KLEIN UTILITY TOOLS & MISC.



Similar documents
758 Heavy-duty Ratchet Guy Wire Cutter

Cutting and stripping tools

PART 1 - INTRODUCTION...

Application Tooling Specification Sheet

162 CB CABLE TRACER. Filter Probe & Tone Generator INSTRUCTION MANUAL

71

Reasons for reissue of this instruction sheet are provided in Section 5, REVISION SUMMARY.

Wire Pulling Grips. Wire Pulling Grips

Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

OSHA Remove impacted systems and components. Inspect systems prior to use.

RAILWAY CATENARY SYSTEMS. Components and Systems for the Electrification of Railway Lines. ibemo

Horizontal Lifeline. SideWalk Rope. User Instructions. 3M Occupational Health and Environmental Safety. Fall Protection Equipment

Shunt lock function 3066

Super Slider ADJUSTABLE FROM Model #HD26229

SAFE HANDLING OF PRECAST CONCRETE PRODUCTS

5-Other arc welding WELDING TOOLS AND ACCESSORIES

VERTICAL / FIXED BEAM CLAMP I-BEAM ANCHOR ADJUSTABLE FROM 4-14 Model # HD26249

5.2. Overview. The better method to install solderless compression connectors on power cable

User Instruction Manual Vertical Lifelines and Vertical Lifeline Subsystems

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

UT202A Operating Manual. Contents

Using Klein Tools Chicago Grips in Common Overhead Applications

Voltage Detection and Indication by Electric Field Measurement

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Electrical Safety Products

RAUFOSS EXPLOSIVE COMPRESSION FITTINGS

The load carrier system designed for professionals

Power Supply Cables and Connectors

MESSENGERS FOR AERIAL CABLE

LiftAlloy Chain Slings

Digital Ground Resistance Tester. Models 4620 & Digital Ground Resistance Tester

MCR1900 Media Converter 19-Slot Chassis

TENSIONMETER ** code 183_LNRSTW **

12 Volt 30 Amp Digital Solar Charge Controller

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

How To Read A Pipe From A Sensor

Wire Pulling Grips. Wire Pulling Grips. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

The Campbell operation facilities in York, PA, and Cortland, NY, conform to Quality Standard ISO 9001.

Working at Heights and Fall Protection

BAGGAGE HANDLING SYSTEMS. Trastecnica S.p.A. Handling Baggage Systems Edition Rev

Wire Rope Extender Lanyard

English. Symbols used to mark instructions...3. Congratulations...5 Getting the best results...5. Warnings...6 Operating Procedure...

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

HAND CRIMP TOOL Specification Sheet Order No

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

OPERATING INSTRUCTIONS

ACL 395 Resistivity Meter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

TECHNICAL SPECIFICATION FOR HIGH TENSION LINE HARDWARE AND ACCESSORIES FOR ACSR PANTHER & WOLF CONDUCTOR

EMPLOYEE FALL PROTECTION

Implosive Connectors. for overhead transmission lines

Operations and Instruction Manual Might Swivel - Part # Concrete and Steel Anchorage Connector ANSI Z ,000 lbs / 44kn

GUY-GRIP Dead-end NOMENCLATURE GENERAL INFORMATION SAFETY CONSIDERATIONS (440)

User Guide. Model Insulation Tester / Megohmmeter

Cable-Gard Static Discharge Reels

User s Manual. Copyright 2014 Trick Technologies Oy

ELECTRIC KNIFE SHARPENER

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal T [] C

HYDRAULIC LIFT TABLE CART 2200-LB.

RATCHET RELEASE SHACKLE

12 Volt 30 Amp Digital Solar Charge Controller Installation & Operation Manual

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

uline.com SPECIFICATIONS

Ground Resistance Clamp On Tester

IEEE POWER ENGINEERING SOCIETY CHICAGO CHAPTER THE OKONITE COMPANY WEDNESDAY JANUARY 11, 2006 JIM FITZGERALD ENGINEERING LINGO

ToolLasso System. StepladderAccessories. Load Capacity TL2BC-20 TL2BC-12 TL50 TL5-20 TL5-12

Series 8146/5-V37 and Series 8150/5-V37

SERVICE GUIDE For WARN PULLZALL 120v AC &100v AC P/N &

FIBREGLASS LADDERS THE LADDER WITH THE BLUE TRIM

[see Figure 3 below] Ferrite tile walls and ceiling RF Absorber parcel walls and ceiling Removable floor section to make fully anechoic

PowerLine Magnetic-Laser Pulley Alignment System Instructions

IMPORTANT DOCUMENTATION DO NOT DISCARD!

