2WIN Binocular Mobile Refractometer and Vision Analyzer

Similar documents
Smart Refractor RT-3100

The light. Light (normally spreads out straight and into all directions. Refraction of light

Phoroptor VRx Digital Refraction System

Refractive Surgery in Children Indications and Non-Indications

M A R C O. CP-670 AUTOMATIC CHART PROJECTOR Instruction Manual

2) A convex lens is known as a diverging lens and a concave lens is known as a converging lens. Answer: FALSE Diff: 1 Var: 1 Page Ref: Sec.

ABrand New Refraction Meas urement Instrument

Progressive Lens Troubleshooting

Information. From the LowVision Specialists. Guidelines for the fitting of telescopic systems

9/16 Optics 1 /11 GEOMETRIC OPTICS

Instructions on Completing VIP Gold Standard Examination Form For Children Wearing Glasses (12/15/03)

Imaging Systems Laboratory II. Laboratory 4: Basic Lens Design in OSLO April 2 & 4, 2002

Customized corneal ablation can be designed. Slit Skiascopic-guided Ablation Using the Nidek Laser. Scott MacRae, MD; Masanao Fujieda

Information for parents and guardians

Geometrical Optics - Grade 11

Vision Care Services (Includes Ophthalmological Services)

Professional Fitting and Information Guide

Smallest design. Biggest impression. Impressively thin. Retractability. See more of your patient. See more patients. Thinnest Phoroptor yet.

Esotropia (Crossed Eye(s))

Lecture 17. Image formation Ray tracing Calculation. Lenses Convex Concave. Mirrors Convex Concave. Optical instruments

1 Laboratory #5: Grating Spectrometer

MAVO-MONITOR / MAVO-SPOT Instrument Set for Contact or Distant Measurements of Luminances

Color and Light. DELTA SCIENCE READER Overview Before Reading Guide the Reading After Reading

Astigmatism. image. object

Exotropias: A Brief Review. Leila M. Khazaeni, MD November 2, 2008

No need to wear distance or near glasses now or ever again

HRK-7000 / HRK-7000A Auto Ref-Keratometer

En Wireless Mobile Utility (Android) User s Manual. D610, D600, D7100, D5300, D5200, D3300, Df

Vision Correction in Camera Viewfinders

Introduction to Lensometry Gregory L. Stephens, O.D., Ph.D. College of Optometry, University of Houston 2010

CHEMALUX 100OD SYSTEM. CHEMAT VISION - partner in vision care

GLASSES VERSUS OBSERVATION FOR MODERATE HYPEROPIA IN YOUNG CHILDREN (HTS1)

Vestibular Assessment

Welcome to the Verisyse Seminar

Additional details >>> HERE <<<

Handheld USB Digital Endoscope/Microscope

Incision along Steep Axis

Detachable DIY Door Viewer Camera for Home / Office Safety. Installation Manual. (* This is a patented product, do not copy) IA Technologies Inc.

Chapter 6 Telescopes: Portals of Discovery. How does your eye form an image? Refraction. Example: Refraction at Sunset.


LASIK. Cornea. Iris. Vitreous

Tobii Technology AB. Accuracy and precision Test report. X2-60 fw Date: Methodology/Software version: 2.1.7

Technical Data FLIR E40bx (incl. Wi-Fi)

Patient-Reported Outcomes with LASIK (PROWL-1) Results

Rediscover quality of life thanks to vision correction with technology from Carl Zeiss. Patient Information

3D GLASSES FOR SHARP 3D AQUOS OPERATION MANUAL

DEPENDABLE ACCURACY. RIGHT TO THE POINT.

THE EYES IN MARFAN SYNDROME

Lenses and Telescopes

Tucson Eye Care, PC. Informed Consent for Cataract Surgery And/Or Implantation of an Intraocular Lens

LASER VISION CORRECTION: WHAT YOU SHOULD KNOW.

Physics 1230: Light and Color

Geometric Optics Converging Lenses and Mirrors Physics Lab IV

Tube Control Measurement, Sorting Modular System for Glass Tube

Installation and use of Millett Tactical TRS-1 and TRS-2 scopes TRS-1 TRS-2. Before starting, make sure firearm is UNLOADED!!

TS-E24mm f/3.5l TS-E45mm f/2.8 TS-E90mm f/2.8 Instructions

Theremino System Theremino Spectrometer Technology

PRODUCT SHEET.

Ektalite Slide Projectors

EyeMag Medical Loupes from ZEISS Seeing is believing NEW! LED illumination

Vision Glossary of Terms

Eye Tracking Instructions

THE GUIDE TO REFRACTIVE LENS EXCHANGE SEE CLEARLY.

