User Guide IM/AP200 Rev. R. AP200 series Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes



Similar documents
Instruction Manual IM/LM_3. Field IT. Data Capture Utility. LogMaster

Electromagnetic Flowmeters

Combination ph/redox (ORP) Sensors

PART 1 - INTRODUCTION...

General Purpose ph/orp Sensors

TB2CS Conductivity sensor 2-Electrode. Superior accuracy in low level conductivity measurement ranges

Submersion/Insertion Toroidal Sensor

SenTix 950 SenTix 980

Setup guide IM/WM/VM EN Rev. B. VeriMaster Software tools

ATL Fuel Level Sender Probes

ph Measurement and Control

Trace Dissolved Oxygen Sensor

Dissolved Oxygen Sensors

Toroidal Conductivity Sensor

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

ExStik TM ph Waterproof Meters

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Pipe threads for tubes and fittings where pressure-tight joints are not made on the threads. (requires PTFE sealing tape or liquid sealant).

Plastic tube flowmeters Series PT/PS

Digital inductive conductivity transmitter

Operating Instructions

For additional information, please visit our website at

REPAIR AND MAINTENANCE MANUAL

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

CalMaster2 Field and Software Tools. The world's first battery- and mains-powered in situ flow verification system

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

Instructions Manual. Electromagnetic sensor Series FLOMID FX. instrumentation for fluids. R-MI-FlomidFX Rev.: 0 English version

ph Sensor Model 397 CAUTION SENSOR/PROCESS APPLICATION COMPATIBILITY WARNING ATEX DIRECTIVE Instruction Sheet PN 51A-397/rev.

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flow rates

Operator Quick Guide EC SENSOR

Stainless Steel Single and Dual Circulation Kits

SHOT BLAST CABINET MODEL NO: CSB20B

User Guide IM/AX4PH Rev. O. AX416, AX436, AX460, AX466 & AX468 Single and dual input analyzers for ph/redox (ORP)

General Purpose ph/orp Sensor

StackFlowMaster FPD580 TORBAR probe Stack gas metering systems. Measurement made easy. Introduction. For more information

Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

PBX Series Quick Fit Connector Bimetallic Steam Traps

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FOR EXHEAT INDUSTRIAL IMMERSION HEATERS (INCLUDING FLAMEPROOF)

Cables. Accessories. For Force, Torque and Strain Sensors

Please also see 10 golden rules for correct Saniflo installation on

Maintenance Guide IM/AZ20M EN Rev. C. Endura AZ20 series probe Combustion oxygen monitor

RayClic Connection System Installation Instructions

Explosion proof enclosures

This unit is a pump that will clear the waste from a domestic shower and washbasin, bath, washing machine, glass washer and a sink.

Submersion/Insertion Toroidal Sensor

123 Industrial Loop Road Paynesville, MN Phone:

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

123 Industrial Loop Road Paynesville, MN Phone: MASTER MANUFACTURING MASTER GARDNER

Artisan Thermostatic basin mixer. Fitting Instructions & Contents List

DiwiTherm, Resistance Thermometers Model TR75, with digital Display Battery or Solar Powered

Coolflo Safe Touch Shower Mixing Valve ST20015CP

Care and use guide. Contents. a handy solution made easy. page

Directory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U Technical characteristics types D and E

Stainless steel process fittings

NÜVE SANAYİ MALZEMELERİ İMALAT VE TİCARET A.Ş. OT 020 BENCH TOP STEAM STERILIZER USER S MANUAL

Technical data sheet TDS0070

FLR 1000 & 1000-BR Series Flow Sensors & Meters For Gases

DISSOLVED OXYGEN PROBE

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Testomat AW101 Water Hardness Monitor. A unique water hardness monitoring system with superior performance

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

FILTRATION AMIAD PLASTIC FILTERS, SCREENS & DISCS

SELECTION, APPLICATION AND MAINTENANCE

FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters

BACKPACK SPRAYERS. MODEL NOS: KSP16 & KSP20 Part Nos: & OPERATING & MAINTENANCE INSTRUCTIONS GC04/12

Field and Software Tools

REDOX AND REFERENCE ELECTRODE USER MANUAL

ABV20 Air Actuated Boiler Blowdown Valve Installation and Maintenance Instructions

RayClic Connection System Installation Instructions

3097 en / e. This manual is to be given to the end user POULIBLOC Shaft mount reducer. Installation