Portable Ladder Safety

12-Volt 10-Amp Regulated Power Supply

TBM5, TBM5-S and TBM5-SV

2016 Spring Fall Protection Construction Products

BETA Protecting SITOR Semiconductor Fuses

Fall Protection Guidelines

Machine Safety Switch: SI-LM40 Series Limit Switch Style

Connect. Cable preparation and cutting tools

LOXONE 12 Channel Amplifier

ACTIV-8 PLUS Insulated Conductor Bar

ATL Fuel Level Sender Probes

SSW-iLM Keypad. Wire Harness Configuration. Note: This product is designed to be installed and serviced by security and lock industry professionals

PowerLine Magnetic-Laser Sheave Alignment System Instructions

Survival Laser SL-001BB Laser Parts Bundle Assembly & Operation Instructions

Transformer Bushings for GIS

Model WH20 User Guide

RIGGING HARDWARE ASME B Addresses detachable lifting hardware for lifting purposes

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

Trillium 40 Axis Spring Tensioner Wire Replacement Instructions

Elkhorn Construction, Inc. Safety Manual Title: Fall Protection Policy Effective Date:

Auto-belay Cable Replacement Process

AMPSEAL* Automotive Plug Connector and Header Assembly

Transcription:

July 2015 Utilities

2

Contents Chicago Grips Parallel Jaw Grips Haven Grips 4 4 4 Cable Tensioning Tools Tool Pouches Canvas Buckets Voltage Detectors Wrenches Information, Care and Maintenance 5 6 6 7 8 9 3

Grips CHICAGO GRIPS Hamer Klein KE250 1656-20 Cable Application Jaw Shape Cable Specifications External Ø Range (inches) External Ø Range (mm) Max Safe Load (kg) 0.20-0.40 5.08-10.16 2045 KE260 1656-30 Copper (stranded) 0.31-0.53 7.87-13.46 2045 or aluminium ACSR 0.53-0.74 13.46-18.80 Ο KE270 1656-40 3636 KE280 1656-50 0.74-0.86 18.80-21.84 3636 KE170 1613-40 0.12-0.37 3.05-9.40 2045 K80 1684-5 Extra high-strength 0.22-0.55 5.54-13.97 3636 cables or guy KE220 1628-16 strands 0.31-0.62 7.87-15.75 6818 KE230 1628-17 0.50-0.75 12.70-19.05 6818 K00 1659-20 PVC covered 0.20-0.42 5.08-10.67 2045 Ο K30 1659-50 conductor 0.79-1.01 20.07-25.65 3636 KE160 1613-30 Small bare cables 0.08-0.2 2.03-5.08 680 PARALLEL JAW GRIPS Hamer Klein Cable Application Jaw Shape Cable Specifications External Ø Range (inches) External Ø Range (mm) Max Safe Load (kg) K95 1685-20 PVC covered 0.16-0.87 4-22 2045 Ο KE400 * 1685-31 or bare cable 0.63-1.26 16-32 3409 * Available on request only HAVEN GRIPS * Hamer Klein Cable Application External Ø Range (inches) Cable Specifications External Ø Range (mm) Max Safe Load (kg) KE140 1604-20 Steel strand 0.13-0.50 3.18-12.70 2272 KE180 1625-20 Wire rope 0.28-0.75 7.11-19.05 3636 * Use where conductor damage is not a factor. 4