Operation Guide VIP-45-WIFI. Video Inspection Probe

VIDEO SURVEILLANCE PRODUCT CATALOG Uniden America Corporation R15 2K 1212

IBRA Professional. Leading Technology for Refractive Outcome Analysis. Brochure 2015

PATIENT INFORMATION BOOKLET

CATARACT SURGICAL PACKAGES

Installation and Setup

Wavefront higher order aberrations in Dohlman/Boston keratoprosthesis and normal eyes

Tobii AB. Accuracy and precision Test report. Tobii Pro X3-120 fw Date: Methodology/Software version: 2.1.7*

Laser Vision Correction

En Wireless Mobile Utility (Android) User s Manual. D750, D610, D600, D7200, D7100, D5500, D5300, D5200, D3300, Df

Patient Information Content

Nintendo 3DS XL Quick-Start Guide

Tobii X2 Eye Trackers

ES-CAM2AU IP Camera.

Clinical Techniques for Prescribing BiopticTelescope Devices

The Digital Camera. Taking Pictures 1. manual of your digital camera for details. Notes Compiled by James Cilia & Emile Vassallo 42

AUTO PHOROPTOR. Auto Refraction System. User s Guide

LASIK Information Kit

ReLEx smile Minimally invasive vision correction Information for patients

Precision Lightmeters Made in Germany

VISX Wavefront-Guided LASIK for Correction of Myopic Astigmatism, Hyperopic Astigmatism and Mixed Astigmatism (CustomVue LASIK Laser Treatment)

Advanced Eyecare of Orange County Kim Doan, M.D. Eye Physician & Surgeon

MS9500 SERIES VOYAGER PRODUCT GUIDE. Single Line, Hand-Held, 1D, High-Density 1D, PDF-417 2D and Wireless Laser Bar Code Scanners

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Three pearls in one shell. Heidelberg Retina Tomograph

How To Use An Irius Pid Detector

SONAPHONE. The New Device Class for Preventive Maintenance

LASIK. What is LASIK? Eye Words to Know. Who is a good candidate for LASIK?

Kerry D. Solomon, MD, is Director of the Carolina Eyecare Research Institute at Carolina Eyecare Physicians in Charleston, S.C.

Dual Laser InfraRed (IR) Thermometer

LASIK & Refractive Surgery

PresbyMAX For visibly younger eyesight

Experiment 3 Lenses and Images

PDF Created with deskpdf PDF Writer - Trial ::

Magnification Devices

Operator s Maintenance Manual STEINER BINOCULARS. Military ruggedness and precision 07/03

Transcription:

2WIN Binocular Mobile Refractometer and Vision Analyzer The smartest way to detect refractive errors and vision problems

Adaptica was founded in 2009 as a spin-off of the University of Padova, Italy specialising in adaptive optics and optoelectronics applied to Industry and astronomical research. Adaptica leverages on its technological know-how and competences in Astronomy to move from a better vision of the universe and its galaxies towards exploring vision and the human eye. Shortly after, Adaptica expanded into health-care with particular focus to vision and eye-care. Adaptica develops and manufactures mobile, smart and ease of use diagnostic pieces of equipment that are currently distributed in 40+ countries around the world. 2 www.adaptica.com

Device and main applications The 2WIN is a mobile binocular refractometer and vision analyzer that measures both eyes at the same time, in real life vision conditions. Refraction of infants and children from 2 months of age, seniors, impaired and non-cooperative patients. Early detection and documentation of multiple amblyogenic factors. Un-aided binocular refraction of all other patients. Over-refraction of glasses or contact lenses. Refraction The 2WIN measurement principle is eccentric photo-retinoscopy. Infrared (IR) light is projected through the patient pupils and onto the retina. Depending upon the refractive error, the reflected light forms a specific crescent-shaped brightness pattern within the pupil. The 2WIN measures spherical power, cylinder power and axis by interpreting the reflected light crescent pattern and position. The 2WIN infrared exam also provides valuable information about corneal abnormalities as well as ocular media opacities such as cataracts. Measurements Refractive errors Sight anomalies Pupil parameters Refractive errors - Myopia, hyperopia, astigmatism and other amblyogenic factors. Sight anomalies that may be related to anisometropia, anisocoria, strabismus, phoria. Pupil parameters - pupil size, pupil distance and head tilt. Benefits 100% mobile Binocular, 1 meter Hand-held, small, Battery operated Easy, quick, working distance light weight (long battery life) non-invasive Cost effective 3