Mounting Instructions. Torque Transducer. A en

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

Installation Instructions S

Elektromotoren und Gerätebau Barleben GmbH

Installation and Operating Instructions Installation Instructions for SS EPE-316L Series

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

Milwaukee USER MANUAL

123 Industrial Loop Road Paynesville, MN Phone:

CHEMICAL CLEANING UNIT Product number:

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

INSTALLATION INSTRUCTIONS BL-8704

BPW32 DN15, DN20 and DN25 Balanced Pressure Wafer Steam Trap

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

TEMPERATURE MEASURING GALVANIC SEPARATORS CONVERTORS, PRESSURE MEASURING

Nitrogen, Ammonia. Known Addition ISE Method 1 Method Minimum of 0.8 mg/l NH 3 N. Ammonia ISE. Test preparation. Instrument-specific table

Flat Bottom Long Ram Hydraulic Jack

SCREAMIN' EAGLE "HEAVY BREATHER" PERFORMANCE AIR CLEANER KIT

Precision Miniature Load Cell. Models 8431, 8432 with Overload Protection

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

1. Description. 2. List of Accessories included A B C F G H

POSEIDON 2-29, 2-25 & 2-22 POSEIDON 2-29, 2-25 & 2-22 XT

Subminiature Load Cell Model 8417

AMPSEAL* Automotive Plug Connector and Header Assembly

Duct Humidity Transmitter

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Transcription:

User Guide IM/AP00 Rev. R AP00 series Rugged ph/redox (ORP) sensor systems with rapid temperature response for critical processes

The Company We are an established world force in the design and manufacture of measurement products for industrial process control, flow measurement, gas and liquid analysis and environmental applications. As a part of ABB, a world leader in process automation technology, we offer customers application expertise, service and support worldwide. We are committed to teamwork, high quality manufacturing, advanced technology and unrivalled service and support. The quality, accuracy and performance of the Company s products result from over 100 years experience, combined with a continuous program of innovative design and development to incorporate the latest technology. EN ISO 9001:008 Cert. No. Q 05907 EN 9001 (ISO 9001) Lenno, Italy Cert. No. 9/90A Stonehouse, U.K. Information in this manual is intended only to assist our customers in the efficient operation of our equipment. Use of this manual for any other purpose is specifically prohibited and its contents are not to be reproduced in full or part without prior approval of the Technical Publications Department. Health and Safety To ensure that our products are safe and without risk to health, the following points must be noted: 1. The relevant sections of these instructions must be read carefully before proceeding.. Warning labels on containers and packages must be observed. 3. Installation, operation, maintenance and servicing must only be carried out by suitably trained personnel and in accordance with the information given. 4. Normal safety precautions must be taken to avoid the possibility of an accident occurring when operating in conditions of high pressure and/or temperature. 5. Chemicals must be stored away from heat, protected from temperature extremes and powders kept dry. Normal safe handling procedures must be used. 6. When disposing of chemicals ensure that no two chemicals are mixed. Safety advice concerning the use of the equipment described in this manual or any relevant hazard data sheets (where applicable) may be obtained from the Company address on the back cover, together with servicing and spares information.

AP00 series Contents Contents 1 Description... 1.1 Introduction... 1. Systems... 1..1 Typical Systems... 1.. AP10 Series Electrodes Used with Holders... Mechanical Installation...3.1 Installing the Systems...3.1.1 Model AP01 Insertion System...3.1. Model AP0 Inline System...4.1.3 Model AP03 Flanged Dip (Immersion) System...5. Removing the Sensor Holder...6..1 Models AP01 Insertion and AP0 Inline Systems...6.. Model AP03 Flanged DIp (Immersion) System...7.3 System Assembly...8.4 Jetwash System...9.5 Jetwash System Assembly...10 3 Electrical Installation...11 3.1 Analyzer Connections...11 3. Shortening the Connection Cable...11 3.3 Extending the Connection Cable...1 3.4 Jetwash System Connections...1 4 Calibration... 13 4.1 Method... 13 4. Buffer Solutions... 13 4.3 Redox (ORP Sensor)... 13 5 Maintenance... 14 5.1 General Cleaning... 14 5.1.1 General Sludge and Loosely Adhering Matter... 14 5.1. Heavy, Non-Greasy Deposits... 14 5.1.3 Greasy or Organic Deposits... 14 5. Fault Finding... 14 5.3 Storing the Electrode... 14 6 Specification... 15 7 Spares... 16 7.1 Model AP01 Insertion System... 16 7. Model AP0 Inline System... 17 7.3 Model AP03 Flanged Dip (Immersion) System... 18 Notes... 19 IM/AP00 Rev. R 1

