Disturbance Recoder SPCR 8C27. Product Guide



Similar documents
Voltage Regulator SPAU 341 C. Product Guide

Capacitor Protection Relay SPAJ 160 C. Product Guide

Remote Monitoring and REC 501 Control Unit Product Guide

Waveguide Access Point WGA631. Product Guide

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

Substation Monitoring System SMS 510. Product Guide

Safety technique. Emergency stop module BO 5988 safemaster

ABB Drives. User s Manual HTL Encoder Interface FEN-31

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Application Unit, MDRC AB/S 1.1, GH Q R0111

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Temperature & Humidity SMS Alert Controller

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Relion. Power system protection and automation reference Extending substation life cycle with IEC 61850

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Arc Protection Relay REA 10_. Product Guide

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

SM/SPCR modules for SMS 010 User s Guide SMS 010 SPCR library

OZW30. Central Unit SYNERGYR

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

Calculation of the Current Transformer Accuracy Limit Factor Application Note

PCS0100en Persy Control Services B.V. Netherlands

FREJA 300 Relay Testing System

Communication Unit 560CMU05 Data sheet

Multi-Range Programmable DC Power Supplies 9115 Series

USB-500 Series Stand-Alone, Low-Cost Data Loggers

Current Monitoring Kit

AC3200 INTELLIGENT BROADBAND AMPLIFIER

HEAT MONITORING AND CONTROL INSTRUMENTS FOR TRANSFORMERS MB 103 TEMPERATURE CONTROL UNIT PT 100 TEMPERATURE SENSOR

REA 10_ 1MRS MBG

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Analog signal converters CC-E I/I Current / current isolators

Current and voltage measuring relays

Quick Connect. quick - simple - efficient.

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

TRACTION NETWORK MONITORING AND PROTECTION SYSTEM SMTN-3 CITY ELECTRIC TRANSPORT RAILWAYS METRO INDUSTRY

Installation manual. Generator Paralleling Controller GPC multi-line C

JUMPFLEX 857 Series ma V ma. Transducers / Relay and Optocoupler Modules

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Both variants can be used for measuring the positive sequence voltage Up or the negative sequence voltage Un.

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

Relion. Power system protection and automation reference Fast substation busbar protection with IEC and GOOSE

DC Electronic Loads 8500 series

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Inwall 4 Input / 4 Output Module

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Permissible ambient temperature Operation Storage, transport

USER MANUAL V5.0 ST100

F453. TiF453. User guide 10/11-01 PC

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Datalogger DL/N 70 Version:

EVAL-UFDC-1/UFDC-1M-16

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

1. SAFETY INFORMATION

UniPi technical documentation REV 1.1

Product Information Sheet UH36 Hi Pot Tester

Hand-held thermometer Model CTH7000

Duct Humidity Transmitter

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

Current Monitoring Kit QUICK START GUIDE

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Low Voltage Products. Switches Automatic Transfer Switches

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Managing Relion IEDs Protection and control IED manager PCM600

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Event and Fault records in SIPROTEC COMPACT and SIPROTEC 4 relays

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

NETWORK ENABLED EQUIPMENT MONITOR

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

RS - SPM. Serial parallel translator module

Polyphase kwh Electricity Meter

Modular I/O System Analog and Digital Interface Modules

How To Use The Vacon 0 Machinery

Arc Protection Relay REA 101. Operator s Manual

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

with Electronic Assistant

Accurate Measurement of the Mains Electricity Frequency

Programming Logic controllers


THERMAL ANEMOMETRY ELECTRONICS, SOFTWARE AND ACCESSORIES

NC-12 Modbus Application

MN1010 Evaluation Kit v3 User Guide

REA 101 Arc protection relay. Operator s manual

GSM ATT Modules Simply effective remote control

ABB i-bus EIB Logic Module LM/S 1.1

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

Workshop 7 PC Software - Tracker

Open Architecture Design for GPS Applications Yves Théroux, BAE Systems Canada

DMX2PWM 9 Channel Dimmer Setup Manual

water is cooled in a secondary cooling control tasks: use of seawater. Treatment of the seawater formation of algal vegetation.

Displayport Extender via 2 multimode fibers LC Duplex Connector Extends Displayport Link up to 200 meters

DS1104 R&D Controller Board

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Transcription:

Issued: April 1999 Status: Updated Version: C/26.04.2006 Data subject to change without notice Features Versatile digital disturbance recorder module for recording various phenomena in the electric power system, especially during fault conditions Can be plugged into the location of any protection relay module of the SPACOM product range No separate wiring for measuring signals or power supply needed, because the recorder module is energized and powered from the host relay Fully self-contained recorder module, no protection relay modules needed for the function A total of eight analog channels and eight digital channels can be supervised by one disturbance recorder module Total recording length 12 seconds, when all channels are recorded. Extendable to 55 seconds Increased recording capacity by reducing the number of channels recorded The total recording time can be divided into shorter parts. Thus a total of 26 subsequent recordings can be made Triggering by overcurrent, overvoltage, undervoltage or by rising or falling edge of a binary signal Triggering also possible via a serial communication command given manually with push-buttons on the front panel or automatically at certain time intervals Time-tagged events obtained from a built-in real-time clock with battery back-up The history part of the recording, that is the part preceding triggering, can be set within 0 100% of the total recording time Maximum and minimum values of voltages and currents recorded in a separate limit value register Events such as triggering, exceeding of limit values and changes in binary signal status are recorded in a log register Settings and data recorded can be downloaded via the RS 232 port of the module or via the SPA interface of the host relay Settings and recordings retained during an auxiliary supply failure Optional easy-to-use PC software available for setting recorder parameters, reading recorded data and printing out recordings 3