Ideal with infants, children and non-cooperative patients. It measures refraction and correction in natural vision conditions. How to use the 2WIN Ambient light: a uniform dim light environment is necessary (not totally dark nor too bright) to achieve 3,5 to 6 mm pupil size; in addition make sure that no direct light hits the patient s face and ensure uniform light on both eyes. Stand or sit at 1 meter distance from the patient and firmly hold the 2WIN horizontally with both hands. Instruct the patient to keep his/her eyes wide open, clear of eyelids or eyelashes, and to fixate on the center of the camera. The 2WIN operates as a photo camera, thus proper focusing is necessary by slightly moving the instrument forward and backword. The green bar in the display indicates when the ideal focal distance of 1 meter has been reached. Make sure the corneal reflexes appear as small and bright as possible. Press and hold the START button to enter the focusing phase. Slightly adjust the distance looking at the corneal reflexes until the image comes into focus and the focus bar is green. Release the START button and the 2WIN automatically displays the measurements on the screen within approx. 3 seconds. How to read the display Cylinder Right Eye Sphere Axis Left Eye Screening Result: Realiability index Measurement Window Live Display Fixation Plot Pupil & Gaze Status Bar Amblyopia screening Pupil distance Gaze Head Tilt Pupil size Fixation Plot TEST THRESHOLD RESULT Hyperopia Sph < 1.5 d Ok Myopia Left Eye Sph < 0.75 d No Astigmatism Cyl < 1.5 d Ok Anisometropia Diff < 1 d No WiFi USB Age range Visible Fixation Target Battery Life Audible Fixation Target Anisocoria Diff < 1 mm Ok Gaze < 6 Ok 4 www.adaptica.com

How to read the printout 2WIN measurements can be stored and/or printed. The exams are stored internally in a micro-sd card in.pdf format. Exam Date Right Eye Left Eye Sphere Cylinder Axis Spherical Equivalent Index of Reliability Gaze Pupil Distance Pupil Size Fixation Plot Years and Outcome Criteria Dr s signature Screening Result 5

Additional features Connectivity The 2WIN is equipped with a WiFi module and can be connected to a computer network. Download and visualize patient data from the 2WIN to an external device. 2WIN exams and patient data can therefore be downloaded and visualized on external devices such as smartphone, tablet, pc by using a secure file transfer client software. The external smart device can be used to input patient information and/or other data and commands. 2WINNY mask kit 2WINNY is a funny, attractive and removable mask to help the operators in daily interactions with infants and children. It is an accessory designed to draw kid s attention on the 2WIN before starting the examination and activating the visible and audible fixation targets. Operators select the mask on the basis of child age and apply it on the front side of the 2WIN. 6 www.adaptica.com

Intermediate Distance application The 2WIN measures the patient s refraction while reading from VDUs, at a distance of 66 cm (2 ). In all those cases when reading at such distance proves difficult, the 2WIN calculates the necessary additional power (ADD) to restore best vision. The application requires the use of an additional lens that is inserted in the central aperture of the 2WIN; the additional lens together with a 66 cm reading chart completes the kit. Analysis of corneal reflexes This application provides complete information regarding the position of corneal reflexes. Measurements are expressed either in prism diopters or degrees. A black hand held filter is included and allows the 2WIN infrared rays to pass through while blocking all visible light: therefore a reliable cover test is made possible. When a deviation appears in the uncovered eye the output is ET: esotropia; XT: exotropia. When a deviation appears in the covered eye the output is EP: esophoria; XP: exophoria. When a vertical deviation appears the output follows the same rules above exposed (HT: hypertropia; IT: ipotropia; HP: hyperphoria; IP: ipophoria). Complete and objective assessment of the visual function. Early detection of refractive errors. Technical specifications Operating mode: Binocular/monocular Refraction Measurement: Automatic Sphere range: ±5 D, precision 0.25 D Cylinder range: ±5 D, precision 0.25 D Cylinder axis: 1-180, step 1 Pupil size: Automatic detection, 4-7 mm, step 0.1 mm Working distance: 1 m ± 5 cm Data Interface: Wi-Fi, USB, microsd card Printer interface: USB, Infrared (irda) Power: Rechargeable battery Battery charger: 110-220 Vac, 0.5 A Size: 165x130x98mm Pupil distance: Automatic detection, 30-120 mm, step 1 mm Display: 3.5 Fixation target: Built-in Acoustic target: Built-in Weight: 840 g (30 oz) Options/Accessories: Portable wireless printer, supplementary battery, battery-charger, metal case, WiFi connectivity 7

Rev. 0.2-2016 EN The 2WIN has been a great addition to our office. It has given me objective data on young children that are often hard to get good co-operation and fixation. R. Scott Penny, O.D. Sprinfield, OH Adaptica Srl C/o Net Center Via San Marco, 9/H 35129 Padova, Italy Ph +39 049 773 968 Fax +39 049 097 0901 www.adaptica.com contact@adaptica.com