AP00 series 1 Description 1 Description 1.1 Introduction This manual describes the installation and maintenance of the AP00 Series Process ph and Redox (ORP) Electrode Holder Systems. 1. Systems 1..1 Typical Systems AP01 Insertion system AP0 In-line, flow-through system AP03 Dip (immersion) system 1.. AP10 Series Electrodes Used with Holders AP11/11000 General process 0 to 14 ph, 0 to 100 C AP11/1000 High temperature 0 to 14 ph, 0 to 130 C AP11/31000 Low temperature 0 to 10 ph, 5 to +50 C AP11/60000 Redox (ORP) platinum 0 to 100 C See Section 6, page 15 for full details. Insertion System AP01 In-line System AP0 Dip (Immersion) System AP03 Fig. 1.1 System Schematics IM/AP00 Rev. R

AP00 series Mechanical Installation Mechanical Installation.1 Installing the Systems.1.1 Model AP01 Insertion System This system is designed to mount directly into a pipeline or tank. Mounting adaptors are available: 7690 130 PPS Ryton R 1 1 /4 in. adaptor 7690 18 R 1in. Stainless Steel adaptor 7690 134 Polypropylene 1 1 /4 in. NPT adaptor 7690 13 DN5 Straight-weld socket 7690 19 Polypropylene R 1 1 /4 in. adaptor 7690 133 DN5 Angled-weld socket 7690 131 1in. NPT Stainless steel adaptor Dimensions in mm (in.) Pipe-Mount System Tank-Mount System 100 (3.94) 90 (3.54) ø50 37 (1.87) Angled-Weld Socket 15 min. from horizontal Allowable Mounting Position 15 min. 15 min. Note. When installing the Model AP01 insertion system, ensure that the electrode is fully immersed in sample under all operating conditions. Mounting Adaptors G 1 1 /4 G 1 1 /4 G 1 1 /4 G 1 1 /4 50 (1.97) 0 (0.78) 50 (1.97) 18 (0.71) 18 (0.71) 50 (1.97) 40 (1.58) ø5 R 1 /4 or 1 1 /4 NPT 1 in. NPT or R 1in. ø5 ø36 ø5 ø36 7690 130 PPS Ryton R1 1 /4in. Adaptor + 7690 134 PP 1 1 /4in. NPT Adaptor + 7690 19 PP R1 1 /4in. Adaptor 7690 131 1in. NPT Stainless Steel Mounting Adapter + 7690 18 R1in. Stainless Steel Adaptor 7690 13 DN5 Straight-Weld Socket (316 SS) 7690 133 DN5 Angled-Weld Socket (316 SS) Fig..1 Model AP01 Insertion System IM/AP00 Rev. R 3

AP00 series Mechanical Installation.1. Model AP0 Inline System This system is supplied with an inline tee-piece for mounting the system directly into a pipeline. Allow sufficient height above the system to enable the sensor to be withdrawn from the tee-piece. Dimensions in mm (in.) Minimum clearance required Rp 1 in. Female Threads 67.5 (.66) (Stainless Steel versions only) Note. Refer to Section 6, page 15 for information about the different versions. (Polypropylene versions only) To prevent spillage when system is removed To ensure electrode is always in sample Isolating Valve Isolating Valve Typical Installation Fig.. Model AP0 Inline System 4 IM/AP00 Rev. R

AP00 series Mechanical Installation.1.3 Model AP03 Flanged Dip (Immersion) System This system is designed to be installed over an unpressurized tank or channel. A sliding flange is supplied to enable adjustment of the immersion depth. A suitable mounting bracket or support must be supplied by the user. Dimensions in mm (in.) 100 (3.94) 90 (3.54) 74 (.91) Thumb-screws (see Note below) ø50 Insert 1, or 3 m (39.37, 78.74, 118.11) ø56 Mounting Flange Dimensions Note. Ensure the thumb-screws compress the insert when clamping the flange to the dip tube. Mounting bracket supplied by user Typical Installation Fig..3 Model AP03 Flanged Dip (Immersion) System IM/AP00 Rev. R 5

AP00 series Mechanical Installation. Removing the Sensor Holder..1 Models AP01 Insertion and AP0 Inline Systems Open cover and detach cables and jetwash tubing (if fitted) from cap 1 Twist cable shroud counter-clockwise and remove Unscrew sensor holder retaining nut and remove sensor holder from in-line adaptor 3 Check O-ring is in position, located on underside of electrode holder 4 AP01 AP0 Fig..4 Models AP01 and AP0 Removing the Sensor Holder 6 IM/AP00 Rev. R

