK TON

Tyan Computer. Transport PX22. Service Engineer s Manual

Foodservice Equipment Specialists P.O. Box 880 Saco, ME. / U.S.A * FAX (207)

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

ALL WEATHER W-SERIES QUARTZ TUBE ELECTRIC INFRARED RADIANT HEATER INSTALLATION USE & CARE MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Central Air Conditioner

EXTENDED SERVICE AGREEMENTS

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Automatic Phone-Out Home Monitoring Systems

Instructions & Safety Information Models A220-20D and A220-20L Version 2

ECM Blower Motor Replacement Controls Programming Process

Nest Learning Thermostat Installation Guide. Installation step-by-step

StorTrends 3400 Hardware Guide for Onsite Support

FUTURE CALL PICTURE CARE PHONE MODEL: FC-1007 USER MANUAL

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

LOBOY 16 AIR CONDITIONERS

INSTRUCTION MANUAL FOR RECREATIONAL REFRIGERATOR/FREEZER MODEL

Figure 2 The fan and shroud also needs to be removed for access to the four a/c compressor bolts and removal of the compressor from the top.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

MODEL INSTALLATION INSTRUCTIONS

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

Alarm Clock USER GUIDE

AROS SMART WINDOW AIR CONDITIONER

INSTRUCTION BOOK FOR. Single Monitor Video Conference Cart

Installation and Operation Guide for PD5100 Automatic Transfer Switch

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

Transcription:

Owner s Manual Phoenix Solution LGR Performance Amplifier Read And Save These Instructions Phoenix Solution LGR Performance Amplifier Manual Part Number TS-332 The Phoenix Solution is a LGR performance amplifier designed to compliment the Phoenix 200 MAX and Phoenix 200 HT series LGR Dehumidifiers. The Solution pre-cools the air to the 200 MAX or 200 HT using the Phoenix air to air heat exchanger and any available secondary air stream. The secondary air stream will come from a cooler source, either separate A/C system, unaffected or ambient outside air. The cooling effect of the Solution when combined with the low grain performance of the 200 MAX and 200 HT allows for even higher drying ambient temperatures and/or the use of additional equipment for higher evaporation rates and shorter drying times. The Phoenix Solution LGR Performance Amplifier All Stainless Steel Construction - gives it a sleek durable look while keeping functionality. Recessed Handles - and carrying points for ease of transport and installation. High Performance Impeller - for driving secondary air stream, thermostatically controlled to prevent overcooling. Condensate Management System - directs condensation to the dehumidifier s condensate pump system. Faster Evaporation Rates - and shorter drying times. Figure 2: Phoenix Solution P/N 4026600 Primary Air Stream Figure 1: Features and Benefits Figure 3: Air Flow Diagram Secondary Air Stream Copyright Therma-Stor LLC 1 Issue 05/06

Table of Contents Introduction 1 1. Intended Application 2 2. Specifications 2 3. Set Up 2 3.1 Transporting 2 3.2 Installination 2 3.3 Ducting 3 3.4 Condensate Removal 3 3.5 Electrical Requirements 3 3.6 Control Switch 3 4. Maintenance 3 5. Service 3 5.1 Technical Description 3 5.2 Troubleshooting 3 5.3 Blower Replacement 3 5.4 Thermostat & Switch Replacement 3 6. Options & Accessories 4 7. Wiring Diagram 4 8. Installation Diagram 5 9. Warranty 6 10. Service Parts 7 Read the operation and maintenance instructions carefully before using this unit. Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Solution dehumidifier amplifier. WARNING It is designed to be used INDOORS ONLY. If used in a wet area, plug it into a GROUND FAULT INTERRUPTER. DO NOT use the Phoenix Solution as a bench or table. It must always be used in the upright position. The included bracket with engaging tabs must be installed correctly on the dehumidifier that the Phoenix Solution is attached to. The Phoenix Solution must be removed from the dehumidi fier for transport to and from the jobsite. 1 Intended Application The primary air stream inlet on top must be at least 1 foot from walls and other obstructions to air flow. The secondary air stream on the front and side must be ducted from and to an area other than the area being dried. Care should be taken to separate the secondary air source connection points to avoid recirculation through the Solution. 2 Specifications Model: Phoenix Solution (P/N 4026600) Electrical: 110-120 Vac, 1.6 Amps, grounded Operating CFM & Temperature Range: Primary air stream 300 CFM & 33 F min., 125 F max. Secondary air stream 230 CFM & 15 F min., 125 F max. Duct Connections: 4 x 10 rectangular exhaust 8 round intake Size: 19 high x 19-1/2 wide x 19-1/2 deep Weight: 40 lbs 3 Set Up 3.1 Transporting The Phoenix Solution is designed to be carried by the recessed handles built into the front and rear of the unit. Multiple Solutions may be stacked for transport on a suitable cart. Transporting the Phoenix Solution as it is attached to a dehumidifier is NOT RECOMMENDED. 3.2 Installation The top of the Phoenix Solution is designed to accept the filter and top cover from the Phoenix 200 MAX or Phoenix 200 HT that it is mounted on. The Phoenix Solution is designed to engage the spring clips found on the Phoenix 200 MAX and 200 HT dehumidifiers. An additional bracket with engaging tabs (1 included) must be installed on the dehumidifier to secure the front of the Phoenix Solution chassis. Figure 4: Bracket installed in Phoenix HT using existing fasteners. Note tabs bent down between plastic heat exchanger panels. 200 MAX installation is similar. Figure 5: The front of the Solution has four slots to engage the tabs on the dehumidifier bracket. The top two slots are for use when installing on a Phoenix 200 HT and the bottom two are for use on a Phoenix 200 MAX. 2 Phoenix Solution Owners Manual