Application The disturbance recorder module type is a high-capacity, fully digital data recording module, which is used together with protection relays and terminals of the SPACOM product range. The recorder module provides an excellent tool for the network operating and design personnel to analyse the performance of the power system, its protection equipment and other components before, during and after a network disturbance situation. Fast identification of a network problem and correct assessment of the network behaviour enable rapid corrective measures to be taken, sometimes even before a problem develops into a major network fault. Thus high power system reliability and availability can be achieved to satisfy society s demand for a better quality of power supply. The recorder module also provides basic information for improving the planning and construction of future power systems. Design The disturbance recorder is designed to be inserted into any unoccupied relay module location of a SPACOM relay. The disturbance recorder module measures the signals available in the host relay case. Thus the number and type of signals to be recorded depend on the protection relay the location of which the disturbance recorder module occupies. Recording The disturbance recorder continuously monitors the input signals determined. When the triggering conditions are fulfilled, a recording of max. 12 seconds is made when all channels are used. 0 100% of the recording may precede the triggering. The recording memory is divided into 0.5 second blocks. When the shortest possible recording time, i.e. 0.5 seconds, is used, there is enough memory for 24 consecutive recordings. The recording memory is used as a buffer storage. When the available recording capacity has been exceeded no further recordings are made, unless the recorder module has been otherwise configured. The clock and the recording memory of the disturbance recorder module have been provided with a ten-year battery back-up to retain information over an auxiliary voltage outage. The sampling rate for each recording channel is 500 Hz. Maximum and minimum values Further, the module records the maximum and minimum values of the measured phaseto-phase voltages and the associated time stamps. In the same way the module records the max. values of the phase currents and the associated time stamps. The module also records the maximum value of the residual voltage and the maximum value of the neutral current, and their associated time stamps. For status signals the time of the last status change is recorded. For analog signals the recorded value and time change once a new maximum or minimum value is detected. Event register The event register is a log book containing a list of the events generated. The events to be recorded are selected separately in an event log mask. Any start-up of the recorder module and any event register overflow situation are recorded as events. The register also contains date and time stamps of the recorded events. Unloading of recordings The recordings can be unloaded via the serial buses. The recordings can be erased, even before they have been unloaded, with a command via the serial buses or manually by means of the push-buttons on the front panel. Data communication The indicator is provided with a serial interface connecting the equipment to the SPA bus. Self-supervision The indicator incorporates a sophisticated self-supervision system with auto-diagnosis, which increases the availability of the device and the reliability of the system. The selfsupervision system continuously monitors the hardware and the software of the indicator. When a permanent internal relay fault is detected, the IRF indicator on the relay front panel is lit. At the same time a fault message is transmitted to the higher-level system over the serial bus. Further, in most fault situa- 4

tions, a fault code is shown on the display of the device. The fault code indicates the type of the fault that has been detected. Auxiliary supply voltage The fault indicator is powered from an external 24 V dc source (20 30 V dc). The power consumption is 1.5 3 W depending on the state of the indicators and the output relays. Technical data Table 1: Input channels Number of input channels Sampling frequency per channel Resolution of A/D converters Time difference between sampling of adjacent input channels 8 analog channels 8 binary channels 500 Hz (default) 11 bit 250 µs (default) Table 2: Recording memory Recording capacity 1 MB SRAM Max. 24 recordings Max. 224 blocks 4 MB SRAM Max. 26 recordings Max. 992 blocks 1 block equals 0.5 s (=250 data samples)/channel Table 3: Analog channels Measuring ranges phase-to-phase voltages; analog channels 1 3 phase currents; analog channels 4 6 residual voltage; analog channel 7 residual current (neutral current); analog channel 8 Measuring accuracy of samples, value >0.2 range, f = 0 60 Hz Table 4: Data communication Data code Serial code Table 5: Triggering conditions Triggering level setting range Table 6: Real time clock Resolution Accuracy undervoltage setting; analog channels 1 3 overvoltage setting; analog channels 1 3 overcurrent setting; analog channels 4 6 residual voltage setting analog channel 7 residual current setting; analog channel 8 binary channel triggering condition 0 2.5 U n or 0 21 U n 0 2 I n or 0 20 I n 0 102% of U n 0 20% of I n or 0 102% of I n ±2% ASCII SPA bus connector of host relay RS 232 connector on front panel 0.2 overvoltage setting U n undervoltage setting 21 U n 0 20.4 I n 0 102% of U n 0 102% of I n Rising edge Falling edge 5 ms 1 min/month or better without synch. 5

Table 7: Options Optional PC software Type SPCR EVAL, 3 1/2 floppy disk, 3 m connection cable Table 8: Tests and standards EMC tests Fast transient test (IEC 60255-22-4) 2 kv, 5/50 ns, 1 min Electrostatic discharge Air discharge 8 kv test (IEC 60255-22-2) Contact discharge 6 kv Environmental Ambient temperature -10 +55 C conditions Storage temperature -40 +70 C 6

Block diagram Fig. 1 Block diagram and sample connection diagram BSPER8C27 7

Ordering When ordering, please specify: Ordering information Ordering example 1. Type designation and quantity, 5 pieces 2. Order number RS 892 011-AA Order numbers Disturbance recorder RS 892 011-AA References Additional information User s manual and technical description Disturbance recorder 1MRS 750511-MUM EN 8

ABB Oy Distribution Automation P.O. Box 699 FI-65101 Vaasa, FINLAND Tel +358 10 22 11 Fax +358 10 224 1094 www.abb.com/substationautomation