CABLE TENSIONING TOOLS Hamer Klein Description KE110 1702-20N Howe wire tool, 25mm nylon webbing strap with swivel hook 227 Kg max safe load KE1350 KN1500P-EX Web-strap ratchet hoist 680 to 1361 Kg max load rating K90 KE490 H1802-30S H1802-30S SR Block & tackle (supplied with 259 swivel anchor hook, block with guarded snap hooks, 25 rope & block with guarded snap hook with eye for rope tie-off ) Block & tackle (supplied with 259 swivel anchor hook, block with guarded snap hooks & block with guarded snap hook with 25 spliced rope attached to eye) KE110 K90 KE1350 5

TOOL POUCHES Hamer Klein KL4985 5178 KL4990 5167 Description 8 pocket tool pouch made from soft, pliable white leather. Riveted and stitched for extra durability. Tunnel loop belt connection. Belt width 64mm, overall size 279mm x 254mm. 11 pocket tool pouch, made from soft, pliable leather. Moisture resistant, riveted and stitched. Slotted belt connection. Belt width 70mm, overall size 254 mm x 267mm. KL4985 CANVAS BUCKETS WITH POLYPROPELENE BOTTOMS KL4990 Hamer Klein Description KE5113 5113 #6 Canvas Tapered Wall 305mm Ø to 229mm Ø x 330mm H KE5113S 5113S #6 Canvas Tapered Wall with Swivel Snap 305mm Ø to 229mm Ø x 330mm H KE5103S 5103S #4 HD Canvas Tapered Wall with Swivel Snap 305mm to 229mm Ø x 330mm H KE5109S KE5109PS 5109S 5109PS #6 Canvas Wide-Opening Straight-Wall with Swivel Snap 305mm Ø x 381mm H Load rated to 34Kg max #6 Canvas Wide-Opening Straight-Wall 1 Int. Pocket with Swivel Snap 305mm Ø x 381mm H Load rated to 34Kg max KE5171PS 5171PS #4 HD Canvas Tapered Wall 305mm to 229mm Ø x 305mm H & 4 Ext. Pockets KE5172PS 5172PS #4 HD Canvas Tapered Wall 305mm to 229mm Ø x 305mm H & 15 Int. Pockets KE5113 KE5103S KE5171PS KE5172PS Canvas Weights Info. 1 = Thickest, 8 = Thinnest KE5109S 6

VOLTAGE DETECTOR Hamer PET4000 Description V-Watch Personal Voltage Detector VW-20H with carry case Worn on the outside of your clothing at mid-torso, the V-Watch provides that extra level of safety by detecting and alerting you to the presence of electrical fields or energized electrical equipment. In emergencies, you and your crews can move safely to quickly restore power to your customers. The V-Watch comes in a tough nylon carrying case lanyard that is worn around the neck during use. The C-10 Carrying Case Lanyard is made with a black shielded material. Features and Benefits Alerts user to proximity of high voltage Audible and visual alarms increase in frequency the closer the user gets to energized equipment Typical V-Watch initial warning distance is about 7 feet (2.13 m) from a 4kVAC conductor (see instruction manual for more details). Warning distance increases with higher voltages. Provides another level of safety for line crews, storm restoration workers and first responders Low battery indicator Field replaceable 9V battery Rugged protective housing Built-in self test Lightweight Carrying case lanyard Black shielded nylon material Electrically shielded Storage case when the V-Watch is not in use Lanyard allows user to adjust to optimum mid-torso position Comes supplied with the black C-10 carry case pictured. Specifications Sensitivity: Factory Set at 50/60 Hertz sensing threshold (first beep). The V-Watch will only detect AC voltage. Do not use below 2400 Volts line-to-ground. Typical Warning Distance: About 7 feet (2.13 m.) from a 4kV (2.4kV line-to-ground) AC conductor. Operating Temperature: -20 to +120 F (-29 to 49 C) Operating Frequency: 50Hz/60Hz Battery: 9V alkaline 1604A, IEC 6LR61. Life is 2 years in storage, 1 year typical usage. Beeper Sound Pressure Level: 100 decibels Water Withstand: Protected from falling rain per IEC-529, Level 2 Weight (with battery): 5.2 oz. (147 g.) Dimensions: 3.5 x 2.88 x 1.25 (8.89 cm. x 7.32 cm. x 3.18 cm.) Voltage Range: 2400VAC line-to-ground and above MODIEWARK Hamer MWB0033 MWB0022 Description The Modiewark detects the presence of an alternating electric field. Its unique switching action allows identification of A.C. voltage levels from 110v to 330,000 volts. Also available on request: VRS Modiewark version capable of testing 240V, 1KV, 2.2KV, 6.6KV, 11KV and 22KV MWB0011 Modiwark Sunrise Replacement Handle MWB0011 7 MWB0033