4 Maintenance Any accumulated debris can be removed from the inlet of the Solution by inserting a vacuum cleaner head into the 8 inlet. Figure 6: Solution slides forwards and engages clips on side of dehumidifier. 3.3 Ducting A detachable rectangular duct ring is supplied to allow 10" round lay-flat duct to be attached to the Phoenix Solution outlet. Lay-flat plastic ducting is available. See accessories table section 6. To attach ducting to a ring, put the plastic duct end through the ring center and roll the duct end outward so that it overlaps the outside of the ring. The duct and ring may then be quickly attached to the Phoenix Solution by snapping the ring over the three screws at the blower outlet. 3.4 Condensate Removal In applications where the temperature of the secondary air stream is significantly below the dew point of the primary air stream, condensation may occur inside the Solution s heat exchanger. A drip pan underneath the heat exchanger, along with the mounting bracket secured in the dehumidifier, direct condensate into the dehumidifier s drain pan for removal. 3.5 Electrical Requirements The Phoenix Solution plugs into a common grounded outlet on a 15 Amp circuit. It draws 1.6 Amps with the blower running. If used in a wet area, a ground fault interrupter (GFI) is required. If an extension cord is required, it must be a minimum 14 gauge conductor rating if it is 25 or less. Longer extension cords require a minimum 12 gauge conductor rating. 3.6 Control Switch The Solution includes a three position power switch located on the back of the device. The center position is OFF, the bottom position is ON, and the top position is THERMO- STAT. Switching the unit ON will cause the blower to run continuously. Switching the unit to THERMOSTAT will prevent the Solution from over-cooling the room by shutting the blower off if the room falls below 70 F. Note that on the THERMOSTAT setting, the blower will not come on until the primary air stream heats up above 80 F. 5 Service 5.1 Technical Description The Phoenix Solution uses an air to air heat exchanger and a secondary air stream (air supplied from a location other than the area being dried) to pre-cool the air drawn into a Phoenix dehumidifier. It does this with a thermostatically controlled impeller type air mover. The thermostat is a common bimetallic switch with its sensing element in the process or primary air stream (supply air to dehumidifier). The thermostat is set to turn the impeller on when the process air temperature increases to 80 F. The thermostat will turn the impeller off when the process air cools to 70 F. Alternatively, the power switch can be set to run the blower continuously if desired. 5.2 Troubleshooting Blower not running when set to ON 1. No power to unit 2. Loose connection in blower circuit 3. Obstruction prevents impeller rotation 4. Defective Blower Thermostat warm but blower doesn t run when set to THER- MOSTAT 1. No power to unit 2. Thermostat not working - replace 3. Loose connection in blower circuit 4. Obstruction prevents impeller rotation 5. Defective Blower 5.3 Blower Replacement The motorized impeller has a PSC motor and internal thermal overload protection. If defective, the complete assembly must be replaced. 1. Unplug the power cord 2. Turn unit upside down and remove three impeller assembly mounting screws from the bottom of the unit 3. Turn unit right side up and remove four impeller assembly mounting screws from the back of the unit and two from the side near the impeller exhaust opening 4. Lift impeller assembly out of unit 5. Remove four screws holding impeller bracket to impeller orifice panel 6. Remove the fasteners holding the impeller and impeller power cord to the impeller bracket 7. Reverse the above procedure for reassembly 5.4 Thermostat & Switch Replacement Remove the blower assembly as described for replacing the blower. Disconnect defective components and replace. Phoenix Solution Owners Manual 3

6 Options & Accessories 4020177 8 Insulated Intake Flex Duct 4024935 Lay-Flat Duct 10 Round x 250 Roll 4022537 Lay-Flat Duct 10 Round x 500 Roll 4026557 Solution Dehumidifier Mounting Brackets To order, contact Therma-Stor LLC at 1-800-533-7533. 7 Wiring Diagram TO CORD PLUG GRN WHT PHOENIX SOLUTION WIRING DIAGRAM THERMOSTAT POWER SWITCH BLU BLOWER MOTOR FAN CAPACITOR ALTERNATE FAN CAPACITOR BRN BRN Therma-Stor LLC PO BOX 8050, MADISON, WI 53708 1-800-533-7533 PART NO. 4026422 REV. 0 Figure 5: Wiring diagram 4 Phoenix Solution Owners Manual