AP00 series Mechanical Installation.. Model AP03 Flanged DIp (Immersion) System Open cover and detach cables and jetwash tubing (if fitted) from cap 1 Unscrew sensor guard from dip tube (see Note below) Note. Before refitting the sensor guard, clean and regrease the threads and O-ring. Do not overtighten the sensor guard. Remove the sensor holder from the dip tube using the sensor guard as a tool. Engage the sensor guard lugs in the sensor holder slots. Twist the sensor holder counter-clockwise to disengage the bayonet lugs from the slots in the dip tube and withdraw the sensor holder. Ensure the O-ring remains clean. 3 Fig..5 Model AP03 Removing the Sensor Holder IM/AP00 Rev. R 7

AP00 series Mechanical Installation.3 System Assembly 11 Close cover Note. Model AP01 shown. When assembling Models AP0 and AP03, refit the Tee piece to the sensor holder (AP0) or the sensor guard to the dip tube (AP03) see Figs..4 and.5. 10 Clip cables and jetwash tube (if required) into slots in protective cover 1 Route cables and jetwash tube (if required) through cable shroud 9 Locate cable shroud over sensor holder and twist clockwise to engage bayonet lugs in slots 3 Insert sensor in holder Ensure support washer and O-ring are fitted to electrode 4 Tighten 6 Tighten to recommended torque value of 15cNm Locate sensor cable connector over keyway 5 8 Connect earth (ground) terminal to rod 7 Connect jetwash supply tube (if required see Section.5, page 10) and tighten to recommended torque value of 60cNm Fig..6 System Assembly 8 IM/AP00 Rev. R

AP00 series Mechanical Installation.4 Jetwash System Note. Installation must be carried out in accordance with local water company and council bylaws. Cleaning Solutions The spray jet tube is available in 316 stainless steel. Some typical cleaning solutions are: The jetwash system enables automatic cleaning of both the measuring element and the reference junction by spraying either water or a cleaning solution at them in situ, thus reducing system maintenance requirements. An external pump or solenoid valve is required, controlled by a ph analyzer with auto-cleaning control functions. Note. For optimal performance, the pressure of the jetwash system should be to 3 bar (30 to 45 psi) greater than the process pressure. Coating Grease and Oils Resins Limestone/Carbonates Metal hydroxides Cyanides Heavy biological Cleaning Agent Alkaline detergents or water-soluble solvents such as alcohols Dilute alkalis 1M nitric acid 1M sulphuric or nitric acid Proteins Mixture of 1M sulphuric or nitric acid and pepsin (saturated) Mains water or Pressurized cleaning solution Solenoid Valve OR Transmitter with autoclean relay contact Fibres Pressurized water with or without wetting agents Light biological Latex (see Note below) Pressurized water Pressurized cold water Note. If removed from the process the latex must be completely removed quickly before it hardens. Pump Use a nonreturn valve to maintain optimum performance Reservoir (water or cleaning solution) Fig..7 Typical Jetwash Installation Maintenance Cleaning Screw Twin Wash Nozzles Fig..8 Location of Jetwash Nozzle IM/AP00 Rev. R 9

AP00 series Mechanical Installation.5 Jetwash System Assembly The system is supplied with a blanking plug fitted to the jetwash tubing connector. If the jetwash system is to be used, remove the plug and fit the jetwash supply tube as shown in Fig..9. Note. Recommended tubing is 6mm OD semi-rigid polyethylene tube (part no. 01035). Remove jetwash port sealing nut and retain for further use (See Note below) 1 Note. The seal nut must be fitted when the jetwash tubing is not being used. Slide connector onto tubing 3 4 Slide ferrule onto tubing Push tubing onto jetwash port, screw connector onto jetwash port and tighten to recommended torque of 60cNm Fig..9 Fitting Jetwash Supply Tubing 10 IM/AP00 Rev. R