Podgy Ratchet Wrench Hamer Description Sizes 18mm PET1317 Ratchet Wrench 13mm / 17mm PET1824 Ratchet Wrench 18mm / 24mm PET1924 Ratchet Wrench 19mm / 24mm 24mm (other side) Other sizes available on indent order: Hamer Description Sizes PET1921 Ratchet Wrench 19mm / 21mm PET2124 Ratchet Wrench 21mm / 24mm PET2430 Ratchet Wrench 24mm / 30mm Ratcheting Construction Wrench Hamer Supplier Description KL2657 3238 1/2" square drive Ratcheting Wrench Adj. Construction Wrench Hamer Supplier Description KL2658 3239 Adjustable-head Construction wrench Max size capacity 38mm 8

FORGED STEEL GRIPS Klein Chicago and Haven Grips are used to pull wire and cable, and to maintain temporary tension until the cable can be permanently terminated. These grips are not to be used as anchors. Klein Chicago grips have locking loop handles, standard on most grips that allow the jaws to be held in an open position for easier placement on wire or cable. This saves substantial time, and makes grip positioning easier than with wedge or bolt-on designs. To lock, open the jaws and fold loop handle toward the side plates. HOW TO SELECT THE PROPER GRIP Three basic factors determine the selection of the proper grip for each specific application: Type of wire or cable. Outside diameter of wire or cable. Maximum safe load required. Also the correct type of inside jaw contour should be considered. It is essential to select the correct gripping jaws to avoid damage to the wire or cable. When pulling stranded wire, the jaws should be long enough to take a full lay of cable to avoid damage to the conductor. Inside-Jaw Contours: Each grip comes with one of three inside-jaw contours appropriate for the type of wire or cable to be worked. Single V: Simple three-point contact jaws are designed for use on small-diameter bare wire and cable (solid stranded). Double V: Four-point contact provides greater gripping pressure and assures proper alignment of wire and cable within the jaws. Designed for high-strength steel guy wire and messenger wire, and extrahigh-strength cables and conductors. Round: Round jaws provide maximum contact and gripping power to minimize conductor damage. This jaw design is recommended for use on bare aluminium, ACSR, and copper conductors. REPAIR OR REPLACE? Never repair any grip. Grip jaws can sometimes be replaced if the grip is returned to Klein, but structural wear or damage cannot be safely corrected. Grips that are bent, misaligned or otherwise distorted should be discarded and replaced. Before each use, check all grips for jaw condition, proper alignment of jaws and all parts, and possible distortion caused by exceeding safe-load specifications. Grips should operate smoothly. Spring-loaded grips should lock open with loop handle in Down position and should close automatically with loop handle Up. The Klein parallel jaw grip may be tested by opening and closing the jaws by hand, while exercising proper caution. All parts and rivets, which may be distorted due to exceeding safe load, should be checked. RECOMMENDED CARE & MAINTENANCE The following guidelines have been established in order to maintain all grips in good condition: Clean the Grip Jaws Use emery cloth or a clean wire brush to periodically clean the surfaces of grip jaws. (Note: Aluminium-strand conductors may have a die-grease coating, which can deposit on grip jaws. New aluminium conductors should be wiped clean before grip application. Grip jaws should be wiped clean of all grease before use.) Be sure to clean grip jaws before and after each use on wire or cable, which has been galvanized or otherwise coated. Clean All Working Parts Use Klein s Cinch Cleaner/Degreaser Cat. No. 51101 to clean all joints and moving parts then apply Cinch Yellow No.51045. Check All Parts Look carefully for distortion or misalignment. Never Repair Any Grip If there is ever any question about the safe condition of any grip, please consult us directly. Please remember this rule. 9

10