8 Installation Diagram PHOENIX Solution LGR Performance Amplifier Outside Air Outside Air Unaffected Area Air Unaffected Area Air Simple Set-Up Air Conditioning Return or to Room 1. Remove Top and Filter from 200 Max or 200 HT. 2. Attach Solution mounting bracket to LGR. 3. Set the Solution into the top of the LGR and slide into the mounting bracket captures. 4. Place Filter and Top on the Solution. 5. Find the coolest air source from outside, the unaffected area or air conditioning. 6. Duct as shown in drawing. 7. Plug units in and turn On/Thermostat. The PHOENIX Solution will boost the performance of your LGR dehumidifier in nearly every condition, and will dramatically widen the temperature range for significant water removal. The Solution is a specially designed intercooling head that provides pre-cooling to the dehumidifier s incoming air stream. Just like the pre-cooling feature is the key to the performance leap of LGR dehumidifiers, the Solution can actually double the water removal rate of your LGR in some conditions. The enhanced efficiency achieved with the Solution practically matches the 1.6 amps required to operate the unit, resulting in a minimal overall power increase. X ENI PHO0 HT 20 NT RA CE IGERMAN O REFR PERF AIN RE GR RATU Air Conditioning Supply W PE LOH TEM HIG a-stor Therm LLC dison Ma, WI 0-533 80-7533 P/N 4026418 Figure 8: Installation diagram Phoenix Solution Owners Manual 5

Phoenix Solution LRG Performance Amplifier Limited Warranty Warrantor: Therma-Stor LLC PO Box 8050 Madison, WI 53708 Telephone: 1-800-533-7533 Who Is Covered: This warranty extends only to the original end-user of the Phoenix Solutions amplifier, and may not be assigned or transferred. Year One: Therma-Stor LLC warrants that, for one (1) year the PHOENIX Solution will operate free from any defects in materials and workmanship, or Therma-Stor LLC will, at its option, repair or replace the defective part(s), free of any charge. End-User Responsibilities: Warranty service must be performed by a Servicer authorized by Therma-Stor LLC. If the end-user is unable to locate or obtain warranty service from an authorized Servicer, he should call Therma-Stor LLC at the above number and ask for the Therma-Stor Service Department, which will then arrange for covered warranty service. Warranty service will be performed during normal working hours. The end-user must present proof of purchase upon request, by use of the warranty card or other reasonable and reliable means. The end-user is responsible for normal care. This warranty does not cover any defect, malfunction, etc. resulting from misuse, abuse, lack of normal care, corrosion, freezing, tampering, modification, unauthorized or improper repair or installation, accident, acts of nature or any other cause beyond Therma- Stor LLC s reasonable control. will be extended by the period of time, if any, that the PHOENIX Solution is out of service while awaiting covered warranty service). UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE PHOENIX SOLUTION OR ANY PART THEREOF, ALL OTHER WARRANTIES IMPLIED BY LAW, INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL ALSO EXPIRE. ALL WARRANTIES MADE BY THERMA-STOR LLC ARE SET FORTH HEREIN, AND NO CLAIM MAY BE MADE AGAINST THERMA-STOR LLC BASED ON ANY ORAL WARRANTY. IN NO EVENT SHALL THER- MA-STOR LLC, IN CONNECTION WITH THE SALE, INSTALLATION, USE, REPAIR OR REPLACEMENT OF ANY SOLUTION OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE (THE END-USER SHOULD TAKE PRECAUTIONS AGAINST SAME), LOST PROFITS, DELAY, OR LOSS OF USE OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY. Some states do not allow limitations on how long an implied warranty lasts, and some do not allow the exclusion or limitation of incidental or consequential damages, so one or both of these limitation may not apply to you. Legal Rights: This warranty gives you specific legal rights, and you may also have other rights which vary from state to Limitation and Exclusions: If any PHOENIX Solution part is repaired or replaced, the new part shall be warranted for only the remainder of the original warranty period applicable thereto (but all warranty periods 6 Phoenix Solution Owners Manual

10 Service Parts Item Description Qty Part Number 1 Impeller 1 4025076 2 Capacitor 1 4025224 3 Power Switch 1 4024871 4 Thermal Switch 1 4026416 4 3 1 2 2001 S. Stoughton Road Phone 608-222-5301 Madison,WI 53708 Toll-Free 1-800-533-7533 www.thermastor.com sales@thermastor.com 2005 Therma-Stor LLC 3/2005 Information and specifications subject to change without notice. Phoenix Solution Owners Manual 7