AP00 series 3 Electrical Installation 3 Electrical Installation 3.1 Analyzer Connections System cable connections are identified in Fig. 3.1 to enable connection to the appropriate terminal on the analyzer. ph A B C D E F G White Green Grey Blue Transparent Red Green/yellow 3. Shortening the Connection Cable The connection cable is supplied in various standard lengths. If it is necessary to shorten the cable, prepare the cable ends as shown in Fig. 3.. The cable comprises: 1. an outer insulating layer. an inner braided shield 3. a shielded coaxial core 4. four insulated wires Note. Do not allow the shielding to contact any other bare wires. Fig. 3.1 Cable Termination Key A Temperature A B compensator B C C D Reference electrode E Measuring electrode F Screen G Solution earth (see Note below) Note. The sensor is equipped with a solution earth (ground) which is designed to provide full sensor diagnostics when connected to a suitable analyzer. If sensor diagnostics are not required, it is not necessary to connect the solution earth (ground). Redox (ORP) Key A Measuring electrode B Reference electrode Note. Cut off and discard remaining unused cores. A B Transparent Blue 80 mm (3.15 in.) 35 mm (1.38 in.) Measure the required length from connector to transmitter and cut accordingly. Slit open and trim away the outer cable insulation to expose braiding. Undo the braiding along the complete exposed length and twist into a single strand. Shorten the twisted strand to about 5mm (0.0 in.) and solder on the insulated ground lead extension (70mm [.76 in.], yellow/green). Protect the connection with insulating tape. Slit open and trim away the insulation of the coaxial core. a) Undo the exposed braided shielding and twist into a single strand. b) Remove the black semiconductor layer to expose the ph signal conductor. a) Strip away the insulation from the ends of the leads over a length of 10mm (0.39 in.) and fit end sleeves on the individual wires. b) Fit a heat-shrink sleeve or insulating tape over the cable end where the cable leads emerge. Fig. 3. Shortening the Connection Cable IM/AP00 Rev. R 11

AP00 series 3 Electrical Installation 3.3 Extending the Connection Cable If it is necessary to extend the cable, a suitable junction box and the correct length of 6-core cable are required. Connect the junction box as shown in Fig. 3.3. Note. Junction box (part no. 7690/049) is recommended. 6-core cable, part no, 7690054/XX (where XX is the cable length, from 5 to 50 meters, in 5 meter increments) is recommended. Cable 7690054 is identical to that fitted to the sensor. See Fig. 3. for cable end preparation instructions. Cable from AP00 Sensor or Detachable Cable see Table 3.1 Cable Length Part Number 5 m (16 ft) 7690050 10 m (33 ft) 7690051 15 m (49 ft) 769005 0 m (60 ft) 7690053 Table 3.1 Detachable Cables 3.4 Jetwash System Connections The electrical supply to the jetwash system pump or solenoid valve is connected to the analyzer relay used for automatic cleaning see Fig. 3.4. The analyzer controls the frequency of the wash sequence and the duration for which the cleaning solution flows. The analyzer outputs are held during a cleaning sequence. Solenoid Valve Transmitter Auto Clean Relay Contact OR Pump N/O C Green Green White White Grey Grey Blue Blue Green/Yellow Green/Yellow Transparent Transparent Red Red Fig. 3.4 Electrical Connections for Jetwash Systems Junction Box Pt No. 7690/049 Extension Cable (Pt No. 7690054/XX) to Analyzer Fig. 3.3 Extending the Connection Cable 1 IM/AP00 Rev. R

AP00 series 4 Calibration 4 Calibration 4.1 Method When the electrode system has been correctly connected and all electrical connections made to the associated ph analyzer, the system is ready for calibration by immersing the sensor (using suitably sized beakers) either: 1. in a calibration solution (buffer) of known ph value for a single-point calibration, or. in two separate calibration solutions of known ph values for a two-point calibration. For sensors already in use: 1. Remove the electrode from the process or sample.. Wash the visible electrode surface with demineralized water. 3. Proceed as described in the paragraph above. To have agreement with a measured sample, there may be times when a process calibration is necessary. 1. Perform a buffer calibration.. Ensure that the electrode is returned to the process for at least 10 minutes before performing a process calibration. 3. To minimize solution temperature effects, measure the sample at the same temperature as the process. Refer to the instruction manual for the ph analyzer for full details of the calibration procedures. Warning. Close all isolating valves before removing an electrode from a flow line. 4. Buffer Solutions Recommended buffer solutions are shown in Table 4.1. Buffer Solution Part No. 4pH 0.05M potassium hydrogen phthalate 0400 110 7pH Disodium hydrogen phosphate/monopotassium dihydrogen phosphate mix 0400 10 9pH 0.05M borax 0400 130 Table 4.1 Recommended Buffer Solutions Note. Ensure that the visible surface of the electrode has been cleaned using demineralized water. When moving from one buffer solution to the next, wash the electrode using demineralized water and dry it carefully using a soft tissue. Table 4. shows the change in ph value that occurs with a change in the temperature of the recommended 4, 7, and 9 ph buffer solutions. C ph 0 10 0 5 30 40 50 60 70 80 90 4 4.00 4.00 4.00 4.01 4.01 4.03 4.05 4.08 4.1 4.16 4.1 7 7.11 7.06 7.01 7.00 6.98 6.97 6.97 6.97 6.99 7.03 7.08 9 9.48 9.35 9.3 9.18 9.13 9.05 8.98 8.93 8.90 8.88 8.84 Table 4. Buffer ph Value / Temperature ( C) 4.3 Redox (ORP Sensor) When the sensor has been correctly connected and all electrical connections have been made to the associated Redox (ORP) analyzer, it is ready for calibrating. Follow the calibration procedure in the analyzer User Guide. For sensors that are connected to analyzers that do not have Redox (ORP) sensor calibration capabilities, it is possible to check the response as follows: 1. Prepare standard 4 and 7 ph buffer solutions. Add one gram (heaped spatula) of analar quinhydrone to 100 ml (3.5 Flu oz.) of each buffer solution. Let them stand for 30 minutes.. Immerse the sensor in each solution in turn and note the mv value when stable. The values obtained should be within ±15 mv of the following: ph Buffer mv 4 +59 7 +8 IM/AP00 Rev. R 13

AP00 series 5 Maintenance 5 Maintenance 5.1 General Cleaning Warning. Close all isolating valves before removing an electrode from a flow line. To ensure accurate monitoring, keep the electrodes free of contaminants by periodic cleaning. The frequency of cleaning depends on the particular application. Automatic cleaning using the optional jetwash system and controlling the cleaning solution using a suitable controller or analyzer, will reduce the amount of manual cleaning. Methods of removing various types of deposit are detailed below. Replace the sensor if the performance of the sensor does not improve after cleaning. 5.1.1 General Sludge and Loosely Adhering Matter Rinse off the excess matter and wipe the sensor with a soft cloth or tissue before calibrating. 5.1. Heavy, Non-Greasy Deposits For example: lime, salts, etc. Immerse the sensor in 1 to M hydrochloric acid until the deposit has dissolved. Rinse with demineralized water before calibrating. 5.1.3 Greasy or Organic Deposits Wipe the glass membrane with a detergent or acetone-based solvent. Rinse with demineralized water before calibrating. 5. Fault Finding Listed below are some common symptoms of sensor malfunction together with possible cures. Short scaling (Low Slope) or sluggish response 1. Glass sensor membrane dirty or coated refer to Section 5.1 for cleaning.. Poor insulation on cable connectors, possibly due to moisture dry connectors with warm air. Replace sensor if no improvement is seen. (It may also be necessary to replace the extension cable if used.) No response to ph buffer or sample 1. Sensor incorrectly connected see Section 3.1, page 11 and the analyzer user guide for connection details.. Glass sensor membrane broken or cracked replace sensor. Unstable readings or drift 1. Sensor incorrectly connected see Section 3.1, page 11 and the analyzer user guide for connection details.. Dry or dirty reference junction clean junction as detailed in Section 5.1. Leave to soak in a buffer solution for several hours. Replace sensor if no improvement is seen. Stable but incorrect readings 1. Incorrect calibration recalibrate using fresh buffer solutions.. Incorrect temperature compensation settings enter correct manual temperature or check that automatic temperature compensation is reading correctly. 3. Sensor responds correctly to ph changes, but there is an offset of <1.0 ph and >0. ph perform a one-point process calibration see Section 4.1, page 13. Note. All the above symptoms could be caused by a faulty extension cable. Check and replace it, if necessary. 5.3 Storing the Electrode Note. Allowing the glass membrane and reference junction to dry out irreversibly affects the response of the electrode. If it is necessary to remove the electrode from the sample line, fill the retained protective cap with buffer solution and cotton wool, or equivalent, and fit it to the sensor. 14 IM/AP00 Rev. R

AP00 series 6 Specification 6 Specification All Systems Materials AP03 Immersion (Dip) System Materials Shaft and cap Sensor body Ground rod/spray tube Jet-wash facility Non-return function Spray tube connection Recommended operating pressure Polypropylene Ryton PPS 316 Stainless steel Integral one-way valve 6mm compression fitting Min. 1 bar (15 psi) over process pressure Certification The systems comply with SEP (Safe Engineering Practice) level Pressure Equipment Directive 9713/EC Guard, shaft and cap Maximum Temperature 90 C (194 F) Maximum Pressure Not applicable Process Connections Sliding flange Immersion lengths Polypropylene Composite DIN & ANSI DN50 / ANSI in. 1 m (3.3 ft) m (6.6 ft) 3 m (10 ft) AP01 Insertion System Maximum Temperature 130 C (66 F) PPS and steel adapters 90 C (194 F) Polypropylene adapter Maximum Pressure 6 bar (90 psi) @ 5ºC (77ºF) Process Connections Union nutg PPS process adapter PP process adapters Stainless steel adapters Stainless steel sockets AP0 Flow-through System Materials Flow-cells Maximum Temperature 1 1 /4 in. (BSP) R1 1 /4 in. (tapered BSP male) R1 1 /4 in. 1 1 /4 in. NPT R1 in. (tapered BSP male) 1 in. NPT Angled DN5 Straight DN5 Polypropylene Stainless steel AP10 Combination Sensor Measuring Ranges AP11/0 General Process 0 to 14 ph 0 to +100 C (3 to 1 F) AP11/1 High Temp/Alkali 0 to 14 ph 10 to 130 C (50 to 66 F) AP11/ Low Resistance 0 to 10 ph 5 to 50 C (3 to 1 F) AP11/6 Pt Redox (ORP) ± 000mV 0 to 130 C (3 to 66 F) Reference Electrode System Primary Electrolyte Inner reference system JunctionAnnular Nominal zero point, E0 Minimum Conductivity General Data Solid, Ag-free Gel with KCl charge Ag/AgCl PTFE, sterilizable 7 ph > 50 µs/cm Temperature Sensor (ph only) Integral Pt100 Temperature response T90 <70s Electrode Shaft Length 10 mm Max. Pressure 6 bar (90 psi) Ingress Protection IP67/NEMA 6P (exceeds NEMA4X) Connection head Sterilizable VP (VarioPin) connector with PG13.5 thread DS/AP00 EN Rev. I 90 C (194 F) Polypropylene flow cell 130 C (66 F) Stainless steel flow cell Maximum Pressure 6 bar (90 psi) @ 5ºC (77ºF) Process Connections Union nut Flow-cell inlet & outlet G1 1 /4 in. (BSP) Rp1 in. (BSP female) or 1 in. NPT IM/AP00 Rev. R 15

AP00 series 7 Spares 7Spares 7.1 Model AP01 Insertion System 11 10 7 9 6 * 8 5 4 * * 3 1 * Fitted on water wash option only Fig. 7.1 Model AP01 Insertion System Spares Item Part No. Description Qty 1 7690130 1 1 /4 in. BSP Adaptor 1 5** 7690043 Sensor Holder (non water wash only) 1 or 7690041 or Sensor Holder (water wash only) 8 7690160 Cable Shroud 1 9 769018 Protective Cover Adaptor Sleeve 1 0 7690140 Protective Cover 1 k 7690145 Protective Lid 1 ** Comprises items, 3 and 4 Item Part No. Description Qty * 3* 4 6 7 7690040 Service Pack Comprising: Cleaning Screw (water wash only) O-Ring 3 mm ID x 1.5 mm CH Viton (water wash only) O-Ring 1 1 /16 in. ID x 0.103 in. CH Viton O-Ring 11.6 mm ID x.4 mm CH Viton O-Ring Support Washer 1 The following are also supplied in the Service Pack but not used on the AP01 Insertion System: O-Ring 37.77 mm ID x.6 mm CH Viton O-Ring 46 mm ID x mm CH Viton * Fitted on water wash option only 16 IM/AP00 Rev. R

AP00 series 7 Spares 7. Model AP0 Inline System 1 11 8 7 * 10 6 9 5 * * 3 4 1 * Fitted on water wash option only Fig. 7. Model AP0 Inline System Spares Item Part No. Description Qty 1 7690150 Tee-piece 1 7690130 1 1 /4 in. BSP Adaptor 1 6** 7690043 Sensor Holder (non water wash only) 1 or 7690041 or Sensor Holder (water wash only) 9 7690160 Cable Shroud 1 0 769018 Protective Cover Adaptor Sleeve 1 k 7690140 Protective Cover 1 l 7690145 Protective Lid 1 ** Comprises items 3, 4 and 5 Item Part No. Description Qty 3* 4* 5 7 7690040 Service Pack Comprising: Cleaning Screw (water wash only) O-Ring 3 mm ID x 1.5 mm CH Viton (water wash only) O-Ring 1 1 /16 in. ID x 0.103 in. CH Viton O-Ring 11.6 mm ID x.4 mm CH Viton 1 8 O-Ring Support Washer The following are also supplied in the Service Pack but not used on the AP0 Inline System: O-Ring 37.77 mm ID x.6 mm CH Viton O-Ring 46 mm ID x mm CH Viton * Fitted on water wash option only IM/AP00 Rev. R 17

AP00 series 7 Spares 7.3 Model AP03 Flanged Dip (Immersion) System 14 13 1 8 7 6 * 11 10 5 4 * * 3 9 1 * Fitted on water wash option only Fig. 7.3 Model AP03 Flanged Immersion (Dip) System Spares Item Part No. Description Qty 1 769010 Protective Skirt 1 4 769004 Sensor Holder 1 9 76901 Non-Seal Flange 1 j 7690044 Scalloped Knob spare M5 x 15 mm (pack of ) 1 k 769013 Ind Dip Flange Insert 1 l 769018 Protective Cover Adaptor Sleeve 1 m 7690140 Protective Cover 1 n 7690145 Protective Lid 1 Item Part No. Description Qty * 3* 7690040 Service Pack Comprising: Cleaning Screw (water wash only) O-Ring 3 mm ID x 1.5 mm CH Viton 1 (water wash only) 5 6 7 8 O-Ring 37.77 mm ID x.6 mm CH Viton O-Ring 46 mm ID x mm CH Viton O-Ring 11.6 mm ID x.4 mm CH Viton O-Ring Support Washer The following is also supplied in the Service Pack but not used on the AP03 Flanged Immersion (Dip) System: O-Ring 1 1 /16 in. ID x 0.103 in. CH Viton * Fitted on water wash option only 18 IM/AP00 Rev. R

AP00 series Notes Notes IM/AP00 Rev. R 19

AP00 series Notes 0 IM/AP00 Rev. R

Products and customer support Automation Systems For the following industries: Chemical & Pharmaceutical Food & Beverage Manufacturing Metals and Minerals Oil, Gas & Petrochemical Pulp and Paper Drives and Motors AC and DC Drives, AC and DC Machines, AC Motors to 1kV Drive Systems Force Measurement Servo Drives Controllers & Recorders Single and Multi-loop Controllers Circular Chart and Strip Chart Recorders Paperless Recorders Process Indicators Flexible Automation Industrial Robots and Robot Systems Flow Measurement Electromagnetic Flowmeters Mass Flowmeters Turbine Flowmeters Wedge Flow Elements Marine Systems & Turbochargers Electrical Systems Marine Equipment Offshore Retrofit and Refurbishment Process Analytics Process Gas Analysis Systems Integration Transmitters Pressure Temperature Level Interface Modules Valves, Actuators and Positioners Control Valves Actuators Positioners Water, Gas & Industrial Analytics Instrumentation ph, Conductivity and Dissolved Oxygen Transmitters and Sensors Ammonia, Nitrate, Phosphate, Silica, Sodium, Chloride, Fluoride, Dissolved Oxygen and Hydrazine Analyzers Zirconia Oxygen Analyzers, Katharometers, Hydrogen Purity and Purge-gas Monitors, Thermal Conductivity Customer support We provide a comprehensive after sales service via a Worldwide Service Organization. Contact one of the following offices for details on your nearest Service and Repair Centre. UK ABB Limited Tel: +44 (0)1453 86661 Fax: +44 (0)1453 89671 USA ABB Inc. Tel: +1 15 674 6000 Fax: +1 15 674 7183 Client Warranty Prior to installation, the equipment referred to in this manual must be stored in a clean, dry environment, in accordance with the Company's published specification. Periodic checks must be made on the equipment's condition. In the event of a failure under warranty, the following documentation must be provided as substantiation: A listing evidencing process operation and alarm logs at time of failure. Copies of all storage, installation, operating and maintenance records relating to the alleged faulty unit.

Contact us ABB Limited Process Automation Oldends Lane Stonehouse Gloucestershire GL10 3TA UK Tel: +44 1453 86 661 Fax: +44 1453 89 671 ABB Inc. Process Automation 15 E. County Line Road Warminster PA 18974 USA Tel: +1 15 674 6000 Fax: +1 15 674 7183 Note We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB. Copyright 014 ABB All rights reserved IM/AP00 Rev. R 07.014 www.abb.com